FITNESS, SAFETY & MEDICAL SUPPLIES

Similar documents
POP UP ANCHOR. Part Number Spectrum Lane ~ Missoula MT ~

SCOUT DECK ANCHOR 3 1/4" BONDING SCREW

Global Lift ADA Compliance

ROCKSOLID SINGLE POST ANCHOR

LEGACY II TM STARTING PLATFORMS

ROCKSOLID DUAL POST ANCHOR

INSTALLATION INSTRUCTIONS AT-SERIES ANCHOR ASSEMBLY PART NUMBER: F-04CAJP 450 LB. [204kg] MAXIMUM CAPACITY (PRO POOL LIFT)

DELUXE LOW PROFILE 18 & 30 STARTING PLATFORMS

S110 Steel Level Panel Installation Instructions

42 inch Mower for TimeCutter Z Riding Mowers. Note: Determine the left and right sides of the machine from the normal operating position.

Stand-N-Fish FULL DETAIL INSTALLATION INSTRUCTIONS

CHEMICAL. Straight cut rod is provided in the materials listed below and includes nuts / washers.

BALL STOP INSTALLTION GUIDE

-- SGP (NOVA TEAM SQUARE)

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

Spectrum AquaLight (SAL ) Color Underwater Light Owner s Manual

Portable Soccer Goal Safety Program

TOWER INSTALLATION MANUAL For A.R.E. Guyed Pipe Towers Short Towers 43, 64 and 85 feet tall

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

ASSEMBLY INSTRUCTIONS

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Installing a Christie One Mount/Christie One Mount Plus

ada compliance swimming pool Compliance guide

Drop-In Internally Threaded Anchor (DIAB) Mechanical Anchors. Key features. Material: Carbon steel. Coating: Zinc plated

KERSPLASH POOL CLIMBING WALL INSTALLATION INSTRUCTIONS

Retractable Security Cover for a Swim Spa

Parts List. Description. Additional Considerations. Installation Instructions. Dual/Elite Hydraulic Treadmill Kit (supplied by EPI)

Crystal Spring Feeder Protocols

PORTABLE LIGHTNING MAST PROTECTION PLP SERIES INSTRUCTION MANUAL

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

Big Ride ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * *

mullen shower base LIFE TIME Suitable for: ALL Floor Types Floor Coverings V Vinyl Wood Flooring Concrete Slab C Ceramic Tiles

Installation Manual. Version 12-10

BACKSTROKE START DEVICE

Bollard Light Installation Guidelines

BENEFITS OF TIGHTER ANCHORING SYSTEMS

QUALITY ALUMINUM BOAT LIFTS, INC. INSTRUCTIONS. Dominator Lake Lift

LoneStar Fiberglass Pools. Do-It-Yourself. Installation Manual

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Final Assembly Instructions Bikes with 16 Wheel Size

Pressure Dump Valve Service Kit for Series 3000 Units

ASSEMBLY MANUAL HOBIE CATSY

Safety. Lawn Striper Kit CAUTION CAUTION. Operator Manual. Read all of the instructions in this manual prior to

Troyer s Gourd Rack 8 unit F R H O P

Universal Anchoring Adapter For Mercedes

Traditional Basketball Set. Assembly & Installation Instructions

PERMA-CYL 230/450/1000/1500/2000. Installation Manual Manual # Revision B

ADA Access Standards for Swimming Pools, Wading Pools, and Spas

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

NAVIGATOR PROP BUILDING INSTRUCTIONS & PHOTOS

Constitution Instructions

Marine 6-Boat Free-Standing Racks SKU: Updated November 2011

CO V E R S TA R AU TO MAT I C S A F E T Y CO V E R INSTALLATION GUIDE

TECHNICAL DATA BROCHURE - ZTR 428 & 429

MODEL TRIPEX PULLEY SYSTEM

3/4 SafeClaw Anchorage Connectors

Utility Anchor System

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Booster Pump PB4-60 Replacement Kits

Perched Box Caisson Overview. January 2014

PRODUCT CARD WALL MOUNTED FIXED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,00 TO 2,25 M

A-FRAME RESIN IN & OUT FLIP UP LADDER

PHOENIX, ARIZONA USA

Dinghy Racers Parts List

GRAVITY BIKE RACK ASSEMBLY & OPERATING INSTRUCTIONS

BARRIER OFFSET 0" A 6" 6" A 12" 12" A 26" A 26" 3A OR 4A L OR S * ** L OR S L OR S

PRODUCT CARD WALL MOUNTED SIDE FOLDED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,2 TO 2,45 M

AQUATREND. AQUATREND Water Workout Station. Owner 's Manual

Pressure Dump Valve Service Kit for Series 2300 Units

2010 STANDARD SPECIFICATIONS STANDARD DRAWINGS

INSTALLATION INSTRUCTIONS: SCTB1600

Instant Garage 20' x 12' 3" x 8' 3"

CARES Technical Approval Report TA1-B & C 5059

TurboDraft Fire Eductor

Agilent 1220 Infinity II LC Mobile Upgrade Kit

CONFER IN-GROUND CURVE STEP / IN-GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL

Made in the USA. For Fall Protection Only. SafeLok Part Description

HOW TO : ASSEMBLY & INSTALLATION

1 & 3 Meter Tower CAT 1M 203R RIGHT MOUNT CAT 3M 203R CAT 1M 203L LEFT MOUNT CAT 3M 203L CAT 1M 203D DUAL MOUNT CAT 3M 203D

1/2 METER FLYTE-DECK II FIBERGLASS STAND (6' BOARD) (8' BOARD) (10' BOARD)

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

SPOOLER INSTRUCTIONS. STEP 12 If you are going to paint your posts, that should be done at this time.

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

INSTRUCTIONS 360 Y-DROP HAGIE STS 2015

Reproduction. Not for. Installation Instructions. Installation Instructions. Part No Installation. 32/36 Bagger 32/36 Kit WARNING

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 8 RECREATION FACILITIES

A N C H O R T A B S N O R T H W E S T ANCHOR TAB VF. Patented. User Instructions

1.0 - OPENING AND CLOSING THE DOOR

Carving a Custom Seat

MODEL / SINGLE and DUPLEX PULLEY SYSTEMS

PoolLock Easy Pool Cover

INSTALLING THE PROWLER 13 RUDDER

1 SafeClaw Anchorage Connectors

the square steel tube posts, municipalities can use either the U-channel or square steel tube post signs on locally owned roads.

TECHNICAL DATA ZTR Model 312

Assembly Guide ST200 FUNCTIONAL TRAINER

MSA Confined Space Entry Equipment

Tapped Hole (.375) Tapped hole 15 (.594) (.391±.004) Frame 19±0.2 (.750±.008) 12.7±0.2 (.500±.008) 19±0.2 (.750±.008) R S 4 x Ø 5.4 (.

INSTRUCTIONS. for installing ALDON Two-Way LOCOMOTIVE Hinged Derail on wooden ties. For 4-Axle and 6-Axle Locomotives and all Freight Cars

Transcription:

COMMERCIAL SERIES LIFTS TABLE OF CONTENTS 1. TRI-Point Anchor System 2. TRI-Point Paver Instruction Anchor Method 3. TRI-Point Retro-Fit Anchor System 4. TRI-Point Drop In Anchor System 5. Commercial Series Portable Kit active forever.com FITNESS, SAFETY & MEDICAL SUPPLIES

COMMERCIAL SERIES LIFTS C-375/C-450 TRI-POINT ANCHORING SYSTEM New Construction or Saw Cut INSTALLATION MANUAL Patent Pending

COMMERCIAL SERIES C-375/C-450 TRI-POINT ANCHORING SYSTEM INSTALLATION Patent Pending PARTS LIST 1 - Anchor Plate with bonding Lug & bolt 3-5/8 Stainless Steel Bolts 3-6 Anchoring Rods 3 Plastic Caps

ANCHORING PLATE, ANCHORS & BONDING LUG 5/8 s Bolts

ADA GUIDELINES FOR POOL LIFT PLACEMENT Pool Lift Location. Pool lifts shall be located where the water level does not exceed 48 inches (1220 mm). Seat Location. In the raised position, the centerline of the seat shall be located over the deck and 16 inches (405 mm) minimum from the edge of the pool. The deck surface between the centerline of the seat and the pool edge shall have a slope not steeper than 1:48. Clear Deck Space. On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. The space shall be 36 inches (915 mm) wide minimum and shall extend forward 48 inches (1220 mm) minimum from a line located 12 inches (305 mm) behind the rear edge of the seat. The clear deck space shall have a slope not steeper than 1:48. Submerged Depth. The lift shall be designed so that the seat will submerge to a water depth of 18 inches (455 mm) minimum below the stationary water level.

COMMERCIAL SERIES C-375/C-450 TRI POINT ANCHORING SYSTEM Water Pool Wall Front of Anchor Plate can be placed 11 to 16 from water s edge depending on you application 3 Overview Anchor Plate 3 3 Section Detail 6 Threaded Anchor s Concrete Cold Pin 6 Bonding Lug Cold Pin Concrete COMPACT SAND 5/8 Bolts Optimal placement of the anchor system is 13 from the front of the anchor plate to water s edge. Attach copper wire to the bonding lug and then to your bonding grid Cold Pin s should be ½ rebar 6 to 8 long NOTE: Make sure your anchor plate is level and square with your pool s edge.

Step 1: Determine the location for installation (Make sure all ADA requirements are met). ***NOTE: The installation of Global Lift Corp s anchor system s are a guideline of minimum requirements. In some states or municipalities they may require additional steps due to their local codes or ordinances.*** Step 2: Make sure that all the parts are present (Refer to the parts list) 1 - Anchor Plate with Bonding Lug & bolt 3-5/8 Stainless Steel Bolts 3-6 Anchors Step 3: At the determined location for installation, chalk out a 3 X 3 area prior to cutting out the concrete. (Refer to overview, the front of the Anchor Plate must be 11 to 16 from the water s edge and 6 deep). New Construction, the concrete must be 6 deep with a ½ reinforcing rod, minimum of an 18 grid. NOTE: Make sure all local codes and ordinances are met. Step 4: Once the 3 X 3 area is cut out, make sure you drill in the inner wall of all 4 sides of the area (refer to the section detail) for the purpose of cold pinning the new concrete to the old concrete. Use 1/2 rebar, 6 to 8 in length. Step 5: Attach the 3 6 threaded anchor s with the 5/8 s bolts (included) to the Anchor Plate and tighten down.

Step 6: Place the Anchor Plate in the area, make sure that the front of the Anchor Plate is 11 to 16 from the water s edge and that the decal s arrow on the anchor plate is pointing to the water s edge (refer to overview). A key element is to make sure that the Anchor Plate is level and square with the pool so that your Commercial Series Lift sits properly on the deck. Step 7: Bonding the unit The bonding lug is included with the Anchor plate (furthest point from the pool wall on the Anchor Plate) locate the bonding lug, connect the bonding lug to the bonding grid. NOTE: Make sure all local codes and ordinances are met. Step 8: Pour in your concrete, (make sure you cover the holes in the 3 threaded anchor s so you don t get concrete in the threads) minimum of 4,000 psi with reinforcing rod. Also make sure that the tops of the threaded anchors are flush with the deck. Before you install your lift make sure you let the concrete set up for 48 hours. Step 9: After the concrete has set for 48 hours, now it s time to install your lift. Place your Commercial Series Lift over the anchor holes, screw in the Anchor bolts that are included and tighten down securely. Once you have completed the installation, please refer to User s Manual for a safe operation. www.activeforever.com