Some tentative AMS improvements (and a note on IE calibrations)

Similar documents
BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Choosing a Quadrupole Gas Analyzer Application Note #9

PHOENIX L300i Best-in-class Helium Leak Detectors

Go/no-go test for the acceptance of components for unbaked vacuum sectors

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

A novel class of Non Evaporable Getter (NEG) alloys with lower hydrogen equilibrium pressure and reduced outgassing properties

Vacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007

Low-Power Atmospheric Gas Sampling System Based on ART MS Sensor and NEG-Ion Pump

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

Saturday Sept 16, 2006

Constant Pressure Inlet (CCN) Operator Manual

Determination of the Vacuum System for R2R by using a New Pumping Simulation Program

Mass Spec will not Autotune

Major Design Features

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

HumiSys HF High Flow RH Generator

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

Gun Vacuum Performance Measurements February 2003

1)! DO NOT PROCEED BEYOND THIS MARK

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

Underwater cryotrap - membrane inlet system (CT-MIS) for improved in situ analysis of gases by mass spectrometry.

Residual Gas Analysis Systems for Industry

Detecting Hydrogen in Helium Streams. Samuel Goodman. Pittsford Mendon High School. Rochester, New York. Advisor: Dr.

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Chapter 8: Cryo-sorption pumps

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

Practical approach and problems in in-situ RGA calibration

The Principles of Vacuum Technology

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Chapter 6 Leak detection

Measuring mass flows in hermetically sealed MEMs & MOEMs to ensure device reliability

Generating Calibration Gas Standards

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Leak Checking Large Vacuum Chambers

Introductory Lab: Vacuum Methods

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

LESER Deutschland Standard Functional Tightness Test (Cryo) Content

ISO/TC 112/WG 2 N 49. ISO TS QMS WD v6. Date of document Expected action Comment Due Date Background

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

(2 pts) Draw the line of best fit through the data and estimate the concentration of Fe in your sample solution.

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

2 Switching off ECRIS 3. 4 Acquire Beam Spectrum 4. 6 Vent Instrument Chamber 5. 7 Pump down Chamber 5. 8 Baking out Chamber 5.

The Discussion of this exercise covers the following points:

FPG8601 Force Balanced Piston Gauge

Technical Data Sheet MF010-O-LC

ACV-10 Automatic Control Valve

Approved by Principal Investigator Date: Approved by Super User: Date:

During today's webinar we're going to look at the following topics:

The Helium Leak Detector

Total Pressure Measurement Using Residual Gas Analyzers

Active Control of Vapor Pressurization (VaPak) Systems

Succeeding with Production Air Leak Testing Methods. Paul Chamberlain President, CEO

E SC 412 Nanotechnology: Materials, Infrastructure, and Safety Wook Jun Nam The Pennsylvania State University

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

Quadruple mass spectrometers (transducer type)

Matching Vacuum Pump to Process

Operation of the Perkin Elmer TGA-GC/MS

The latest automotive systems require innovative leak test methods and fixturing.

cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated

Level MEASUREMENT 1/2016

Resist round robin ELETTRA

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

ACCELERATOR VACUUM PROBLEMS: IN-LINE OIL TRAPPING BETWEgN THE STANFORD LINEAR ACCELERATOR AND THE BEAM SWITCHYARD

Additel 761 Automated Pressure Calibrators

Hiden QIC Series Gas Analysers Real-time gas analysis systems


Results of mathematical modelling the kinetics of gaseous exchange through small channels in micro dischargers

Improving the Measurement Accuracy of Water Partial Pressure Using the Major Constituent Analyzer

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

628 Differential Pressure Decay Leak Tester

In-Water Mass Spectrometry for Characterization of Light Hydrocarbon Seeps and Leaks

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

OOC RGA. Ion Pump 400 l/s. 8" ports with baked viton o-ring seals. Welsh rotary roughing pump 650 l/s manual isolation valve.

The Gas Attenuator of FLASH

Dissolved Oxygen Guide

The Broadest Gauging Line in the Industry

The New PHD 4 Portable Helium Detector

AGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

at NIST: ultra-low outgassing rates

On-Stream Tightness Testing of Vacuum Process Installations

Login to ilab Kiosk. Revised 05/22/2018. Load your sample:

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Pressure Measurement

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

Vacuum Simulations of the KATRIN Experiment

Advantages of Carrier Gas Leak Detection using Novel Helium or Hydrogen Leak Detectors with Specific Sensor Types

Granville-Phillips Series 370 Stabil-Ion Vacuum Gauge Controller

The instrument should have a mass range from 2 to 2000 m/z or better Interface

INSTRUMENT INSTRUMENT YL INSTRUMENT

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

Overview. Front Panel: Keypad and Display

Microscopy Cryogenic WORKSTATION. Performance by Design

LFE OEM TCD - Thermal Conductivity Detector

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Transcription:

Some tentative AMS improvements (and a note on IE calibrations) Pedro Campuzano Jost University of Colorado, Boulder AMS Users Meeting Outline Integrating a Cryopump in an aircraft AMS: First notes on a successful deployment Vaporization of ammonium nitrate in a PCI inlet: How to tell your test aerosol is not working An internal fluorine standard for the HR-TOF-AMS: Worth the trouble? Some additional resources: AMS venting scheme, RF guide tuning 2 1

The problem: Subpar performance of (A)MS in the first hours of pump down Aircraft deployments involve switching the instrument off overnight and starting measurements ~2-3 h after initial pumpdown This is due to a significant amount of water and organics will come off the walls when pumping ceases, even in a perfectly leak-tight system. There are structural ways to reduce this significantly, but the resulting vacuum manifold would not be aircraft friendly. It takes typically 1-2 days of pumping to reestablish an equilibrium in the ionization chamber between gas background and walls. In the meantime, the elevated gas background ruins sensitivity since: 3 ~ Cubison et al, ARCTAS-A, RF11 Some old-school tech to deal with it 4 The pumping efficiency of HV pumps such as turbos decrease with molecular mass On the other hand, a cold surface (especially if its very close to the zone of interest (ie the ionizer chamber in our case) will pump high molecular mass compounds very efficiently 2

J Jayne Ricor MicroStar TM Cryopump 5 th AMS Users meeting fast pump out / background reduction in ARI Aerosol Mass Spectrometer ionizer chamber http://www.ricor.com 1000 Ls -1 pumping speed for water 17 kg (38 lbs) 400 Watts start-up at 50 VDC (~200W normal load) Cryoshiled surrounds ionizer Mounted between P5 (V301) and chamber 5 How to integrate it into an aircraft instrument Take advantage of new, air cooled pump model, ie no water requirements, half the weight (22 lbs) (and less power) Since there is no room either below P5 or in front of it, interface the AMS chamber from the back/bottom side (ie where the little window normally sits) This places the (still heavy) pump at the lowest point in the assembly, while orienting it in line with the airplanes g-forces 6 However, a combination of a custom compression flange and rails below the pump can neutralize those g-forces effectively. 3

Some more pictures 7 First Test: AMS UMR Background, cooling down 10 6 400 K 298 K 200 K Organics NO3 SO4 NH4 Chl Water 10 5 signal, Hz 130 K 90 K 120 K 10 4 10 3 8 10:05 PM 3/26/2012 10:30 PM 10:55 PM 11:20 PM 11:45 PM Date and Time 4

Was it worth the trouble? ARCTAS, as above, no cryo DC3 RF18, with cryopump @ 90 K After 4 h of pumping, there is no change in background concentrations in the AMS with cryopump. This is very close to the (for aircraft campaigns) customary 3 h pumpdown. Hence, a cryopump enhanced AMS can guarantee consistent detection limits for almost the full flight. 9 But does it actually improve the ultimate detection limits of the instrument? An attempt at apples to apples comparison Cryopump @ 250 K Cryopump @ 90 K UMR HR 10 5

In summary Integrating a cryopump is a worthwhile investment in any application where the AMS is needed <1 d after pumpdown (especially when measuring low concentrations, as in aircraft studies). Adds minimal complexity during operation. Cryopump needs to be switched on after turbos are up and defrosted back to 300 K before switching off the turbos (or regenerated periodically if run continuously in a lab). For non-time sensitive applications, it adds the benefit of higher particulate water sensitivity. Significant improvements are also seen for all other species, except organics. 11 Vaporization of ammonium nitrate in a PCI inlet MS Zombies never die, they just retreat 12 6

In the good old days, back when the User Meetings were much worse Middlebrook et al, first PCI inlet for the AMS 13 After a long investigation, wrong mounting of the critical orifice (ie drill direction not in flow direction) was blamed for this. A.D. 2012: Newish PCI with new plumbing 14 No matter what we did, we always got 2 modes in ptof And since this was an aircraft study, a smaller slit chopper wheel was not an option 7

Strange Mass Ratio! (expected 5-6, in reality 2) Plotting the IEs from analyzing each mode separately should roughly give you the mass ratio of both modes. If they were doubly charged particles, that means: ~ 2 2 Less work to analyze, but equally telling are the PToF size of those modes and the ion signal size 15 In cases such as this, trusting your own AMS size calibration is the way to go 16 You did size calibrate your AMS at the beginning of your last field study, didn t you? 8

Using an internal PFC standard for the HR-ToF-AMS Some promising adventures. 17 Why use an internal standard? Potential benefits of an internal standard: m/z calibration Determination of peak shape and peak width dependence (resolution) Monitor performance of thresholding algorithm and MCP sensitivity Absolute mass sensitivity standard All of these are functions are performed in the AMS by the residual/ differential air ions. This can lead to issues when: Accurate measurements over m/z 150 are needed There are external fluctuations in the AB No good ions are available for the task at hand (ie 40/28 for MCP performance) AB is not available (ie ACSM, hence the internal naphtalene standard) 18 9

Perflourocarbons (PFCs) as MS standards Typically, for general MS applications, perfluorocarbons are preferred as internal standards since: Few isotopes to deal with (except for 13 C) Strong negative mass defect ensures little to no interferences in an instrument with decent resolution (dm/m>1000) when analyzing other regular organic ions (but can be a problematic with some sulfates and other halogens) High m/z Cals, de Carlo et al 2006, Shilling et al 2009 External perflurotetracosane (C 24 F 50, MW 1238), introduced via aerosol lens. Not a true internal standard Hard to integrate into a field setup 19 A new candidate: FC-5311 Chemical Formula C 14 F 24, MW 624 Liquid, 0.15 mbar vp @ RT Not a random mixture (like similarly inexpensive fomblin or pfk), hence reproducible signal ratios Unlike long chain alkylfluorides, very little intensity below m/z 131 (except for CF 3, m/z 69) 20 10

A few technical notes Similar setup as the ACSM napthalene standard, ie liquid reservoir behind a critical orifice, except as an external addition, so that Calibrant/orifice can easily be replaced Reservoir can be thermostated (not field tested yet) Due to long inlet line, takes about 1d to equilibrate 21 A small orifice (1 um) is certainly advisable to get rid of evil cluster ions in your baseline. Some noticeable improvements m/z cal Air m/z cal Fluorine Ions 1.2 Pika Peak width: significant improvement for m/z between 50 and 200 Fluorine Ratio [a.u.] 1.0 0.8 0.6 0.4 0.2 f40 (virtual) f131 f243 f293 22 0.0 7/29/2011 8/8/2011 8/18/2011 8/28/2011 Time [MDT] Advanced ion threshold and transmission diagnostics! 11

What needs work Even the relatively mild temperature swings in the air conditioned BEACHON trailer had a significant impact on fluorine ion signal in the AMS. Running the calibrant reservoir at 37 C will improve this, we hope enough that inferring sensitivity becomes feasible. At any concentration level that is workable for the AMS, there will be a significant interaction between the EI filament output and the calibrant vapor pressure. Both temperature control of the calibrant AND emission control of the filament output will help here 23 HOWEVER: It remains to be seen if long term operation of the calibrant with a healthy filament is possible And two announcements A diagram and shopping list to replicate my safe AMS venting scheme (as discussed during the last AMS Clinic) is available under: http://cires.colorado.edu/jimenezgroup/tofamsresources/hardware/venting_schematic.pdf If you happen to use an RF ion guide instead of an lens stack for your particular flavor of HR-ToF, be aware that finding an optimal tuning is very different from a normal AMS (just peaking your AB WILL NOT WORK). I have some howto s for these, if you are interested please email me. 24 12