MASSIVE TITANIUM SUBLIMATION PUMPING IN THE CESR INTERACTION REGION *

Similar documents
Resist round robin ELETTRA

The Principles of Vacuum Technology

Outgas of Methane from NEG Coating

Achieving Ultra-High Vacuum without (in-situ) Bakeout

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

Issues Confronting Vacuum System Design for e+e- Storage Rings

The Gas Attenuator of FLASH

Vacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007

Numerical Tools for LCLS-II Vacuum Systems

Gun Vacuum Performance Measurements February 2003

LCLS Heavy Met Outgassing Tests * K. I. Kishiyama, D. M. Behne Lawrence Livermore National Laboratory

Practical approach and problems in in-situ RGA calibration

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

Development of Cleaning and Processing Techniques for UHV/XHV at Daresbury Laboratory Keith Middleman

Particle Control under Wall Saturation in Long-pulse High-density H-mode Plasmas of JT-60U

Relative Dosimetry. Photons

Vacuum Simulations of the KATRIN Experiment

Vacuum System at IUAC

Residual Gas Analysis Systems for Industry

OOC RGA. Ion Pump 400 l/s. 8" ports with baked viton o-ring seals. Welsh rotary roughing pump 650 l/s manual isolation valve.

How To Use Getters and Getter Pumps

DC gun high voltage conditioning with Krypton gas Carlos Hernandez-Garcia October 2008

A novel class of Non Evaporable Getter (NEG) alloys with lower hydrogen equilibrium pressure and reduced outgassing properties

Canadian Light Source Inc. Vacuum Component Leak Test Technical Procedure

Total Pressure Measurement Using Residual Gas Analyzers

The Discussion of this exercise covers the following points:

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Procedure of Xenon Transfer

Contamination Removal of EUVL masks and optics using 13.5-nm and 172-nm radiation

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01

Helium Mass Spectrometric Leak Detection In Large Size Process Plants

The Experts in Vacuum Solutions

Leak Detection. Kirsten Zapfe, DESY CAS Vacuum in Accelerators Platja D Aro, May 21, Special thanks to S. Holm, N. Mildner and A.

Choosing a Quadrupole Gas Analyzer Application Note #9

at NIST: ultra-low outgassing rates

Vacuum acceptance tests for particle accelerator equipment

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

1. The principle of fluid pressure that is used in hydraulic brakes or lifts is that:

Dr. José Miguel JIMENEZ CERN, Technology Department Head of the Vacuum, Surfaces and Coatings group

Development of high pressure-high vacuum-high conductance piston valve for gas-filled radiation detectors

The Helium Leak Detector

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.

Development of a high vacuum sample preparation system for helium mass spectrometer

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Detecting Hydrogen in Helium Streams. Samuel Goodman. Pittsford Mendon High School. Rochester, New York. Advisor: Dr.

REPRODUCIBILITY IN OPTICAL THIN FILM PROCESSING PART 1, THE VACUUM AND PUMPING

The Broadest Gauging Line in the Industry

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

IUVSTA WORKSHOP WS-63 Surface Phenomena Limiting Pressure in Vacuum Systems REPORT TO IUVSTA. prepared by JOSÉ L. DE SEGOVIA

OP CHECKLIST FOR 1D CONSOLIDATION LABORATORY TEST

Go/no-go test for the acceptance of components for unbaked vacuum sectors

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

Oxygen Contamination

Low-Power Atmospheric Gas Sampling System Based on ART MS Sensor and NEG-Ion Pump

SPIRIT III Radiometer Saturation Effect

COMMISSIONING OF RHIC VACUUM SYSTEMS*

Name /74. MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

Wind tunnel tests of a non-typical stadium roof

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Chapter 8: Cryo-sorption pumps

WIND-INDUCED LOADS OVER DOUBLE CANTILEVER BRIDGES UNDER CONSTRUCTION

Review of fundamental photon dosimetry quantities

CTB3365x Introduction to Water Treatment

ETCHING OF COPPER COATED MYLAR TUBES WITH CF4 GAS. Karl M. Ecklund, Keith W. Hartman, Michael J. Hebert, Stanley G. Wojcicki

ACCELERATOR VACUUM PROBLEMS: IN-LINE OIL TRAPPING BETWEgN THE STANFORD LINEAR ACCELERATOR AND THE BEAM SWITCHYARD

You should be able to: Describe Equipment Barometer Manometer. 5.1 Pressure Read and outline 5.1 Define Barometer

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Vacuum Science and Technology in Accelerators

ANL/APS/TB-16 ADVANCED PHOTON SOURCE ACCELERATOR ULTRAHIGH VACUUM GUIDE. Chian Liu and John Noonan

Investigation of Suction Process of Scroll Compressors

CHEM 3351 Physical Chemistry I, Fall 2017

Aalborg Universitet. Published in: Proceedings of Offshore Wind 2007 Conference & Exhibition. Publication date: 2007

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

User s Manual Differential Pump

Improving the Measurement Accuracy of Water Partial Pressure Using the Major Constituent Analyzer

THE development of more advanced techniques in radiotherapy,

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

Quadruple mass spectrometers (transducer type)

arxiv: v1 [physics.ins-det] 16 Aug 2014

CHEMISTRY - CLUTCH CH.5 - GASES.

CHAPTER 7 : SMOKE METERS AND THEIR INSTALLATIONS

Laser-Induced Bubbles in Glycerol-Water Mixtures

Characterizing a Cu/Mn Alloy for Extracting Oxygen from Inert Gas. Streams

End of Chapter Exercises

Measuring mass flows in hermetically sealed MEMs & MOEMs to ensure device reliability

-6- THE DIII-D MAGNETIC FUSION TOKAMAK OUTGASSING TESTS ON MATERIALS USED IN. KaLm HOLTROP, M. HANSINK, and AmGm KELLMAN DECEMBER 1998 ATOMICS GENE-L

LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY

Resist Outgassing and its Role in Optics Contamination

Ultrahigh Vacuum in Superconducting Synchrotrons A.Smirnov, JINR, Dubna, Russia

Single and Canted Undulator Front-Ends

EFFECTS OF BAFFLE SIZE ON PRESSURE DISTRIBUTION IN VACUUM CHAMBER DURING DYNAMIC GAS FLOW

Extreme High Vacuum: The Need, Production, and Measurement

Flow in a shock tube

Chemistry 20 Unit 2 Gases FITB Notes. Topic A Characteristics of Gases

Chapter 5. Nov 6 1:02 PM

SHMS. Downstream Beamline. Large SHMS/HMS Angles (Config-1) Large SHMS / Min HMS Angle (Config-2) Dan Young Ext /26/2015 1

Old-Exam.Questions-Ch-14 T072 T071

Ch. 11 Mass transfer principles

Transcription:

MASSIVE TITANIUM SUBLIMATION PUMPING IN THE CESR INTERACTION REGION * N.B. Mistry, R. Kersevan and Yulin Li, Laboratory of Nuclear Studies, Cornell University, Ithaca, NY 153 USA Abstract * The residual gas pressure within 30 m of the interaction point (IP) at the e ± collider CESR is maintained in the low nanotorr range despite the high gas loads produced by the intense flux of synchrotron radiation from the electron and positron beams. A low pressure is necessary in order to minimize the experimental backgrounds due to beam gas scattering. Within 1 m of the IP, the vacuum chambers incorporate large pumping plenums with massive titanium sublimation pumping to provide the necessary pumping speed and capacity. Operating experience over the last two years has shown that this method of pumping is efficient and inexpensive. 1. INTRODUCTION. Lost particles generated by the 5.3 GeV e ± beams in the collider CESR interacting with the residual gas are a major source of background in the CLEO High Energy Physics detector. They could also lead to radiation damage of sensitive components such as the new Silicon Vertex Detector (SVX) electronics installed around a two-centimeter radius thin beryllium beampipe.[1] An aggressive R&D program to increase the luminosity of CESR has led to successive upgrades of the storage ring, which is now producing peak luminosities of x 3 cm - s -1 at a beam energy of 5.3 GeV, well beyond its original design specification. The main objective of the 1995 upgrade to Phase-II was to allow storage of up to 300 ma per beam. Increased current produces increased desorption of gases by synchrotron radiation (SR), so that the beam-gas background in the detector could increase proportional to the square of the current if the pressure were allowed to increase in proportion. The detector at the interaction point (IP) is most sensitive (in the present optics) to lost particles produced by beam-gas bremssstrahlung in the region up to about 30 m from the IP. The region up to 1 m was in particular need of increased pumping, to keep the pressure below about ntorr at 300 ma. For Phase-II, the vacuum chambers from the IP up to 1 m were replaced by new chambers, most of them incorporating massive titanium sublimation pumping () plenums. The secret to maintaining high distributed pumping speed is, of course, large conductance to the pumping surfaces. The SR fans are * Work Supported by the National Science Foundation Presented at PAC 97, Vancouver, B.C., May 1997 absorbed on water-cooled copper bars and highconductance slots lead to the pumping surfaces lining the plenum in each chamber. Right after flashing fresh Ti, the sticking coefficient is about 0.7 for CO. The net pumping speed is dominated by the slot conductance and gradually decreases as the Ti surface saturates. The speed is quite appreciable even when the sticking coefficient has fallen to 0.1. However, we flash again when the operating pressure with beams is about ntorr. There is another factor that affects the dynamic pressure rise and the flashing interval. It is well known[] that the SR induced desorption coefficient η SR decreases steadily from its initial high value after intervention. Thus the dynamic pressure rise, dp/di, expressed in ntorr per ma of beam, continues to decrease with beam dose D, expressed in Amp-hours and correspondingly, the flashing interval increases steadily. Eventually, we find that η SR levels off due to the overall equilibrium between desorption and readsorption of the molecules on the cleaned surfaces during steady operation at a particular beam current. This particular phenomenon has also been observed directly as wallpumping, contributing very significant distributed pumping in regions of intense SR flux. The variation in desorption yield at any given location is well described by a power law η SR =η in D α, with α of order 1. The initial yield, η in, immediately after start up of the accelerator can be as high as 0.1 molecule/photon and η SR reaches values as low as x - mol/photon after exposure to photons/m.. CHAMBERS NEAR THE INTERACTION REGION. Immediately surrounding the IP is a 50 cm long, cm radius double-walled thin beryllium beampipe. A silicon vertex detector, the most sensitive part of the detector, surrounds this pipe. The first pump is the Q1 pump at.3 m from the IP. Figure 1 shows two views of the cross-section. The tapered, slotted beam-pipe incorporates water-cooled copper absorber bars in the horizontal plane and is surrounded by a 0 cm radius plenum. The total conductance of the slots leading to the plenum is 0 l/s for N. Three Ti-sublimation cartridges, each with three filaments, are installed on demountable conflat flanges, baffled from each other and from direct line-of-sight to the beam tube. The next pump is a 0 l/s noble-diode sputter-ion pump (SIP) at m. This serves to keep the partial pressure of noble gases

and methane in control. It should be remarked here that although there is methane desorbed by the beam, the intense photon and electron flux is efficient at cracking methane (CH ) to CH 3 and H which are then pumped by the, so that no buildup of CH is observed. Beam Chamber Gauge Port conductance of the pumping slots and holes between the beam-chamber and the pumping plenum is about 9,000 l/s. A CCG is installed on top of the pumping plenum. A 0 mm diameter port for an additional 500 l/s sputter-ion pump is located on the tapered part of the SS chamber. 3.33 m Pumping Plenum Cartridge Beam Line Titanium Plenum Cartridges Ion Pump Figure 3. The Soft-Bend Chamber. Top view (above) and cross-section showing Ti pumping plenum. Pumping Holes Water Cooling 31 mm Dia. Figure 1. The Q1 titanium pump chamber. Above, view along beam. Below, cross-section looking down. Beam Line Cartridges.3 m 00 mm Pump Port Figure. The ISP Chamber with Ti pumping plenum. Figure shows the ISP chamber which occupies the region from. m to about. m. From the end nearest the IP, it consists of a section of 1 m long copper beam chamber with pumping slots and holes surrounded by a cylindrical pumping plenum of 0. m diameter. This is followed by a 1 m long section of tapered stainless steel chamber, of rectangular cross section. The two sections share a.1 m long water cooled copper absorber bar on one side which absorbs SR from the outgoing beam. A separate short 0.3 m long angled water-cooled absorber is on the opposite side to absorb the more intense flux from the incoming beam. The 1 m long pumping plenum has three Tifilament cartridges. A total surface area of about,000 cm is covered by Ti during flashing. The total Figure 3 shows the 3.3 m long Soft-Bend vacuum chamber, which is inserted in the first bend magnet of ρ= m bend radius. This chamber sees the intense SR radiated by the incoming beam in the high field Hard Bend (HB) magnets of ρ= 33 m upstream. The absorber is a 3. m long copper bar bent to a chevron shape, with wedge-shaped absorbing steps, designed to prevent reflected SR photons from reaching the sensitive region of the IP. The wedges also serve to concentrate the SR flux resulting in faster clean-up due to increased photon dose per Amp-hour of beam. Two flat stainless-steel plates serve as top and bottom of the beam chamber, leading to a large rectangular copper pumping plenum, 15 cm high by 5 cm wide running the full length of the chamber. Nine vertical baffles give rigidity and increase the surface covered by titanium. A slotted wall of about 7,00 l/s conductance separates the rectangular beam chamber from the pumping plenum. A total surface of approximately 5,000 cm on the pumping plenum and the baffles is covered by Ti during flashing. Eight Ti-filament cartridges are equally spaced in the pumping plenum. A 1 l/s noble-diode sputterion pump is mounted on the bottom of the pumping plenum. A CCG is installed on the pumping plenum near the beam line. TABLE I. Synchrotron Radiation Flux and Gas Load in the CESR IR for 300 ma e ± Stored Beams. Location Flux Density Total Flux CO GasLoad (Photon/s/m) (Photons/s) [Torr-l/s] Q1-Pump 1.3 1.5 17 7.9 - ISP absorb. 1.1 19 1.9 1.0-7 Soft-Bend 3.3 1 3.5 1.7-7 Hard-Bend.9 1.3 19 1.3 - An estimate of the CO gas load obtained when the photodesorption yield in the HB region of most

intense flux gets down toη 0 = 1. - mol/photon is given in the last column of Table 1, which lists typical linear SR flux, total flux and gasloads in different regions of the IR. We use this ultimate value of η SR to predict the vacuum performance of CESR when the vacuum system is fully conditioned, and it is used to model pressure profiles below. 3. MEASUREMENTS OF PUMPING SPEED AND CAPACITY. Each pumping chamber, after fabrication, was subjected to the following procedures in the laboratory, before installation in CESR: leak check followed by bakeout for hours at 150 o C minimum; degassing of all Ti filaments and gauges; saturation of the bare walls with either CO or N using calibrated leaks; flashing of successive Ti cartridges and measurement of base pressures; slow saturation of the Ti surface using CO and/or N calibrated leaks with continuous monitoring of pressure and gas composition. The effective pumping speeds at each stage was determined from the data. A fresh 1 l/s ion pump was attached to the apparatus, in order to keep inert gas partial pressures under control. However, the position of the installed leak at one end of the long chambers did not quite represent the final configuration of beam-induced gas sources in CESR. N Pumping Speed (l/s) 3 0.001 0.01 0.1 1 N Gas Load (torr-l) Figure. N Pumping Speed, Soft-Bend Chamber. The experience obtained with the Soft-Bend chamber is quite illustrative and typical. After bakeout and degassing of filaments, initial pumping speeds of the bare walls were S N = 957 l/s and S CO =,00 l/s! Significant partial pressure peaks of CH 3, CH and Argon showed clear evidence of passive gettering action. The bare chamber walls absorbed a dose of 0.9 torr-liter of nitrogen. After flashing all eight Ti -cartridges for minutes each at 0 W, the pumping speeds for CO and N were measured as a function of N load. Initial pumping speeds at zero load were: S N = 1,571 l/s and S CO =,0 l/s. This ratio is representive of the much higher initial sticking coefficient for CO, as well as the fact that two Ti atoms are required per N molecule and only one per CO molecule. Figure shows the N pumping speed versus nitrogen load. After absorbing. torr-liters of N the CO pumping speed was still as high as 3,500 l/s and decreased to 1,500 l/s after 0. torr-liter of CO was absorbed. We did not have the time to saturate the Ti with CO with the. x - torr-l/s gas-leak available. CO Pumping Speed (l/s) 3 0.001 0.01 0.1 1 CO Gas Load (torr-l) Figure 5. Pumping Speed in the Q1 chamber. Figure 5 shows the saturation of the Q1 pump chamber with a large CO gas-leak of. x -5 torrl/s. The pumping speed falls by five at about 0. torrl/s. In CESR, this is a region of low SR gasload, x - torr-l/s with 300 ma beams. This suggests that the ultimate flashing interval for Q1 should be about 90 days. RGA Reading (Amps) - -7 - -9 - -11-1 -13 CCG: (Torr) amu amu amu 0.0 0.5 1.0 1.5 Absorbed Gas QCO (Torr-liters) Figure. Saturation of the ISP chamber with CO gas. The CCG pressure is on the same axis scale, in Torr..0 Figure shows the saturation curves for the ISP chamber using the same large CO gas leak. A turbo 3

pump (0 l/s effective speed) was used to pump inert gases. Significant saturation of the Ti surface occurs at about 1.0 torr-liters of CO. The ultimate SR-induced gasload at 300 ma per beam is expected to be about x -7 torr-l/s, so we expect a flashing interval of about 0 days to maintain pressures below a few nantorr.. DYNAMIC PRESSURE RISE IN CESR. The new IR chambers were installed and CESR operation in PhaseII was started in November 1995. The dynamic pressure rise with beam, (dp/di ), at various locations in the IR is shown in the Figure 7 as a function of beam dose in Amp-hrs. Single beam dose is used where only one beam induces outgassing and total beam dose for chambers where both beams produce a gas load. The points when Ti-flashing occured are indicated (triangles) and the subsequent points show the slow saturation of the. The plots include data recorded up to March 3, 1997, representing approximately 1 months of operation, including a few periods of down time. -1 - -3-1 - -3 (a) CCG(Q1) data Ti-flashing 0 Single Beam Dose (A Hr) (b) CCG(ISP) data ing 0 Single Beam Dose (A Hr) - -3-0.1 0.01 1 (c) CCG(SB3) data ing 0 00 Total Beam Dose (A Hr) dp/di=0.0077+0.3 D tot -0.9 (d) CCG(CH5E) data 0 Total Beam Dose (A Hr) Figure 7. The beam induced dynamic pressure rise, (dp/di ), at various locations in the IR. (a) The dynamic pressure rise at Q1E; (b) a similar plot for a gauge on the beamline next to the ISP chambers, and (c) for the soft-bend chambers. (d) shows a similar plot for a gauge within the hard-bend sector pumped only by distributed ion pumps (DIPs), but where the SR flux and gas load is the most intense. The clean-up due to the beams is very apparent in all plots and shows the characteristic dose dependence of the gas load, N gas =N phot ( η 0 +εη in D α ), with α 1 for all plots. Here ε is the fraction of photons scattered from the primary SR stripe which is assumed to have reached the ultimate low coefficient η 0. The scattered photons then continue to clean up the rest of the chamber. In the high-intensity HB region (Figure 7d) we see that after about 0 Amp-hrs of total beam, the falling dynamic pressure rise has levelled off to N phot η 0. This levelling off indicates the equilibrium between desorption by the beam and readsorption by the cleaned surfaces, leading to a constant effective η SR. The effective desorption level for the different gases is being evaluated from recent spectra. The excursions from the curve in Figure 7d show the recovery after interventions. The two large

excursions recovered in 35 A-hrs (3 days) and 1 A- hrs respectively. The first was a planned intervention with pure N backfilling. The second was an accident in an x ray beam line, to tunnel air and took much longer to recover. With the aid of a Monte-Carlo (MC) simulation program[3] we have modeled the vacuum system in the IR, using reasonable estimates for the sticking coefficient of the Ti films and the pumping speed of the noble-diode sputter-ion pumps. Figure shows the calculated profile of the beam induced pressure rise on the beam line, P(s), and the measured values obtained during an HEP run with 9 ma e and 1 ma e +, together in CESR.. REFERENCES. [1] S.Henderson, The CESR High Luminosity IR, these Proceedings. [] O.Groebner et al., Vacuum 33, 397 (193). [3] R. Kersevan, MOLFLOW, a 3D Monte-Carlo Code for the simulation of molecular flow, available from the author, Laboratory of Nuclear Studies, Cornell University, Ithaca, NY, 153. -7 Pressure Rise (Torr) - -9 - -11 0 P_measured. P_calc. P(s) at 0 A-hrs. P(s) at 00 A-hrs. 00 00 Distance from I.P. (cms) 0 Figure : The calculated profile of the beam induced pressure rise on the beam line, P(s), and the measured values obtained during an HEP run with 9 ma e and 1 ma e + in CESR. Note that the P measured and calculated for gauges at Q1(at 50 cm) & SoftBend (at 0 cm) are much lower than the curve as the CCGs are not installed directly on the beam chamber, but rather on the pumping plenums. The solid curve refers to an early stage of conditioning, after a beam dose of 0 Amp hrs. The dotted pressure profile is for 150 ma e ± beams after 00 A-hrs of running. 5. CONCLUSIONS. Ti sublimation pumping on an extensive scale has been used successfully in the interaction region of CESR, to keep pressures at a few nantorr level despite the intense SR flux. Present operation of CESR with two beams of 150 ma each results in operating pressures of between 1.5 ntorr and 3.5 ntorr in most of the IR. This pressure profile is sufficient to keep detector backgrounds at acceptable levels. In the near future, we will install more chambers similar in design to the soft-bend chambers further down the line in the bend region. We expect the pressures to be maintained at the low nanotorr level as the beam currents are raised to 300 ma and beyond. 5