Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Similar documents
Dräger Savina 300 Classic ICU Ventilation and Respiratory Monitoring

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

D Beyond essentials DRÄGER SAVINA 300 SELECT

Dräger Savina Sub-Acute Care Ventilation

Focused on essentials DRÄGER SAVINA 300

Oxylog VE300 Emergency & Transport Ventilation

D Beyond essentials DRÄGER SAVINA 300 SELECT

Evita V300 ICU Ventilation and Respiratory Monitoring

Focused on essentials DRÄGER SAVINA 300

Dräger Evita Infinity V500 ventilator ICU Ventilation and Respiratory Monitoring

Dräger Oxylog 3000 plus Emergency & Transport Ventilation

Dräger Carina Sub-Acute Care Ventilation

Dräger Carina Sub-Acute Care Ventilation

Oxylog 2000 plus Emergency & Transport Ventilation

D Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

Oxylog 3000 plus Emergency & Transport Ventilation

Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

Dräger Babylog VN500 Neonatal Open Care

Made to meet your needs DRÄGER SAVINA 300

Evita 2 dura. High-end ventilation in your patient s best interests. Because you care

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Dräger coaxial breathing circuits Consumables and Accessories

MT Excellent performance and reliability EVITA 4 EDITION

D Designed for non-invasive ventilation DRÄGER CARINA

EvitaXL. Excellence throughout the ventilation process. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

O 2 Star - Oxygen Therapy Accessories Consumables and Accessories

Dräger NITROX 200 Diving Equipment

Dräger RZ 7000 Test Equipment

VentStar Oxylog Breathing Systems Consumables and Accessories

Dräger Aerotest Navy Test Equipment

D Rising up to the challenge OXYLOG 3000 PLUS

D Quality and Precision you can Trust in Oxygen Administration CONVENTIONAL FLOWMETER DIGITAL FLOWMETER COMPACT FLOWMETER

Primus Anaesthesia Workstations

Dräger Quaestor 7000 Test Equipment

Better to have one OXYLOG 3000

D The plus that gives you more DRÄGER FABIUS PLUS

Vamos / Vamos plus Anaesthetic Gas Monitors

MT The secret of harmonious breathing BABYLOG 8000 PLUS

Evita 2 dura. First-class ventilation in your patient s best interests. Because you care. Emergency Care OR/Anesthesia Critical Care Home Care

D Reliability goes XL

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

Dräger Secor 7000 Diving Equipment and Systems

Setting new trends in ventilation. DRÄGER EVITA INFINITY V500

Dräger PARAT 3260 Filtering Escape Device

Dräger Bodyguard 1000 Warning Device

Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

Dräger FGT 5400 Diving Equipment

D The specialist for every environment DRÄGER FABIUS TIRO

Dräger Perseus A500 Anaesthesia Workstations

D The plus that makes all the difference DRÄGER FABIUS PLUS

Resuscitaire Neonatal Open Care

INTENSIVE CARE VENTILATORS

D Your personal anesthesia assistant DRÄGER PRIMUS. Dräger. Technology for Life

Dräger Fabius GS premium Anaesthesia Workstations

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Dräger PAS Micro Short Term Breathing Apparatus

Panther 5 Acute Care Ventilator

Increase patient outcome and therapeutic benefits Dedicated NIV accessories for Carina CARINA ACCESSORIES

Dräger PAS Filter series Airline Equipment

MT Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

Dräger PA91 plus Standard and PA91 plus Marine Self Contained Breathing Apparatus

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation

Dräger Fabius plus XL Anaesthesia Workstations

OxyLine The customised pressure reducer

Dräger X-plore 9000 and PAS X-plore Airline breathing equipment

Dräger X-pect 8500 Goggles Protective Eyewear

Training Benzene Awareness. Basic Information

Technical Data and Specifications

Dräger Saver PP Compressed Air Escape

Fabius plus. The plus that makes all the difference. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Dräger ABIL-L Airline Equipment

Dräger MSI P7 Combustion Gas Analysis

Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Dräger CAPITANO 140 Mobile Compressor

Dräger OCEANUS 140 Mobile Compressor

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

Dräger Fabius Tiro Anaesthesia Workstations

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Dräger Testor 2500/3500 Test Equipment

MT Increase patient comfort and therapeutic benefits Dedicated accessories for Carina ventilator CARINA

Anesthesia Workstation

SLE5000 Infant Ventilator with HFO

fabian Therapy evolution Our 2-in-1 device

V8800 Ventilator System. Your healthcare, we care.

Dräger Compressed Air Breathing Cylinders Accessories for Breathing Apparatus

Dräger Bodyguard 7000 Warning Device

Technology Insights for protective ventilation and spontaneous breathing in the OR

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command

Oxylog Better to have one. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

D Accessories that actively cooperate DRÄGER INFINITY ID-ACCESSORIES

DATA SHEET. VENTILATION SERVO-s

Fabius MRI. From specialists for specialists. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Dräger PAS AirPack 1 Compressed Air Breathing Apparatus

Selecting the Ventilator and the Mode. Chapter 6

Dräger X-plore 6300 Full-Face Mask

Airox Supportair Ventilator

Transcription:

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring The Dräger Savina 300 Select (in this configuration) combines the independence and power of a turbine-driven ventilation system with sophisticated ventilation modes It's broad variety of features and accessories supports a patient range from babies* to adults The large colour touch screen and intuitive operating system that concentrates on established high class features make configuration and operation very simple D-12295-2016 * starting from 5 kg bodyweight

02 Dräger Savina 300 Select Benefits Ease-of-use Intuitive for simple operation and quick configuration Dräger-wide standardised user interface provides confidence in use and reduces training time Quick operational readiness with an automatic device check Safe and fast initial start of ventilation thanks to pre-set start configuration based on patient height or patient category Intelligent alarm handling for a quick response to patient alarm situations Smooth and sealed surfaces for easy cleaning and disinfection High ventilation performance Sophisticated ventilation modes for critically ill patients (eg PC-APRV, VC-MMV, AutoFlow ) Enhanced trigger detection and precise ventilation settings allow the ventilation of babies starting from 5 kg bodyweight Automatic Tube Compensation ATC reduces the work of breathing for intubated patients with spontaneous breathing1 Stress-free spontaneous breathing with excellent trigger response time thanks to the turbine Free breathing with AutoFlow in volume constant ventilation at a minimum pressure level Non-invasive ventilation (NIV) available in all modes with a very quick response times to patient efforts No device change needed in case of altered ventilation therapy: O 2 -therapy allows oxygen application with constant flow Extended graphic capabilities with loops, trends and logbook Independent from gas and power supply Built-in-turbine with rapid response time and continuous high flow delivery of up to 250 L/min Five hours of independent ventilation due to built-in and external batteries Transport Supply Unit (TSU) can be quickly attached for ergonomic handling of gas cylinders Bed coupling for quick connection between ventilator and patient bed Low Pressure Oxygen (LPO) inlet for ventilation without central gas supply 1 Respiratory comfort of automatic tube compensation and inspiratory pressure support in conscious humans Guttmann, J et al, Intensive Care Medicine 1997, Vol 23, No11, 1119-1124

Dräger Savina 300 Select 03 Related Products Dräger Evita Infinity V500 ventilator Combine fully-featured, high-performance ventilation with Infinity Acute Care System integration to meet the challenges of today s health care environment D-36746-2015 MT-6073-2008 Dräger Carina Designed for non-invasive ventilation: With its unique SyncPlus technology and an extended NIV function, the user-friendly Dräger Carina offers reliable and easy ventilation and thanks to its compact design, this also applies when transporting patients Evita V300 The Evita V300 is a scalable and versatile device which offers high ventilation quality To meet and master the changing conditions and challenges of your everyday hospital work you need flexible equipment with versatile opportunities D-43497-2012

04 Dräger Savina 300 Select Technical Data Ventilation modes Volume-controlled ventilation modes VC-CMV / VC-AC VC-SIMV VC-MMV Pressure-controlled ventilation modes PC-APRV PC-BIPAP 1 / PC-SIMV+ PC-AC Support of spontaneous breathing SPN-CPAP Enhancements Patient type Respiratory rate Inspiration time Tidal volume Inspiratory pressure AutoFlow Automatic adaption of the inspiratory flow in volume orientated ventilation modes NIV Non Invasive Ventilation with optimised alarm systems and automatic leakage compensation Peadiatric Plus allowing the ventilation of babies starting from 5 kg bodyweight Capnography Mainstream CO 2 measurement MonitoringPlus Loops, Trends, user Logbook LPO Low Pressure Oxygen Independent oxygen supply, eg with an O 2 concentrator Nurse call Connection for transmitting alarm signals to a central, alarm system Automatic tube compensation ATC Automatic tube compensation regulates the airway pressure to the tracheal level O 2 -therapy continuous flow is applied via an oxygen mask, a hood or nasal cannula for patients with independent breathing Adult, paediatric patients, and babies starting from 5 kg bodyweight 2/min to 80/min 02 to 10 s 005 to 20 L, BTPS 2 with PaediatricPlus 002 to 20 L, BTPS 1 to 99 mbar (or hpa or cmh 2 O) (1 mbar = 100 Pa) PEEP/interm PEEP 0 to 50 mbar (or hpa or cmh 2 O) Pressure support/δpsupp Flow acceleration O 2 -concentration 21 to 100 Vol % Trigger sensitivity (Flow trigger) Inspiratory termination criterion PC-APRV (otional) O 2 -therapy Automatic tube compensation ATC 0 to 50 mbar (or hpa or cmh 2 O) (relative to PEEP) 5 to 200 mbar/s (or hpa/s or cmh 2 O/s) 1 to 15 L/min 5 to 75 % PIF (peak inspiratory flow) Inspiratory time T high 02 to 220 s Expiratory time T low 01 to 220 s Inspiratory pressure P high 1 to 95 mbar (or hpa or cmh 2 O) Expiratory pressure P low 0 to 50 mbar (or hpa or cmh 2 O) Constant flow Flow (BTPS) 2 to 100 L/min in increments of 1 L/min O 2 concentration FiO 2 21 to 100 Vol% in increments of 1 Vol% Tube type: Endotracheal tube ET or tracheostomy tube Trach Inner diameter of the tube 35 to 120 mm in increments of 05 mm

Dräger Savina 300 Select 05 Technical Data Displayed measured values Airway pressure measurements Minute volume (MV) Tidal volume Total respiratory rate Inspiratory O 2 -concentration End-tidal CO 2 concentration EtCO 2 Breathing gas temperature Curve displays Max airway pressure, plateau pressure, mean airway pressure, PEEP 0 to 99 mbar (or hpa or cmh 2 O) Total MV, spontaneous MV 0 to 99 L/min, BTPS Inspiratory VT, expiratory VTe, VT spon 0 to 3999 ml, BTPS Total and spontaneous respiratory rate, 0 to 150/min 21 to 100 % Vol Ventilation ratio (I:E) 1:150 to 150:1 0 to 100 mmhg (or 0 to 132 Vol% or 0 to 133 kpa) 18 to 48 C (644 to 1184 F) Paw(t), Flow(t), Tidal volume (t), CO 2 (t) Compliance C 05 to 200 ml/mbar (or ml/hpa or ml/cmh 2 O) Resistance R Leakage minute volume MVleak 0 to 100 % Rapid shallow breathing RSB 3 to 300 mbar/l/s (or hpa/l/s or cmh 2 O/L/s) 0 to 9999 (1/min/L) Special Manoeuvres Intrinsic PEEP PEEPi 0 to 100 mbar (or hpa or cmh 2 O) Exp Hold Loops (MonitoringPlus) Pressure / Volume Volume / Flow Flow / Pressure Volume / CO 2 Ptrach Volume Flow Ptrach Alarms Airway pressures Expiratory minute volume Tidal volume Apnoea-alarm time Spontaneous breathing frequency Inspiratory O 2 -concentration Inspiratory breathing gas temperature Inspiratory breathing gas temperature EtCO 2 15 to 60 sec high high high Performance data Maximum (continuous) inspiratory flow Valve response time T0 90 Control principle 250 L/min 5 ms time-cycled, volume-controlled, pressure limited Safety valve opening pressure 120 mbar (or hpa or cmh 2 O) Emergency valve Automatic gas switch-over function if O 2 supply fails Output for pneumatic medication nebuliser Leak compensation automatically enables spontaneous breathing with filtered ambient air if air and O 2 supply should fail synchronised with inspiration synchronised patient-ventilator synchrony adjusts the flow trigger and the inspiratory termination criteria for leaks tube application: up to 10 L/min NIV VC-modes: up to 25 L/min NIV PC-modes: unlimited

06 Dräger Savina 300 Select Technical Data Operating data Mains power connection Current consumption 100 V to 240 V, 50/60 Hz max 13 A at 240 V, max 34 A at 100 V Battery internal typically 45 min (optional extension up to 5 h) Turbine exchange interval Digital machine outputs Digital output and input via an RS 232 C interface Dräger MEDIBUS and MEDIBUSX 8 years, with no limit in operating hours during this interval Gas supply Air O 2 gas supply Turbine technology (with a manufacturer guarantee of 8 years for the turbine 4 ) 3 bar (435 psi) 10 % up to 6 bar (87 psi) Dimensions and weights Dimensions W x H x D (without trolley) Weight (basic device) Diagonal screen size 1 BIPAP Trademark used under licence Not all products, features, or services are for sale in all countries Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released Go to wwwdraegercom/trademarks to find the current status 460 x 383 x 364 ±2 mm (1811 x 1508 x 1433 ±008 inch) approx 26 kg (573 lbs) without trolley 12" TFT colour touch screen 2 BTPS Body Temperature Pressure Saturated Measured values relating to the conditions of the patient lung (986 F), steam-saturated gas, ambient pressure 3 1 mbar = 100 Pa 4 Limited Manufacturer Guarantee subject to conditions specified in the Instructions for Use Applies only to devices purchased after 1/1/2015 Some functionalities are available as an option 91 03 255 1802-6 HQ PP Subject to modifications 2018 CORPORATE HEADQUARTERS Moislinger Allee 53 55 23558 Lübeck, Germany wwwdraegercom Manufacturer: Moislinger Allee 53-55 23542 Lübeck, Germany REGION DACH Moislinger Allee 53 55 23558 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom REGION EUROPE Moislinger Allee 53 55 23558 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom REGION MIDDLE EAST, AFRICA Branch Office PO Box 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fax +971 4 4294 699 contactuae@draegercom REGION ASIA PACIFIC Draeger Singapore Pte Ltd 25 International Business Park #04-20/21 German Centre Singapore 609916 Tel +65 6308 9400 Fax +65 6308 9401 asiapacific@draegercom REGION NORTH AMERICA Draeger, Inc 3135 Quarry Road Telford, PA 18969-1042, USA Tel +1 800 4DRAGER (+1 800 437 2437) Fax +1 215 723 5935 infousa@draegercom REGION CENTRAL AND SOUTH AMERICA Dräger Panama S de RL 59 East Street, Nuevo Paitilla House 30, San Francisco Town Panama City, Panama Tel +507 377 9100 Fax +507 377 9130 servicioalcliente@draegercom Locate your Regional Sales Representative at: wwwdraegercom/contact