KOZY Istallation Instructions

Similar documents
Avenger Model 33M Installation & Operation Instructions

Genie Supreme Model 123 Installation & Operation Instructions

Genie Supreme TM Model 123HP Installation & Operation Instructions

PRESSURE TANKS HANDLING & INSTALLATION INSTRUCTIONS INSTALLATION MANUAL CONTROL VALVES

PP-1, PP-1W, PP-2, & PP-3

Type BBS-03, BBS-05, BBS-06, BBS-25

TOTAL CAPABILITIES IN THE PIPELINE INDUSTRY. UTILITY TECHNOLOGIES INTERNATIONAL CORPORATION Cincinnati Columbus West Jefferson

Industry Guidelines POLYETHYLENE (PE) PIPES AND FITTINGS FOR COMPRESSED AIR ISSUE 6.8

Corrugated Steel Water Tanks Durable Water Storage

9700 Transmitter Submersible hydrostatic level transmitter

1074 Kenran Industrial Dr. St. Louis, MO Phone: Taylortec WV-9A Work Vest

Rapid Response Shelters. Rubber Product Manual

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

GILMONT ACCUCAL FLOWMETERS

Eaton Filtration, LLC

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

ThermoVault Max. Extreme Temperature Thermal Barrier. Product User Guide

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Type EZH Relief or Backpressure Regulator

DTG - LCD Digital Temperature Gauge USER MANUAL

HYGIENIC SIGHT FLOW INDICATORS

FLAME ARRESTOR MODEL L76C-UF

Materials: Rigid PVC body, PVC end plugs, PVC reinforcement cuff, Stainless steel cuff bands

MILLER REVOLUTION REVOLUTION KEY FEATURES. Miller Revolution Key Features. Stand Up D-Ring Spring loaded D-Ring simplifi es snaphook connection.

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

2.0 INSTALLATION & SERVICE

- Manufactured and tested in accordance with ADCI. - Each of the 9 D-rings has been tested to a breaking strength of 1000kg

North American 7337A/B/C-4 High Pressure Gas Regulators

>B< Press Range. SALES: +44 (0) FAX: +44 (0) WEB:

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

Instructions for Installation, Operating and Maintenance

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

SCA Series Inverted Bucket Steam Traps

ED 701 Hygenic Pressure Transmitter

Services. Fire Sleeve. by Carol and Brian Carpenter

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

Flange Bolt Torquing. for Resistoflex Plastic-Lined Piping Products. Torquing. Retorquing. Hydrotesting. Annual retorquing

shutoff valves 900 Series psig Manual Shutoff Valves

TECHNICAL DATA. Q = C v P S

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Eaton Filtration, LLC

RUBBER EXPANSION JOINTS

Installation, Operation, and Maintenance Manual

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel

TECHNICAL DATA OBSOLETE

Liquid level glasses, type LLG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Miller Revolution Key Features

Flexible Metal Hose Products

Engineering Data Sheet

1301 Series High-Pressure Regulators

1805 Series Relief Valves

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

BALL VALVE ASSEMBLY AND MAINTENANCE PROCEDURE. REF. DOC.MMM900N Rev.1 March 2014 SERIES M DIN / ANSI. Page 1 of 17

TECHNICAL DATA. Q= Cv S

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

750 Cable Cutter INSTRUCTION MANUAL

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

300 Series. Automatic Hydraulic Control Valves

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

1305 Series Pressure Reducing Regulators

Array Solutions 350 Gloria Rd Sunnyvale, TX Phone FAX

Installation, Operation, and Maintenance Manual

HYDRAULIC PUNCH DRIVER 38456, 38520, 7306 / 7306SB, 7310 / 7310SB, 7506, 7606SB, 7610SB, 7625 / 7625Pg / 7625PgSB, 7646 / 7646Pg / 7646PgSB

Liquid Level Controllers

PVC FASTTAP SADDLES for IPS Mains. Main Size OUTLET 1 FPT 3/4 CTS (7/8 OD) COMPRESSION 1 CTS (1 1/8 OD) COMPRESSION 3/4 IPS COMPRESSION

T208VR Series Tank Blanketing Vacuum Regulator

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS

Pure-Flo Handwheel Operated Valves (970) Instruction Manual

RECOVERY VEST MANUAL

Smooth Vent Valve. XVD Series

Pressure Independent Control Series

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

ENGINEERING DRAWING PACKET

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

SECTION DIGESTER GAS SAFETY AND CONTROL EQUIPMENT

TECHNICAL BULLETIN. Sigma-Aldrich Pure-Pac II System. Technical Bulletin AL-236

(12) Patent Application Publication (10) Pub. No.: US 2006/ A1

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

Fisher 4660 High-Low Pressure Pilot

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

627 Series Pressure Reducing Regulators

Installation Instructions

Manufacturing, Inc. Manual. Series I UT3030, UT5036, UT5042 & UT5052 (S/N KA1096A-) Rolling Spike Update Ultra-Till (Disc & Coulter)

SR100 Series Service Regulators. Technical Bulletin

>B< Press Range. SALES: +44 (0) FAX: +44 (0) WEB:

SEALED CONNECTORS FOR THE LIMIT SWITCHES

Smart Water Application Technologies (SWAT) TM

PC3_ and PC4_ Pipeline Connectors

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

BALL VALVE ASSEMBLY AND MAINTENANCE PROCEDURE FOR LCV BALL VALVES REF. DOC. MMM LCVE Rev.0 July 2010 SERIES SFF & SFR.

Transcription:

KOZY Istallation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales, LA 70737 Phone: (225)-644-5255 Website: www.geniefilters.com Fax: (225)-644-3975 E-mail: sales@geniefilters.com Safety Warnings! } } If Kozy will be in contact with sample equipment exceeding 250 F (121.1 C), confirm that the Kozy is equipped with the optional high temperature lining.

Technical Specifications Technical Specifications Material construction Standard Shell: 100% woven polyester with acrylic coating Optional High Temperature Liner: Vermiculite-coated fiberglass fabric Thread: 100% polyester #16/92 (4 ply) Straps: 1 nylon webbing with stainless steel d-rings Maximum temperature Minimum temperature Calculated R value Enviromentally friendly Standard Shell: 250 F (121.1 C) High Temp Liner: Inside contact temperature 400 F (204.4 C) Materials of construction can withstand -58 F (-50 C) temperatures; however, the insulating capabilities will be greatly diminished at these extreme temperatures. Alternative insulating options are recommended when the minimum ambient temperature is below 45 F (7.2 C) for extended periods of time. 1.7R @ 1/2 Dust, Fiber, and CFC free Ozone depletion potential of zero 2

Installation Instructions Step 1. Installing the Pipe Blanket Locate and Open the Velcro Tab (Figure 1) Wrap the Pipe Blanket around Tread-o-let (Figure 2) Loop the Blanket Straps around the Pipeline (up to 24 ) Tighten and Secure with the D-Ring Connector (Figure 3) Figure 1 Figure 2 Figure 3 3

Installation Instructions Step 2. Installing the Probe Jacket Open the Velcro Tabs for the Probe Jacket. (Figure 4) Connect the Probe Jacket to the Pipeline Blanket (Figure 5) Secure the Velcro Tab Tightly around the Base to Prevent Leaks (Figure 6) Secure the Velcro around the Regulator and Sample Line Connections (Figure 7) Figure 4 Figure 5 Figure 6 Figure 7 Shown with optional 6 Transition Piece 4

Installation Instructions Step 3. Installing the Optional Valve Cover Extension Attach valve cover bottom to pipe blanket (Figure 8) Adjust size as needed to fit snuggly around valve Use straps and D-rings to cinch cover tightly around valve Attach valve cover top to valve cover bottom, secure tightly around vavlve (Figure 9) Attach Probe Jacket to top of valve cover (Figure 10) Figure 8 Figure 9 Figure 10 5

Dimensions Regulator Cover (GR, GHR, JTR, JTR-H) 9 PROBE JACKET (KZ-1) Standard Assembly (GPR, GPSD, GP2) 13.5 Valve Cover Assembly (750, 755, or 760 through flanged valve or unibody flanged model) (702 with flanged valve) PROBE JACKET (KZ-1) 13.5 11 REGULATOR COVER (KZ-10-L) PIPE BLANKET VALVE COVER EXTENSION ASSEMBLY 9-12 DIA. (KZ-5) 10-18 PROBE JACKET (KZ-1) Transition Piece Assembly (701, 702, 750, 755, 760) 13.5 SYSTEM COVER (745 & 702/750/760/GP2 w/ External Regulator) 17.5 PIPE BLANKET SYSTEM COVER (KZ-9-L) ~5.5 6 OR 12 TRANSITION PIECE (KZ-3 OR KZ-4) 3 LONGER NECK THAN KZ-1 PIPE BLANKET PIPE BLANKET 6

Model Numbering & Additional Part Numbers Model Numbering & Additional Part Numbers Your model number is determined by your specific needs. Choose options below. Component 1 = Probe Jacket 2 = Pipe Blanket 3 = 6 Transition piece 4 = 12 Transition piece 5 = Valve Cover Extension Assembly (Adjustable) 9 = System Cover 10 = Regulator cover Liner options Blank = Standard *L = High temperature (required when Kozy will be in contact with sample equipment exceeding 250 ºF (121.1ºC)) * Must be selected with models 9 & 10 How to build the model number: Specify model numbers for multiple components to make a Kozy Assembly tailored to your equipment. KZ Component Liner options Genie, G.U.T.S. ȚM and Tornado TM are trademarks or registered trademarks of A + Corporation, LLC. All other referenced trademarks are the property of their respective owners.