Part 1 - Data Processing and Quality Control.

Similar documents
Methods Used in Measuring Surface Seawater pco 2 Aboard RVIB Nathaniel B. Palmer

Part 1 - Data Processing and Quality Control.

Part 1 - Data Processing and Quality Control.

Part 1 - Data Processing and Quality Control.

Part 1 - Data Processing and Quality Control.

Part 1 - Data Processing and Quality Control.

Part 1 - Data Processing and Quality Control.

Part 1 - Data Processing and Quality Control.

Part 1 - Data Processing and Quality Control.

Part 1 - Data Processing and Quality Control.

REPORT OF UNDERWAY pco 2 MEASUREMENTS IN SURFACE WATERS AND THE ATMOSPHERE DURING July (RVIB Nathaniel B. Palmer Cruise 00/5)

Taro Takahashi, Colm Sweeney, S. C. Sutherland. Lamont-Doherty Earth Observatory of Columbia University Palisades, NY

REPORT OF UNDERWAY pco 2 MEASUREMENTS IN SURFACE WATERS AND THE ATMOSPHERE DURING February - March (RVIB Nathaniel B. Palmer Cruise 01/2)

F:\Ships\lmgould\2003\lmg03_2\surface\LMG03_2_data_report.doc Page 107/27/17 12:55 PM

F:\Ships\NBPalmer\2001\nbp01_3\surface\NBP01_3_data_report.doc Page 104/26/17 4:13 PM

F:\Ships\NBPalmer\2002\nbp02_2\surface\NBP02_2_data_report.doc Page 104/25/17 3:33 PM

F:\Ships\NBPalmer\2001\nbp01_4\surface\NBP01_4_data_report.doc Page 106/02/15 11:21 AM

F:\Ships\NBPalmer\2003\nbp03_4a\surface\NBP03_4A_data_report.doc

REPORT OF UNDERWAY pco 2 MEASUREMENTS IN SURFACE WATERS AND THE ATMOSPHERE DURING February - April RVIB Nathaniel B. Palmer Cruise 03/4

F:\Ships\NBPalmer\2002\nbp02_1\surface\NBP02_1_data_report.doc Page 103/19/15 11:16 AM

F:\Ships\NBPalmer\2003\nbp03_1a\surface\NBP03_1a_data_report.doc Page 104/24/17 2:54 PM

COMPARISON OF SURFACE WATER pco 2 AND SST DATA DURING AN ENCOUNTER OF RVIB PALMER AND RV GOULD ON MARCH 13, 2009

Under way pco 2 System Users Manual

WHP Operations and Methods { July William M. Smethie, Jr. Lamont Doherty Geological Observatory Palisades, New York U.S.A.

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

Uniform format surface fco 2 database Benjamin Pfeil and Are Olsen Bjerknes Centre for Climate Research, Bergen, Norway

CTD Data Documentation

Technical Report by Peter Guenther and Charles D. Keeling Carbon Dioxide Research Group Scripps Institution of Oceanography La Jolla, CA

Cover Page for Lab Report Group Portion. Pump Performance

Generating Calibration Gas Standards

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

This test shall be carried out on all vehicles equipped with open type traction batteries.

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Lung Volumes and Capacities

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Another convenient term is gauge pressure, which is a pressure measured above barometric pressure.

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Helium Mass Spectrometric Leak Detection In Large Size Process Plants

Application Note 268 Metabolic Analysis Systems and Propane-based Verification

11/22/ (4) Harmonization: <846> SPECIFIC SURFACE AREA

Best Practice Guide, Servomex 2700

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Instruction Bulletin Addendum For Pressure-Balanced In Situ Oxygen Probes

Operation manual Oxygen sensor

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

CORESTA RECOMMENDED METHOD N 6

Model PDT Dewpoint Transmitter

Constant Pressure Inlet (CCN) Operator Manual

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

Standard Test Methods for Water Vapor Content of Electrical Insulating Gases by Measurement of Dew Point 1

Boyle s Law: Pressure-Volume Relationship in Gases

Application Note 183. Page 1 of Aero Camino, Goleta, CA Tel (805) Fax (805)

Flow in a shock tube

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

Focus on VOC Emissions Reduction Using an Oxygen Based Inerting Control System For Inert Gas Blanketing of Chemical Process Vessels

Chapter 10 Gases. Characteristics of Gases. Pressure. The Gas Laws. The Ideal-Gas Equation. Applications of the Ideal-Gas Equation

EASIDEW TRANSMITTER with Current Source Output

Mitos Fluika Pressure and Vacuum Pumps Datasheet

Naval Postgraduate School, Operational Oceanography and Meteorology. Since inputs from UDAS are continuously used in projects at the Naval

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

Sampling Considerations for Equilibrium Dissolved Oxygen [DO] Sensors

Kinetic-Molecular Theory

GCMSD-Headspace Analysis SOP

APPLICATION NOTE. GC Integrated Permeation Device

CHAPTER 3 RESULTS AND DISCUSSION

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Cover Page for Lab Report Group Portion. Lift on a Wing

Transmitter CS 21 Operation Manual

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

628 Differential Pressure Decay Leak Tester

Experiment Instructions. Circulating Pumps Training Panel

The Helium Leak Detector

AMT-Ex Dewpoint Transmitter

Module 2, Add on Lesson Depth Sensor. Teacher. 90 minutes

Air Monitoring Directive Chapter 7: Calibration

Sensor Stability. Summarized by Breck Owens David Murphy, Sea-Bird Electronics AST-14 Wellington March 18-21

What I have learned about SF 6 gas testing.a Practical explanation

Application Note AN-107

Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

Module 9. Advanced Data Processing

HS Bubbler Technology. HyQuest Solutions New Zealand User Group August 2017

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Columbus Instruments

Characterizers for control loops

O2100C Oxygen Measurement Module Technical Use Notes do not use other wall adapters with the O2100Cmodule. 10% / V 5% / V 2% / V 1% / V 10% / V

LFE OEM TCD - Thermal Conductivity Detector

Lab 1. Adiabatic and reversible compression of a gas

Mass Flowmeters. Mass Flowmeters for Gases

Dissolved Oxygen Meter. ino2. Instruction Manual. Serial No..

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Manual for continuous distillation

NMISA NEW GAS FLOW CALIBRATION FACILITY. Deona Jonker 7 October 2013

Transcription:

REPORT OF UNDERWAY pco 2 MEASUREMENTS IN SURFACE WATERS AND THE ATMOSPHERE DURING March/April 2006 R/V Laurence M. Gould 06/3 S. C. Sutherland, Timothy Newberger, Taro Takahashi, and Colm Sweeney Lamont-Doherty Earth Observatory of Columbia University Palisades, NY 10964 16 March, 2017 Part 1 - Data Processing and Quality Control. 1. General a) Cruise Overview 1) The cruise does not have a title in the operating schedule. She departed Punta Arenas on 21 March. She visited Palmer Station after the southbound transit, and returned to Punta Arenas following the southbound track almost exactly, arriving on 4 April. 2) We have applied the revised algorithm for correcting for the time lag between water passing the remote temperature probe and arriving at our equilibrator. We move the pco 2 data one scan earlier. b) Data Overview 1) Generally, the pco 2 data are very good. There were a few periods where flows were interrupted, but for the bulk of the cruise, however, the system worked very well. The data from "Equil#2" has been deleted as it was seriously inconsistent with the regular equilibrator data. 2) The temperature probe in the pco 2 system is normally adjusted using a set of calibration constants.

3) The remote thermosalinograph (TSG) temperature probe data in this cruise is consistently warmer than the equilibrator temperature, and is used as Sea Surface Temperature. The system failed near the beginning of Julian Day 92 and was replaced with the spare after about 12 hours. 4) The atmospheric pco 2 observations were not very well behaved. When the apparent wind was near dead ahead they seemed to settle on a value near 377 ppm, but realistic statistics are not possible.. We continue to use the Globalview CO2 data for calculating air-sea pco 2 difference, primarily for consistency with earlier cruises. 2. Standards: Cylinder Concentration (ppm) Nitrogen (UHP) 0.0 CA06684 120.66 CA06616 359.49 CA06653 252.31 CA06650 506.25 CA06644 385.30 A 4 th order calibration curve is used with 5 standards, not including the Nitrogen, as described in Section 2. The calibration curves are also plotted in Section 4. Standards flow for about 120 seconds before an observation is made., 3. Details of pco2 data. a) There were 3,187 individual seawater pco 2 observations, 115 were rejected, leaving 3,072 valid records. b) There were 8 observations which were highlighted in the data stream. These were apparently where air data was being measured for NOAA/PMEL. The details follow: JDATE ID TYPE PCO2_MEAS VCO2RECALC TEMP_PCO2 TSGTEMP TSGSAL FLOW 91.51165 LMG0603S 0 346.9 352.16 2.71 2.450 33.740 55.0 91.78578 LMG0603S 0 353.7 360.44 3.68 3.470 33.710 50.0 92.23117 LMG0603S 0 369.4 384.19 6.10 5.890 27.890 51.0 92.74555 LMG0206 0 368.2 378.18 6.83 6.590 33.570 39.0 93.03891 LMG0206 0 370.3 379.36 7.30 7.130 33.980 51.0 93.14168 LMG0206 0 363.0 372.09 9.45 9.340 33.560 51.0 93.39439 LMG0603S 0 364.8 373.46 9.92 9.730 32.760 51.0 93.71482 LMG0206 0 354.1 365.67 10.14 9.980 32.910 48.0 4. Details of temperature data. a) The temperature of water in the equilibrator is monitored continuously using a Guildline platinum resistance thermometer (readable to 0.05 o C and regularly calibrated

against a mercury thermometer traceable to N.I.S.T.) and recorded on the data-logging computer. The calibration curve is integrated into the LabVIew program that operates the system and acquires the data. The pco 2 temperature is then a calibrated value. We make an effort to check this calibration during cruises against a mercury thermometer. b) The Documentation file for the TSG is contained in a pdf file which was printed and attached to this report. The TSG Serial Number (S/N) was 3208. Since the last cruise used S/N 1577, we assume that was the instrument which failed on day 92, and was replaced by S/N 3208 5. Details of Salinity data. a) Past experience has shown that the TSG system is quite stable, but with no Autosal determinations, we call the remainder "UNcalibrated." 6. Details of the air data a) There was substantial spiking in the air data. It remains very difficult to filter the "bad" data out of these observations. Using the relative wind we can extract a group of reasonable determinations. There were 552 air determinations. We rejected all but 85.

Part 2 Description of Instrumentation a) The LDEO Underway System for Surface Water pco 2 Measurements: The underway pco 2 measurement system for surface waters consists of a) a water-air equilibrator, b) an analyzer system based on a non-dispersive infra-red CO 2 gas analyzer, c) sample pumps, d) 5 calibration standards and e) a data logging system. The measurement system is schematically shown in Fig. 1, and is similar with the one described in Bates et al. (1998). Each of these units and the data reduction procedures used will be described below. Figure 2: Diagram of the underway pco 2 system used for surface water pco 2 measurements during NBP04-03 which is essentially identical to the Gould System.

b) Water-air Equilibrator: The equilibrator has a total volume of about 30 liters and is equipped with a standpipe that is isolated from the headspace and automatically maintains a constant water level at about half the height of the equilibrator leaving about 15 liters of headspace (Figure 2). Seawater from the ship s uncontaminated water line is continuously pumped into the equilibrator at a rate of about 10 liters/min, giving a mean residence time of water in the equilibrator of about 1.5 minutes. The headspace above the water serves as an equilibration chamber. A carrier gas (commonly marine air) is continuously circulated to and from the head space in a closed loop by a diaphragm pump, and exchanges CO 2 with the continuous flow of seawater sprayed into the chamber through a spiral cone spray nozzle. Because of large gas-water contact areas created by fine water droplets as well as gas bubbles in the pool of water, CO 2 equilibration between the carrier gas and seawater is achieved rapidly with a e-folding time of 2 to 3 minutes. Under normal sampling conditions, about 50 ml/min of this sea water equilibrated air is directed into the infra-red gas analyzer. The air drawn for analysis is replaced by a controlled leak into the equilibrator through the water manometer. At this rate, the residence time of the carrier gas in the equilibration chamber is about 300 minutes, that is about 100 times as long as the equilibration time. Therefore, the carrier gas in the head space should always be in equilibrium with the seawater. The over all response time of the equilibrator system has been estimated to be of an order of several minutes. The large volume of water in the equilibrator was chosen to provide a large thermal inertia in the equilibrator, so that the effects of room temperature changes on the equilibration temperature may be minimized. The temperature of water in the equilibrator is monitored continuously using a Guildline platinum resistance thermometer (readable to 0.05 o C and regularly calibrated against a mercury thermometer traceable to N.I.S.T.) and recorded on the data-logging computer. The water manometer is attached to the gas intake end of the equilibrator (Figure 2) and provides a visual confirmation that marine air is being returned to the equilibration chamber at the same flow rate that it is being diverted to the CO2 analyzer. The manometer also isolates the equilibrator head space from free exchange with the ambient marine air. The low head of the water manometer ensures that the equilibration chamber pressure is nearly identical to ambient atmospheric pressure. The total pressure at which the gas was equilibrated, can then be measured outside the equilibrator using a precision electronic barometer (Setra Model 270, Action, MA). This equilibration pressure is also logged on the computer. The temperature and salinity of seawater at the in situ conditions were measured using a SeaBird Model SBE-21 thermosalinograph aboard the N. B. Palmer and a SIO/ODF thermosalinograph unit based on Neil Brown sensors aboard the R. Revelle. The precision of the reported temperature data has been estimated to be about 0.005 o C. c) Infra-red CO 2 Gas Analyzer: The equilibrated gas was passed through a water trap (to collect condensate,) and, and a reverse flow naphion dryer (PermaPure flushed with pure nitrogen gas) to remove water vapor (to a level of 20 o C dewpoint), and was introduced into the IR sample cell at a rate of about 50 ml/min for CO 2 determinations. A LI-COR infra-red gas analyzer

(Model 6251, Lincoln, NB) was used. After a 2-minute purging period, the gas flow was stopped and readings were recorded on the computer. Although the CO2 analyzer has an electronic circuit to linearize the CO 2 response, it exhibited a few inflexions that deviated from linearity by a few ppm. Therefore, the pco 2 system has been designed to use the raw voltage output of the CO2 analyzer to establish our own calibration curves using five standard gas mixtures (one pure nitrogen and four CO 2 -air mixtures). The CO 2 concentrations in the gas mixtures were calibrated using the SIO standards determined by C. D. Keeling s group using the manometric method. The concentrations of CO 2 in the standard gas mixtures were summarized above. During normal operations approximately every 75 minutes each of the standard gas mixtures was passed through the analyzer for 120 seconds at a rate of about 60 ml/min. This flow rate and time was redundantly sufficient to completely purge the IR analyzer cell with the new gas. The flow was stopped for 10 seconds to allow the pressure in the cell to equilibrate to atmospheric pressure and the average of 20 separate millivolt readings from the analyzer was recorded. Following the five standard gases, samples of seawater-equilibrated air and ambient marine air were pumped through the analyzer for 120 seconds (2 minutes) each at rates of about 50 ml/min and 60 ml/min respectively to purge the previous sample in the IR cell. The flow was stopped for 10 seconds and the average of 20 separate millivolt readings from the analyzer was recorded. This procedure was intended to eliminate errors due to fluctuations of the dynamic pressure within the IR cell by irregular gas flow rates. The relatively slow flow rates used for seawater-equilibrated air samples were required for the removal of water vapor using the PermaPure membrane dryer. We analyze 30 seawater-equilibrated air samples and 5 ambient marine air samples between two sets of calibration runs using the five standard gases. d) Data Logging System: The following values were recorded on a laptop computer. The sample locations were derived from the ships Global Positioning System (GPS). The CO 2 readings for seawater equilibrated air samples were recorded approximately every 3 minutes, and those for the standard gas mixtures approximately every 90 minutes. Time/Date stamp (GMT), CO 2 analyzer voltage output (to 0.1 mv) Analyzer cell temperature (to 0.1 C) Barometric pressure (pco 2 system barometer) (to 0.1 mbar) CO 2 concentration (to 0.1 ppm, preliminary value based on the last response curve) Equilibrator temperature (to 0.01 o C) pco 2 (uatm, preliminary value based on the last response curve) Gas flow rate (to 0.1 cc/min) Selector valve position (integer) Sample ID (standard gas cylinder numbers, seawater CO 2, atmospheric CO 2 )

The ships RVDAS system adds several other data elements from various sensors and equipment including: Latitude, Longitude, Thermosalinograph temperature, thermosalinograph salinity, fluorometer voltage, wind speed, wind direction, barometric pressure (at ships instrument mast), water flow in the uncontaminated seawater line. e) Data Reduction Procedures: The concentration of CO 2 in the sample was computed in the following manner based on the millivolt reading and time of the reading. The millivolt reading taken for each of the five standard gases at the time of sample measurement was computed by linearly interpolating as a function of time using the readings taken before and after the respective standard gases were analyzed. This yields an interpolated millivolt reading for each of the five standard gases at the time when the sample was analyzed. These five values were fit to a fourth-order polynomial equation (with five constants to be determined). This serves as the response curve. The CO 2 concentration in the sample was computed using the response curve that was established at the time of each sample analysis. This method has been demonstrated to yield more reliable CO 2 values compared with those computed, for example, using a least-squares fit of a quadratic or cubic functions to the five calibration points. The method described above yields atmospheric CO 2 values that are consistent (within 1.5 ppm) with those reported for the South Pole and the Cape Grim by the Climate Monitoring and Diagnostics Laboratory/NOAA in Boulder, CO. The partial pressure of CO 2 in seawater, (pco 2 )sw, at the temperature of equilibration, Teq, in the unit of microatmospheres (µatm) was computed using the expression: (pco 2 )sw @ Teq = (VCO 2 )eq x (Peq Pw),......[1] (VCO 2 )eq Peq Pw = the mole fraction concentration (ppm) of CO 2 in the dried equilibrated carrier gas; = the barometric pressure (that is equal to the total pressure of equilibration) in atmospheres; and = the equilibrium water vapor pressure at Teq ( o C) and salinity. The water vapor pressure was computed using the following formulation; Pw (atm) = (1/760)x(1 5.368x10-4 x Sal) x EXP{[0.0039476 (1/TK)]/1.8752x10-4 },... [2] where Sal is salinity on the Practical Salinity Scale and measured using the ship s thermosalinograph, and TK is the temperature of equilibration in o K. The (pco 2 )sw at the in situ temperature, T in situ, was computed using a constant value of 0.0423 % per o C for the effect of temperature (Takahashi et al., 1993):

(pco 2 )sw @ Tin situ = (pco 2 )sw @ Teq x EXP[0.0423 x (Tin-situ Teq)]. The value for Tin situ is taken to be the seawater temperature measured by the ship s thermosalinograph at the time of pco 2 measurements. Teq is generally warmer than Tin-situ by 0.5 ~ 0.8 o C. Hence the temperature correction is normally less than 3% of pco 2 values. The over all precision of the reported (pco 2 )sw values has been estimated to be about +1.5 uatm. f) Atmospheric Measurements: The air measurement system is also shown schematically in Fig. 1. Uncontaminated marine air samples were collected about 10 m above the sea surface using a 1/4 i.d. thin-walled aluminum tubing protected by an exterior plastic casing and an internal plastic film lining (Synflex, Calco Inc., PA). The air intake was located at the middle of the foremast about 10 m above the sea surface. A KNF Neuberger air pump located near the IR analyzer was used to pump air through the tubing and into the IR analyzer. Even when air samples were not analyzed, air was continually flowing through the sampling line to continuously purge the long Synflex tubing with fresh marine air. For analysis, the air sample was passed through a 0.5 micron filter to remove aerosols and a drying column to remove water vapor (the same PermaPure column as used for the seawater-equilibrated air) and introduced into the IR cell for CO 2 analysis at a rate of about 60 ml/min. For each sample the cell was purged for 120 seconds, the flow was stopped for 10 seconds and the average of 20 IR millivolt output readings was recorded on the computer. g) Atmospheric Data Processing: The partial pressure of CO 2 in the air, (pco 2 )air, was computed in the unit of microatmospheres (µatm) in the same way as that for seawater using Eq. [3] below: (pco 2 )air = (Vco 2 )air x (Pb Pw),......[3] (Vco 2 )air Pb Pw = the mole fraction concentration (ppm) of CO 2 in the dried air sample; = the barometric pressure at sea surface in atmospheres; and = the equilibrium water vapor pressure at Tin situ ( o C) and salinity given by Eq. [2]. The precision of the atmospheric pco 2 values have been estimated to be about + 1 µatm.

Part 3 - References Bates, N. R., Takahashi, T., Chipman, D. W. and Knapp, A. H. (1998). Variability of pco 2 on diel to seasonal time scales in the Sargasso Sea. Jour. Geophys. Res., 103, 15567-15585. CO 2 Group, Lamont-Doherty Earth Observatory. (2004) Underway pco 2 System Users Manual, LDEO of Columbia University, Palisade, NY, pp.23. Takahashi, T., Olafsson, J., Goddard, J., Chipman, D. W. and Sutherland, S. C., (1993). Seasonal variation of CO 2 and nutrients in the high-latitude surface oceans: A comparative study. Global Biogeochemical Cycles, 7, 843-878.

PART 4 - Graphics List of Figures: Maps showing the location of each seawater pco 2 and SST value with the data point assigned a color based on an indicated color palette. 3-panel time series of verious parameters, five each for the southbound and northbound legs. Northbound has been deleted from the final file. A time series showing salinity data with editing.

Part 5 - Program Listings These listings provide detailed documentation of processes applied to the data, including the calculation of a reponse curve, editing, and certain quality control operations.