FLAME ARRESTOR MODEL L76C-UF

Similar documents
Model 8800A. Pressure Relief and Vacuum Breaker Valve with Flame Arrester

VALVE & FLAME ARRESTER

WASTEWATER SAFETY DEVICES THAT PROTECT BIOGAS CATALOG EQUIPMENT, LIVES & THE ENVIRONMENT SMART RELIEF...SAFE SOLUTIONS SM

INDUSTRIAL PRODUCT SELECTION GUIDE

INDEX. Table of Contents. Warranty. ISO 9001 Certificate. Product Selection Guide

VAREC 180 SERIES PRESSURE REGULATORS

Pressure/Vacuum Diaphragm Valve PROTEGO UB/SF. deflagration- and endurance burning-proof

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

Horizontal Bladder Tanks

VAPOR CONTROL SYSTEMS QUALITY, DEPENDABILITY, SERVICE. REPUTATION BUILT ON. Valve Concepts, Inc. com. A Cashco, Inc.

PROTEGO Braunschweiger Flammenfilter GmbH

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

PROTECTOSEAL V A P O R & F L A M E C O N T R O L E Q U I P M E N T

Vertical Bladder Tanks

PRO-50 Instrument Supply Regulator

BLANKET GAS REGULATORS

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

VERTICAL BLADDER TANK

SERIES 3000 BLANKET GAS REGULATORS

Model TB 3-16 TECHNICAL BULLETIN. Secure-Gard Pilot Operated Vent Valve (POVV) BENEFITS TYPICAL APPLICATIONS FEATURES

HORIZONTAL BLADDER TANK

Anderson Greenwood Type 4142 piped away pressure relief valves

PROTEGO Pressure/Vacuum Relief Valves. Volume 7. with Flame Arrester - end-of-line. Volume 7. for safety and environment

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

PROTEGO Pressure/Vacuum Relief Valves. Volume 7. w ith Flame Arrester - end-of-line. for safety and environment

Noth American 7347 High Pressure Gas Regulators

MEDICAL EQUIPMENT CATALOG

Trifecta High-Pressure Systems

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation Operation Maintenance

94060 FRP Conservation Vent. Features. FRP Conservation Vent. One piece construction prevents product leakage

94060 FRP Conservation Vent. Features. FRP Conservation Vent. One piece construction prevents product leakage

ANDERSON GREENWOOD TYPE 4020 ATMOSPHERIC PRESSURE AND VACUUM RELIEF VALVES

SERIES 10. Pilot Operated Tank Blanketing Valve, 2" PROTECTOSEAL.

PRESSURE TANKS HANDLING & INSTALLATION INSTRUCTIONS INSTALLATION MANUAL CONTROL VALVES

North American 7337A/B/C-4 High Pressure Gas Regulators

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

Air Eliminators and Combination Air Eliminators Strainers

Safety Selector Valves Dual Pressure Relief Device System

ANDERSON GREENWOOD TANK BLANKETING REGULATORS

TECHNICAL DATA. Page 1 of 12

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

6-5 Maintenance Manual

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

TOTAL CAPABILITIES IN THE PIPELINE INDUSTRY. UTILITY TECHNOLOGIES INTERNATIONAL CORPORATION Cincinnati Columbus West Jefferson

829S1 Series Flexflo Pilot

DAV - WP DAV - WP. Wastewater Air Valves. Product Catalogue. (Wastewater Air Valves) DAV - WP

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Type EZH Relief or Backpressure Regulator

Instruction Manual VCG-6

Avenger Model 33M Installation & Operation Instructions

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

PROTEGO Deflagration Flame Arresters. Volume 3. Volume 3. for safety and environment

KEYSTONE. A C E C O E n v i r o n m e n t a l C o m p a n y. Bulletin 10-B

Instruction Manual Contact Pressure Vacuum Gauge

Pressure and Temperature Controls

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS

MERCER VALVE SERIES Pilot Operated THINK...MERCER FIRST MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY

Model DE-1, VDE-1 and DE-2 Air Release Heads

Features. Model DDX-LP Dry Pipe Valve System 2 (50 mm), 2½ (65 mm), 3 (80 mm), 76 mm, 4 (100 mm), 6 (150 mm), 165 mm & 8 (200mm) Listings & Approvals

1200 Series Pressure Regulators

MSC Guidelines for Pressure Vessels

Technical Data Sheet T 2025

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Model 1800 PFM Series Regulator. Technical Bulletin

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

Backed By Over 80 Years of Sampling Experience

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

Technical Standard. API6D Ball & Plug Valve. Inspection & Test Procedure

RCS Rupture Disc Assembly

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

Petrofac Client Doc. No JI-DTS-5002 Page 2 of 8 Rev. TABLE OF CONTENTS

Technical data. Back pressure limit: 27.5% of set pressure. Capacity certification: ASME Boiler & Pressure Vessel Code Section I and VIII

Model 3600 IOM Vacuum Relief Vent Side-Mounted Connection SECTION I I SERIES DESIGN AND FUNCTION

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

North American 7339 High Pressure Gas Regulators

Pipe-Away Pressure Vacuum Vent /Conservation Vent

Bourdon tube pressure gauges for chemical applications EN 837-1

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

Bourdon tube pressure gauges with glycerine filling, for chemical applications EN 837-1

North American Simplex Basket Strainers for Gas and Oil

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TYPE 3710 CARTRIDGE SPLIT SEAL Technical Specification

TECHNICAL DATA OBSOLETE

Optimizing Gas Supply for Industrial Lasers

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Sample Coolers. Water Steam Process. The largest selection of models offered by any manufacturer.

RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

Models 1720A / 1760A

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Gauge Hatch SECTION I SECTION II

PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660

Transcription:

FLAME ARRESTOR MODEL L76C-UF

Model L76C-UF The L76C-UF model is designed to inhibit flame propagation in gas piping systems and to protect low pressure tanks containing flammable liquids. Arrestors protect low flash point liquids from external sources of ignition. This provides increased fire protection and safety. Technical Details Connection Sizes: 2, 3, 4 and 6 150# ASME Flanged Connection Housing standard material: Carbon Steel, Stainless Steel Bases standard material: Aluminum, Carbon Steel, Stainless Steel Flame element standard material: 316 Stainless Steel Operational Temperature Range: -4 to 140 ºF (-20 to 60 ºC) Gas Group: NEC D; IEC IIA (MESG > 0.90 mm) Maximum Operational Pressure: see charts and IOM Burn Time: t BT short-time burn rating or better at Atmospheric Pressure (see charts and IOM) Bi-directional with respect to flow and ignition source Features & Benefits Flame arrestor element geometry maximizes flame quenching capability while minimizing pressure drop Removable element housing for each of maintenance Spiral-wound, crimped ribbon flame element Flame elements made standard with premium 316SS material Options Exterior painting or coating available Drains and instrumentation ports available Factory installed thermocouples for flame sensing available PAGE 2

Specifications Connection Size 150# ASME Housing Nominal Size A Width B Height MAWP * Carbon Steel Approx Ship. Wt. Lbs. Carbon Steel (Aluminum) A 2" 6 9.2" 16.0" 100 psig 63 (32) 3 8 11.2 16.0 100 psig 111 (64) 4 10 13.2 16.0 100 psig 132 (68) 6 16 20.0 21.0 100 psig 298 (181) B Pneumatic leak tested to 15 psig as standard. *MAWP does not reflect the maximum operational pressure of the flame arrestor. Please consult the specifications section for the correct maximum operational pressure of the arrestor. MAWP, refers only to the maximum shell pressure allowed, it has no relation or influence on the flame arresting performance of the flame arrestor. In contrast however, the maximum operational pressure of a flame arrestor, is the maximum pre-ignition pressure of vapors in the piping system in which the flame arrestor will successfully arrest the flame; per the correct application of gas group (IIA/D, MESG>0.90mm) and run-up-distance according to the IOM. Specifications subject to change without notice. Certified dimensions available upon request. PAGE 3

Specifications For an arrestor to be properly applied, all the requirements for one of the two following configuration scenarios must be met. 1) Straight Pipe, Closed End Configuration: Connection Size x Housing Size Gas Group End Condition Maximum Pipe Length from Ignition Source to Flame Arrestor Maximum Operational Pressure Allowable Bend(s)* Maximum Burn Time at Atmospheric Pressure Operational Temperature Range F ( C) 2 x 6 thru 6 x 16 D (IIA) Closed End 50 pipe diameters 17.4 psia (1.2 bara) or better, see IOM None 2.5 minutes or -4 to 140 (-20 to 60) Model L76C-UF, Straight Pipe, Closed End Configuration, is designed and tested according to EN ISO 16852:2016, except for: 1. The short time burn test was conducted at atmospheric pressure, for a time period extending past 1 minute. *No additional bends or restrictions are allowed. Figure 1: Straight Pipe, Allowable Installation Configuration Un-Protected Side Maximum Pipe Length (See Chart) Protected Side Ignition Source Flame Arrestor PAGE 4

Specifications 2) Configuration with Bend, Open End Configuration: Connection Size x Housing Size 2 x 6 thru 4 x 10 Gas Group End Condition Maximum Pipe Length from Ignition Source to Flame Arrestor D (IIA) Open End 20ft total length: A= max of 15 ft B= max of 5 ft Allowable Bend(s)* One 90 Degree Maximum Operational Pressure 15.5 psia (1.07 bara) or Maximum Burn Time at Atmospheric Pressure 2.5 minutes or Operational Temperature Range F ( C) -4 to 140 (-20 to 60) 6 x 16 D (IIA) Open End 25ft total length: A= max of 20 ft B= max of 5 ft One 90 Degree 17.4 psia (1.2 bara) or 2.5 minutes or -4 to 140 (-20 to 60) Model L76C-UF, Configuration with Bend, Open End Configuration, is designed and tested according to EN ISO 16852:2016, except for: 1. The piping on the unprotected side, consisted of ignition source, A ft of straight pipe, one 90 degree bend, B ft of straight pipe, then the arrester. 2. The short time burn test was conducted at atmospheric pressure, for a time period extending past 1 minute. *No additional bends or restrictions are allowed. Bends and flow restrictions can cause additional turbulence, which can increase the intensity of the flame propagation; potentially compromising the performance of the flame arrestor. **See below configuration with bend diagram Figure 2: Configuration with bend, Allowable Installation Configuration Ignition Source Max of A ft. Max of B ft. Flame Arrestor Protected Side 90 Bend PAGE 5

Flow Capacity Model: L76C-UF Flow Capacity for 316 Stainless Steel Element Pressure Drop (osig) 25 20 15 10 5 2 x 6 in. 3 x 8 in. 4 x 10 in. 6 x 16 in. 0 50 100 150 200 250 Flow Rate (1000 SCFH) Model: L76C-UF Flow Capacity for 316 Stainless Steel Element (Zoomed In) Pressure Drop (osig) 10 9 8 7 6 5 4 3 2 2 x 6 in. 3 x 8 in. 4 x 10 in. 6 x 16 in. 1 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 Flow Rate (1000 SCFH) The test equipment, procedures, and reporting methods utilized by Groth Corporation meet the requirements of standards API 2000/ISO 28300 and ISO 16852. Flow data are for in-line mounting and does not include entrance losses or exit losses. Flow values based on air at 60 F venting to atmospheric pressure of 14.6959 psia PAGE 6

How To Order For easy ordering, select proper model numbers MODEL # SIZE MATERIAL OPTIONS Connection Element L76C 150# ASME Bolted Connection UF Upstream Deflagration 02 03 04 06 06 = 2" x 6 08 = 3 x 8 10 = 4 x 10 16 = 6 x 16 Housing Material 3 = Carbon Steel 5 = Stainless Steel Base Material 1 = Aluminum 3 = Carbon Steel 3 = Stainless Steel OOO = No Options Notes Include model number and setting when ordering For special options, consult factory Example L 7 6 C U F 0 2 0 6 3 3 O O O Indicates a 2" x 6" Model L76C with carbon steel base, carbon steel housing, 150# ASME bolted inlet/outlet, and no other options. PAGE 7

LAMOTVALVEARRESTOR.COM LaMot Valve & Arrestor reserves the right to alter the information in this publication without notice. // 2019 LaMot Valve & Arrestor Reproduction without written permission is prohibited. LIT1849 // 0219