www.lampslighting.co.uk
Features: IP65 (dust tight & water jet proof) Corrosion resistant Energy efficient Osram LEDs Choice of 3 LED outputs Average 5, hrs LED life - maintenance free Optimum single bin LEDs with a 3 MacAdam ellipse tolerance High lumen output superior illuminance to a to a conventional compact fluorescent (CFL) Wall or ceiling mounting Contemporary design Options: Suffix part code in order: Available with an integrated Manual Intelligent Control (MIC): / MIC1 / MIC2 MIC2 / MIC3 Integral 3hr maintained emergency 3 versions of trims available: smart, visa & grill Visa version for control of light pollution Tamper resistant torx screw suffix part code / T Choice of body finishes Mistral Smart LED Material: Body: die-cast aluminium Lens: polycarbonate Finish: Trim: black or metallic grey Lens: opal Spares All components are available from Lamps and Lighting s UK manufacturing facility. Mistral Visa LED 65 These luminaires are designed to comply with EN 6598-1 (BS 4533:11) Emergency EN 6598.2.22 (BS 4533:12.22) Mistral Grill LED
Mistral Smart LED MGY Mistral Visa LED MGY Mistral Grill LED MGY Mistral Smart LED Mistral Visa LED Mistral Grill LED MIC Compatibility Mistral Smart Equivalent CFL Type Black Base Emergency Black base Metallic Grey Base Emergency Metallic Grey Base LAMS 14/B E3-LAMS 14/B LAMS 14/MGY E3-LAMS 14/MGY LAMS 24/B E3-LAMS 24/B LAMS 24/MGY E3-LAMS 24/MGY LAMS 44/B E3-LAMS 44/B LAMS 44/MGY E3-LAMS 44/MGY Mistral Visa LAMV 14/B E3-LAMV 14/B LAMV 14/MGY E3-LAMV 14/MGY LAMV 24/B E3-LAMV 24/B LAMV 24/MGY E3-LAMV 24/MGY LAMV 44/B E3-LAMV 44/B LAMV 44/MGY E3-LAMV 44/MGY Mistral Grill LAMG 14/B E3-LAMG 14/B LAMG 14/MGY E3-LAMG 14/MGY LAMG 24/B E3-LAMG 24/B LAMG 24/MGY E3-LAMG 24/MGY LAMG 44/B E3-LAMG 44/B LAMG 44/MGY E3-LAMG 44/MGY
MIC Manual Intelligent Control The Manual Intelligent Control (MIC) system features a range of advanced sensor technology controls offering the ultimate in energy saving and carbon reduction. Significant energy savings can be achieved with a MIC system that dynamically manages lamp power according to the instantaneous lighting requirement. It ensures that the right level of light appears at the right place only when required, this preventing unnecessary energy consumption and potentially reducing maintenance costs. The MIC system has been installed in over 3 BT telephone exchanges with confirmed energy savings in excess of 7%. There are three types of Manual Intelligent Control: MIC1, MIC2 and MIC3, available as a master (sensor incorporated) or a slave (controlled by master), to suit different requirements and budgets. The manual intelligent controls are programmed manually by a dip switch to switch on and off automatically to maximise cost savings. is a versatile and cost-effective OFF ON OFF energy saving control unit. /MIC1 OFF switched off. ON luminaires illuminate at full output unless there is sufficient daylight and the lux level setting overides it. OFF Absence after a preset time, luminaires switch off completely. /MIC1S 4K with black base and intergrated MIC1 master system: LAMG 14/B/MIC1 offers all the benefits of the but with a DIM ON DIM function. is an ideal control for reducing energy consumptions whilst still providing some level of illumination for extra safety. /MIC2 DIM on at a courtesy preset dimmed level. Approximately 2% output and 1/3 total power. ON luminaires illuminate at full output. DIM Absence after a preset time of absence, luminaires return to the courtesy preset dimmed level. /MIC2S 4K with black base and intergrated MIC2 slave system: LAMG 14/B/MIC2S is the most flexible energy saving manual control with an OFF ON DIM OFF function, permitting full light management and maximum energy saving. /MIC3 OFF ON DIM OFF switched off. luminaires illuminate at full output. After a preset time of absence, luminaires dim to the courtesy preset dimmed level. Approximately 2% output and 1/3 total power After continued absence over a preset time, luminaires switch off completely. If required, the off function can be disabled to operate as a /MIC3S 4K with black base, emergency version and integrated MIC3 master system: E3-LAMG 14/B/MIC3 www.lampslighting.co.uk
MIC Manual Intelligent Control MIC Operating Functions and Features Operating function Lux level adjustment 2 lux Time adjustment to courtesy preset dimmed level Time adjustment to switch off completely 1 3 mins Sensitivity (range) adjustment 2 1 metres 2 1 metres 1 6 metres Dimming level (ilite ballast/driver) 1/25/5% 1/25/5% Detection angle Sensor maximum load (inductive) Detection Area & 2 Mounting Height (metres) Mounting Height (metres) 3.5 1 8 6 4 2 2 4 6 8 1 Detection area (metres) Setting 1 =2metres Setting 2 = 5 metres Setting 3 =1metres 8 1 8 6 4 2 2 4 6 8 1 Detection area (metres) Setting 1 = 1 metre S etting 2 = 3 metres Sett ing 3 = 6metres Typical Installation Options Option One The masters are all working independently for maximum energy efficiency to create a cascade effect. This is ideal for a retrofit installation. Option Two The master is working in conjunction with a slave to illuminate a specific zone. The master will control the slaves. Option Three The masters and the slaves are working in conjunction to illuminate a larger area. Option Four The masters are working together for maximum energy efficiency and sensitivity in a zoned area. Option Five All masters are working together for maximum sensitivity and control of a complete area.