Hiden QIC Series Gas Analysers Real-time gas analysis systems

Similar documents
High Performance Mass Spectrometers

Residual Gas Analysis Systems for Industry

Mass Spectrometers. for Gas Analysis GAS ANALYSIS

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

The instrument should have a mass range from 2 to 2000 m/z or better Interface

Quadruple mass spectrometers (transducer type)

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

Indian Institute of Technology Kanpur Environmental Engineering and Management Department of Civil Engineering

The Helium Leak Detector

PHOENIX L300i Best-in-class Helium Leak Detectors

Practical approach and problems in in-situ RGA calibration

Major Design Features

Total Pressure Measurement Using Residual Gas Analyzers

MATRIX-MG Series. Innovation with Integrity. Automated High-Performance Gas Analyzers FT-IR

Choosing a Quadrupole Gas Analyzer Application Note #9

Operation of the Perkin Elmer TGA-GC/MS

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

FPG8601 Force Balanced Piston Gauge

INSTRUMENT INSTRUMENT YL INSTRUMENT

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

Mass Flowmeters. Mass Flowmeters for Gases

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

Pressure calibration. 20

Rheological properties. Rheological instruments backed with rheological experience. Malvern. detailed specification sheets from

Larimax. Residual Gas Analysers and Gas Analysis Systems. Index. Low Cost PC Controlled RGA PC Controlled RGA for gas analysis

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound.

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

Additel 761 Automated Pressure Calibrators

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

HumiSys HF High Flow RH Generator

A Mass Spectrometry Method for Water Vapour Transmission Rate (WVTR) testing to 10-6 gm/m 2 /day, utilising Deuterium Oxide

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Additel 761 Automated Pressure Calibrators Selection Guide

Pressure Calibrators. Series PC..., PM...

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

The Principles of Vacuum Technology

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

ADDENDUM IMPORTANT DOCUMENT INVITATION TO BID ADDENDUM. OPENING DATE & TIME: January 3, 2018 at 3:00PM

EasyLine Continuous Gas Analyzers. So smart, they re simple

Additel 761 Automated Pressure Calibrators Selection Guide

PRODUCT OVERVIEW. Gas mixers Test bench systems Leak test and impermeability testing systems High pressure dosing pumps

Additel 761 Automated Pressure Calibrators

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Thermo Scientific Model 146i Principle of Operation

Leak Checking Large Vacuum Chambers

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Gas Control Systems. Product overview

UNDERSTANDING, ACCELERATED

Comparative analysis of mass spectral matching for confident compound identification using the Advanced Electron Ionization source for GC-MS

Gas Control Systems. Product overview

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

Design Features. General Description

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

Mass Flow Controllers

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

DSC 204 HP Phoenix. High-Pressure Differential Scanning Calorimetry up to 15 MPa Method, Technique and Applications

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Panther 5 Acute Care Ventilator

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Additel 761 Automated Pressure Calibrators

Chemistry - Scale-up F.32. Lara TM - Controlled - Lab Reactor. The Concept

HiQ laboratory gas generators.

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Low-Power Atmospheric Gas Sampling System Based on ART MS Sensor and NEG-Ion Pump

APPLICATION NOTE. GC Integrated Permeation Device

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Extend the time window for the detection of low level anabolic androgenic steroids and their metabolites

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

SF 6 Product Guide. Gas Analysis Instruments and Accessories

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

AIR-X COMPACT AIR-X ON-LINE LUBRICANT AERATION MEASUREMENT. Technical Brochure ON RUNNING ENGINES

Your local gas generation partner. Precision series Modular gas generation solution for GC.

VIC offers a variety of Calibrated Gas Leaks

THE PMI AUTOMATED GAS/HELIUM PYCNOMETER PYC-G100A

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

How much do customer returns cost you?

Laser Spectrometers for Online Moisture Measurement in Natural Gas. Ken Soleyn GE M&C

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

Transcription:

Hiden QIC Series Gas Analysers Real-time gas analysis systems vacuum analysis surface science plasma diagnostics gas analysis

Application Focussed Options Multistream valves 20, 40 and 80 way versions Molecular Beam Inlet System with aligned skimmer inlets Membrane inlets QIC Catlab catalyst microreactor Furnace modules and furnace interface assemblies 8-stream heated valve inlet

QIC technology at a glance QIC-20 The QIC-20 is the entry-level system and is suitable for most general purpose laboratory applications, for example gas purity or headspace analysis. A 72 species spectral library is standard and includes cracking patterns with overlap alarms and auto-suggest for alternative peaks. Soft ionisation mode, sometimes called appearance potential MS, allows the instrument to operate at or near ionisation thresholds, greatly assisting in the simplification of complex mixture analysis. HPR-20 QIC The HPR-20 QIC extends the capabilities of the entry level system with an advanced differential pumping arrangement for processes that contain more than a few percent of helium or hydrogen. Users can interchange capillaries between low, medium and high flow versions for maximum sensitivity to a given process. A wide range of interfaces have been designed in collaboration with leading thermal analysis equipment manufacturers and are available off the shelf as standard accessories making this system ideally suited for evolved gas analysis (EGA). Two user configurable 0-10 V analogue inputs are available for external signals, temperature or pressure for example. The onboard I/O subsystem enables synchronisation of data acquisition with external events, such as the temperature ramp start signal from a TGA. HPR-20 QICplus The HPR-20 QICplus is a fully automated, quantitative on-line gas analysis system. In addition to all of the performance benefits of the HPR-20 QIC, the HPR-20 QICplus is interfaced with a four stream calibration module operating under the control of the Hiden Quantal calibration software. It is ideal for applications demanding the highest accuracy and where significant spectral overlap occurs. Quantal calibration software includes calibration, check gas and background gas recipe selection. QIC

QIC technical specifications Features Multiple configurations for ultimate flexibility Continuous monitoring over the range 100 mbar 2 atmospheres Compact, state-of-art quadrupole mass spectrometer detector Fast response inert capillary inlet Powerful, intuitive software Extensive I/O facilities for process control Standard EGA interfaces to popular thermal analysis equipment MASsoft Software TuffCell - FuelCell* Applications Fuel cell development Catalysis studies On-line analysis of trace components in process gases Environmental monitoring Combustion studies Off-gas/Headspace analysis Membrane studies Thermal Analysis TGA/DTA Integration with NIST QIC Series Specifications sample pressure sensitivity mass range detector ion source soft ionisation inlet type capillary temperature gas consumption rate response acquisition rate library external inputs acquisition control operating system communications 100 mbar to 2 bar (options to 30 bar) 100 ppb with standard single filter quadrupole 5 ppb with optional triple filter quadrupole 200 amu (300, 500, 1000 amu options) dual Faraday/Electron Multiplier direct inlet twin filament electron impact ion source 0-150 ev in 0.1eV increments 2 metre, heated quartz inert capillary up to 200 o C 20 ml/min with options down to 1 ml/min <300 msec 50 mass channels/sec 72 species library with cracking patterns x2 (0-10 V) user configurable extensive range of analogue (e.g. start/stop/pause) and digital I/O Windows NT/98/2000/XP RS232/Ethernet Quantal Calibration Application Multiple Species Trend Plotting *Image courtesy of Argonne National Laboratories

QIC Series Overview The Hiden QIC Series comprises a range of compact, state-of-the-art, real-time gas analysers. At the heart of each is one of Hiden s industry leading quadrupole mass spectrometers, providing unrivalled precision, stability and sensitivity. Gases and vapours are sampled continuously from atmospheric or near-atmospheric pressure via a flexible, heated Quartz Inert Capillary (QIC) inlet. sample Q/C inlet flow split QMS bypass flow sample flow The QIC inlet responds to changes in gas composition in less than 300 milliseconds and multiple gases can be measured simultaneously as a function of time and/or temperature. Gas concentrations may be tracked over a wide dynamic range (percent to ppb levels) at sampling rates of more than 50 data points per second. The entire gas analysis package operates under the control of Hiden s versatile MASsoft software providing extensive data handling, review and export facilities that are compatible with Windows operating systems.

Certificate No. 6738 Manufactured in England by: HIDEN ANALYTICAL LTD 420 EUROPA BOULEVARD WARRINGTON, WA5 7UN, ENGLAND Tel: +44 (0)1925 445225 Fax: +44 (0)1925 416518 Email: info@hiden.co.uk Web Site: www.hidenanalytical.com It is Hiden Analytical s policy to continually improve product performance and therefore specifications are subject to change. TECHNICAL DATA SHEET 155