24th DOE/NRC NUCLEAR AIR CLEANING AND TREATMENT CONFERENCE SIMULATION TEST OF AEROSOL GENERATION FROM VESSELS

Similar documents
EDUCTOR. principle of operation

MS.RAJA ELGADY/PRESSURE PAPER 3

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER

Old-Exam.Questions-Ch-14 T072 T071

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Purpose of application of the program VisiMix Laminar finding a way to increase volume of the batch without overloading the motor.

CRYSTALLIZATION FOULING IN PACKED COLUMNS

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

Tutorial. BOSfluids. Relief valve

Effect of Nozzle Twisted Lance on Jet Behavior and Spitting Rate in Top Blown Process

Adsorption Unit Operating Procedures: CO2 Adsorption on to Activated Carbon

DRINKING WATER - LAB EXPERIMENTS LAB EXPERIMENTS. Nanofiltration

Development of High-speed Gas Dissolution Device

At the end of this lesson, you will be able to do the following:

PHYS 101 Previous Exam Problems

SENSITIVITY ANALYSIS OF THE FIRST CIRCUIT OF COLD CHANNEL PIPELINE RUPTURE SIZE FOR WWER 440/270 REACTOR

Runs Solution Temp. Pressure zero reset

AP Physics B Ch 10 Fluids. MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

OIL AND GAS INDUSTRY

These variables can be accessed by holding the UP button for 5 seconds.

CFD SIMULATIONS OF GAS DISPERSION IN VENTILATED ROOMS

A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers

Fluid Flow. Link. Flow» P 1 P 2 Figure 1. Flow Model

EXAM # 2. First Name Last Name CIRCLE YOUR LECTURE BELOW: INSTRUCTIONS

Körting Liquid Jet Vacuum Ejectors

WP2 Fire test for toxicity of fire effluents

1 Exam Prep NSF/ANSI Tabs and Highlights

Natural Gas Conditioning Skids & Equipments

New Waste Calcining Facility Non-Radioactive Process Decontamination

Mix and Flow of Matter Grade 8 Unit 1 Test

AP B Fluids Practice Problems. Multiple Choice. Slide 2 / 43. Slide 1 / 43. Slide 4 / 43. Slide 3 / 43. Slide 6 / 43. Slide 5 / 43

Oxygen mass transfer in a bubble column with non-newtonian fluids

ENGINEERING FLUID MECHANICS

The activated sludge process

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

3. A fluid is forced through a pipe of changing cross section as shown. In which section would the pressure of the fluid be a minimum?

PRODUCTION AND OPERATIONAL ISSUES

Bioreactor System ERT 314. Sidang /2011

. In an elevator accelerating upward (A) both the elevator accelerating upward (B) the first is equations are valid

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

ATMO 551b Spring Flow of moist air over a mountain

1. A pure substance has a specific volume of 0.08 L/mol at a pressure of 3 atm and 298 K. The substance is most likely:

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

Section 5.1 Pressure. Why study gases? An understanding of real world phenomena. An understanding of how science works.

Pub.No Flushing out your heat transfer system was a dirty job, a big expense, and a serious bummer.

ASSIGNMENT 2 CHE 3473

The Use of Radioactive Sources in Troubleshooting Gas Plant Problems. By Waleed J. Georgie PRIMAS (Oil & Gas) Consultancy, Aberdeen, Scotland

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

The New PHD 4 Portable Helium Detector

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

Simulation of Experiment on Aerosol Behaviour at Severe Accident Conditions in the LACE Experimental Facility with the ASTEC CPA Code

T004.BioTector TOC Analyzer Pressure and Flow Test failure analysis

Two interconnected rubber balloons as a demonstration showing the effect of surface tension

Slide 5 / What is the difference between the pressure on the bottom of a pool and the pressure on the water surface? A ρgh B ρg/h C ρ/gh D gh/ρ

Gianluca Gemme LN2 DISTRIBUTION PLANT

Quiz name: Chapter 13 Test Review - Fluids

Digester Processes. 1. Raw Sludge Pumping System

A. What are the three states of matter chemists work with?

1.2 Example 1: A simple hydraulic system

Chapter 13. liquids. gases. 1) Fluids exert pressure. a) because they're made up of matter and therefore forces are applied to them

Evaluation of the fraction of Unit-3 vent gas that flowed into Unit-4 reactor building

Moving Fluids Concept and Theory

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Fig. 2. M.I. Yaroslavtsev, 2002

Increase in Evaporation Caused by Running Spa Jets swhim.com

HW-1: Due by 5:00 pm EDT on Wednesday 13 June 2018 to GradeScope.

Particle Control under Wall Saturation in Long-pulse High-density H-mode Plasmas of JT-60U

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Chapter 9 Fluids and Buoyant Force

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

Applied Fluid Mechanics

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

OWNER S TECHNICAL MANUAL

Injector Dynamics Assumptions and their Impact on Predicting Cavitation and Performance

Enter your parameter set number (1-27)

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

F All types of inert gas systems are to comply with the following:

Grit chambers are basin to remove the inorganic particles to prevent damage to the pumps, and to prevent their accumulation in sludge digestors.

Effect of Argon Gas Distribution on Fluid Flow in the Mold Using Time-Averaged k-ε Models

Pressure Control. where: p is the pressure F is the normal component of the force A is the area

Deep water plume models - What s special about deep water

Chapter 13 Fluids. Copyright 2009 Pearson Education, Inc.

Experimental Study of an Air Lift Pump

Aerodynamic behavior of a discus

Zebron Gas Management

CERTIFICATES OF COMPETENCY IN THE MERCHANT NAVY MARINE ENGINEER OFFICER

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models

I.CHEM.E. SYMPOSIUM SERIES NO. 97 BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES

Application Worksheet

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

PRESSURE REDUCING VALVE RP45 (EN)

Chapter 9 Solids and Fluids

Gas Pressure. Pressure is the force exerted per unit area by gas molecules as they strike the surfaces around them.

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

Pneumatic blending in a bin or silo that is, aerating. Saving time, labor, and money with pneumatic batch blending

Technical Data Sheet MF010-O-LC

Free Surface Flow Simulation with ACUSIM in the Water Industry

Air Eliminators and Combination Air Eliminators Strainers

Transcription:

SIMULATION TEST OF AEROSOL GENERATION FROM VESSELS IN THE PRE-TREATMENT SYSTEM OF FUEL REPROCESSING* Sachio FUJINE, Koichiro KITAMURA, and Takehiro KIHAIW Department of Fuel Cycle Safety Research Japan Atomic Energy Research Institute(JAERI) Tokai-mura, Naka-gun, Ibaraki-ken, JAPAN 3 19-11 Abstract Aerosol concentration and droplet size are measured in off-gas of vessel under various conditions by changing off-gas flow rate, stirring air flow rate, salts concentration and temperature of nitrate solution. Aerosols are also measured under evaporation and air-lift operation. I. Introduction Non-volatile radioactive elements such as Pu, Np, Am, Tc, Ru, Sr, Cs and other FPs are confined in the process under normal operation of reprocessing. Almost all radioactive non-volatile fission products are actually confined in highly radioactive liquid waste. However, there are pathways for release of these non-volatile elements to the environment through off-gas and/or aqueous effluents. Radioactivity migration of non-volatile elements takes place in the facility primarily by aerosols. Aerosol generation under normal operation are caused by liquid aeration, evaporation, transportation and other handling of radioactive solutions [l-3). Important area of facility for the radioactivity migration is particularly pre-treatment process which contains highly radioactive solutions in vessels. Not only decontamination factor of filters but also radioactivity behaviors in the process play the important role in assessment of source terms of environmental releases from large scale reprocessing plant (4). Role of aerosol behavior is significant especially for the migration of non-volatile nuclides. Influences of operation condition of vessels are studied on the concentrations and droplet size of particles of aerosols in off-gas. II. Exnerimental Experimental facility(fig.1) is composed of a slab-type vessel, a condenser, an air-lift and an exhaustive blower, those are connected with pipes and valves. The slab-type vessel is aerated with air * Work performed under contract with Science and Technology Agency(STA), JAPAN. 778

nozzle submerged in the liquid of vessel. Liquid in vessel can be heated with two 5kW electric heaters. Liquid can be circulated outside by air-lift attached to the vessel. Aerosols are sampled on off-gas pipes(inner diameter 28mm) with Andersen sampler(as-500). Standard sampling time is 5 hours. Nitrate aqueous solutions, listed in Table 1, are used as the simulated radioactive solution of reprocessing. Salts concentration of sodium, lithium, and nitrate ions are total 100 and 350 g/l. Lithium is added as tracer of the solution. Li in aerosols is analyzed by ICP. Gas-Liquid separator Condenser -9 0 Stirring air -1 1 1 1 @J Carrier g&air) Fl I I-P I lllllllll w I I Adsorption tank 1 Heater NOx cylinder Feed tank,, t!ly &( TP I Air-lift Compressed Feed pump air Fig. 1 Flow sheet of experimental Heater @ (IS)Llquid phase snmpling - Gas phase piping - Liquid phase piping equipment. Liquid volume in vessel is 30L under standard condition of experiment. Distance from air nozzle submerged in solution to liquid free surface is 44cm. Distance from free surface to vessel ceiling is 55cm. Standard air stirring flow rate is 10 m3/hm2-free surface area of vessel which corresponds to a weak stirring condition of chemical process. Linear flow velocity of off-gas is in the range from 2 to 10 m/s. Required off-gas flow rate is adjusted by controlling sweeping air flow rate of the volume above the liquid free surface in vessel. Aerosols in off-gas are measured at the outlet of vessels under aeration by changing the sweeping air flow rate or stirring air flow rate as operation parameters. Properties of solutions in vessel are changed in some cases. In the case of evaporation operation, aerosols in off-gas are measured at the outlet of condenser of vessels. In the case of air-lift operation, aerosols in off-gas are 779 _ -._--.,l_,,,-l. r..i.._. - --.-..

measured at the outlet of air-liquid separator. Table 1 Properties of salt solutions used in the experiment. solution concentration density viscosity g/l Iid cm3 CP surface tension dynkm NaNOs+LiNOs in water 100 1.065 1.17 60.0 NaNOs+LiNOs in 3N-nitric acid 350 1.290 2.33 50.3 NaNOs+LiNOs TBP 1OOppm in water 100 1.065 1.12 36.9 III. Results Off-gas Flow Rate Aerosol concentrations in off-gas decreases inverse proportionally to off-gas flow rate, as shown in Fig.2. Required off-gas flow velocity is adjusted by changing the sweeping air flow rate on the liquid free surface. Stirring air flow rate is 10 m3/hm2 per free surface area of liquid in slab-tank. Aerosol concentrations are observed in the range from a few to a dozen mg/m3 under the experimental conditions. Numerical values near plots are 50% mean diameters. It is observed that mean particle size decreases from 5.3 to 2.3 P m by increasing off-gas flow rate. There must be the bigger possibility of trapping for the larger aerosol particles near outlet of slab-tank to off-gas pipe under the higher off-gas flow rate. The outlet is located at ceiling of the tank. Saturation by humid of sweeping air influences to reduce both aerosol concentration and particle size, that is shown in Fig.2 as well. Stirrine Air Flow Rate Aerosol concentrations in off-gas increases roughly proportionally to stirring air flow rate, as shown in Fig.3. This figure shows the relations between aerosol concentration at off-gas outlet of tank and stirring air flow rate for several kind of solutions. As for NaN03 3M-nitric acid solution, 780.-._..._ ----...--

aerosol concentrations are less than 10 mg/m in the range of less than 30 m3/hm2 stirring air flow rate. A separate peak of the smaller particle size in addition to the main peak of the bigger particle size is observed in the aerosol size distribution for the higher range of stirring air flow rate in the experiment. 18 liquid temperature : Stirring air flow rate : 10m3/hm2 Numerical values near plots are 50% mean diameters. 0 2 4 6 Off-gas flow velocity(m/s) 8 10 Fig.2 Aerosol concentration in off-gas depending on off-gas flow velocity Salts Concentration Figure 3 shows that a solution of 350 g/l NaNOs+LiNOs-3M nitric acid gives the smaller aerosol concentrations in off-gas approximately by half than a 100 g/l NaNOs+LiNOs aqueous solution does. Both viscosity and density are bigger for 350 g/l NaNOs+LiN03-3M nitric acid solution. Viscosity is 2.33 CP and density is 1.290 g/cm3 for the solution. On the other hand, viscosity is 1.17 CP and density is 1.065 g/cm for 100 g/l NaN03+LiNOs aqueous solution. Two peaks size distribution are more often observed for the higher salts concentration. 781 _-I_ -..-...

TBP Addition Extractant TBP is added by 100 ppm to a 100 g/l NaN03+LiN03 aqueous solution. Surface tension of the solution is decreased to 36.9 dyn/cm from 60.0 dyn/cm of 100 g/l NaNOs+LiNOs aqueous solution. Figure 3 shows that aerosol concentration in off-gas increases significantly by 2 to 5 times by TBP addition. 140 120 100 80 60, I 1 Liquid I I I 0 : NaN03+LiN03aq. sol.(li cow. app. lg-li/l) 0 : (Li cow. app. Jg-Li/l) :Li cow. increased I I A : TBPlOOppm added(li cont. app. lg-li/l) :Surface tension decreased,*. 0 : 3N nitric acid solution(li cont. app. 3g-Lib) a :Viscosity and density increased 8 Liquid temperature:20cy25~ : Off-gas flow velucity:3.9-4.8mh.* Numerical values war plots we 50% mean diameten..,,*..,- ** Stirring air flow rate for free surface area of liquid(m3/hm2) Fig.3 Aerosol concentration in off-gas depending on stirring air flow rate for different kind of solutions. Temnerature Increase Liquid temperature in slab-tank was changed in the range from 20 to 60 C by using two 5kW electric heaters submerged in the solution. Aerosol concentrations in off-gas are increased by increasing temperature, as shown in Fig.4. Surface tension decrease by increasing temperature must be primary cause for the aerosol increase. 782

Significant aerosol increase is observed at 60 C in particular. More particles of smaller size are observed for the higher temperature. Liquid:NaN03+LiN03(app.100g/l)aq. sol.(app. lg-li/l) Numerical values near plots are 50% mean diameters. I I I 20 40 I 60 I Liquid temperature(c) Fig.4 Aerosol concentration in off-gas depending on liquid temperature. Air-lift Ooeration Characteristics of air-lift depends on submergence ratio. Submergence ratio is defined as the ratio of depth of air-lift submergence beneath free surface to total head of lifting liquid. Air-lift was operated by adjusting submergence ratio at 0.3 by keeping app. 30L solution volume in slab-tank. Solution was recycled through air-liquid separator and pot to slab-tank. Diameter of air-lifting pipe is 12.7 mm. Aerosol sampling was carried out for 5 hours on vent pipe from air-liquid separator. Aerosol concentration in off-gas from air-liquid separator are related to linear velocity of air in air-lifting pipe, as shown in Fig.5. Lifted liquid velocity is also shown in the figure. Aerosol concentrations are roughly proportional to air velocity. And it is observed that aerosol concentrations are in the range from a few to several hundreds mg/m3 in this experimental range. Air-liquid separator 783

actually has no function to remove aerosol from off-gas. Demister should be applied to reduce aerosol migration to the downstream of off-gas from air-liquid separator.,. 3001 I I I I I 30 3 B z- 200 Liquid:NaNO,(app. 100gIl)aq. sol. (app. lg-li/l) Liquid temperature:30r Off-gas flow velocity:6.0sh27.0cnus Liquid volume in slab-tank :30L(Submergence ratio 0.3) 1 Residence time in gas-liquid separator :1.3-8.7min Hold-up in gas-liquid separator:lsl Liquid head for air-lifting:l.s54m Ratio of air flow rate/lifted liquid flow rate 25 I r(i I I I I 1 20 40 60 S'O 100 120 148 Air velocity of air-lift(crn/s) Fig.5 Aerosol concentration in off-gas at outlet of air-liquid separator and lifted liquid velocity depending on air velocity of air-lift. Evanoration Evaporation of solution in slab-tank was carried out at the evaporation rate in the range from 1.4 to 7 L/h. Standard evaporation rate is assumed to be 10% liquid volume in one hour, this rate corresponds to 3 L/h in this experiment. Evaporation rate was controlled by heater output and measured by condensate level increase in pot. Inner pressure of slab-tank was adjusted in the range of app. -80 to -200 mmh20 by exhaustive blower operation. Off-gas flow velocity was adjusted at 4 m/s at off-gas outlet of condenser by controlling carrier air which sweeps the volume above free surface in 754

slab-tank. Aerosol sample was collected at the off-gas outlet of condenser for one hour. Aerosol concentration and migration rate to outlet of condenser are related to evaporation rate, as shown in Fig.6. Dependence of aerosol migration rate on evaporation rate is not apparently clear in this experiment. Aerosol concentrations are observed in the range from 2 to 7 mg/m3 in off-gas. Hourly migration ratios are calculated in the range from 6.2~10.~ to 1.7~10. Hourly migration ratios are defined by the ratio of migration rate to outlet of condenser divided by total amount of solution in slab-tank. 1 d 23.1 1 0 1 2 3 4 5 6 7 8 Evaporation rate (L/h) Fig.6 Aerosol concentration in off-gas and aerosol migration rate to the outlet of condenser, depending on evaporation rate. IV. Conclusion Aerosols in off-gas are measured at outlet of vessel under -various operation condition using 785..ll,--,_- -- Z.-----e--

simulated nitrate solutions to understand the behavior of non-volatile radioactive elements under normal operation of reprocessing. Experimental results show the following conclusions. (1) Aerosol concentrations in off-gas at outlet of vessel are observed in the range from a few to 20 mg/m3 in the range of off-gas flow rate 2 to 10 m/s, stirring air flow rate up to 50 m3/hm2, liquid temperature 20 to 45 C. Aerosol concentration of less than 10 mg/m is observed at stirring air rate less than 30 m3/hm2 for 350 g/l NaNOs+LiN03-3M nitric acid solution. (2) Decrease of liquid surface tension by adding trace amount of TBP increases aerosol concentration in off-gas by 2 to 5 times that of nitrate solution without organic additives. (3) Aerosol concentrations in off-gas from air-liquid separator are observed in the range from a few to several hundreds mg/m3. Aerosol removal should be applied to reduce aerosol migration to the downstream of off-gas from air-liquid separator. (4) Aerosol concentrations in off-gas from condenser of vessel under evaporation operation are observed in the range less than 10 mg/m3. Acknowledgements Authors are grateful to Dr.Y.Naito(Director of the Department of Fuel Cycle Safety Research), Dr.M.Maeda(Director of the Department of NUCEF project) and Mr.G.Uchiyama(Process Engineering Lab.) for technical discussion and guidance. References (1) J.Furrer, K.Jannakos, A.Linek, J.Wilhelm, H.Braun, ANS Inter.Meet.Fuel Rep. Waste Manag. Vol.11. p. II-3 19(1984). (2) K.Nagel, J.Furrer, 19th DOE/NRC Nucl. Air Clean. Conf. NUREG/CP-0086, p.706(1986). (3) J.Furrer, A.Linek, RKrissel, K.Jannakos, 19th DOE/NRC Nucl. Air Clean. Conf. NUREG/CP- 0086, p.688( 1986). (4) JNFS R-91-001(1991). 786

DISCUSSION DORMAN; One would expect fairly rapid evaporation of some of the aerosols so size would depend markedly on position of sampling. Did you carry out size measurements at more than one point? FUJINE: Yes, we measured the aerosol sizes at different points, namely, different distances less than 2 m from the vessel in which aerosols are generated. Average sizes of aerosols observed were not different markedly. Regarding evaporation, we made measurements on the size distribution of aerosols in humidified and non-humidified carrier air. Aerosols in humidified air consist of smaller sizes than those in non-humid&d air. However, the difference is not big, approximately 10%. Sampling point was just at the outlet of the vessel. I think the non-humidified air was partially humidified to some extent in our experiment. 787