Watts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available

Similar documents
FEATURES AND BENEFITS. Meets UL/EN/IEC , 4Th ed. For EMC*

Series AM3T-VZ 3 Watt DC-DC Converter

JUMO dtrans p30 Pressure Transmitter

DCS Series 1 kw, 1.2 kw, & 3 kw

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

MANUAL KPS Pressure Control Valve

Picture. Minimum cable bending radius 100 mm [4"] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables)

ATM.ECO - Analog Pressure Transmitter

Test Report #: Date: June 21, 2005

Verdi G-Series Family

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

TeSys protection components

ATM.1ST/Ex - High Precision Transmitter

PIKO IQ 4.2, Plenticore plus 4.2 Rating: 10,0kW 8,5kW 7,0kW 5,5kW 4,2kW Rated voltage: PIKO IQ 8.5, Plenticore plus 8.5

Verdi G-Series. High-Power Pumps for Ti:Sapphire Lasers and Amplifiers FEATURES

Gas density monitor With integrated transmitter Model GDM-100-TI

EPRB-2 Pressure Transducer

Models: BRP391 series; BRP392 series; BRP394 series;

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

VLT 2000 Series. How to size your VLT

High-performance submersible pressure transmitter For level measurement Model LH-20

ATM.ECO/IS - Analog Transmitter with Temperature compensation

Pressure switch Type BCP

Type S-10, S-11 General Purpose Pressure Transmitters

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-10

Raising the bar. Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for maximizing energy savings

High-performance submersible pressure transmitter For level measurement Model LH-10

Tightness controls TC 1 3 and TC 4

MB610 Industrial Pressure Transmitter

GasSense NDIR User Manual

Technical Data. Dimensions

Programmable pressure and temperature transmitters PTM/RS485

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Parametrable / Programmable Pressure Transmitter

Programmable pressure and temperature transmitters PTM/RS485

Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Speed Controller ADR 40 Condensing pressure controller SPEED REGULATORS FOR ASYNCHRONOUS SINGLE PHASE MOTORS SERIES ADR 40 ADR 40 ADR 40 PP

Genesis MX SLM-Series

Model PDT Dewpoint Transmitter

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

RPS900W Redundant Power Supply. Installation Guide.

[Instruments for vacuum measurement, checking and adjustment] 3

Pressure transmitters EMP 2

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

Proportional pressure regulators VPPE

PRODUCT SPECIFICATION

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

CONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17

TH-1800-T TRX-700-CNG Converter

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

High-performance submersible pressure transmitter For level measurement Model LH-20

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Zelio Relays RSL Slim Interface Plug-In Relays

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Miniature controls. Contactors. Overload relays. Starters. Control relays

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Continuous Gas Analyzers, extractive

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

2/2-Way Proportional Valve (motor-driven)

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

SPECIFICATION. 3in1 LTE MIMO + GNSS Antenna

Inverse Prop. Pressure-Relief Cart., Size 2 4

Technical Data. Dimensions

CONTENT. Report No.: GZ R6. Page 2 of 17

OPERATION & INSTALLATION INSTRUCTIONS

ATM/Ex - Analog Pressure Transmitter

PROGRAMMER OPERATIONS MANUAL

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

ATM - Analog Pressure Transmitter

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

VSD03M DIRECTIONAL CONTROL VALVES

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

P900. P900, Datenblatt Seite 1 DESCRIPTION

RELAY PRODUCT GUIDE CONTENTS

User manual. PG89 Rev 01 Editi Pressotherapy model. LymphoPress 4

OPTIBAR P 1010 C Technical Datasheet

Pressure Automated Calibration Equipment

FMAC Sine FMAC Sine DCL

Technical Data. Dimensions

WAGO-I/O-SYSTEM 750 XTR Taking it to the extreme The Standard for 750 XTR

Technical Data. Dimensions

DPS-400 SERIES DPH-100 SERIES

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

P499 Heavy Duty Pressure Transducer

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

Mass Flow Meter (MFM) for gases

Differential pressure controls, Type MP 54, 55 and 55A

Control and Automation

Transcription:

-0 Watts AEH Series s from. V to 8 V xppower.com Non-standard s Available Universal Input Single & Multiple Versions 0 C to +60 C Operating Temperature Efficiency up to 80% Non-standard Connectors Available Specification Input Input Input Frequency Input Inrush Earth Leakage Power Factor 90-6 VAC 7-6 Hz 0./0.6 A for AEH, at /0 VAC./0.7 A for AEH, at /0 VAC.9/. A for AEH80, at /0 VAC./.7 A for AEH0, at /0 VAC AEH, & 80: 0 A max at 0 VAC AEH0: 60 A max at 0 VAC cold start <0. ma max at VAC/60 Hz <0.7 ma max at 0 VAC/0 Hz EN6000-- class A See tables, non-standard voltages available - contact sales Initial Set Accuracy % Start Up Delay s max Hold Up Time 6 ms min (>0 ms AEH0) Line Regulation See tables Load Regulation See tables Transient Response % max deviation, recovery to within % in ms for a 0% load change Ripple & Noise % pk-pk for outputs. V % pk-pk for all other outputs 0 MHz bandwidth Overvoltage Protection -% Vnom, auto reset Overload Protection only 0-0% of nominal (AEH protected to short circuit) Temperature ±0.0%/ C max Coefficient General Efficiency Up to 80% Isolation 000 V to 00 V to Ground 00 VAC to Ground Switching Frequency 6-80 khz for AEH 67-8 khz for AEH 8 khz typical for AEH80-76 khz for AEH0 MTBF 00 khrs per MIL-HDBK-7F at C GB Environmental Operating Temperature 0 C to +60 C, derate linearly from 00% load at +0 C to 0% load at +60 C Operating Humidity -9% RH, non-condensing Storage Temperature -0 C to +8 C Vibration g on axes EMC & Safety Emissions Harmonic s Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions Safety Approvals EN0 level B, conducted and radiated EN6000--, Class A EN6000-- EN6000--, level Perf Criteria A EN6000--, level Perf Criteria A EN6000--, level Perf Criteria A EN6000--, level Perf Criteria A EN6000--6, level Perf Criteria A EN6000-- 0% 0 ms, 60% 00 ms, 00% 000 ms Perf Criteria A, B, B EN6090-, UL6090-, CSA C. No. 90 per cul, CE Mark

AEH Total Model Power Nominal () Minimum Maximum Regulation () 8. W. V 0.0 A.0 A 7% AEHUS0.00 W.0 V 0.0 A.0 A % AEHUS0.00 W 7.0 V 0.0 A.70 A % AEHUS07.00 W 0.0 V 0.0 A.0 A % AEHUS0.00 W.0 V 0.0 A. A % AEHUS.00 W.0 V 0.0 A.00 A % AEHUS.00 W 8.0 V 0.0 A 0.8 A % AEHUS8.00 W.0 V 0.0 A 0.6 A % AEHUS.00 W 0.0 V 0.0 A 0.0 A % AEHUS0.00 W 6.0 V 0.0 A 0. A % AEHUS6.00 W 8.0 V 0.0 A 0. A % AEHUS8. Factory-set non-standard outputs available.. Total regulation includes initial set accuracy, line and load regulation. IEC 0 Inlet. (8.0). (6.0).8 (9.0). connector is.mm outer diameter barrel. Inner diameter is.mm with centre positive (+) and outer shell negative (-).. cable length is 7.0 (80).. Optional output connectors available, contact sales office. 6. Weight 0.6 lb (6 g) approx. 7. For UK mains lead order part: UK-MAINS-IEC.

AEH (,) (,) (,) Model Max Nom. Min Max Nom. Min Max Nom. Min Max 0 W. V 0.0 A 8.0 A AEHUS0 6 W. V 0.0 A 8.0 A AEHUS0 0 W.0 V 0.0 A 8.0 A AEHUS0 W 7.0 V 0.0 A 6.0 A AEHUS07 W 0.0 V 0.0 A. A AEHUS0 W.0 V 0.0 A.7 A AEHUS W.0 V 0.0 A.9 A AEHUS W 8.0 V 0.0 A. A AEHUS8 8 W.0 V 0.0 A.0 A AEHUS 0 W 0.0 V 0.0 A.7 A AEHUS0 0 W 6.0 V 0.0 A. A AEHUS6 0 W 8.0 V 0.0 A.0 A AEHUS8 W +.0 V 0. A.0 A -.0 V 0. A.0 A AEHUM W +.0 V 0. A.0 A -.0 V 0. A.0 A AEHUM W +.0 V 0. A.0 A +.0 V 0. A.0 A AEHUM W +.0 V 0. A.0 A +.0 V 0. A. A AEHUM6 W +.0 V 0. A.0 A +.0 V 0. A.0 A AEHUM W +.0 V 0. A.0 A -.0 V 0. A.0 A AEHUM7 7 W +. V 0. A.0 A +.0 V 0. A.0 A AEHUM8 0 W +. V 0. A.0 A +.0 V 0. A.0 A AEHUM9 W +.0 V 0. A.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEHUM W +.0 V 0. A.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEHUM W +.0 V 0. A.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEHUM 0 W +. V 0. A. A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEHUM W +. V 0. A.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEHUM W +.0 V 0. A.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEHUM8 W +.0 V 0. A.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0. A AEHUM9. Factory-set non-standard outputs available.. Total regulation includes initial set accuracy, line and load regulation and is typically % for output and % for auxiliaries. DC OUTPUT Pin SINGLE DUAL TRIPLE Shell GND GND GND Common Common Common Common Common Common Common Common.69 (.0).7 (6.0) ±.0 IEC 0-C Inlet.99 (76.0) DC Pin Plug. cable length is 8 (0 mm) approx.. Optional output connectors available, contact sales.. Weight 0.9-. lb (00-00 g) approx. 6. For UK mains lead order part: UK-MAINS-IEC. 7. For mating DIN connector, use standard pin 80 socket.

. Factory-set non-standard outputs available.. Total regulation includes initial set accuracy, line and load regulation and is typically % for output and % for auxiliaries. AEH80 (,) (,) (,) Model Max Nom. Min Max Nom. Min Max Nom. Min Max 0 W. V 0.0 A. A AEH80US0 6 W.0 V 0.0 A.0 A AEH80US0 70 W 7.0 V 0.0 A 9.9 A AEH80US07 7 W 0.0 V 0.0 A 7. A AEH80US0 80 W.0 V 0.0 A 6.6 A AEH80US 80 W.0 V 0.0 A. A AEH80US 80 W 8.0 V 0.0 A. A AEH80US8 80 W.0 V 0.0 A. A AEH80US 80 W 0.0 V 0.0 A.6 A AEH80US0 80 W 6.0 V 0.0 A. A AEH80US6 80 W 8.0 V 0.0 A.6 A AEH80US8 60 W +.0 V 0.7 A 7.0 A +.0 V 0. A.0 A AEH80UM 60 W +.0 V. A 7.0 A +.0 V 0.6 A.0 A AEH80UM6 60 W +.0 V. A 7.0 A +.0 V 0. A.0 A AEH80UM 60 W +.0 V. A 7.0 A -.0 V 0. A.0 A AEH80UM9 8 W +. V. A 7.0 A +.0 V 0.6 A.0 A AEH80UM8 6 W +. V 0.7 A 7.0 A +.0 V 0. A.0 A AEH80UM7 6 W +.0 V 0.6 A 6.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEH80UM 6 W +.0 V 0.6 A 6.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEH80UM 6 W +.0 V 0.6 A 6.0 A +.0 V 0. A. A -.0 V 0.0 A 0.8 A AEH80UM 6 W +. V 0.7 A 7.0 A +.0 V 0.6 A.0 A -.0 V 0.0 A 0.8 A AEH80UM 6 W +. V. A 7.0 A +.0 V 0.6 A.0 A -.0 V 0. A 0.8 A AEH80UM7 6 W +.0 V 0.7 A 7.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEH80UM8 6 W +.0 V 0.6 A 6.0 A +.0 V 0. A.0 A -.0 V 0.0 A 0.8 A AEH80UM9 IEC 0-C Inlet.7 (.) 6.6 (67.9) ±.0.09 (78.) DC 8 Pin Plug 6 8 7. cable length is 8 (0mm) approx.. Optional output connectors available, contact sales.. Weight 0.9-. lb (00-00 g) approx. 6. For UK mains lead order part: UK-MAINS-IEC, DC Pin Plug DC OUTPUT Pin SINGLES 0, 0 V 07-8 V DUAL TRIPLE Shell GND GND GND GND Common Common Common Common Common Common Common Common 6 Common Common Common 7 8 Common

. Factory-set non-standard outputs available.. Total regulation includes initial set accuracy, line and load regulation. AEH0 (,) (,) Model Total Total Max Nom. Min Max Regulation Nom. Min Max Regulation 90 W. V 0.0 A 7. A 7% AEH0PSV W.0 V 0.0 A.0 A 7% AEH0PS0 0 W 7.0 V 0.0 A 8. A 7% AEH0PS07 0 W 9.0 V 0.0 A. A % AEH0PS09 0 W.0 V 0.0 A 0.8 A % AEH0PS 0 W.0 V 0.0 A 8.6 A % AEH0PS 0 W 8.0 V 0.0 A 7. A % AEH0PS8 0 W.0 V 0.0 A. A % AEH0PS 0 W 8.0 V 0.0 A.6 A % AEH0PS8 0 W 6.0 V 0.0 A.6 A % AEH0PS6 0 W 8.0 V 0.0 A.7 A % AEH0PS8 0 W.0 V 0.0 A. A % AEH0PS 90 W +. V.0 A 0.0 A 0% +.0 V 0. A.0 A % AEH0PD0 0 W +.0 V.0 A 0.0 A 7% +.0 V 0. A.0 A % AEH0PD0 0 W +.0 V.0 A 0.0 A 7% +.0 V 0. A.0 A % AEH0PD0 0 W +.0 V.0 A 0.0 A 7% +.0 V 0. A.0 A % AEH0PD0 IEC 0-C Inlet 6 8 7 Pin SINGLE DUAL Shell GND GND Common Common Common Common 6 Common Common 7 8 Common 0.8 (.). (9.0) 7.7 (96.0) ±.0.6 (88.0). cable length is 8 (0mm) approx.. Optional output connectors available, contact sales.. Weight.9 lb (860 g) approx. 6. For UK mains lead order part: UK-MAINS-IEC, 6-Jun-