No.600,No.21 Supmea Automation Co.,Ltd. Vortex flow meter. Datasheet DY2900

Similar documents
PCDY01 Dissolved Oxygen Meter

Oxymax COS61/COS61D. Technical Information

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

Triton DO8 Dissolved Oxygen Sensors ELECTRO-CHEMICAL DEVICES

Oxymax W COS51D. Technical Information. Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor

Optical Dissolved Oxygen Meter

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Optical Dissolved Oxygen Meter

COM280. Technical Information. Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

陕西创威科技有限公司. Shaanxi Creat Wit Technology Co., Ltd. Precision pressure calibrator-cwy300 Operating Manual

BUBBLER CONTROL SYSTEM

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Integral type Differential pressure flowmeter VNT Series

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

analytical bulk flow distance FLOW level pressure temperature industrial communication

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

BUBBLER CONTROL SYSTEM

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

ACV-10 Automatic Control Valve

Features. Description

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Pressure transmitter PASCAL Ci4

OxiQuant S. Operating Instructions

628 Differential Pressure Decay Leak Tester

Programmable pressure and temperature transmitters PTM/RS485

OC508 Programmable mv Calibrator

Instruments for Measurement of Dissolved CO 2 and O 2 in Beverages

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

Heavy Duty Dissolved Oxygen Meter

Parametrable / Programmable Pressure Transmitter

FLUORESCENCE DETERMINATION OF OXYGEN

LUGB Vortex Flowmeter

High-performance submersible pressure transmitter For level measurement Model LH-20

Pneumatic high-pressure controller Model CPC7000

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Oxygen Meter User Manual

Additel 761 Automated Pressure Calibrators

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Coriolis Mass Flow Meter

Operating manual. Oxi 3205 O mg/l C. [Sal] Dissolved oxygen (D.O.) meter

Programmable pressure and temperature transmitters PTM/RS485

780S Ultra High Purity Series

Sensoric 4-20 ma Transmitter Board Operation Manual

GasSense NDIR User Manual

Pressure Sensitive Paint (PSP) / Temperature Sensitive Paint (TSP) Part 1

Programmable Submersible Level Transmitters

Instruction Manual Differential Pressure Transmitter

MPM426W/436W Submersible Level Transmitter

High-performance submersible pressure transmitter For level measurement Model LH-10

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

CCT-7320/ROC-2313 Reverse Osmosis Controller

D i s s o l v e d O x y g e n M e a s u r e m e n t

Additel 761 Automated Pressure Calibrators

For Multi-Parameter Meters see mvx

Dissolved Oxygen OPERATING INSTRUCTIONS

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

Dissolved Oxygen Guide

For Multi-Parameter Meters see mvx

Flowatch Multiphase Flow Meter

MMS Mercury Monitoring System for Natural Gas

Model 601CV. Mass Flow Controller. Product Features:

High-performance submersible pressure transmitter For level measurement Model LH-20

PreSens. Manual OxoPlate. OxoPlate OP96C. PreSens Precision Sensing

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

Over 20,000 Strain Gage Target flowmeters installed since 1952.

Built-in Purge Control Functions

High-performance submersible pressure transmitter For level measurement Model LH-20

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Visualize Nitrogen Gas Consumption

HumiSys HF High Flow RH Generator

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Additel 761 Automated Pressure Calibrators Selection Guide

T EK-COR 1100A Coriolis Mass Flowmeter

NOVATECH OXYGEN /CARBON DIOXIDE ANALYSER /TRANSMITTER MODEL 1537

12mm Dissolved Oxygen Sensor Care and Use Instructions

Additel 761 Automated Pressure Calibrators

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0)

Carbo Online CO 2 Analyzer for Beverages. ::: Great People Great Instruments

Additel 761 Automated Pressure Calibrators Selection Guide

C-Flow Coriolis Mass Flow Meters

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Columbus Instruments

Hand-held pressure calibrator with integrated pump Model CPH6600

Transcription:

Vortex flow meter Datasheet DY2900

Dissolved oxygen meter DY2900 Dissolved oxygen meter Product description: DY2900 Dissolved oxygen online analyzer, an intelligent online chemical analyzer. The cap of the sensor is coated with a luminescent material. Blue light from an LED illuminates the luminescent chemical. The luminescent chemical instantly becomes excited and releases red light. The time and intensity of red light are inversely proportional to the concentration of oxygen molecules, So the concentration of oxygen molecules is calculated. DY2900 Dissolved Oxygen meter Application: Sewage treatment plants: Oxygen measurement and regulation in the activated sludge basin for a highly efficient biological cleaning process Environmental protection water monitoring: Oxygen measurement in rivers, lakes or seas as an indicator of the water quality Water treatment: Oxygen measurement for status monitoring of drinking water for example (oxygen enrichment, corrosion protection etc.) Fish farming: Oxygen measurement and regulation for optimum living and growth conditions

Features Support dissolved oxygen(do), saturation(sat), oxygen partial pressure(opp) and temperature measure. Support upper/lower limit control, transmitting output, RS485 communication. Configurable manual and auto temperature offset function. Configurable upper/lower limit alarm and delay. Configurable hummer and LCD backlight switch. Optional language, Chinese and English. Zero oxygen and full-scale calibration.

Measuring principle Sensor design: Oxygen-sensitive molecules (markers) are integrated in an optically active layer (fluorescence layer). The surface of the fluorescence layer is in contact with the medium. The sensor optics are directed at the underside of the fluorescence layer. There is an equilibrium between the oxygen partial pressure in the medium and that in the fluorescence layer: If the sensor is immersed in the medium, the equilibrium is established very quickly. Measuring process: The sensor optics send green light pulses to the fluorescence layer. The Oxygen-sensitive molecules instantly becomes excited and releases red light. The duration and intensity of the response signals is directly dependent on the oxygen contents and the partial pressure. If the medium is free from oxygen, the response signals are long and very intense. Oxygen molecules quench the Oxygen-sensitive molecules. As a result, the response signals are shorter and less intense. Measurement result: The sensor returns a signal that is in proportion to the oxygen concentration in the medium. The medium temperature and air pressure are already taken into account calculated in the sensor. In addition to the standard values of concentration, saturation index and partial pressure, the sensor also returns a raw measured value in μs. The value corresponds to the decay time of the fluorescence and is approx. 20 μs in air and approx. 60 μs in media free from oxygen.

Technical Specifications: Measurement variables Measuring range Resolution Accuracy Repetition Temperature measurement type Auto A/manual H Measuring range Output type Max.loop resistance Accuracy Output type Communication protocol Power supply Alarm relay Dissolved oxygen, saturation, oxygen partial pressure 0-20mg/L,0-200%,0-400hPa 0.01mg/L,0.1%,1hPa ±1.5%FS ±0.5%FS NTC 10K/PT1000-10 - 60 Resolution: 0.1 Correction accuracy: ±0.5 4-20mA current transmission output 750Ω 0.1%FS RS485 digital signal output Standard MODBUS-RTU (customizable) AC220V±10%,50Hz/60Hz (optional 24V±10%) AC250V 3A

Installation methods 1 dissolved oxygen transmitter Open a 92.5 * 92.5(mm) installation hole on the instrument cabinet or installation panel (the dimension is 100*100*150mm). Insert the instrument into the installation hole and latch on the butterfly clasp, as shown below. 2dissolved oxygen sensor

Identification of terminal Wiring diagram +12VDC: Power supply of dissolved oxygen electrode AGND: Power negative of dissolved oxygen electrode RS485-A: Dissolved oxygen electrode communication-a RS485-B: Dissolved oxygen electrode communication-b NC: Null RS485(A+): RS485 communication interface A+ Optical Dissolved Oxygen Online Analyzer Operation Manual RS485(B-): RS485 communication interface B- I(+): 4-20mA output port + I(-): 4-20mA output port - HO: High alarm of normal open relay HC: High alarm of normal close relay COM: Common port LO: Low alarm of normal open relay LC: Low alarm of normal close relay COM: Common port 220V L: AC220V fire wire NC: Null 220V N: AC220V zero wire

China Singapore Germany Malaysia China Headquarters Singapore Branch German Branch Malaysia Branch Address:No.452, No. 6 Street, Address: 2 VENTURE Address: Göttinger Straße.59 Address: No 3, Jalan Emas Hangzhou Developmental Zone, DRIVE #11-30 VISION 30449 Hannover Niedersachsen Jaya 1, Taman Industries Zhejiaing, China EXCHANGE SINGAPORE Deutschland Emas jaya Tongkang Pecah, Batu Pahat