How many intakes can I operate from the control center? Up to 4 intakes can be controlled from the control center.

Similar documents
SWS Option: Well Pressures. SWS Option: Stretch Correction (Corrected depth) SWS Option: MMD (Magnetic Marks Detection) ASEP Products

REACTOR 40 MECHANICAL Configuration Guide

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

New AQF Filter Polymer Filtration System

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

WATER CONTROL SYSTEM QUICK START

BUBBLER CONTROL SYSTEM

444C DUAL PERFORMANCE VALUE PACK

Driver Operator Pumps: Water Supplies. 2 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition

400C & 450C DUAL PERFORMANCE VALUE PACKS

TANKTRONIC. STANDARD CONFIGURATION Single Tank. ADVANCED CONFIGURATION Multiple Tanks. Twin Tank (common valve) Twin Tank (separate valves) Vent box

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Job Sheet 1. Geothermal Energy

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker.

Guidelines on Surveys for Dynamic Positioning System

BUYER S GUIDE AQUAlogger 530WTD

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

TurboDraft Fire Eductor

Sterisil Ac+ Installation & Operating Manual

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

PRC CO ² -LASER PRESENTATION

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Product Overview. Product Description CHAPTER

Flow Material Length. Weight GPM LPM. Style 3095

FAQs. General. There are many ways to get information about us:

Midas Method Betting Software 3.0 Instruction Manual

Tank Level Sensors. AVTECH offers normally closed (NC) and normally open (NO) versions of the Water Tank and Fuel Tank Level Sensors.

AN-140. Protege WX SALLIS Integration Application Note

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

Project Title: Pneumatic Exercise Machine

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Aquavar SOLO 2 Frequently Asked Questions

RPS900W Redundant Power Supply. Installation Guide.

200 PSI FAST-FILL AIR SOURCE KIT

Quick Start Setup Instructions for Raven LRC & AgXcel Harness for NH3 Profile plus GX40 Synergist

KEG PUMP. Range of Electric Keg Pumps

Airflow Options for Cisco MDS 9396S SAN Switch

New product release. Universal Rebreather Monitor (URBM) Single O2 cell and Dual HP package

Sport NGIN has two applications, which can be used to score games.

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI COMPRESSORS - MODEL NUMBERS

When fishing gets tough, trust Fish Hawk. For over 30-years Fish Hawk Electronics has been giving anglers speed, temperature, and depth information

HAWK-EYE INNOVATIONS LTD THE HAWK-EYE TENNIS COACHING SYSTEM

GolfNow Central. Rates & Inventory User Guide. February 2018

Connect with Confidence NO POWER NO PROBLEM

DIGITAL AUTOMATIC TYRE INFLATOR

Burner Management System DEMO Operating instructions

icon i150 / i350 Installation / Operation Manual

Declining Weight Blending System Quick Start Manual E Main St Marshall, IL Phone: Fax: Website:

AR740 RPS Redundant Power Supply Quick Install Guide

Accessories. Valves. Adjustable Pressure Relief Valves

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

New product release. Universal Rebreather Monitor (URBM) Three cell / Independent backup

Pressure switch Type BCP

GRUNDFOS industry GRUNDFOS CR MONITOR. Intelligent warning

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

EZ Boom 2010 System for the EZ Guide 500 Lightbar Triangle Ag Services Users Guide

SwimNumber App. Build Custom Smart Workouts Control the Wave Propulsion TM System Achieve Health and Fitness Goals INSTRUCTION MANUAL

WELCOME TO THE FUTURE OF TELEVISION. User Manual

RM-80 respiration monitor

Operating instructions Electrical switching facility pco

PROCESS MONITORING AND CONTROL

Calcium Reactor. CalcFeeder PRO. User Manual 1.1a. Model. CalcFeeder AC1 PRO CalcFeeder AC2 PRO CalcFeeder AC3 PRO CalcFeeder AC4 PRO

Product Guide. Crawler Crane

IMPORTANT SAFETY INSTRUCTIONS

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

100C Air Compressor Kit

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

DASSAULT AVIATION Proprietary Data

NGP-250/500 Nitrogen Generator Quick Start Guide

EasyTouch. Because automation makes it all so simple. Pool and Spa Control Systems. By Pentair Water Pool and Spa

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

CONTROL and INSTRUMENTATION

Operating Instructions Part No

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Tire Inflation Cage Kit For servicing only single piece automotive, and most light truck tire/wheel assemblies

For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch)

South-Tek Systems - Nitrogen Generation Corrosion Inhibiting System. Designed for: Dry or Preaction Fire Protection Systems (FPS)

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

EWC EARLY WARNING CONTROL OPERATIONAL PRESENTATION. Charles Dickens (757)

Marschalk Model # 94000

XC2 Client/Server Installation & Configuration

EZ-Boom 2010 Automated Application Control System Quick Reference Card INTRODUCTION

MJB4 Mask Aligner Operating Procedure. Effective Date: 07/12/2012 Author(s): Jiong Hua Phone:

T EK-SUB 4800C 19 mm Submersible Level Transmitter

NITROGEN INFLATION SYSTEM NG-4, NG-6, NG-12, NG-18

MFD Monroe Fire Department. Standard Operating Guidelines. Drivers Clearance & Training Program Guidance ADMINISTRATION

Operating Instructions Part No

FRDS GEN II SIMULATOR WORKBOOK

Dynamic Positioning Control Augmentation for Jack-up Vessels

AutoChanger Installation & User Guide Issue 2

Accessories. Valves. Adjustable Pressure Relief Valves

SonoSelect 10 and SonoSafe 10 energy meters

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

Transcription:

FAQs SYSTEM FUNCTIONALITY What is the maximum operating pressure? The maximum system operating pressure is determined by the equipment on the truck and not limited by the SAM system. Since the maximum operating pressure for the Akron valves is 250psi, that is your system limitation. You can set each discharge at a different maximum pressure lower than 250psi though. How many discharges can I control from SAM? SAM can control up to 12 discharges and have 6 active at the same time on the control center. While we hope you don t get into the situation where you need more than 6 discharges running at the same time from one apparatus, the system has the same capability as your fire truck does today to run as many lines as you want. If you need more than 6 active lines, you can switch to manual mode and open as many lines as you want. The system won t manage each line to a set pressure anymore, but you ll still have your traditional PSI mode to manage the master discharge pressure. How many intakes can I operate from the control center? Up to 4 intakes can be controlled from the control center. Will the system alert me if there is a problem? The system comes standard with a speaker to alert the operator and others on the fireground when critical events are happening with the waterflow or truck. It includes beeps to get the operators attention followed by spoken details of what is happening so the operator can react right away. Will the system automatically close my discharge valves or accidentally cut water off? Nope. Never. SAM will not close valves or cut water off to the crew unless the operator tells him to close the valve. The system alerts the operator if there are any problems and if there is a problem with a valve, wiring or connection the valve will simply stay right where it is until the operator troubleshoots the problem or closes it manually.

Do I need to set my pressure governor at a certain pressure or RPM? Nope. SAM takes care of all of that for you. The only thing you need to do is set the pressure for any discharges you want to open or select the intake to open on the control center. SAM will manage engine speed in the background to maintain discharge pressures and manage intake transition. What parameters can I configure on the system for my department? The system is customizable and configurable to your department. The configurable parameters are: Valve names and colors Individual presets can be set for every discharge. Each preset can be a different value based on your department s guidelines. This way you can make sure every pre-connect gets set to the proper pressure on every fire. Quickset pressures for each discharge can be set to the home screen. You pick up to four of your most frequently used discharges and then put them on the home screen. That will move that discharges preset to the home screen for super easy access. Max operating pressure for each discharge Percentage for Low tank warning level (when does the system alert the operator the tank is low) Can I draft with the system? Yes. SAM makes drafting easy. The system will automatically pre-prime up to your intake valve and then open the valve once priming is complete. After the source is established, SAM will close the tank-to-pump valve. What functionality do I have on the tablet? The tablet is essentially a duplicate of the Control Center. The operator can controo their intakes, discharges and tank from the tablet. They will also see any warnings or errors. Manual mode is not available from the tablet though. If manual mode is needed the operator will need to go back to the truck. If you need to pump from multiple locations, you can also add up to two (2) additional truck mounted control centers. Why do I have a pump controller too? The pump controller plays an important role in the system. It is there to provide traditional pressure governor functions, pump health info, tank valve controls, optional video input and engine data. Most of the time it is just a reference next to the control center and the operator does not need to interact with it. In manual mode, it provides traditional pressure governor control. Can SAM control foam or CAFS? Yes. From the Discharge Control screen on the Control Center you can turn on or off Foam or CAFs if Class 1 SmartFOAM or SmartCAFS is installed.

TRUSTING SAM AND REDUNDANCIES What happens if the control screen fails? There are multiple layers of redundancy. Within the SAM system. If the screen itself fails then you can operate from a second SAM screen, the tablet or optional navigator controllers on the panel. If all else fails, every valve has a manual override on it that can be used to open and close the valves. The engine speed can still be controlled from either the pump controller or the Twister. What are my backups? There are several options for backups to the system today. Check out more details in the Trusting SAM section here. What temperature will the system work in? The system is designed, tested and proven to work from -40 F to 130 F SPECIFYING SAM How much does it cost? Pricing has not been released yet and will depend on your OEM. If you re interested in learning more I d be happy to get you in touch with our product experts that can get your some more details. What other hardware do I need? SAM requires Akron electric valves, Hale pumps and Class 1 tank level gauges and is provided as a complete integrated system. What if I want other valves, pumps or electronics? It s not available with other manufacturers equipment. To provide a reliable, tested and proven system it is only available as a complete package from IDEX Fire & Safety. Can I buy it now? Yes. SAM is available to specify now and we re excited you re ready to transform your pump operations. TECHNICAL What voltage does the system operate on? The system is a 12V system and designed to be used with 12V DC power supplied to it. How does the system communicate with all of the components? SAM s backbone is the standard J1939 CAN bus communication protocol that has been around for decades and is reliable and proven. The system communicates the same way the engine and transmission and pump pressure governor communicate on the chassis.

WIRELESS TABLET What is the range of the tablet? The tablet is designed to allow freedom of movement around the truck and allow the operator to be positioned where they can be most effective. It is not intended to be a long distance control device and each department should establish appropriate operating procedures for your department. Reliable operation has been tested and proven from normal pump operator positions on the fireground. How does it communicate with the truck? It communicates on a closed wifi network that is dedicated to only the tablet and not able to be used for anything else. So you re telling me there is a router on the truck? Is it like the one in my living room? The wireless tablet uses secure wireless technology. It s not like the router in your home or work. It only communicates with the tablet and nothing else and is a dedicated link back to the truck. You can t log into it with your phone or laptop. OTHER Can I have a mix of manual valves and electric on my truck with the SAM system? Nope. The SAM system is only available with all electric valves. A mixed system is not available. Can I retrofit the system to an existing truck? Unfortunately, No. The system is not retrofittable at this time. How do I perform my annual pump test? SAM has a manual mode that allows the operator to control the valves directly and includes the standard pressure governor functions so pump testing can be done exactly as it has been in the past. Do I need to have multiplexing on my truck? Although we recommend it, multiplexing is not required for SAM. Can I operate SAM from any of my multiplexing trucks? Unfortunately you can t. SAM is a closed network that includes only the parts required to control your water flow on the truck intakes, discharges, tank and pump. It cannot be connected to other multiplexing screens. Is this system compatible with Captium? The system is on a J1939 bus so Captium will be able to capture SAM parameters and display on the Captium dashboard once integration is complete with the Captium system.

If I have multiple control centers on the truck, which one is the master? Each control center and tablet are equal inputs to the system. When an operator sends an input to the system it is reflected on all available control centers and tablets. Can I lock out the control centers on the truck when I am using the tablet? There is no option to lock out the control center during tablet use. If an operator is making changes to the system at the tablet it will be seen at the other control centers on the truck. Can I use this with the QTwo pump for higher pressures? We are not supporting two stage pumps at this time but we are looking at it. SAM is available on Qmax and Qmax-XS pumps.