Optical Time Domain Reflectometer. Operating System 2 Windows XPe Windows XP Pro with desktop option 256 MB

Similar documents
CMA4000 Specifications

GN NetTest CMA4000 CMA4453M Specs Provided by VGA LCD Display (21.3 cm (8.4 inch) color or 20.8 cm (8.2 inch) monochrome)

Genesis MX SLM-Series

Additel 761 Automated Pressure Calibrators Selection Guide

Pneumatic high-pressure controller Model CPC7000

Verdi G-Series. High-Power Pumps for Ti:Sapphire Lasers and Amplifiers FEATURES

Pneumatic high-pressure controller Model CPC7000

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

Verdi G-Series Family

Additel 761 Automated Pressure Calibrators

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

PTP 800 SPLIT-MOUNT SOLUTION

INTRODUCING CARDIOSAVE Hybrid MORE THAN A PUMP. A REVOLUTION. SPECIFICATIONS

Additel 780 Series Pressure Controller

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Differential Probes TDP1500 and TDP3500 Datasheet

MOTOROLA PTP 800 LICENSED ETHERNET MICROWAVE

AIR FLOW CALIBRATORS Single Sensor Designs

ADT 761 Automated Pressure Calibrator

Additel 761 Automated Pressure Calibrators

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

Code Basic module and level control complete with optionals code

Additel 780 Series Pressure Controller

Rimage Everest 600 Thermal Retransfer Printer

BUYER S GUIDE AQUAlogger 530WTD

Heavy Duty Dissolved Oxygen Meter

Digital Pressure Gauge Main features: Data Sheet: BIT02B.417.R6.EN COVER on request

ST Connectors & Adapters

About us. Try us to trace your network!

Columbus Instruments

SAUTER FK Version /2016 GB

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

SVEA II GSM Connector User Manual

EUROPEAN pr I-ETS TELECOMMUNICATION September 1995 STANDARD

DCS Series 1 kw, 1.2 kw, & 3 kw

Panther 5 Acute Care Ventilator

Doppler current meter

STAND alone & p.c. VERSION

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

Digital deadweight tester Model CPD8500

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

DOS in Food Science & Nutrition, Manasagangotri, Mysore

Portable Gas Analyzers

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

HI 2314 HI 2315 HI 23151

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

Portable oxygen concentrator

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Oil Diagnostic Systems. Online and bottle measurement Mobile and stationary operation Lab quality accuracy e

DANAGE TIMER System Controller User Manual

FL200 Monochromatic Architectural Spot and Floodlight

Optical Dissolved Oxygen Meter

Drag racing system HL190 User Manual and installation guide

Your local gas generation partner. Precision series Modular gas generation solution for GC.

AR740 RPS Redundant Power Supply Quick Install Guide

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Operating Manual. BACVis. Manual BACVis. for. Sensors and MilliGascounter. Rev

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

RM-80 respiration monitor

Blood Parameter Monitoring System 550

GasSense NDIR User Manual

OPCom With laser diode Measurement range 4, 6,14 and 21 µm(c) Operating pressure up to 500 bar

AUTO RANGE Display of maximum measurable limits. Displayed Info Viscosity (cp or mpa s) % Torque Spindle Speed

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

Everest XLG3 VideoProbe

Biconic Connectors and Accessories

Optical Dissolved Oxygen Meter

Fibre Selection Guide

Technical Information Conducal CLY421

Oxylog VE300 Emergency & Transport Ventilation

Digital dead-weight tester Model CPD8500

5) Match timer: Hanged on the court, display the match time synchronous with scoring system.

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

h2000 plus HyDROGEN LEAk DETECTOR

Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply

TYMP Technical data. at 85, 95 und 105 db HL. 2. detailed display symbols

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

BUDDY Gorgeous and easy to use GPS Navigation Kit USER GUIDE. Love from Intempo Digital xx

SPECIFICATIONS PARTICLE SENSOR KS-19F Higashimotomachi, Kokubunji, Tokyo , Japan

NEW: CO2 incubator with sterilizable sensor

Description. Chassis. Cabinet. Long chassis - Type: Dimensions (mm): 2700 x 1200 x 1678

NEW: CO2 incubator with sterilizable sensor

UltraFill meets the d

WELCOME TO THE REVOLUTION

QUANTIFIT....the gold standard in respirator fit testing. Product Information Brochure

Manual Weighingblock VB2 series and Uniscale

HumiSys HF High Flow RH Generator

SonoMeter 30 Energy Meters

Additel 780 Series Pressure Controller

UNDERSTANDING, ACCELERATED

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

A Closer Look at Fiber Optic Cable Assemblies

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Portable Oxygen Concentrator. Give your patients more freedom with mobile oxygen on demand

Transcription:

CMA 4500 Series Optical Time Domain Reflectometer The CMA 4500 continues NetTest s tradition as the industry s premier OTDR solution designed with the high performance and scalability necessary to meet the stringent demands of telecommunications professionals, while simultaneously accelerating the deployment of new services and reducing the total cost of measurement. Specifications Standard Desktop Operating System Windows XPe Windows XP Pro with desktop option Data I/O (modular) CD-R/W (optional) CD-R/W (standard) 3.5".44 MB floppy drive (optional) 3.5".44 MB floppy drive (optional) Data I/O (fixed) Processor 0 GB hard drive minimum (standard) Ultra-low power 300 MHz NOTES: All specifications subject to change Although Windows is the platform operating system, it is not accessible unless the desktop model is ordered System Memory Display Control Interface 56 MB Touch screen, 6.4 cm (0.4") XGA LCD (04 x 768 pixel resolution) Touch screen, cursor control, dedicated hardkeys and status LEDs Standard I/O Ports USB (), Ethernet 0/00(), IrDA (), PS/ Mouse (), PS/ Keyboard () Dimensions (H x W x D) Weight 4. x 34.3 x 9.5 cm (9.5 x 3.5 x 3.75 inches) 5.4 kg ( lbs) includes battery Power Specifications AC Battery Battery Life Recharge Time Auto switching 9-3 VAC 47-63 Hz, 84-64 VAC 47-63 Hz Li-Ion - battery standard >3 hours <3 hours Environmental Specifications Operation Storage Temperature 0º to 45º C (3º to º F) -5º to 60º C (-3º to 40º F) Humidity 95% max, non-condensing 95% max, non-condensing Altitude 5,40 m (50,000 ft) 5,40 m (50,000 ft) Specifications

CMA 4500 Series OTDR Specifications - (Single Wavelength Available upon request) 5 35 45 54 30 nm ±0 nm 550 nm ±0 nm 30 nm ±0 nm 550 nm ±0 nm 30 nm ±0 nm 550 nm ±0 nm 550 nm ±0 nm 30 nm: <5 nm 550 nm: <5 nm 30 nm: <5 nm 550 nm: <5 nm 30 nm: <5 nm 550 nm: <5 nm 550 nm: <5 nm Dynamic Range 30 nm: 37 db 550 nm: 36 db 30 nm: 40 db 550 nm: 40 db 30 nm: 43 db 550 nm: 45 db 550 nm: 50 db Deadzone 30 nm: 4 m 550 nm: 3.5 m 30 nm: 4 m 550 nm: 3 m 30 nm: 5 m 550 nm: 5 m 550 nm: 5 m 30 nm: 9 m 550 nm: 9 m 30 nm: 8 m 550 nm: 6 m 30 nm: 0 m 550 nm: 0 m 550 nm: 0 m SNR= with up to 56k averages (typical, subtract approximately db of range to 98% peak noise. Bellcore TR-TSY-00096 Issue ) Using Bellcore TR-TSY-00096 Issue (typical) 3 Deadzones measured on -45 db reflections (typical) 4 Wavelength dependent 5 66 and 69 Distance Range is 5, 0, 50, 5 km 6 66 and 69 Distance Sampling is 0.5, 0.5, 0.5,,, 4, 8 m Pulsewidth Dynamic Range Deadzone 5 ns to 0 µs 36 30 nm ±0 nm 550 nm ±0 nm 65 nm ±5 nm 30 nm: <5 nm 550 nm: <5 nm 65 nm: <5 nm 30 nm: 40 db 550 nm: 40 db 65 nm: 40 db 30 nm: 4 m 550 nm: 3 m 65 nm: 3 m 30 nm: 8 m 550 nm: 6 m 65 nm: 6 m 5 ns to 0 µs 46 30 nm ±0 nm 550 nm ±0 nm 65 nm ±5 nm 30 nm: <5 nm 550 nm: <5 nm 65 nm: <5 nm 30 nm: 43 db 550 nm: 45 db 65 nm: 43 db 30 nm: 6 m 550 nm: 5 m 65 nm: 5 m 30 nm: 0 m 550 nm: 0 m 65 nm: 0 m 66 Multimode (6.5 µm) 300 nm ±30 nm 850 nm: <5 nm 300 nm: <5 nm 850 nm: 4 db 300 nm: 6 db 850 nm:.5 m 300 nm:.5 m 300 nm: 7 m 69 Multimode (50 µm) 300 nm ±30 nm 850 nm: <5 nm 300 nm: <5 nm 850 nm: 4 db 300 nm: 6 db 850 nm: 3 m 300 nm: 3 m 300 nm: 7 m Pulsewidth 4 5 ns to 0 µs 5 ns to µs 5 ns to µs Distance Resolution 0.000 km, 0. m, ft, 0.000 mi Distance Range Setting 4, 5 5, 0, 50, 5, 50, 300 km Loss Resolution 0.00 db Distance Sampling 4, 6 (Range Dependent) 0.5, 0.5, 0.5,,, 4, 8, 6 m Data Points Up to 56,000 Distance Accuracy Laser Safety 0.005% of distance measurement ± distance resolution ± index uncertainty Meets IEC6085- Class I and CDRH Class Requirements (Eye Safe) CFR 040 Universal (Uses UC-30-XX adapters) Page of 5 CMA 4500 OTDR Specification

CMA 4500 Series OTDR Specifications Dynamic Range Deadzone 6 30 nm ±0 nm 550 nm ±0 nm 30 nm: <5 nm 550 nm: <5 nm 30 nm: 35 db 550 nm: 35 db 30 nm: 5 m 550 nm: 5 m 30 nm: 0 m 550 nm: 0 m Multimode (6.5µm) 300 nm ±30 nm 850 nm: <5 nm 300 nm: <5 nm 850 nm: 4 db 300 nm: 6 db 300 nm: 5 m 850 nm: 7 m 300 nm: 8.5 m SNR= with up to 56k averages (typical, subtract approximately db of range to 98% peak noise. Bellcore TR-TSY-00096 Issue ) Using Bellcore TR-TSY-00096 Issue (typical) 3 Deadzones measured on -45 db reflections (typical) 4 Wavelength dependent 5 66 and 69 Distance Range is 5, 0, 50, 5 km Pulsewidth Distance Resolution Distance Range Setting 4, 5 Loss Resolution Distance Sampling 4, 6 (Range Dependent) 0.000 km, 0. m, ft, 0.000 mi 5, 0, 50, 5, 50, 300 km 0.00 db Data Points Up to 56,000 Distance Accuracy Laser Safety 5 ns to 0 µs 0.5, 0.5, 0.5,,, 4, 8, 6 m 0.005% of distance measurement ± distance resolution ± index uncertainty Meets IEC6085- Class I and CDRH Class Requirements (Eye Safe) CFR 040 Universal (Uses UC-30-XX adapters) 5 ns to µs 6 66 and 69 Distance Sampling is 0.5, 0.5, 0.5,,, 4, 8 m CMA 4500 OTDR Specification Page 3 of 5

Light Source (optional - factory installed) Multimode Type Laser LED Wavelengths Same as corresponding 850/300 nm ± 0 nm OTDR module Output -8 dbm (min.) -5 dbm (min.) Output Fiber 9/5 µm single-mode fiber 6.5 or 50 µm multimode Universal Universal (uses UC-30-XX adapters) (uses UC-30-XX adapters) Modes of Operation CW, KHz and KHz CW, KHz and KHz Stability ±0. db (8 hours) ±0. db (8 hours) <5 nm <50/<5 FWHM Safety Meets IEC6085- Class I and CDRH Class Requirements (Eye Safe) CFR 040 Power Meter (optional - factory installed) Detector Type Wavelength Range InGaAs 780-800 nm At 3º C 4500-6 quad singlemode and multi-mode only features a singlemode light source Range Calibrated Wavelengths Resolution Store Reference Mode Accuracy +0 to -45 dbm 850, 300, 30, 550, 65 nm Universal (uses LP-XX adapter caps) 0.0 db, 0.0% Watts Yes ±4% @ +5 dbm to -50 dbm ±8% @ +0 dbm to -5 dbm, -50 dbm to -55 dbm ±0.0 db, +5 dbm to -55 dbm Visual Fault Locator (optional - factory installed) Wavelength 650 nm ±0 nm Output (max) 0 dbm into 9/5 µm Transmission Mode Output Fiber CW or Hz 9/5 µm, SM fiber.5 mm Universal Safety IEC 6085- Class II, FDA ( CFR 040. 0 Class ) CMA 4500 OTDR Specification Page 4 of 5

Standard Accessories Color display with touch screen, operator's manual, support CD, Li-Ion battery (), AC charger/adapter, 0/00 MB Ethernet Port, and choice of AC line cord. Optical Accessories NOTES: Must be added as a separate line item Option-50CD-RW Option-50FLOPPY Option-507KEYUS 4500-BATT Option-5AC Option-55PRINT 4500-MANUAL 4500-HARDCASE 4500-SOFTCASE 4500-USBKEY 4500-USBFLOPPY 4500-USBCDRW 4500-EXT 4500-EXT 4500-AUTO CMA 4500/5000 internal CD/read/write module CMA 4500/5000 internal floppy drive module CMA 4500/5000 US keyboard Replacement Li-Ion battery Replacement AC charger/adapter CMA 4500/5000 portable external printer with cable and case Replacement operator s manual CMA 4500 hard transit case CMA 4500 soft transit case USB keyboard with trackball USB external floppy drive USB external CD-R/W CMA 4500 Year extended warranty CMA 4500 Year extended warranty Cigarette lighter charger/adapter AC Power Cord Options OPTION-570LINEUS US/Japan AC line cord OPTION-570LINESW Switzerland AC line cord OPTION-570LINEEU Europe AC line cord OPTION-570LINEIT Italy AC line cord OPTION-570LINEUK United Kingdom AC line cord Option for use with CMA 4500 Desktop only OPTION-570LINEAU Australia AC line cord Option-580DATA USB data transfer kit, includes software and cable for Windows 98/000/XP NetTest A/S Kirkebjerg Allé 90 DK-605 Brøndby Denmark Tel: +45 7 3 00 Fax: +45 7 3 50 E-mail: nordic@nettest.com USB Video Inspection Probe (see VIP Application datasheet for additional information) The CMA 4500/5000 video inspection probe features a 00X/400X user selectable probe that allows fiber optic connectors to be viewed, stored and analyzed (with option 546) through the CMA 4500 USB port. Option-545VIP Option-546VIPA NetTest Sales Offices China +86 0 6467 9888 Denmark +45 7 00 France +33 64 53 64 00 Germany +49 89 99 89 0-0 USB probe with basic viewing/image capture software, FC, SC, ST,.5 mm and.5 mm tips USB probe with basic viewing/image capture/advanced analysis software, hard case, FC, SC, ST,.5 mm and.5 mm tips (USB feature key) Italy +39 06 43 36 4 00 Singapore +65 60 9575 Spain +34 9 37 9 7 USA + 35 66 5000 NetTest develops and markets operational support solutions that provide unique insights into the function and performance of telecommunication networks so that owners, operators, and vendors can make informed business decisions that drive their profitability. ISO 900:000 certified. CMA 4500 OTDR Spec Sheets - A4 Rev. C 004 NetTest All Rights Reserved. Specifications subject to.