Lipodrop 2.0 device coating

Similar documents
Basic Flows in a Microfluidic Device

Double Emulsion Droplet generation and collection protocol Version Author Date Reviewer Change 1 Introduction

The pipettes cover a volume range from 0.1µl to 10ml.

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

RayPette Plus Autoclavable Pipette. User Manual

Pipettor. User Manual

Figure 1: Plug in ion inlet of mass spec

INSTRUCTIONS: CHEMICAL ANALYSIS OF ACTIVE SULFIDES IN OIL-BASED DRILLING FLUID

Emulsiflex C3 Homogenizer Protocol

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

Using the Akta Prime plus October 22, 2012

Patients Guide for Self Administering Intravenous Antibiotics General points

Alfred ECMO Circuit Priming and Storage Guide

Pipetting Small Volumes

Unblocking the MicroSprayer Aerosolizer Model IA-1C With the High Pressure Reverse Cleaning Adapter. Instructions for Use

Before you start sampling, be sure to read

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02

[USING THE VITROBOT April 9, Using the Vitrobot

Pipette apparatus. Meet the difference. Manual. T E I

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

Operating Instructions

SOP: Buck Scientific BLC-20P HPLC Operation

Installation of Your SprayMaster System

QUICK START GUIDE TO DRINKING WATER MONITORING

Unblocking the MicroSprayer Aerosolizer Model IA-1B With the High Pressure Reverse Cleaning Adapter. Instructions for Use

USER GUIDE, VOL.2.0 MYOGRAPH SYSTEM - 112PP/114P

WATER TREATMENT SYSTEM OPERATION MANUAL

LABORATORY TECHNIQUES. Pouring Liquids

User Manual MFCS TM -EZ

MassWWP Standard Operating Procedure R-2 Dissolved Oxygen Rev.0 Page 1 of 10

USER'S GUIDE. Nanoflow Probe. Red Stripe. 3-4mm. ptfe Sleeve. To Injector. ZU1XC Fused Silica TTF115. Fused Silica. ptfe Sleeve

PRESSURE MYOGRAPH - 114P PULSATILE PRESSURE MYOGRAPH - 112PP

Reinforce design of experiments theory Make individual factorial designs and conduct analysis on responses

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes

7.9. Flash Column Chromatography Guide

CART FOR CENTURION 1500+

Sunrise Fountain Water Wonders Assembly & Mounting Instructions

Vapor Sorption Analyzer

RECONSTITUTION AND ADMINISTRATION INSTRUCTIONS FOR HEALTHCARE PROFESSIONALS

Fiber Optic SMA Z-Flow Cell Manual Version 2.1

NanoSight NS300. NanoSight NS300. Operation instructions. Laser Spectroscopy Labs, UCI

PARTICLE SPACING PART 1

UPPER ARM INTRA-MUSCULAR INJECTION SIMULATION KIT USER MANUAL

Microfluidic Demonstration

Blue Thumb Test Procedures

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

Intermolecular Forces

Ultrasound Compatible Lumbar Puncture/ Epidural Simulator

Peripheral Venous Catheter Placement Simulator

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

TapeStation Tips & Tricks

Arterial Puncture Wrist

MOLEBIO LAB #1: Microquantity Measurement

Lab Equipment ANALYTICAL BALANCE

Vibration isolation system 1VIS10W. User manual

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Version BA D

Observations Possible Causes Recommended Actions. Turquoise color

UsER manual for Watersens ph -REDOX

Standard Test Procedures Manual

Experimental Procedure

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

RECONSTITUTION AND ADMINISTRATION INSTRUCTIONS FOR HEALTHCARE PROFESSIONALS. Hereditary Angioedema

NEULOG OXYGEN LOGGER SENSOR GUIDE

CVC Insertion Simulator

QUIK-jet Micro-Injection System

Aerobic Respiration. Evaluation copy

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

ETT Olfactometer: Getting started guide 2013a. ETT Olfactometer quick start

SRI Model H2-40 Hydrogen Generator Operation and Maintenance Nov 2006

Dissolved Oxygen Meter. ino2. Instruction Manual. Serial No..

SOLUBILITY OF A SOLID IN WATER

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

no peaks missing peaks too small peaks increasing retention decreasing retention

Thank you for purchasing your new Empire Reloader B Sound-Activated 3-Speed Paintball Hopper!

Agilent 1290 Infinity Pump Head Maintenance

Commercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1

1.1 Equipment: substrate, wafer tweezers, metal targets 1.2 Personal Protective Equipment: nitrile gloves, safety glasses 1.

PREPARING GAS SAMPLES IN LARGE PLASTIC SYRINGES

Part II. Under Construction Station Instructions. Lab Station A - Blue Print: There is O 2 Here!

System Overview. TCD Detector temperature setpoint Regulator

RECOMBINATE. [Antihemophilic Factor (Recombinant)] (For intravenous use only)

Calcium Reactor. CalcFeeder PRO. User Manual 1.1a. Model. CalcFeeder AC1 PRO CalcFeeder AC2 PRO CalcFeeder AC3 PRO CalcFeeder AC4 PRO

WELLS JOHNSON HIGH VOLUME CANISTERS

Solvent System Walkthrough

SWS Option: Well Pressures. SWS Option: Stretch Correction (Corrected depth) SWS Option: MMD (Magnetic Marks Detection) ASEP Products

User s Manual. Autoclavable & UV r e s i s t a n t. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

Any laboratory is equipped with specific tools, equipment,

ShellPa. Standard Mechanical Cell Stretch System Model No: NNMS Serial #: User Manual

MAINTENANCE PROCEDURE FOR X 650

Chlorination Manual. I. Before going to the field. II. In the field. Sierra Leone

Instruction Manual. Pipe Friction Training Panel

Newborn Nursing Skills and ALS Simulator LF01400U Instruction Manual

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Gel Loading Practice MiniLab

Research Question How does the concentration of catalase affect the speed of the decomposition reaction of Hydrogen Peroxide into oxygen and water?

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

Transcription:

Lipodrop 2.0 device coating Compiled by K.V., K.Ž, J.R AIM: To selectively coat channels in order to make them hydrophobic (pre junction channels) or hydrophilic (post junction channels). REAGENTS USED: Table 1. List of reagents used in the experiment Name of reagent Cat. No. Lot number (if applicable) Polyvinyl alcohol (PVA) Table 2. List of tools used in the experiment Name of a tool Quantity 3 ml plastic syringe 2 1 ml glass syringe 1 Syringe needle 3 Tubing Tweezers Razor blade EXPERIMENT DESCRIPTION: This protocol aims to render the post-junction part of the device hydrophilic. This is done in order to prevent the lipid/octanol phase from wetting the inherently hydrophobic surface of the device. The hydrophilic treatment is achieved by injecting a 2.5% (wt/vol) 67 kda polyvinyl alcohol (PVA) solution through the OA channels and letting the PVA molecules adhere to the surface. It is critical for a successful liposome synthesis. Page 1 of 6

EXPERIMENT PROTOCOL: 1. Prior preparations a) PVA In order to prepare 2.5% (wt/vol) solution weigh 1.25g of PVA powder. Pour 50 ml of water into glass vial and put it on magnetic stirrer with heating function. Turn the magnetic stirrer on to vigorously mix the solution (600rpm) and raise the temperature to 80 C after that slowly pour PVA powder into the water (You should pour whole powder in 5 minutes Important: it is a crucial step to avoid PVA clumps in the solution). After you dissolve PVA in water, there should be no clumps left in it and the solution must be clear. Note: You should keep in mind that PVA dissolves slowly (more than 4 hours). In order to make precise concentration you should cover the vial while stirring the solution to avoid water evaporation. As an alternative to that preparation, I would suggest to dissolve it a little bit and then bring it to autoclave. It makes PVA to dissolve much faster. Note: Even though I followed more than one protocol, I did not manage to avoid small clumps. While it is really important to have dust-free and clumps-free solution, I tried to filter it with 400 nm filter, however, the solution is too viscous and it stuck in the filter. Later on, I strained it with 70µm cells strainer and it worked fine. Skip this step if you have enough of stored PVA. b) Microfluidic Devices Cut the tape on top of the PDMS with a razor blade between separate microfluidic devices for an easy access later. c) Syringes Prepare syringes for air (3 ml plastic syringes): secure the needles on the syringes and put the tubing on with the tweezers. Prepare a syringe for PVA: fill the syringe with PVA (use a pipette: gently touch filled pipette tip to the syringe opening and pull down the syringe grasp; make sure to avoid any bubbling) and put on the needle and then the tubing. Carefully press the syringe grasp up until devoid of air. Place the syringes vertically in appropriate places on the pumping device. Make sure to secure them firmly on with all of the holders (3 separate ones). See Fig. 1 for details. Note : the tubing should be appropriate length (enough to reach the channels but not wasteful). Note : check the air syringes before every coating procedure: the plunger of the syringe should be pulled back. Page 2 of 6

Fig 1. Syringe placement setup Red numbers indicate where the syringes should be secured, while white numbers mark appropriate screws for fastening the syringes in place. d) Connecting the DropGen portable microfluidics station a) Turn on the station by plugging it to the electrical socket. Simultaneously, turn on the computer and connect to DropGen Wi-Fi. Then visit the website: 192.168.1.100 b) For this experiment a default 3 syringe interface can be used. There is an option to name the pumps by selecting Pump settings in the Settings section found on the same page. c) Camera view window should appear on the left part of the website (if not, restart the device or the webpage, or both). d) To focus the camera, use the silver knob on the pumping device. For quick adjustment press Auto adjust on the webpage right below the camera view. It is possible to adjust illumination, exposure and FPS manually. e) Pumping velocities can be regulated on the right panel of the website. e) Syringe priming To fill the tubes with material and make sure that syringes are firmly placed on the device press purge until you see the material (PVA) visibly at the end of the tube. (this should be done to air syringes as well). Page 3 of 6

Before work, make sure that the portable station is clean from any dust as it potentially could clog the channels of devices. Prepare wipes for collecting the waste (they should be right under the waste tubing). 2. Microfluidic device scheme pre-junction channels post-junction channels Fig. 2. Scheme of Lipodrop 2.0 microfluidic device. Green arrows indicate different inlets while blue arrow marks the outlet. 3. The coating procedure Important: The coating procedure is only a rough guideline for the coating process. One should consider that each microfluidic device is slightly different (channel height, proportions, etc.), some of which might have impurities or defects that would require adjustments to the suggested velocities. Keep in mind that the process is dynamic and requires continuous attention. One of the most important parts of the process is achieving a correct and stable meniscus at the junction (See Fig.3 )! a) Put the tubing connected to the air syringes into Inlet 1 and Inlet 2. Set the flow rates to 1000 µl/h and turn the appropriate pumps on. Wait half a minute before putting in the PVA tubing. Note : air should be the first one turned on and the last one turned off. b) Put in the waste tubing to the Outlet. c) Put in the PVA tubing to the remaining hole. Wait at least 1 minute before turning PVA on. d) Turn the PVA on with the flow rate between 50 µl/h and 150 µl/h and wait for the PVA to appear. Once it flows into the inlet, turn it off ASAP and increase the flow rates of air to 1500 µl/h. e) Observe the situation at the junction. If everything is correct, the PVA and air should meet at the junction without PVA entering pre-junction channels. There is a chance that it won t reach the junction while turned off. In that case turn on the PVA (lower than 50 µl/h) and gradually decrease the air velocity. Page 4 of 6

Note: If PVA does infiltrate pre-junction channels, discard the device and start over. f) After a couple of tens of seconds (needed for the pressure to settle) set the PVA to 50 µl/h and turn it on (if turned on before, increase it up to 50 µl/h). g) The aim is to get a junction looking like Fig. 3 To reach it, adjust flow rates of air and PVA. Usually, once PVA has travelled to the junction and closed it, there is sufficient pressure in the pre-junction channels to deflect the air, therefore it can be gradually decreased according to the situation. (It could even go down to 100 µl/h in some cases). At the same time PVA is increased (up to 600 µl/h in some cases). Note: some air bubbles leaving the pre-junction channels h) Keep a steady meniscus at the junction for 4-6 minutes. i) Take out the PVA tubing (while on) and then turn it off. Note: before taking out the tube, make sure that the post-junction channel is devoid of bubbles, as it creates unwanted bumps while PVA dries. f) Increase air flow up to 1500 µl/h to dry out the remains of PVA. g) Turn off remaining pumps and take out the tubing. h) Before putting back on the tape, blow out any remains of PVA with a syringe (without any needles). If the coating was correct, mark it as such with a marker. Fig. 3. A correct meniscus at the junction during the coating process. Grey arrows indicate the direction of the PVA while blue arrows indicate direction of air. Meniscus is observed at the junction. Page 5 of 6

ADDITIONAL OBSERVATIONS AND IDEAS: Possible mistakes & troubleshooting Always be observing the PVA inlet during the injection as it can appear quicker than anticipated. Make sure to check the correct arrangement of the microfluidic device before putting in the tubing. Check for the defects before every measurement to avoid wasting time and reagents on a defective device. Defects might include dust particles, closed channels, detached PDMS, discontinuous channels etc. If the PVA is not appearing, check if the tubing is not leaking or if it is not primed correctly (i.e. with bubbles). In that case change the tubing or purge the PVA, accordingly. Page 6 of 6