An Efficient Vortex Tube With Max C.O.P

Similar documents
A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India)

Performance Improvement of Ranque-Hilsch Vortex Tube by Varying inside Surface Roughness of Hot Tube

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Development of Two Opposing Nozzle Vortex Tube Using Air as Working Fluid

FABRICATION AND OPTIMIZATION OF PERFORMANCE OF VORTEX TUBE PARAMETERS

Effect of Hot End Obstruction and Nozzle on the Performance of Vortex Tube

An Experimental Performance Study of Vortex Tube Refrigeration System

Fabrication and Experimental Analysis of a Vortex Tube Refrigeration system

Modeling and Investigation of Change in Working Parameters on the Performance of the Vortex Tube with CFD Analysis

EXPERIMENTAL PERFORMANCE ANALYSIS OF VORTEX TUBE FOR VARIOUS PARAMETERS

DEVELOPMENT OF TWO OPPOSING NOZZLE VORTEX TUBE USING AIR AS WORKING FLUID

Experimental Investigation and Modification of Ranque Hilsch Vortex Tube

Hermetic Compressor With Improved Motor Cooling

An Experimental Investigation of the Optimum Geometry for Energy Separation of the Ranque- Hilsch Vortex Tube

Vortex Tubes. Vortex Tubes. Cold air to -50 F (-46 C) from your compressed air supply with no moving parts!

EXPERIMENTAL STUDY OF THE ENERGY SEPARATION IN COUNTER FLOW VORTEX TUBE

Vortex Tube Short Course February 2017

To Study the Effects of Design Parameters on Vortex Tube with CFD Analysis

Applied Fluid Mechanics

SIMULTANEOUS OPTIMIZATION OF HOT AND COLD OUTLET AIR TEMPERATURES OF VORTEX TUBE USING GREY RELATIONAL ANALYSIS AND TAGUCHI METHOD

A 1/4 ton of refrigeration in the palm of your hand!

Experimental Investigation of Vortex Tube Refrigeration

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF HELICAL NOZZLES EFFECTS ON THE ENERGY SEPARATION IN A VORTEX TUBE

Effect of Cold Fraction and Orifice Diameter on the Performance of Modified Vortex Tube with Dual Forced Vortex Flow

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.

CHAPTER-2 IMPACT OF JET

THE EFFECT OF L/D RATIO ON THE TEMPERATURE SEPARATION IN THE COUNTERFLOW VORTEX TUBE

Please welcome for any correction or misprint in the entire manuscript and your valuable suggestions kindly mail us

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

A review on design criteria for vortex tubes

ASSIGNMENT 2 CHE 3473

ASSIGNMENT 2 CHE 3473

To plot the following performance characteristics; A pump is a device, which lifts water from a lower level to a higher

VORTEX TUBE COOLING SYSTEM

PERFORMANCE STUDY OF A MODIFIED RANQUE-HILSCH VORTEX TUBE

Refrigeration and Air Conditioning Technical leaflet

Fundamentals of Turboexpanders Basic Theory and Design

HW-1: Due by 5:00 pm EDT on Wednesday 13 June 2018 to GradeScope.

Compressors. Basic Classification and design overview

CERTIFICATES OF COMPETENCY IN THE MERCHANT NAVY MARINE ENGINEER OFFICER

AIR EJECTOR WITH A DIFFUSER THAT INCLUDES BOUNDARY LAYER SUCTION

-Fundamentals of Fluid Mechanics- Bruce Munson, Donald Young, Theodore Okiishi, Wade Huebsch

Process Nature of Process

Investigation of Suction Process of Scroll Compressors

Modification and experimental research on vortex tube

Design Review Agenda

Design, Static Structural & Model Analysis of Water Ring Vacuum Pump Impeller

ISSN (Print) : Wasan Naksanee et al. / International Journal of Engineering and Technology (IJET)

An Investigation of Liquid Injection in Refrigeration Screw Compressors

Lab Problems. Lab Problems for Chapter Fluid Characterization by Use of a Stormer Viscometer L-1

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

Understanding Lobe Blowers Roots Blowers. Article written by Technical Team of EVEREST GROUP

Efficiency Improvement of Rotary Compressor by Improving the Discharge path through Simulation

A B isothermal compression at a temperature of 300 K. The work done on the air is 104 J.

Procedure 1: Volume vs. Pressure 1.) Using the lap tops, go to the Physics Education Technology from the University of Colorado at:

CFD Simulation of the Flow Through Reciprocating Compressor Self-Acting Valves

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT

Fabrication and Experimental Analysis of Vortex Tube by Varying the Geometry and Material

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models

Effect of Inlet Clearance Gap on the Performance of an Industrial Centrifugal Blower with Parallel Wall Volute

ASSIGNMENT-1 HYDROPOWER PLANT

ME1251 THERMAL ENGINEERING UNIT IV AIR COMPRESSORS

PERFORMANCE ANALYSIS OF CYLINDRICAL TYPE AIR EJECTOR

DEVELOPMENT OF HIGH ALTITUDE TEST FACILITY FOR COLD JET SIMULATION

GLOSSARY OF TERMS. Adiabatic Compression Compression process when all heat of compression is retained in the gas being compressed.

TESTING AND ANALYZING ON P-V DIAGRAM OF CO 2 ROLLING PISTON EXPANDER

Quiz #1 Thermodynamics Spring, 2018 Closed Book, Open Appendices, Closed Notes, CLOSED CALCULATORS

Fig. 2. M.I. Yaroslavtsev, 2002

EXPERIMENTAL ANALYSIS OF FIN TUBE AND BARE TUBE TYPE TUBE-IN-TUBE HEAT EXCHANGER

The exit velocity of a compressed air cannon

Figure 1 Schematic of opposing air bearing concept

ASSIGNMENT-1 HYDROPOWER PLANT

Performance Characteristics of Airlift Pumps with Vortex Induced by Tangential Fluid Injection

Suprasanna Rao Ravur 1, Subba reddy. E. V 2 1,2 Thermal Engineering, KKIT/JNTU Anantapur, India. IJRASET 2015: All Rights are Reserved 291

Bubble Elimination Device in Hydraulic Systems

MATHEMATICAL MODELING OF PERFORMANCE OF A LIQUD PISTON COMPRESSOR

Research and optimization of intake restrictor for Formula SAE car engine

LECTURE 20 FLOW CONTROL VAVLES SELF EVALUATION QUESTIONS AND ANSWERS

Development of Gasdynamic Probe for Total Temperature Measurement in gases

Improvement of the Volumetric and Isentropic Efficiency Due to Modifications of the Suction Chamber

A 1/4 ton of refrigeration in the palm of your hand!

Chapter 5. Nov 6 1:02 PM

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

(Refer Slide Time: 2:16)

Lecture 26 HYDRAULIC CIRCUIT DESIGN AND ANALYSIS

ENGINEERING FLUID MECHANICS

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Chapter 3 EXPERIMENTAL: EQUIPMENT, SET-UP, AND PROCEDURE

COMPUTATIONAL FLOW MODEL OF WESTFALL'S LEADING TAB FLOW CONDITIONER AGM-09-R-08 Rev. B. By Kimbal A. Hall, PE

EXPERIMENTAL STUDY OF HOT INERT GAS JET IGNITION OF HYDROGEN-OXYGEN MIXTURE

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

Design and Static Structural Analysis of Cylinder and Piston of Two Stage Reciprocating Compressors Using ANSYS

Effect of Coiled Capillary Tube Pitch on Vapour Compression Refrigeration System Performance

An investigation of a micro-scale Ranque-Hilsch vortex tube.

On a few Aspects of Vortex Motion

Test Report # Rev 0. Adiabatic Compression With Constant Bleed Valve

Instruction Manual. Pipe Friction Training Panel

International Journal of Advance Engineering and Research Development DESIGN CALCULATIONS TO EVALUATE PERFORMANCE PARAMETERS OF COMPRESSOR VALVE

Transcription:

An Efficient Vortex Tube With Max C.O.P S. Kasim Vali 1*, K. Prabhakar 2, C. Mohan Naidu 3, B. Pavan Bharadwaja 4 1. M.Tech Student Dept. Of Mechanical Engineering Gates Institute of technology, Gooty, A.p, India. 2. Assistant professor, Dept. Of Mechanical Engineering Gates Institute of technology, Gooty, A.p, India 3. Assistant professor, Dept. Of Mechanical Engineering Gates Institute of technology, Gooty, A.p, India 4. M.Tech student,dept. Of Mechanical Engineering Amrita school of engineering,coimbatore,t.n,india 1.1 INTRODUCTION: The vortex tube, also known as the Ranque-Hilsch vortex tube (RHVT) is a device which generates separated flows of cold and hot gases from a single compressed gas source. The vortex tube was invented quite by accident in 1931 by George Ranque, a French physics student, while experimenting with a vortex-type pump that he had developed, and then he noticed warm air exhausting from one end, and cold air from the other. Ranque soon forgot about his pump and started a small firm to exploit the commercial potential for this strange device that produced hot and cold air with no moving parts. However, it soon failed and the vortex tube slipped into obscurity until 1945 when Rudolph Hilsch, a German physicist, published a widely read scientific paper on the device.[3] Much earlier, the great nineteenth century physicist, James Clerk Maxwell postulated that since heat involves the movement of molecules, we might someday be able to get hot and cold air from the same device with the help of a "friendly little demon" who would sort out and separate the hot and cold molecules of air.[4] Hilsch Tube", and "Maxwell s Demon". By any name, it has in recent years gained acceptance as a simple, reliable and low cost answer to a wide variety of industrial spot cooling problems. When high-pressure gas is tangentially injected into the vortex chamber via the inlet nozzle, a swirling flow is created inside the vortex chamber. In the vortex chamber, part of the gas exists via the cold exhaust directly, and another part called as free vortex swirls to the hot end, where it reverses by the control valve creating a forced vortex moving from the hot end to the cold end. Heat transfer takes place between the free end and the forced vortices there by producing two streams, one hot stream and the other is cold stream at its ends.[9] 1.2 COMPONENTS OF VORTEX TUBE: The systematic diameter gram of vortex tube is shown in the figure. Thus, the vortex tube has been variously known as the "Ranque Vortex Tube", the "Hilsch Tube", the "Ranque- Fig:1.2 Vortex Tube. 317

It consists of the following parts. 1. Nozzle. 2. Diaphragms. 3. Control valve. 4. Hot air side. 5. Cold air side The actual diameter gram of vortex tube is shown below. from high-pressure region. During this process, energy transfer takes place between reversed stream and forward stream and therefore air stream through the core gets cooled below the inlet temperature of the air in the vortex tube while the air stream in forward direction gets heated. The cold stream is escaped through the diaphragms hole into the cold side, while hot stream is passed through the opening of the control valve. By controlling the opening of the valve, the quantity of the cold air and its temperature can be varied.[6] Fig: 1.2.1 Sectional view of Vortex Tube. 1.3 WORKING OF VORTEX TUBE: A compressed air is passed through the nozzle as shown in figure. Here air expands and acquires high velocity due to particular shape of the nozzle. A vortex flow is created in the chamber and air travels in spiral motion along the periphery of the hot side. Then, the rotating air is forced down the inner walls of the hot tube at speeds reaching 1,, rpm. The control valve restricts this flow. When the pressure of the air near the valve is made more than the outside by partly closing the valve, a reversed axial flow through the core of the hot side starts Fig:1.3 3D Sectional view of Vortex tube. 2.METHODOLOGY 2.1 ASSUMPTIONS: 1. Mass flow rate of air entering into compressor is equal to mass flow rate of air entering in to the vortex tube maintaining at constant pressure in receiver tank.[2] 2. Assuming no losses i.e. inlet mass flow rate of air is equal to mass flow rate of cold air + mass flow rate of hot air. [5] 318

2.2 ADIABATIC EFFICIENCY OF AIR COMPRESSOR: The coefficient of performance of the vortex tube is the product of adiabatic efficiency of the air compressor and adiabatic efficiency of the vortex tube and [(P a /P i ) (γ-1)/γ ], the adiabatic efficiency of the Air compressor is to be calculated first.[3] 2.3 SPECIFICATIONS OF THE AIR COMPRESSOR USED : Compressor H.P 3 No of cylinders 2 Diameter of two L.P cylinders 7 mm H.P cylinders 5 mm Stroke length 85 mm Number of stages 2 Coefficient of discharge.62 Working pressure Orifice diameter FOR CYLINDRICAL TUBE: 12 lbs 2 mm Energy input 36 x no.of revolutions of energy meter time taken in sec x 1 x.8 36 x1 87.28x1x.8 5.156 kw Theoretical volume V 1 Л x d x d x L x 2 x N 4 x 6 Л x.7 x.7 x.85 x 2 x 886.96m 3 /sec 4 x 6 Adiabatic Work Done γ γ 1 P 1-1] (ץ/ 1 -ץ) ) 1 V 1 [(p 2 /p 1.4 * 1*1 5 *.96 [(6/1) (.4/1.4) - 1]/.4 2239.2 J Adiabatic Efficiency of a Compressor - (Adiabatic S.No Pressure P i, bar Cold (T c ), C Hot (T h ), C Difference T T h- T c C Cold Drop T c, C Hot Drop T h, C Cold mass Fraction μ Adiabatic Efficiency 1 2 23 36 13 7 6.4615.699.798 2 3 21 38 17 9 8.475.5294.967 3 4 21 39 18 9 9.5.4622.122 4 5 2 4 2 1 1.5.455.1111 5 6 18 42 24 12 12.5.52.1311 Table:2.1 2.2 AIR COMPRESSOR ADIABATIC EFFICIENCY CALCULATION: CALCULATIONS: Work Done)/(Energy Input ) 2239.2/(5.156*1) Adiabatic Efficiency of a Compressor.4342 43% P 1 atm pressure 1 bar P 2 delivery pressure 6 bar 319

2.2SPECIMEN CALCULATIONS: SPECIMEN CALCULATIONS FOR THE INLET PRESSURE OF AIR Pi 6 bar OBSERVATIONS: 5. Static erature Drop Due To Expansion T c Ti T c T i [1-(P a /P i ) (γ-1)/γ ] ( 1/6 ) {1.4-1}/1.4 ] T c 3[1-1. Atmospheric pressure P a 1 bar. 12.1 C 2. Inlet pressure of air P i 6 bar 6. Relative erature Drop ( T rel ) T c /( T c ) 3. Inlet temperature of air T i 3 C 4. Cold air exit temperature T c 18 C 5. Hot air exit temperature T h 42 C CALCULATIONS: 1. Cold drop temperature T c T i - T c Tc 3 18 12 C 2. Hot raise temperature T h T h T i T h 42 3 12 C 3. erature Drop at the two ends T T h - T c T 3 GRAPHS After conducting the experiment we noted the tabulated results and the following graphs are plotted. 3.1 COLD END TEMPERATURE VARIATION AT DIFFERENT PRESSURES 25 T E 2 M P E 15 R A 1 T U 5 R E 2 3 4 5 6 pressure in bar Fig..3.1 COLD END TEMPERATURE VARIATION AT DIFFERENT PRESSURES cyl in d 42 18 24 C 4. Cold mass fraction μ T h T h + T c 12 12+12.5 μ From the above Fig. 6.3.1 it is clear that at any given pressure the temperature of the conical hot tube is better when compared to cylindrical hot tube and the temperature difference between them is proportional to pressure i.e., the temperature difference is increasing progressively with pressure. 32

3.2 HOT END TEMPERATURE VARIATION AT DIFFERENT PRESSURES 3.3 VARIATION AT DIFFERENT PRESSURES S.N o 5 4 3 2 1 Pressu re in Bar of cylind er hot tube of conic al hot tube 1 2.798.18 5 2 3.967.128 9 3 4.122.119 6 4 5.1111.133 5 6.1311.154 % increa se in of conical hot tube 35.96 33.29 17.25 19.71 17.46 cylind er conica l 2 3 4 5 6 Fig.3.1 HOT END TEMPERATURE VARIATION AT DIFFERENTPRESSURES.3.25.2.15.1.5 Fig..3.3 VARIATION AT DIFFERENT PRESSURES The above Fig. 3.3 is plotted for pressure V/s. From the graph it is noted that the of the vortex tube with conical hot end is higher than the vortex tube with cylindrical hot tube. From the above three graphs it is noted that the performance of the vortex tube with conical hot tube is better than the vortex tube with cylindrical hot tube. 4. RESULTS &DISCUSSIONS RESULTS: 2 3 4 5 6 pressure in bar After evaluating the performance of vortex tube with cylindrical and conical hot tubes it was found that the vortex tube with conical hot tube gives the better performance than the cylindrical hot tube i.e. there is an increase in cop of about 25%-3%. The values obtained for cylindrical and conical hot tubes at various pressures are: conical cylindric al From the above Fig. 6.3.1 the temperature of hot end for conical hot tube is more compared to cylindrical hot tube.from this we can say that temperature difference between them is proportional to pressure i.e., the temperature difference is increasing progressively with pressure. DISCUSSIONS: The performance of the vortex tube was evaluated by conducting the experiment by replacing the cylindrical hot tube with a conical hot tube at various inlet pressures The other parameters like orifice diameter, nozzle is kept unchanged. The 321

highest is obtained at 6bar for taper tube and the value is.154. The lowest cold temperature for vortex tube with conical hot tube is 14 C at 6 bar and with cylindrical hot tube is 18 C at 6 bar. The highest hot temperature for vortex tube with conical hot tube is 44 C at 6 bar and with cylindrical hot tube is 42 C at 6 bar. Cold mass fraction obtained is better for the vortex tube with the conical hot tube than the cylindrical hot tube see table 6.2.3.1 & table 6.2.5.1 The maximum of 3 C difference between hot and cold ends temperature for vortex tube with the conical hot tube and maximum of 24 C difference between hot and cold ends temperature for vortex tube with the cylindrical tube is obtained. REFERENCES [1].FikretKocabas, Modeling of heating and cooling performance of counter flow type vortex tube by using artificial neural network, Elsevier Journal, February 21. [2].K. Dincer, Experimental investigation and exergy analysis of the performance of a counter flow Ranque-Hilsch vortex tube with regard to nozzle cross-section areas, Elsevier Journal, April 21. [3].Prabakaran.J, Effect of Diameter of Orifice and Nozzle on the performance of Counter flow Vortex tube, IJEST Journal, 21. [4].J. Prabakaran, Effect of orifice and pressure of counter flow vortex tube, IJST, April 21. [5].Nader Pourmahmoud, The effect of L/D ratio on the erature separation in the Counter flow Vortex tube, IJRRAS Journal, January 211. [6].ChengmingGao, Experimental study on the Ranque-Hilsch Vortex Ttube, PhD Thesis. [7].S.C Arora and S. Domkundwar, A course in refrigeration and air conditioning, DhanapatRai& Sons Publications. [8]. www.exair.com. [1]. www.p.a. Hilton.com [11]. www. Air Tx international.com IJMERR.JOOURNAL 322