Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

Similar documents
Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Pressure Reducing Valve for Steam Type 2333 A

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Mounting and Operating Instructions EB EN. Self-operated Pressure Regulators. Type 2335 Excess Pressure Valve with pilot valve

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Self-operated Pressure Regulators for special applications

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

EB EN. Type 44-0 B Steam Pressure Reducing Valve Type 44-1 B Pressure Reducing Valve. Translation of original instructions

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Application Notes for Valve Sizing Sizing valves for steam service with the aid of sizing charts

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Instruction Manual Contact Pressure Vacuum Gauge

Bermad Pressure Reducing. Model: 42T

Declaration of Conformity as per Directive 97/23/EC

Declaration of Conformity as per Directive 97/23/EC

Pressure Regulators. Operating Instructions. Instrumentation

Mounting and Operating Instructions EB 9520 EN. Differential Pressure and Flow Meter Media 05

Mounting and Operating Instructions EB 9520 EN. Differential Pressure and Flow Meter Media 05

1800C and 1800C-HC Series Service Regulators

Declaration of Conformity as per Directive 97/23/EC

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Mounting and Operating Instructions EB 9519 EN. Differential Pressure and Flow Meter Media 5. Zero adjuster

Model: 43T. Bermad Pressure Relief Valve

Type 4708 Supply Pressure Regulator

USER MANUAL Version: 1/2017

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

INSTALLATION OPERATION MAINTENANCE

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Pressure Reducing Valve DMV 750

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Installation, commissioning and servicing instructions

Art PRESSURE REDUCER

WW-730. Pressure Sustaining/Relief Control Valve

Pressure Relief Valve DHV 718

1200B2 Series Service Regulators. Instruction Manual

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

SRV66 Sanitary Pressure Reducing Valve

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Overview of types. Technical data. Safety notes

Non-Return Valve SRK 22A

Pressure Reducing Valve DMV 750 set range: bar

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Declaration of Conformity as per Directive 97/23/EC and Manufacturer s Declaration as per Directive 98/37/EC

WW-720. Pressure Reducing Control Valve

High Performance BSP Dial Up Pattern Pressure Reducing Valve

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Pressure Reducing Valve

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

INSTALLATION, OPERATION

Double valves for biogases and recycling gases

Commonwealth of Massachusetts Approved Product Approval code G

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

TITAN FLOW CONTROL, INC.

Installation, commissioning and servicing instructions

WW-720. Pressure Reducing Control Valve

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Inverted Bucket Steam Trap IB 16A-7

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation, commissioning and servicing instructions

Installation & Operation Manual Proven Quality since 1892

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E

Type overview. R B2 en-gb subject to changes 1

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Model PIV UL/FM Post Indicator Valve. Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines...

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Contents. 1. General information BROEN BALLOMAX Steel Ball Valves Approvals Quality Management...2

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Airtester HP for compressed air according to EN 12021

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Operating manual Steam trap

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Transcription:

Self-operated Pressure Regulators Pressure Reducing Valves Type 50 ES Type 50 EM Type 50 ES Type 50 EM Fig. 1 Pressure reducing valves Mounting and Operating Instructions EB 2555 EN Edition November 2011

Safety instructions General safety instructions The regulators must be installed, started up and serviced by fully trained and qualified personnel only, observing the accepted industry codes and practices. Make sure employees or third persons are not exposed to any danger. All safety instructions and warnings in these instructions, particularly those concerning installation, start-up and maintenance, must be observed. For appropriate operation, make sure that the regulator is only used in applications where the operating pressure and temperatures do not exceed the operating values based on the sizing data submitted in the order. Note that the manufacturer does not assume any responsibility for damage caused by external forces or any other external factors. Any hazards which could be caused in the regulator by the process medium or operating pressure are to be prevented by means of appropriate measures. Proper shipping and appropriate storage are assumed. Definition of the signal words used in these mounting and operating instructions NOTICE Indicates a property damage warning. Note: Indicates supplementary explanations, information and hints. 2 EB 2555 EN

Design and principle of operation 1 Design and principle of operation The pressure reducing valves consist of a valve with seat and soft-seated plug and a valve bonnet with an operating diaphragm, positioning spring(s) and a set point adjuster. Type 50 EM has a pressure gauge connection instead of a stopper (Type 50 ES). The connected pressure gauge indicate the downstream pressure p 2. The pressure reducing valve is designed to maintain the pressure downstream of the valve to an adjusted set point. The valve is open when it is depressurized. The valve closes when the pressure downstream of the valve rises above the adjusted set point. The process medium flows through the valve between the seat (7) and the plug (8) in the direction indicated by the arrow. The position of the valve plug determines the flow rate and, hence, the pressure ratio across the valve. The downstream pressure p 2 is transmitted to the operating diaphragm (4) and converted into a positioning force. This force is used to move the valve plug over the plug connection link (6) depending on the force of the positioning spring(s) (3). The spring force can be adjusted at the set point adjuster (1). p 1 p 2 1 3 4 5 6 7 8 9 1 Set point adjuster 3 Spring(s) 4 Operating diaphragm 5 Body 6 Plug connection link 7 Seat 8 Soft-seated plug 9 Stopper or connection for pressure gauge p 1 p 2 Upstream pressure Downstream pressure Fig. 2 Sectional drawing of Type 50 ES EB 2555 EN 3

Installation 2 Installation 2.1 Mounting position The pressure reducing valve can be installed in any desired position. The medium must flow through the valve in the direction indicated by the arrow on the valve body. NOTICE Protect the regulator against frost when the process medium (e.g. water) can freeze. Remove the valve from the pipeline while the plant is shut down. Note: Thoroughly flush the pipeline prior to installation of the valve! Otherwise sealing particles, globules and other impurities carried along by the process medium could impair the proper functioning of the valve, especially the tight shut-off. 1 2 3 4 5 1 1 Shut-off valve 2 Pressure gauge for upstream pressure 3 Strainer 4 Type 50 ES Pressure Reducing Valve 5 Pressure gauge for downstream pressure 2.2 Strainer Install a strainer (SAMSON Type 1 NI with a mesh size of 0.25 mm) upstream of the pressure reducing valve. Make sure the process medium flow corresponds with the direction indicated by the arrow on the strainer. In horizontal pipelines, install the strainer with the filter element suspended downwards. In upright pipelines where the medium flows upwards, install the strainer with the drain flange of the filter element facing upwards. In this case, the dirt particles are only retained, but not collected. Ensure that enough clearance is provided to remove the filter. 2.3 Shut-off valve and pressure gauge We recommend installing hand-operated shut-off valves both upstream of the strainer and downstream of the pressure reducing valve. This allows the plant to be shut down for cleaning and maintenance routines or when the plant is not operated for extended periods. Install pressure gauges both upstream and downstream of the pressure reducing valve in order to monitor the pressures prevailing in the plant. Type 50 EM has a mounted pressure gauge to indicate the downstream pressure p 2. Fig. 3 Typical installation 4 EB 2555 EN

Operation 3 Operation During start-up, fill the plant slowly with the process medium. NOTICE The pressure at the regulator must not exceed the maximum permissible operating pressure for the regulator. 3.1 Set point adjustment Adjust the downstream pressure required by turning the set point adjuster (1). Turn the set point adjuster clockwise ( )to increase the downstream pressure Turn the set point adjuster counterclockwise ( ) to reduce the downstream pressure The pressure gauge mounted on the Type 50 EM Pressure Reducing Valve allows the adjusted set point to be monitored directly at the pressure gauge. 4 Maintenance NOTICE Remove the valve from the pipeline prior to performing any work. Make sure the relevant section of the plant has been depressurized and, depending on the medium, drained as well. The pressure reducing valve is maintenance-free, but is subject to wear and tear, especially at the seat and plug. Depending on the application conditions that prevail, the valve must be inspected at appropriately scheduled intervals to prevent any problems before they occur. If the valve does not shut off properly, this may be due to dirt between the seat and plug preventing tight shut-off or due to wear. If external leakage occurs, check the operating diaphragm for leaks and replace the regulator, if necessary. Prior to performing any cleaning routine, remove the pressure reducing valve from the pipeline. Proceed 1. Tension the spring(s) by turning the set point adjuster (1) clockwise ( ) to lift the plug out of the seat. 2. Rinse the valve from both sides with water to remove any dirt from the seat and plug. 3. Release the spring tension by turning the set point adjuster counterclockwise ( ) and reinstall the valve in the pipeline. EB 2555 EN 5

Dimensions 5 Dimensions 6 Customer inquiries 60 Type 50 EM and Type 50 ES 113 37 Connection G 3/8 G ½ Weight, approx. All dimensions in mm Fig. 4 Dimensional drawing 0.7 kg Should any malfunctions or any defect occur, SAMSON's After-Sales Service is prepared to help you on site. You can also send the defective regulator directly to your local SAMSON representative for repair. Addresses of SAMSON subsidiaries, agencies and service centers are listed in the product catalogs and in the Internet at www.samson.de. To allow SAMSON to find the fault and to have an idea of the installation situation, specify the following details (refer to the nameplate): Type and nominal size of the valve Model number with index Upstream and downstream pressures Temperature and process medium Min. and max. flow rates Has a strainer been installed? Installation drawing with exact location of the regulator and all additionally installed components (shut-off valves, pressure gauges etc.). 6 EB 2555 EN

EB 2555 EN 7

SAMSON AG MESS- UND REGELTECHNIK Weismüllerstraße 3 60314 Frankfurt am Main Germany Phone: +49 69 4009-0 Fax: +49 69 4009-1507 Internet: http://www.samson.de EB 2555 EN 2011-11