Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Similar documents
Self-operated Pressure Regulators for special applications

Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB EN. Self-operated Pressure Regulators. Type 2335 Excess Pressure Valve with pilot valve

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Pressure Reducing Valve for Steam Type 2333 A

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Declaration of Conformity as per Directive 97/23/EC

EB EN. Type 44-0 B Steam Pressure Reducing Valve Type 44-1 B Pressure Reducing Valve. Translation of original instructions

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Type 4708 Supply Pressure Regulator

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

Type 4708 Supply Pressure Regulator

Declaration of Conformity as per Directive 97/23/EC

Declaration of Conformity as per Directive 97/23/EC

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Type 4708 Supply Pressure Regulator

Declaration of Conformity as per Directive 97/23/EC and Manufacturer s Declaration as per Directive 98/37/EC

Mounting and Operating Instructions EB 9520 EN. Differential Pressure and Flow Meter Media 05

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Mounting and Operating Instructions EB 9520 EN. Differential Pressure and Flow Meter Media 05

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Pressure relief valve

Pressure relief valve

Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E

Products for Cryogenic Applications

Mounting and Operating Instructions EB 9519 EN. Differential Pressure and Flow Meter Media 5. Zero adjuster

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

SRV66 Sanitary Pressure Reducing Valve

Instruction Manual Contact Pressure Vacuum Gauge

Pressure Regulators. Operating Instructions. Instrumentation

MF2M Monnier Miniature Compressed Air Filter

Contents. 1. General information BROEN BALLOMAX Steel Ball Valves Approvals Quality Management...2

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

TSS21 Sealed Thermostatic Steam Tracer Trap

CAST IRON SAFETY VALVE TYPE 6301

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Dri-Line Mk3 Monnier Compressed Air Drain Trap

Model: 43T. Bermad Pressure Relief Valve

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

TP1 and TP2 Temporary Cone Shaped Strainers

Manual Actuated Boiler Blowdown Valves

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Pfeiffer. Operating, assembly and maintenance instructions for discontinuous sampling valve Series 27i. 1. Design, operation and dimensions

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

BCV31 DN20 - Blowdown Control Valve

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

PV4 and PV6 Piston Valves

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Steam trap BK 37 BK 28 BK 29 BK 37 ASME BK 28 ASME BK 29 ASME

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

Universal Charging and Testing Unit FPU-1

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

LRS(H)4 Pressure-Reducing Regulator User Manual

BR 27g. Operating, assembly and maintenance instructions for discontinuous sampling valve. 1. Design, operation and dimensions:

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

CP10 Sensor Installation and Maintenance Instructions

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

Flowmeter. Original operating manual DFM

Installation & Operation Manual Proven Quality since 1892

BCV31 DN40 - Blowdown Control Valve

Application Notes for Valve Sizing Sizing valves for steam service with the aid of sizing charts

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

Technical Data Sheet TI-F50 Locking Units series KFH

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Pressure Reducing Valve DMV 750 set range: bar

Transcription:

Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering nipple with ball-type bushing Mounting and Operating Instructions EB 2558 EN Edition August 2014

Definition of signal words DANGER! Hazardous situations which, if not avoided, will result in death or serious injury WARNING! Hazardous situations which, if not avoided, could result in death or serious injury NOTICE Property damage message or malfunction Note: Additional information Tip: Recommended action 2 EB 2558 EN

Contents 1 General safety instructions...4 2 Process medium and scope of application...5 2.1 Transportation and storage...5 3 Design and principle of operation...6 4 Installation...8 4.1 Mounting position...8 4.2 Shut-off valves...8 5 Operation...9 5.1 Start-up...9 5.2 Set point adjustment...9 5.3 Decommissioning...10 6 Maintenance...10 6.1 Changing the set point range...10 7 Customer service...11 8 Nameplate...12 9 Technical data...12 10 Dimensions...13 EB 2558 EN 3

General safety instructions 1 General safety instructions The regulators are to be mounted, started up or serviced by fully trained and qualified personnel only; the accepted industry codes and practices are to be observed. Make sure employees or third persons are not exposed to any danger. All safety instructions and warnings given in these mounting and operating instructions, particularly those concerning installation, start-up and maintenance, must be strictly observed. According to these mounting and operating instructions, trained personnel refers to individuals who are able to judge the work they are assigned to and recognize possible dangers due to their specialized training, their knowledge and experience as well as their knowledge of the applicable standards. The regulators comply with the requirements of the European Pressure Equipment Directive 97/23/EC. The declaration of conformity issued for a regulator bearing the CE marking includes information on the applied conformity assessment procedure. The declaration of conformity is available on request. To ensure appropriate use, only use the regulator in applications where the operating pressure and temperatures do not exceed the specifications used for sizing the regulator at the ordering stage. The manufacturer does not assume any responsibility for damage caused by external forces or any other external factors. Any hazards that could be caused in the regulator by the process medium, operating pressure or by moving parts are to be prevented by taking appropriate precautions. Proper transport, storage, installation, operation and maintenance are assumed. 4 EB 2558 EN

Process medium and scope of application 2 Process medium and scope of application Pressure regulator for cryogenic gases and liquids. Operating pressures up to 50 bar, with set points from 1 to 40 bar. Temperature range from 196 to +200 C. Oxygen clean according to international standards and guidelines. The regulators are designed to keep the pressure constant to the adjusted set point, especially in cryogenic plants. The regulator functions as a pressure build-up regulator with safety function (direction of flow from A to B, closing) or as an excess pressure valve (direction of flow from B to C, opening). WARNING! Risk of injury and property damage due to high pressure in the plant! A suitable overpressure protection must be installed on site in the plant section. 2.1 Transportation and storage The regulators must be carefully handled, transported and stored. Protect the regulators against adverse influences, such as dust, dirt or moisture before they are installed. In the delivered state, the regulators are packed to be free of oil and grease for oxygen service. To avoid contamination, do not open the packaging until immediately before installation. EB 2558 EN 5

Design and principle of operation 3 Design and principle of operation See Fig. 1 on page 7. Depending on the direction of flow, the regulator functions as a pressure build-up regulator with safety function (A B) or as an excess pressure valve (B C). The position of the pressure build-up plug (2.1) determines the flow rate across the area released between the plug and seat. The pressure regulator is designed to keep the pressure constant to an adjusted set point, especially in cryogenic plants. The regulators consists of a valve with three ports (A, B, C), spring-loaded operating diaphragm (3) with set point adjuster (10) and pressure build-up plug (2.1). Pressure build-up regulator Direction of flow from port A to port B. The valve is open when no pressure is applied. The pressure at port B is transmitted to the operating diaphragm (3). The positioning force produced moves the pressure build-up plug (2.1) depending on the spring force adjustable at the set point adjuster (10). The valve closes as soon as the pressure downstream of the valve has assumed the adjusted set point. Pressure build-up regulator with safety function The regulator additionally functions as a safety valve for the pressure chamber upstream of port A. When the pressure exceeds the set point by approx. 5 bar, the positioning force overcomes the force of the closing spring (16), causing the pressure build-up plug to open and the pressure to be relieved to ports B and C. Excess pressure valve Direction of flow from port B to port C. The plug seals off the operating diaphragm (3) when there is no pressure drop across port B and C (valve closed). The pressure at port B is acts on the operating diaphragm (3). The positioning force produced by this pressure opposes the adjustable spring force of the set point springs (8) and opens the tubular plug (2.2) when the pressure rises above the set point by approx. 0.5 bar. The pressures are equalized and the medium escapes through the inside of the plug over port C. The regulator can be optionally equipped with a non-return unit (12). It prevents the medium from flowing back to port C and allows maintenance work to be performed on the regulator without having to empty the tank first. To connect the regulator to the pipelines containing the process medium, soldering nipples with ball-type bushings (17) are available as accessories. EC type examination An EC type examination according to the Pressure Equipment Directive 97/23/EC, Module B has been performed on the regulators. 6 EB 2558 EN

Design and principle of operation C 17 12 1 4.2 16 13 13 A 17 2.1 2.2 5 6 7 Type 2357-31 BB 17 4.1 3 8 9 7 11 10 1 Valve body 2.1 Pressure build-up plug 2.2 Tubular plug 3 Operating diaphragm 4.1 Seal (bottom section of the body) 4.2 Seal (top section of body) 5 Diaphragm plate 6 Ball 7 Spring plate 8 Set point springs 9 Bottom section of the body (spring housing) 10 Set point adjuster (hexagon socket, size 5 mm) 11 Lock nut (size 17 mm) 12 Non-return unit (accessories) 13 Filter 16 Closing spring 17 Soldering nipple with ball-type bushing (accessories) Fig. 1: Functional diagram EB 2558 EN 7

Installation 4 Installation In the delivered state, the regulators are packed to be free of oil and grease for oxygen service. WARNING! Use of oil and grease in oxygen atmospheres! Risk of explosion! Make sure that the regulator is absolutely clean and free of oil and grease on installing it. Flush and clean the pipeline thoroughly before installing the regulator. Make sure the regulator is installed free of stress. Install a strainer upstream of the regulator. Otherwise, impurities in the pipeline may impair the proper functioning of the valve, above all the tight shut-off. 4.1 Mounting position Install the regulator (port C facing upward) with its main axis in the vertical position. Install the pressure regulator with the actuator housing suspended downward. Observe the flow direction. Used as... Build-up pressure regulator with safety function: direction of flow from port A to port B Excess pressure valve: Direction of flow from port B to port C The ports A and B are marked on the body. Required spare parts and accessories are listed in Data Sheet u T 2570 EN. 4.2 Shut-off valves We recommend installing a hand-operated shut-off valve both upstream and downstream of the regulator. This allows the plant to be shut down for cleaning and maintenance, and when the plant is not used for longer periods of time. Install a pressure gauge at a suitable point to monitor the pressures prevailing in the plant. Pressure gauge Type 2357-31 Fig. 2: Typical application 8 EB 2558 EN

Operation 5 Operation See Fig. 1 on page 7. 5.1 Start-up First start up the regulator after mounting all parts. 5.2 Set point adjustment Every pressure regulator is delivered with the set point listed in Table 1 already adjusted. Set point adjuster Turn the set point adjuster (10) using Allen key (width across flats 5 mm) to change the default set point. Provided a pressure gauge has been installed at a suitable point in the plant, the required set point can be directly adjusted while monitoring the pressure reading at the gauge. When a pressure gauge is not installed, adjust the set point using the adjustment diagram Fig. 3 on page 10. To increase the set point, turn the set point adjuster into the body ( ) and out of the body ( ) to reduce it. NOTICE! Set point adjuster screwed too tight! The regulator is blocked and the medium flow through it is restricted. Pressure regulation is no longer possible! Only screw the set point adjuster up to the point where the spring tension can still be felt! How to proceed: 1. Loosen the lock nut (11, width across flats 17 mm) to allow the set point adjuster to move freely. 2. Determine the difference between the fixed set point (Table 1) and the required set point. Turn the set point adjuster (10) the required amount of turns as specified in Fig. 3. Based on the default setting, any subsequent change to the set point can be also be made by determining the required number of turns using the specifications listed in Table 1. 3. Lock the setting with the lock nut (11). Table 1: Set point adjustments (default settings) Set point range 1 to 8 bar 5 to 25 bar 8 to 40 bar Adjusted to... 3 bar 12 bar 25 bar Set point change per turn 1 bar 2.5 bar 3.5 bar EB 2558 EN 9

Maintenance 40 35 30 25 20 15 10 Set point in bar 5...25 bar 8...40 bar 6 Maintenance The regulators do not require any maintenance. Nevertheless, they are subject to natural wear, particularly at the seat, plug and operating diaphragm. Depending on the operating conditions, check the regulator at regular intervals to avoid possible malfunctions. WARNING! Process medium can escape uncontrolled on dismantling the regulator. Risk of cold burns! Allow the regulator to defrost before depressurizing and draining it and remove it from the pipeline. 5 0 0 1 2 3 4 5 6 7 8 9 1011121314 Turns of the set point adjuster : to increase the set point : to reduce the set point Fig. 3: Adjustment diagram 5.3 Decommissioning 1...8 bar Close first the shut-off valve on the upstream side of the valve and then on the downstream side of the valve. Check the filters in ports A and B for dirt and, if necessary, clean them. If faults or malfunctions cannot be remedied, contact SAMSON (see section 7). 6.1 Changing the set point range The set point ranges adjusted in the factory can be changed by changing the set point springs (8) and operating diaphragm (3) (u T 2570 EN Spare parts and accessories). 10 EB 2558 EN

Customer service How to proceed: 1. Loosen lock nut (11) and completely relieve the tension from the set point springs (8) by turning the set point adjuster (10) counterclockwise. 2. Place the lower section of the body (9) into a vise, but do not clamp it. Preferably use a box wrench (size 55 mm). Unscrew the body (1) using an open-end wrench (size 36 mm) and remove all parts from the lower section of the body. Be careful not to damage the operating diaphragms (3). 3. Place set point spring(s) for the required set point range, spring plate (7), ball (6) and diaphragm plate (5) into the lower section of the body. 4. Place the required number of diaphragms onto the diaphragm plate. Replace the PTFE gasket (4.1) of the valve body, if required. 5. Carefully place the body onto the lower section of the body. Tightening torque approx. 250 Nm 7 Customer service If malfunctions or defects occur, contact the SAMSON After-sales Service Department for support. The addresses of SAMSON AG, its subsidiaries, representatives and service facilities worldwide can be found on the SAMSON website (u www.samson.de), in all SAMSON product catalogs or on the back of these Mounting and Operating Instructions. Please send your inquiries to: service@samson.de To assist diagnosis and in case of an unclear mounting situation, specify the following details (see section 8): Type designation with index K VS coefficient Upstream and downstream pressure Customer-specific details Temperature and process medium Min. and max. flow rate Is a strainer installed? Installation drawing showing the exact location of the regulator and all the additionally installed components (shut-off valves, pressure gauge, etc.) EB 2558 EN 11

Nameplate 8 Nameplate 1 2 3 Details on lower section of body 1 Set point range/date of manufacture 2 Type designation with index 3 Customer-specific details CE compliance Fig. 4: Nameplate details 9 Technical data Type 2357-31 Process medium in the gas state Nominal pressure PN 50 K VS coefficient Pressure build-up Pressure reduction Set point range Max. permissible operating pressure Safety function Excess pressure function Heat leak Filling the tank 0.8 0.2 1 to 8 bar 5 to 25 bar 8 to 40 bar 50 bar 5 bar above the set point Approx. 0.5 bar above the set point Approx. 5 bar above the set point Temperature range 196 to +200 C Weight, approx. Connections 3.5 kg A, B M40 x 2 C M26 x 1.5 Non-return unit M26 x 1.5/M40 x 2 12 EB 2558 EN

Dimensions 10 Dimensions 126 M40 x 2 296 63 180 M26 x 1.5 M40 x 2 M40 x 2 203 Ø 80 174 Type 2357-31 Version with soldering nipple (accessories) and non-return unit (accessories) Fig. 5: Dimensions in mm EB 2558 EN 13

14 EB 2558 EN

EB 2558 EN 15

SAMSON AG MESS- UND REGELTECHNIK Weismüllerstraße 3 60314 Frankfurt am Main, Germany Phone: +49 69 4009-0 Fax: +49 69 4009-1507 samson@samson.de www.samson.de EB 2558 EN 2014-09-16 English