Figure Source:

Similar documents
Evaluation of Ground Ring vs. Equipotential Mat at a Swimming Pool in Buford, Georgia

Check with local zoning official for property line distance requirements.

Bulletin Swimming pool, hot tub and spa installations Rules , , , , , and

Swimming Pool Requirements

PART I. GENERAL REQUIREMENTS FOR PERMANENTLY INSTALLED POOLS, STORABLE POOLS, OUTDOOR SPAS, OUTDOOR HOT TUBS, OR FOUNTAINS

SWIMMING POOL REQUIREMENTS

Swimming Pool Requirements Packet

Definitions for swimming pools, fountains, and similar installations in article 680

Florida Building Code 6 th Edition (2017) Residential. Broward County Edition Loose-leaf Supplement

CONTINUING EDUCATION FOR WISCONSIN ELECTRICIANS NEC Article Hours

GFCIs and Swimming Pools A Natural Fit

SWIMMING POOLS CHAPTER 41

City of Crystal Lake Community Development Department

CHAPTER 42 SWIMMING POOLS

PERMANENT POOLS. Location

AMITY TWP POOL REQUIREMENTS

SWIMMING POOL & SPA DOCUMENT SUBMITTAL LIST

Nottingham Township 909 Sugar Run Road Eighty Four PA (724) Fax (724)

Swimming Pool Electrical Safety

PRIVATE SWIMMING POOL AND SPA/HOT TUB INFORMATION PACKAGE

2012 International Residential Code with the 2016 CT Amendment PRIVATE OUTDOOR SWIMMING POOL INFORMATION PACKAGE

City of Lockport Above Ground Pool Regulations

RESIDENTIAL POOL, SPA AND HOT TUB PERMIT REQUIREMENTS

General Requirements of the NEC Advanced Course. Building Officials and Inspectors Educational Association

Sunbrite LTC Large Underwater Pool Lights

RESIDENTIAL SWIMMING POOLS, SPAS and HOT TUBS PERMITTING and INSPECTIONS GUIDE

$ Plan Review Fee when Permit Application is submitted HOT TUBS AND SPAS BUILDING PERMIT APPLICATION. COST: $80.

Swimming Pools, Hot Tubs and Spas

IntelliChlor Power Center (For use with IntelliChlor model IC60, IC40 and IC20)

RESIDENTIAL SWIMMING POOLS, SPAS and HOT TUBS PERMITTING and INSPECTIONS GUIDE

Electrical. OSHA Office of Training and Education 1

RESIDENTIAL SWIMMING POOL REQUIREMENTS

SWIMMING POOL, SPAS, HOT TUB REQUIREMENTS AND GUIDELINES (Updated 3/2018)

Spectrum AquaLight (SAL ) Color Underwater Light Owner s Manual

Electrical Safety. Introduction

This training session covers electrical safety for unqualified persons. Unqualified persons are machine operators, operators of powered industrial

SWIMMING POOL PERMITS ARE ABOUT HEALTH AND SAFETY

SWIMMING POOL BUILDING PERMIT REQUIREMENTS FOR THE UNINCORPORATED TERRITORY OF DOUGLAS COUNTY, KANSAS

Residential Swimming pools

POOL AND HOT TUB/SPA REGULATIONS A BUILDING PERMIT IS REQUIRED BEFORE THE INSTALLATION OF A POOL.

GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST

Lincoln County Environmental Health Department 302 North Academy Street, Suite B Lincolnton, NC Phone: Fax:

RESIDENTIAL SWIMMING POOL

RESIDENTIAL SWIMMING POOLS AND SPAS A GUIDE FOR HOMEOWNERS

SALT GENERATOR FOR ABOVEGROUND POOLS

Address: South Elgin, IL Phone: ( ) - Fax: ( ) - Cell: ( ) - Phone: ( ) - Fax: ( ) - Cell: ( ) - Contact Type:

Sunbrite Large Underwater Pool Lights

The purpose of this brochure is to explain to owners and contractors the City of Burnaby s requirements for private swimming pools.

APPLICATION FOR A PERMIT TO CONSTRUCT OR ALTER A PUBLIC SWIMMING POOL, SPA POOL, WADING POOL OR FOUNTAIN

Fence and Swimming Pool Permit Guidelines

Address: South Elgin, IL Phone: ( ) - Fax: ( ) - Cell: ( ) - Phone: ( ) - Fax: ( ) - Cell: ( ) - Contact Type:

Acknowledgement must be given for the assistance provided by Barry Hutchens, Kenji Iwanaga, and AJ Murguia in preparing this booklet.

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

TOWN of CHEEKTOWAGA Permit Application for Swimming Pools, Hot Tubs, or Personal Spas

GENERAL NOTES FOR SWIMMING POOLS AND SPAS

Building Department Informational Handout

Whitehall Township Swimming Pool, Spa and Hot Tub Code Guide

Electrical. Version 1.0

Smart JVA Module WARNING. For use with AquaLink RS systems with rev R firmware or newer.

Swimming Pools, Spas & Hot Tubs Construction requirements for outdoor private swimming pools (in-ground and above-ground), spas and hot tubs

Ground Fault Circuit Interrupter(GFCI) Policy

Eaton County Department of Construction Codes. Requirements for, Swimming Pools, Hot Tubs and Spas in Michigan

ROCKDALE COUNTY NEW SWIMMING POOL PLAN REVIEW

Series WARNING. FOR YOUR SAFETY - This product must be installed and serviced by professionals who are

Chapter 10 SWIMMING POOLS

Swimming Pool Permits are About Health and Safety

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Definitions found in several locations:

Building Standards Department Pool Requirements 111 N. Michigan AV, Bradley, IL Phone Fax PRIVATE SWIMMING POOLS

FITNESS, SAFETY & MEDICAL SUPPLIES

Covered Task 409OP Training Guide Inspecting Interference Bonds

FPA 70 From The 2008 Edition National Electrical Code

Project Name: Om Vihar- Affordable Group-Housing Project Promoter: Om Bhakt Real Estate LLP RISK ASSESSMENT

Aquavar SOLO 2 Frequently Asked Questions

2017 Florida Building Code 6 th Edition, Public Swimming Pool Changes, FBC Section 454.1, Effective January 1, 2018

PERIODIC INSPECTION REPORT FOR AN ELECTRICAL INSTALLATION

MDX² INSTALLATION MANUAL (RETROFIT FIBERGLASS, VINYL & CONCRETE POOLS WITH MDX)

City of DuBois PERMIT APPLICATION P. O. Box 408, 16 West Scribner Ave - DuBois, PA Phone: Fax:

MISSOURI UNIVERSITY OF SCIENCE & TECHNOLOGY Procedure: 3.6

Inline Salt System OWNER'S MANUAL. For Models: 15,000 gallons 25,000 gallons 40,000 gallons

Swimming Pool Installation

Welcome to a NECA Webinar based on the National Electrical Code. This seminar is the second in a series of electrical grounding and bonding Webinars

Part 3: Safety Rules for the Installation and Maintenance of Underground Electric Supply and Communication Lines

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.

INSTALLATION INSTRUCTIONS AT-SERIES ANCHOR ASSEMBLY PART NUMBER: F-04CAJP 450 LB. [204kg] MAXIMUM CAPACITY (PRO POOL LIFT)

Private Swimming Pool Permit Application

D E L U X E S E R I E S. Your Hot Tub Pre-Delivery Guide D E L U X E

Copies of your pool operator certificate as well the operating permit must be posted at the pool. The operator s certificate is your certificate that

FINDLAY TOWNSHIP BUILDING INSPECTION DEPT

Original Date of Issue: 04/09

LoneStar Fiberglass Pools. Do-It-Yourself. Installation Manual

Applications and Considerations Section 11

Owners Manual Release Date: Thursday, December 29, 2011

NO wiring shall be above the pool within 10, measured horizontally, or under a pool within 5, measured horizontally.

ARCHITECTURAL GUIDELINES 1000 S

Your Hot Tub Pre-Delivery Guide

Salt Sanitizing System for Above Ground Pools Up to 25,000 Gallons

MV-105 MEDIUM VOLTAGE CABLE. 5kV, 8kV, 15kV, 25kV & 35kV

Saskatchewan Health S A WHIRLPOOL DESIGN/OPERATIONAL T C H E W STANDARDS. Updated 02/00

ARCHITECTURAL GUIDELINES ONE-PIECE COMMERCIAL

Transcription:

In the Fall of 2018, EPRI opened a test facility to the public so that they could witness testing at the EPRI swimming pool assessment infrastructure within EPRI s laboratory in Lenox, Massachusetts. Those tests demonstrated that during 120-Vac line faults, over 100 milliamps of current can be conducted through a human body when a single bare copper ring that is compliant with NEC Article 680.26 is used as the equipotential bonding means. This finding reveals a significant safety gap in the current version of the NEC (National Electrical Code). The key takeaway from the testing is that it is not possible to develop an equipotential bond (with the dirt or the earth) beneath the pool deck. However, a safe zone of equipotential protection can be created with enough conductive grid material either within or beneath the deck surface. The safe zone will keep humans who stand on that surface at a reasonably close equipotential, regardless of what else is impressed during 60-Hz line faults or from the buildup of any static charge. Doug Dorr EPRI Technical Executive, manager of the supplemental research project Contact and Stray Voltage Assessment, and author of this recommendation document oversees testing and demonstration of a safe pool design. EPRI presented the test results and conclusions regarding safety gaps to the NEC s code-making panel (17 members) in October of 2018, and a majority of the members present that day voted to recommend an appropriate code change that would protect pool users when these uncleared electrical faults happen. A day later, that vote was inexplicably overturned after several panel members met with opponents of the proposal and changed their vote. It is not entirely clear why a few of members of the NEC code-making panel would even remotely consider changing their minds on a code enhancement related to a safety gap, but the following screen capture (taken on 11-21-2018) from one of the opposition parties websites explains a possible cost-over-safety aspect of their argument.

Figure Source: http://apsp.org/advocacy/issuespositions/the-issue-national-electric-code Although the NEC is not likely to move quickly to eliminate this safety gap in the existing code, EPRI has a public-safety mission that warrants promoting fact-based scientific findings and recommendations as detailed in the following paragraphs. With the concepts of equipotential surfaces and electrical bonding well understood, the pool industry is able to develop recommendations to promote effective electrical safety in pool environments. The following sections describe leading practices for safe design for new construction and for retrofit. Users of these recommendations should keep in mind the two key foundational pillars of safety that underpin this work: A. Equipotential The pool water and the surface of the decking areas within the span of human contact need to be at near or the same voltage potential under all conditions. This is only achievable if there is a conductive metallic grid (either within or under the pool deck area), and that grid must be adequately interconnected or bonded to the pool water. B. Electrical Interconnectivity No bonding or interconnection pathways should exist to allow an accidental or intentional connection between the pool water and the grounding and bonding network of the facility electric power system. Note that although ground fault circuit interrupters should be used on all electric circuits feeding pool circulation equipment and lighting, a circuit interrupter will not provide protection for item B. EPRI Recommended Practice for New Construction (Both Conductive and Non-Conductive Pools) Follow and adhere to all equipotential bonding requirements of the 2005 version of the National Electrical Code (NEC Article 680.26-2005). This particular version of the code requires that for conductive pool types (such as rebar-formed concrete), the rebar grid must extend three feet out from the inner side of all pool walls. This gridded shell and gridded deck creates an equipotential surface between the pool water and the three-foot extension where people sit or stand poolside. The 2005 code version also states that if the pool is a non-conductive type, or for construction where the rebar used is encapsulated in an insulating compound, or if the deck is going to be comprised of materials other than poured concrete, a supplemental copper grid is required for the deck. This version of the code disallows the single bare copper conductor, which has been shown by multiple test organizations to be inadequate and unsafe during electrical fault conditions. 2

The important difference between the grid and the single wire is that the equipotential bonding grid creates a safe zone for the deck surface, whereas a single wire does not. Further, EPRI also recommends an enhanced zone of protection, whereby the installer extends the grid out to at least four feet from the pool water and installs that grid as close to the surface of the deck as feasible. EPRI believes that a fourfoot zone of protection provides an additional factor of safety for people using a pool surface skimmer with a metal hand. The following is offered as a complete specification: Click HERE to see a day of pool testing conducted at the EPRI Lenox Laboratory and actual test results. A. Deck Area Grid A conductive metallic grid (of 12 inch by 12 inch or smaller squares) should be used for any perimeter decking areas within four feet of the pool s inner wall. B. Width and Depth It is preferred to encase the grid in the decking material. However, if the grid cannot be encased within the decking material, it should be as close to the surface of the decking subgrade as feasible and should be made of a material and connectors that are suitable for direct burial and suitable for longevity in an environment of chemically treated water. C. Underwater Lighting No 120-Vac lighting and no metal conduits in conductive niches or metal retaining rings should be used in the pool walls or within five feet of the pool area. Only twoconductor, 12-V LED lighting in non-conductive enclosures and non-conductive conduit should be used. The key point here is to eliminate any metal and ensure that nothing metallic or electrically conductive approaches the pool inner wall. Further, if low-voltage (such as 12-volt) LED lighting is used, the two conductors feeding the LED fixtures must be electrically isolated from the grounding and bonding infrastructure. D. Bonded Parts No conductive metal parts should be installed within five feet of the inner pool wall. This means no metal handrails, no metal ladders, and no other conductive hardware. Suitable highimpact vinyl versions of this hardware are available. E. Bonding Conductors for Pumps and Heaters NEC Article 680.26 generally requires a bonding conductor that connects to all of the other electrical equipment (such as pumps, heaters, and control units) and then connects all of this equipment back to the equipotential bonding ring of the pool area. The bonding connection over to the pool area is not endorsed by EPRI because this connection provides an unintended pathway for electrical faults to get to the pool water. As an alternative means, EPRI recommends that all electrical equipment be located in the same area and that the equipment bonding lugs be interconnected to one another and connected directly to the ground bus of the electric subpanel. This provides a suitable pathway for equipment faults to be cleared by the overcurrent protective device without exposing pool users to the dangers posed by a neighbor s fault or by a fault on other circuit in the facility. Installers should be aware that the recommendation in item E) is new, and most authorities having jurisdiction will be hesitant to allow this deviation from current practice. If that is the case, refer them to 3

this EPRI publication, which articulates the unsafe aspects of bringing the circulating system bonding conductor over to the pool s bonding network. If the authority having jurisdiction is still concerned about the circulation system being interconnected with the pool water, a suitable workaround is to put a water-bonding device with at least nine square inches of surface area directly into the circulation pipes where the pipe connects to the pump. Be sure to use the version that inserts at the circulating pump and do not use the version that inserts at the skimmer end. EPRI Recommended Practice for Existing In-Ground Pools (Both Conductive and Non-Conductive) All equipotential bonding means in the vicinity of a chemically treated swimming pool will undergo corrosive aging over time. Therefore, for existing pool construction, the following is recommended: 1. An annual inspection of the water voltage gradient. 2. An annual inspection of the equipotential bonding integrity. 3. Monthly physical operation and testing of all GFCIs and all breakers. Note: For each of the tests, all electrical equipment supporting the pool area should be operational and energized. The water voltage gradient test can be most simply accomplished by walking the perimeter of the pool and using a device similar to the one described at THIS WEBSITE, or else by measuring with a voltmeter and two floating electrodes a few feet apart. The assessment of equipotential bonding can be accomplished with measurements detailed in IEEE 1695-2016, Guide to Understanding, Diagnosing, and Mitigating Stray and Contact Voltage. Simply put, we are ensuring that all bonded parts are maintaining a low-impedance connection between one another and that no corrosion to the bonding grid has occurred over time. If there is a missing bond or if the connections have corroded over time, the continuity test with an ohm meter will generate a resistance greater than one half ohm, and a measurement of the voltage difference between the ground rod of the power service and the various bonded parts in the pool area may show a voltage difference when the pool-circulation equipment is operating. For most meters, the voltage difference is measured across a load resistor, and the value of the voltage difference is compared to the value obtained by just touching the meter test leads together. If a voltage difference is identified between any of the bonded parts specified in NEC 680.26 or between the bonded parts and the water, the pool should be closed to use, and remediation is recommended as follows: A. The pool owner should consider a conductive metallic grid (of 12 inch by 12 inch or smaller squares) for any perimeter decking areas within four feet of the pool inner wall. For both conductive and non-conductive shells, this grid should be bonded to an NEC 680.26-compliant equipotential bonding ring at four or more different points around the pool perimeter and bonded to the water through approved means. B. If option A) is not feasible, the pool owner should consider removal of all conductive elements that are physically accessible to swimmers, including 120-V underwater lighting and wiring. Conductive 4

ladders, handrails, and poles used to skim debris off the water surface should be replaced with nonconductive and non-metallic hardware. C. Lastly, because the circulation system for the pool water uses a pump and many times uses a supplemental heater, the NEC requires that they be bonded to the other conductive parts in the pool area. Adhere to the recommendations in item E) from the new construction pools list in the previous section. 5