MANUAL. Instructions for use

Similar documents
CRYOS MANUAL. User instructions

OptonPro. High-power laser up to 7000 mw. Laser therapy natural healing with the power of light

CRYOS CARD MANUAL. User instructions

User manual. MNPG 102 Rev. 04 Edition 04/02/16. Pressotherapy model. Power-Q1000 Premium

User manual. PG89 Rev 01 Editi Pressotherapy model. LymphoPress 4

77-I0PN230 Rev. A. Model 1030 User Manual

User manual. PG132 Rev01 Editi Compressive Limbs Therapy System DVT-7700

DYNAMIC COMPRESSION THERAPY

MAGNETRON 40HS / 40DC / 40TC [Clarification- HS =home system/ DC= doctors Clinic / TC= Therapy Center]

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

User Manual PTW-DensiX. D / Di/Zi

LYMPHA PRESS MANUFACTURED BY MEGO AFEK IMPORTED BY LYMPHA PRESS USA, Ltd. USERS MANUAL LYMPHA PRESS MODEL 201-M

A4s Operation Manual

F-330 Instruction manual. Magic Glove Bio Skin Smoother High Frequency Ultrasound Galvanic

OPERATING INSTRUCTIONS PSORIAMED. Revision: 1.0-D GB

POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic

The Univentor 1250 Anaesthesia Unit

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

BTL-6000 LYMPHASTIM BTL PRESSO-THERAPY SYSTEM FOR MEDICAL AND AESTHETIC PRACTICES

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Module No GETTING ACQUAINTED GENERAL GUIDE TIMEKEEPING

Theatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)

USER MANUAL. MNPG69-02 Edition 08/07/13. Magnetotherapy model MAG700. I.A.C.E.R. Srl.

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a

Use this key to determine which sections of this Product Manual apply to your job.

LUNA V. User Manual. Warning

Roller AC Servo System

Instruction Manual for Configura Cushionair Portable Pump

Vevazz. Operation Manual. Vevazz, LLC Rancho California Road. Suite Temecula, CA Phone: (773) Fax: (888)

USER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d

Introducing the Body Back Buddy TM

Air Plus User Manual

Touch Screen Guide. OG-1500 and OG Part # T011

Oxygen Dialflow Meter. Instructions for Use

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Oxygen Dialflow Meter. Instructions for Use

USER MANUAL LTH-255A Hand Piece

EN-MOTION TREADMILL. EN-Motion: the ultimate PHYSIO treadmill

Instructions for Use

CJMJ.DPNQBDU. Instruction for use. Neonatal phototherapy device. BILI-COMPACT WY 1816/ Year of manufacture D2017_00

Med Aire Alternating Pressure Pump and Pad System

Ultrasound Dose Calculations

HZ-300 HAZER MACHINE USER MANUAL. Congratulations on the purchase of your new ANTARI HZ-300 Haze Machine.

TABLE OF CONTENTS. Introduction. Specifications. Contraindications. Limitations. Safety Precautions. Safety Instruction. Advantages.

Company building TOTAL SOLUTION OF AIR COMPRESSION THERAPY SYSTEM. New second factory. Main office & Factory Stories house

INSTRUCTIONS FOR USE PHYACTION PERFORMA

DENAS Reflexo (p.21 40)

Dräger X-act 5000 Automatic Dräger Tube Pump

INSTRUCTION MANUAL. SoundCare Plus Pain Relief Device Operating instructions Medical device for pain treatment based on ultrasound

Electrical operating instructions

Qi Litre Ultrasonic Cleaner

New Farma Press 2 Pressotherapy for wellbeing. User Manual

CRANE WITH WINCH USE AND MAINTENANCE MANUAL. Code Rev. Release MD /03

DENAS-CARDIO 3rd generation

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

OPERATOR s MANUAL AHCON PCI 3000

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

Domiciliary Oxygen Switch. Instructions for Use

Operating instructions Electrical switching facility pco

Instruction Manual Recovery Station

TWIST-IN STEPPER SF-S0636 USER MANUAL

USER MANUAL. JET TST and JET TST S.

Introducing the Body Back Buddy TM

SkillGuide. User Guide. English

USER MANUAL. MNPG69-06 Edition 11/09/15. Magnetotherapy model MAG700. I.A.C.E.R. Srl.

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Pressure switch KP-E. Data sheet

Electrical Safety in Hospitals

Ultima. X Series Gas Monitor

User Guide Antidecubitus systems EURO BASIC

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

Instructions for Use

Manual Weighingblock VB2 series and Uniscale

Manual winch MANISTOR 100 and 200

A high flying simplicity DUAL SOFT BAG INJECTION SYSTEM

OPERATION MANUAL NTF-15

AA GWR Water Retention Meter for Accurate Measurement of Water Retention

VERTICAL AIR COMPRESSORS

New AQF Filter Polymer Filtration System

In Vessel Composter Installation & Commissioning Manual

Precioso series 2. Prevention and therapy for everybody, everyday NURSING-CARE HEALTHCARE

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

4 ANGLE GRINDER MODEL NO: CAT 52 PART

AIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS

User Manual. Nitrogen generator N2 LCMS 1

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Comfortmax Thermax Hot/Cold Water Circulation System. Instructions for Use

GENERAL SAFETY INSTRUCTION GSI-M-2 STANDARD PRESSURE EQUIPMENT

ekom Compressor for Medical Air Sonata with Ekom

Technical Data Sheet MF010-O-LC

WARNING FOR YOUR SAFETY

DECLARATION OF CE CONFORMITY DECLARATION OF CE CONFORMITY

6833_INSTRUCTIONS MANUAL DIGITAL WIRST BLOOD PRESSURE

CCT-7320/ROC-2313 Reverse Osmosis Controller

OPERATORS MANUAL AHCON PCI 1000

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Transcription:

α LASER MANUAL Instructions for use New Age Italia srl Via De Brozzi, 3-48022 Lugo (RA) Tel.:+39-0545.32019 - Telefax: +39-0545.369028 Web: www.newageitalia.it - E-mail: info@newageitalia.it This document is property of New Age Italia srl. All rights are reserved. Any copy or reproduction of it through any means, including total or partial photocopy of the contents, is prohibited without the written consent of New Age Italia srl.

Rev. 00 of 15/03/11 2/20

INDEX Cap.1 PRESENTATION... 5 1.1 Biological effects of α LASER... 6 1.2 Who is α LASER for?... 7 1.3 Fields of application... 7 1.4 Contraindications... 7 Cap.2 OPERATION... 8 2.1 Turning device on... 9 2.2 Selection of program type... 9 2.2.1 - Free manual mode... 9 2.2.2 - Reset program mode... 9 2.2.3 - Personal program mode... 9 2.3 Start of stimulation... 10 2.4 Setting time and intensity of emission... 10 2.5 Interrupt / end therapy... 10 2.6 Turning device off... 10 2.7 Configuration... 10 Cap.3 PRE-SET PROGRAMS... 11 Cap.4 FREE PROGRAMS... 13 4.1 Setting a new program... 13 4.2 Use and modification of a personal program... 13 Cap.5 APPLICATIONS... 14 5.1 Therapy sessions... 14 5.2 Adjusting emission power output... 14 5.3 Posture to be kept during the sessions... 14 Cap.6 SYMBOLS... 15 Cap.7 MAINTENANCE... 16 7.1 Knob... 16 7.2 Device... 16 7.3 Immediate maintenance:... 16 Cap.8 WARNINGS... 17 Cap.9 TECHNICAL FEATURES... 18 9.1 Power supply... 18 9.2 Output features... 18 9.3 Other features... 18 Rev. 00 of 15/03/11 3/20

Cap.10 BASIC SUPPLY AND ACCESSORIES... 19 10.1 Basic supply... 19 10.2 Accessories and consumption material... 19 ATTENTION: READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE. IT IS RECOMMENDED TO SEEK THE ADVICE OF MEDICAL PERSONNEL FOR THE THERAPEUTIC INDICATIONS REQUIRED. Rev. 00 of 15/03/11 4/20

Cap.1 PRESENTATION In 2010 New Age Italia enters the world of LASER therapy with a new aim. To have the full control of the parameters constituting LASER therapy. In the LASER New Age devices it is possible to set power, time, frequency from 100Hz to 20KHz, duty cycle 20%-100% (continuous). The absolute novelty of the New Age machines is in the possibility of performing therapies simultaneously using 3 LASERS with different wave lengths: 808 nm 980 nm 1064 nm This unique feature enables treating different tissues and depth at the same time, concretely limiting the treatment times. The colour display with touch-screen technology and the rotary encoder provided with push button, enable an easy and immediate approach to using the machine. The real time viewing on display of the transmitted energy, total energy and average transmitted power, guarantee full therapy control, thus supplying the operator with the best instruments. New Age also makes available its experience in the physiotherapy field through the various programs that each appliance owns; this enables the operator to be operational and efficient, right from the first applications, obtaining the best results in the least possible time. The high powers of the LASER New Age modules enabling to quickly reach the therapeutical energy dosing, thus reducing the time of each therapeutical session. To obtain spot LASER with different diameter, the classical method envisions the use of various length interchangeable spacers, positioned between patient and knob, differently the R&D New Age department has developed an innovative knob provided with a lens system able to focus and defocus the LASER ray from a minimum spot of 8 mm to a maximum of 20 mm, simply by turning the ring nut present on the knob, thus eliminating interchangeable components and enabling a more accurate regulation of the spot. New Age only uses first choice materials to manufacture the appliances, such to guarantee maximum efficiency and reliability to the customer. All this translates in the utmost decision-making freedom for the operator and, therefore, the best results in shorter times. Rev. 00 of 12.06.09 5/20

1. 1 B i o l o g i c a l e f f e c t s o f α L A S E R The LASER radiation, penetrating the tissues, causes photochemical reactions at cellular level that induce different effects. Mitochondrial Stimulation: one of the most therapeutical effects of the LASER, consists in stimulating cellular mitochondrion. Mitochondrions are the energy generators of each cell, responsible for the production of ATP (adenosine triphosphate) that constitutes energy reserve of the cell. The ATP is produced by ADP (adenosine diphosphate) plus Pi (phosphate) plus E (energy) therefore, ATP=ADP+P+E. The more ATP is present in a cell, the healthier and more energetic it is. It has been proven that cells stimulated by LASER light increase their production of ATP and, therefore, if inflammatory or degenerative processes are in progress, they have sufficient energy to quickly recover the optimal health state. Activation of the microcirculation: One of the effects deriving from using the high power LASER, is the distinct vasoactive effect on the microcirculation. The activation of the microcirculation entails greater oxygenation and nutritional input, as well as greater drainage of the catabolite from the tissues. Activation of the lymphatic peristalsis: The LASER light accelerates the lymphatic peristalsis, which facilitates absorption of interstitial liquids and the reduction of oedemas of phlogistic and post-traumatic origin. Hyperpolarisation of the membranes of the nervous fibres: Experimental studies have proven that the therapeutical LASERS determine the hyperpolarisation of the membranes of the nervous fibres. This effect appears to be linked to the closing of the membrane channels for potassium, due to amendments of the superficial lipoprotein. The hyperpolarisation causes the elevation of the excitement threshold of the pain receivers. Transforming prostaglandin in prostacyclin: The therapeutical LASERS stimulate the forming of prostaglandin in PG12 prostacyclin, which have antiphlogistic, anti-edemigenous and analgetic action. Rev. 00 of 12.06.09 6/20

1. 2 W h o i s α L A S E R f o r? The medical field (especially physiotherapy) is the sector most suited for α LASER to fully express its potentialities. 1. 3 F i e l d s o f a p p l i c a t i o n The most common pathologies treated with LASER therapy are those of the locomotory apparatus and of the derma. In particular, the LASER is successfully used for treating: Arthralgias of various nature, rheumatic and degenerative (inflammatory and degenerative arthropathy, epicondylitis, knee pain with and without shedding, myositis, polyarthritis, arthritis, arthrosis, sciatica, lumbago). General traumatology articular sprains, tendonitis, tenosynovitis, muscle strains, bruises, bursitis, enthesitis, torn muscles, pathologies of overload, muscular injuries and tendon, Torn muscles and tendon, Muscular bruises post surgery or post forced inactivity motor rehabilitation Dermatology psoriasis wound healing, bedsores oedemas, arteriopathy; Circulatory deficit We recommend consulting a doctor for the diagnosis and control of the therapy. 1. 4 C o n t r a i n d i c a t i o n s Magnetic fields have some contraindications in common with other physical equipment which acts by means of endogenous heat production: Neoplasms (tumours); sensitivity alteration. area with acute haemorrhage photosensitivity Rev. 00 of 12.06.09 7/20

Cap.2 OPERATION 6-Stop button 1-Touch screen display 2- Knob + push button 5- Emergency Button 3-safety key 4- Optical fibre output NOTE: check the contraindications and follow indications carefully before applying LASER therapy. Rev. 00 of 12.06.09 8/20

2. 1 T u r n i n g d e v i c e o n To activate α LASER, switch-on the rear switch, check that the emergency button is released, turn the switch-on key. An initial screen appears on the display presenting the device including: the name of the appliance version, the START key and the CONFIGURE key. 2. 2 S e l e c t i o n o f p r o g r a m t y p e α LASER can operate in 3 different modes: 1- Free manual mode 2- Pre-set program mode 3- Personal program mode 2.2.1 - Free manual mode Press START on the initial screen to access the manual mode area. In this area, by TURNING THE KNOB you can vary the value of the parameter selected, whereas by PRESSING THE KNOB you pass from one parameter to the next. The concerned parameters are: type of emitted wave, supplied power, therapy duration, duty cycle of the generated wave. 2.2.2 - Reset program mode Press START on the initial screen (touch screen) to access the work area. Then press PROGRAMS (on touch screen) to enter the Menu for choosing specific protocols where first of all the therapy to be used is selected, by turning the encoder and then pressing ENTER (touch screen) or else PRESSING THE KNOB to confirm the program selected. 2.2.3 - Personal program mode The custom-made programs are at the bottom of the list of pre-set programs. Press START on the initial screen (touch screen) to access the work area. Then press PROGRAMS (on touch screen) to enter the Menu for choosing specific protocols. At the bottom of the list first of all the therapy to be used is selected, by turning the encoder and then pressing ENTER (touch screen) or else PRESSING THE KNOB to confirm the program selected. Rev. 00 of 12.06.09 9/20

2. 3 S t a r t o f s t i m u l a t i o n Once selected a pre-set program or after having regulated the parameters in the manual functioning area, the display shows START. Press the relative START to begin the therapy. After having pressed START, the device places itself a stand-by state; during this phase the machine will wait 30 seconds for the pedal arming the LASER to be pressed. Having pressed the pedal once passes to LASER ARMED state, in this situation the LASER emits only the red pointing light. Pressing the pedal a second time passes to EMISSION state where the therapeutical LASER also is emitted. 2. 4 S e t t i n g t i m e a n d i n t e n s i t y o f e m i s s i o n The duration of the therapy and the intensity can be set at any time by rotating the encoder. PRESS THE KNOB repeatedly to pass from the intensity parameter to the time parameter and vice versa. The minimum density increase is of 1% and the maximum settable intensity is 100%, the minimum time increase is of 1 minute. 2. 5 I n t e r r u p t / e n d t h e r a p y Treatment emission is interrupted automatically when the Timer reaches 0 and an acoustic signal is heard. If you wish to interrupt treatment before the end, press the pedal or STOP (on touch screen) (on the front panel). After the pause, to restart treatment press the pedal twice. 2. 6 T u r n i n g d e v i c e o f f In order to turn the device off, turn the key or press the switch on the back of the device. 2. 7 C o n f i g u r a t i o n The LASER devices can be set-up according to personal requirements. Press CONFIGURE (on touch screen) to access the setting area. This section displays the following entries: 1) language: Italian, English, French, German, Spanish, Portuguese 2) brightness of display: from 0 to 10 3) volume of buzzer: from 0 to 10 Rev. 00 of 12.06.09 10/20

4) Operator time out: time the operator has to press the pedal after the start key has been pressed. 5) unblocking code: to enter before turning the device on the first time 6) Maximum power output: indicates the maximum power output of the device and it s given by the sum of the average powers of the waveforms delivered. Cap.3 PRE-SET PROGRAMS LASER therapy has long been used for the treatment of some pathologies which can benefit from the effects of electromagnetic fields: chronic pathologies, articular problems, oedemas, etc. This chapter lists the programs pre-set inside the device. α LASER has 40 different pre-set programs, as well as the possibility of memorising up to 20 free protocols. N. NAME 1 Hands ARTHRITIS 2 Knee ARTHRITIS 3 Ankle ARTHRITIS 4 Elbow ARTHRITIS 5 Wrist ARTHRITIS 6 Shoulder ARTHRITIS 7 Hip ARTHRITIS 8 TRIGEMINAL NERVE 9 INJURY OUTLINE 10 INJURED AREA 11 1 cm deep FRACTURE 12 2 cm deep FRACTURE 13 3 cm deep FRACTURE 14 4 cm deep FRACTURE 15 5 cm deep FRACTURE 16 ARTHROSIS 17 DISLOCATIONS 18 SPRAINS 19 BRUISES Rev. 00 of 12.06.09 11/20

20 TEARS 21 MUSCULAR ATROPHY 22 NEURALGIA 23 TENNIS ELBOW 24 TENDINOPATHY 25 FRONTAL HEADACHE 26 POST SURGERY RESULTS 27 BURNS OUTLINE 28 BURNT AREA 29 VARICOSE ULCERS OUTLINE 30 VARICOSE ULCER AREA 31 SORE OUTLINE 32 SORE AREA 33 PAINFUL LYMPH NODES 34 FACIAL PARALYSIS 35 ACNE 36 OEDEMAS 37 LEG BONE REGENERATION 38 ARM BONE REGENERATION 39 HAND/FOOT BONE REGENERATION 40 ULCERS Rev. 00 of 12.06.09 12/20

Cap.4 FREE PROGRAMS 4. 1 S e t t i n g a n e w p r o g r a m From the program section, press NEW (on touch screen) to enter the Free Program menu. By rotating the encoder you can choose which of the 20 custom-made programs available you wish to set. Press CHANGE (on touch screen) to enter the section for setting the name. TURN THE KNOB to change the letter and PRESS THE KNOB to move the letter selection cursor. Once you have chosen the name, pass on to the parameter setting phase. Press PARAMETERS (on touch screen) to move the cursor in the work phase setting section. In this zone, ROTATE THE KNOB to set the parameter value and PRESS THE KNOB to pass from one parameter to another. With α LASER it is possible to set up to 3 consecutive work phases, where in each it is possible to use: different wave lengths, different intensity values and timing. To move from one phase to another, scroll all parameters of a phase, after passing the last parameter of a phase, the first parameter of the successive phase appears. When the parameters have been set, the name of the program can be modified once again. Press NAME (on touch screen), save the program by pressing SAVE (on touch screen) or else exit without saving by pressing EXIT (on touch screen). 4. 2 U s e a n d m o d i f i c a t i o n o f a p e r s o n a l p r o g r a m To amend carry out the instructions in paragraph 4.1 Rev. 00 of 12.06.09 13/20

Cap.5 APPLICATIONS 5. 1 T h e r a p y s e s s i o n s Apply the LASER therapy according to medical prescriptions. Applications are done every other day or 2-3 days. Use the most suitable program for the patient until the ailment disappears or considerably decreases. 5. 2 A d j u s t i n g e m i s s i o n p o w e r o u t p u t Intensity adjustment is a main component for the good result of the therapy. It differs based on the type of program being used, the duration of the application and the characteristics of the patient. The intensity can be changed during the program to increase its affects. It can also be decreased in case of overheating or if pain is felt. The device is endowed with a special function that allows to have safer treatments: it s the Maximum power output, you can find it in the configuration page, and it allows to set the maximum power output of the device. Consequently during work phase the sum of the power of the different sources cannot exceed the value set during configuration, therefore avoiding dangerous power levels during treatment. If inadvertently the operator tries to set higher values, the device automatically limits itself. The device shows that the threshold has been passed in two ways: if the operator is adjusting the duty cycle, the device limits the power bar and it get red; if the operator is adjusting the bar power, then the device limits the duty cycle value showing it as red. NOTE: if the intensity set or its regulation cause excessive heating or pain in the treated zone, the intensity of the stimulation must be reduced immediately or the application must be stopped. 5. 3 P o s t u r e t o b e k e p t d u r i n g t h e s e s s i o n s The ideal posture is to be relaxed, lying on ones back or facedown depending on the zone of application. This position must be maintained during the entire session to facilitate the effects produced by the laser beam, especially the increased the blood flow due to dilation of the blood vessels, During treatment, the knob must maintain a perpendicular position to the treated area. Rev. 00 of 12.06.09 14/20

POWER SUPPLY α LASER must be powered by the electrical mains Precautions for use (1) Do not short-circuit the terminals. (2) Do not set off sparks or flames. Cap.6 SYMBOLS BF DEVICE ATTENTION, CONSULT THE ATTACHED DOCUMENTATION THIS DEVICE IS MARKED CE IN COMPLIANCE WITH 0476 DIRECTIVE EEC 93/42. DO NOT DISPOSE OF IN COMMON WASTE Rev. 00 of 12.06.09 15/20

Cap.7 MAINTENANCE 7. 1 K n o b The connection cable must be periodically checked for cracks, possible cause of dispersion. 7. 2 D e v i c e Use a cloth moistened in water and alcohol to clean the device. Do not use liquids at all since there is not protection against their entrance (IP20). 7. 3 I m m e d i a t e ma i n t e n a n c e : Immediate maintenance at New Age Italia or by authorised personnel if: the device has been subject to external mechanical stress (e.g.. serious drops); the device has been overheated excessively (e.g. if left near intense heat sources; you doubt that liquids may have penetrated inside; the power supply, the cover or other parts are damaged, broken or missing; it appears that the features of the device have been changed. for safety purposes, do not operate with accessories (e.g. knobs and power supply) other than those included in the basic supply. The frequency of maintenance, functional checkups and inspection for compliance with safety standards EN60601-1 for medical devices carried out with secur-tester is yearly. The useful life span of the instrument is guaranteed by the company only if maintenance is carried out regularly. N. B.: have inspections carried out only by New Age Italia. The device can be sent directly to company assistance workshops or delivered to the dealer where the device was purchased. Assistance centre: New Age Italia srl - Via De Brozzi, 3-48022 Lugo (RA) Tel.:+39-0545.32019 - Telefax: +39-0545.369028 Web: www.newageitalia.it - E-mail: info@newageitalia.it Rev. 00 of 12.06.09 16/20

Cap.8 WARNINGS Pay special attention to use of the knobs in order not to jeopardise the effectiveness of the treatment. Use the device only with electrical systems compliant with Safety Standards in force. The device has IP20 protection rating (see chap. Technical features ). It must not be used in the immediate vicinity of liquids because it is not protected from their entrance. Do not use the device in the immediate vicinity of mobile phones (keep them at least a few meters away). Operating near (for example 1 metre away) a short wave or microwave therapy device can cause instability in the output of the stimulator. Do not connect the patient with α LASER and an HF surgical device at the same time, to avoid danger for the patient and for the device itself. The device works according to its specifications if the atmosphere is kept at a temperature between 5 and 40 C and less than 80% humidity. The same conditions must be maintained during transportation and storage. In case of malfunctioning and failures, do not use the device but send it to be repaired. Do not operate near flammable substances. Do not use gel and accessories other than those supplied. It is of the utmost importance to inform the patient about the type of sensations which must be perceived during the therapy. Should he perceive that the sensation is no longer the correct one, you must intervene immediately, stopping the session by the controls and disconnecting the solenoids. If the intensity of the output set or its regulation cause excessive heating or pain in the treated zone, the intensity must be reduced immediately or the application must be stopped. Keep the device out of the reach of children. Both the patient and the operator must compulsory always wear protective goggles included in the basic supply. The device must only be used inside closed premises, adequately protected against random access of unauthorised personnel Rev. 00 of 12.06.09 17/20

Cap.9 TECHNICAL FEATURES 9. 1 P o w e r s u p p l y Internal power supply: ROAL-MCA600 PRI: 100-240V 47-63Hz SEC: 15V- 10A; 12V-12,5A; 5V-24A 9. 2 O u t p u t f e a t u r e s LASER:MDL4-13W980-7W808-10W1064-RP-PD 808 nm: 7W 980 nm: 13W 1064 nm: 10W 9. 3 O t h e r f e a t u r e s Size: 44x38x21h [cm] Weight: 4.38 [Kg] Class: I Type: BF Classification for entrance of liquids: IP20 Safety in presence of flammable anaesthetic gas: it is not category AP or APG Device for functioning: continuous Manufactured according to Standards: EN 60601-1 (2010) Medical electrical equipment: General safety standards EN 60601-1-1 (2003) Collateral safety standard EN 60601-1-2 (2003) Collateral standard: Electromagnetic compatibility Provisions and tests EN 60601-1-4 (1997): Collateral standard: Programmable electrical medical systems EN60601-1-4/A1 (2000) General requirements for safety of programmable devices. EN 980-2003 and EN 1041 Graphical symbols for labelling of electrical medical devices EN 60601-2-22- Safety of Laser equipment EN60825-1 Classification of laser equipment EN60601-1-6 Usability Rev. 00 of 12.06.09 18/20

S.N. αls AA XXXX Series number (S.N) Identification code of α LASER Identification number of device Year of manufacture Cap.10 BASIC SUPPLY AND ACCESSORIES 1 0. 1 B a s i c s u p p l y α LASER is complete of: N. 1 Appliance N. 1 protective goggles for the operator N. 1 protective goggles for the patient N. 1 knob 1 power cable 1 User manual N. 1 Trolley 1 0. 2 A c c e s s o r i e s a n d c o n s u m p t i o n m a t e r i a l The following is the list of accessories which can be purchased apart to increase the supply of the device or to replace worn elements: -knob -protective goggles for the operator -protective goggles for the patient -Use manual -Trolley Rev. 00 of 12.06.09 19/20