GB Collins Engineering PA

Similar documents
GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST

ROCKDALE COUNTY NEW SWIMMING POOL PLAN REVIEW

WORCESTER COUNTY HEALTH DEPARTMENT PRE-OPENING GUIDE SEMI PUBLIC POOLS 1. POOL WALLS AND BOTTOM SMOOTH, LIGHT COLORED AND EASILY CLEANABLE. (.

APPLICATION FOR A PERMIT TO CONSTRUCT OR ALTER A PUBLIC SWIMMING POOL, SPA POOL, WADING POOL OR FOUNTAIN

Jackson County Department of Public Health Application to Construct, Install, Remodel or Modify a Public Swimming Pool

Swimming Pool Requirements

Swimming Pool Requirements Packet

SWIMMING POOL REQUIREMENTS

Lincoln County Environmental Health Department 302 North Academy Street, Suite B Lincolnton, NC Phone: Fax:

KERN COUNTY PUBLIC HEALTH SERVICES DEPARTMENT ENVIRONMENTAL HEALTH DIVISION

WAKE COUNTY POOL PERMIT PRE-SEASON AUDIT 2014

WORCESTER COUNTY HEALTH DEPARTMENT PRE-OPENING GUIDE RECREATIONAL POOLS 2. DECK AND COPING MUST BE IN GOOD REPAIR AND PROPERLY DRAINED. (.

Chapter 10 SWIMMING POOLS

The purpose of this brochure is to explain to owners and contractors the City of Burnaby s requirements for private swimming pools.

Florida Department of Health Guideline for Routine Inspection Checklist

PLAN REVIEW NEW CONSTRUCTION AND MAJOR REMODEL WORKSHEET

Office Use Only Fee Paid

Swimming Pool Plans and Specification Report

Check with local zoning official for property line distance requirements.

SR: FA: PR: CT: All plans must be at least 18 x 24 and drawn to scale (min. ¼ per foot for pools or 1 per foot for spas and wading pools)

POOL AND SPA REPLASTERING AND/OR REMODELING REQUIREMENTS

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

SWIMMING POOL, SPAS, HOT TUB REQUIREMENTS AND GUIDELINES (Updated 3/2018)

Family Swimming Pool Planning Guide

Copies of your pool operator certificate as well the operating permit must be posted at the pool. The operator s certificate is your certificate that

AMITY TWP POOL REQUIREMENTS

City of Crystal Lake Community Development Department

PUBLIC POOL CHECKLIST. (This checklist is based on the Ministry of Municipal Affairs and Housing checklist)

Table of Contents. Section I: Checklist for Submitting Plans for Public Swimming Pools. Section II: Checklist for Submitting Plans for Spas/Hot Tubs

NEW SWIMMING POOL PLAN APPROVAL REQUIREMENTS

Swimming Pools, Hot Tubs and Spas

CHAPTER XXII SWIMMING POOLS 22 1 CONFORMITY REQUIRED.

SWIMMING POOL/SPA WADING POOL/SPRAY GROUND REQUIREMENTS

ARCHITECTURAL GUIDELINES ONE-PIECE COMMERCIAL

City of Lockport Above Ground Pool Regulations

SWIMMING POOL & SPA DOCUMENT SUBMITTAL LIST

Private Swimming Pool Permit Application

Cynthia Arias Pollution Control Coordinator

RESIDENTIAL SWIMMING POOL

Sunbrite LTC Large Underwater Pool Lights

ARCHITECTURAL GUIDELINES FOUR-PIECE COMMERCIAL

ARCHITECT GUIDELINES 1000 T

Take a closer look at; Parts - Equipment Systems

GENERAL AND STRUCTURAL DESIGN; EQUIPMENT STANDARDS. (i) Constructed of materials which are considered to be nontoxic to humans and the environment;

RESIDENTIAL SWIMMING POOL REQUIREMENTS

New Jersey State Sanitary Code Chapter IX Public Recreational Bathing N.J.A.C. 8:26 Changes 1/16/18

CONSTRUCTION PLAN APPROVAL PROCEDURE For Public Swimming Pools and Spas

2017 Florida Building Code 6 th Edition, Public Swimming Pool Changes, FBC Section 454.1, Effective January 1, 2018

COURSE SYLLABUS. Program for Resource Efficient Communities University of Florida PO BOX Gainesville, FL

FINAL EXPRESS TERMS FOR PROPOSED BUILDING STANDARDS OF THE CALIFORNIA DEPARTMENT OF PUBLIC HELATH

1 Exam Prep State Pool Contractor Feedback Questions and Answers

1 Exam Prep NSF/ANSI Tabs and Highlights

New England Municipal Building Officials Preventing Drowning and Suction Entrapment through Code Compliance

$ Plan Review Fee when Permit Application is submitted HOT TUBS AND SPAS BUILDING PERMIT APPLICATION. COST: $80.

ARCHITECTURAL GUIDELINES 1000 S

Pool Inspection. Your Street San Diego, California Prepared for: Your Name Prepared by: Priority Inspection Service

Dan Johnson, CBP Swim, Incorporated Lead Dog Aquatic Consulting

Florida Building Code 6 th Edition (2017) Residential. Broward County Edition Loose-leaf Supplement

* SEE ANCHOR SCHEDULE SHEET 7

Pool / Hot Tub Permit

Bulletin Swimming pool, hot tub and spa installations Rules , , , , , and

City of DuBois PERMIT APPLICATION P. O. Box 408, 16 West Scribner Ave - DuBois, PA Phone: Fax:

SECTION SWIMMING POOLS

PUBLIC SPA CHECKLIST. Planning and Building Department City of Mississauga 300 City Centre Drive, 3th Floor Mississauga ON L5B 3C1

Swimming Pool Permits are About Health and Safety

MDX² INSTALLATION MANUAL (RETROFIT FIBERGLASS, VINYL & CONCRETE POOLS WITH MDX)

PART I. GENERAL REQUIREMENTS FOR PERMANENTLY INSTALLED POOLS, STORABLE POOLS, OUTDOOR SPAS, OUTDOOR HOT TUBS, OR FOUNTAINS

VILLAGE OF ISLAND PARK LOCAL LAW NO. 12 OF THE YEAR A local law Private Swimming Pools

Swimming Pool Requirements

Saskatchewan Health S A WHIRLPOOL DESIGN/OPERATIONAL T C H E W STANDARDS. Updated 02/00

SWIMMING POOL / SPA PLAN REVIEW CHECKLIST

Welcome to the PMG Educational Program. Sponsored by:

Nottingham Township 909 Sugar Run Road Eighty Four PA (724) Fax (724)

Understanding and Compliance of the Virginia Graeme Baker Pool & Spa Safety Act

RESIDENTIAL SWIMMING POOLS, SPAS and HOT TUBS PERMITTING and INSPECTIONS GUIDE

LK4420BFFR - FTN, 4420BFFR - FTN. Owners Manual

PERMANENT POOLS. Location

FireLock NXT Dry Valve. System No. Submitted By Spec Sect Para Location Date Approved Date FIRE PROTECTION PRODUCTS DEVICES

Summary of Standards CMR : Minimum Standards for Swimming Pools

SECTION DOMESTIC WATER PIPING

Tampa: Davis Islands Recreation Area

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SWIMMING POOL PERMITS ARE ABOUT HEALTH AND SAFETY

Whitehall Township Swimming Pool, Spa and Hot Tub Code Guide

ARCHITECTURAL GUIDELINES FOUR-PIECE RESIDENTIAL

Residential Swimming pools

Figure Source:

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Public Swimming and Bathing Facilities Operators Guide 2018

FINDLAY TOWNSHIP BUILDING INSPECTION DEPT

Jennifer Hatfield FSPA Government Relations Consultant J. Hatfield & Associates, PL

Step-by-Step Planning Guide

TOWN of CHEEKTOWAGA Permit Application for Swimming Pools, Hot Tubs, or Personal Spas

SWIMMING POOL BUILDING PERMIT REQUIREMENTS FOR THE UNINCORPORATED TERRITORY OF DOUGLAS COUNTY, KANSAS

Building Department Informational Handout

RESIDENTIAL SWIMMING POOLS, SPAS and HOT TUBS PERMITTING and INSPECTIONS GUIDE

B o a r d o f H e a l t h

POOL AND HOT TUB/SPA REGULATIONS A BUILDING PERMIT IS REQUIRED BEFORE THE INSTALLATION OF A POOL.

Sunbrite Large Underwater Pool Lights

2009 NEW MEXICO SWIMMING POOL, SPA AND HOT TUB CODE

Transcription:

FENCE: Florida Building Code requires that all public pools shall be surrounded by a minimum 48" high fence. The fence shall be continuous around the perimeter of the pool area that is not otherwise blocked or obstructed by adjacent buildings or structures and shall adjoin with itself or abut to the adjacent members. ccess through the barrier other than from doored exits of adjacent building(s) shall be through self-closing, self-latching, lockable gates of 48" minimum height with the latch located a minimum of 4" from the bottom of the gate or at least " below the top of the gate on pool side. Gates shall open outward away from the pool area. GENERL NOTES: 1. Structure suitable when empty for ground water not higher than 6" above main drain.. Permanent Tile depth markers, minimum 4" high with contrasting color, slip resistant flush on deck or top of beam not more than feet from water edge and inside back of gutter (glaze minimum 4" high.. Permanent Red International NO DIVE Tiles, non-slip flush minimum 4" high, on top of the deck not more than feet from water edge every feet of perimeter maximum see detail. 4. ll equipment shall have NSF, UL, or appropriate approval.. ll electrical, grounding, wiring & bonding to comply with Florida building code FBC 014, th Edition, NEC Section 680 and 680.6(C). No overhead power within 10 feet. Electrician must certify compliance to engineer. NEC 680.6(C) requires that all parts specified in 680.6(B) shall be connected to an equipotential bonding grid with solid copper conductor, insulated, covered. or bare, not smaller than 8 WG or rigid metal conduit of brass or other identified corrosion-resistant metal conduit. Connection shall be made by exothermic welding or by listed pressure connectors suitable for the purpose and are of stainless steel, brass, copper, or copper alloy. 6. Pool make-up water is from an approved source with air gap. 7. No direct connections between water and sanitary systems, minimum " gap. 8. Vacuum breakers on all hose bibs in pool area. 9. Minimum 7' vertical clearance above deck and pool water 10. No food or drink services to be within 1 feet of inner edge pool deck. 11. Walkways between pool and sanitary facilities shall be impervious, slip resistant for the first 1 feet from pool water edge. 1. If night swimming is allowed, overhead lighting shall provide at least foot candles of illuminations at the water and wet deck level. 1. Overhead illumination of 0 foot candles at floor level in equipment room. 14. Owner to provide storage of chemicals under roof, protected from access by unauthorized persons. 1. Owner to provide traffic barriers at deck if needed. 16. Main drain(s) to meet SME/NSI 11 19-8-007, NSI/PSP-7 006 Section 1. lternative Methods, NSF0, 64E-9 and comply with Virginia Graeme Baker ct. 17. Feeders to be interlocked with recirculation pump. 18. Pipe: PVC schedule 40 NSFpw 19. Gauges: " minimum; 0-60 psi. 0. Test Kit: Taylor 006 or Equal 1. ll electric and ground to meet NEC or local code.. The equipment area or collector tank or chemical containers shall not be accessible to unauthorized individuals.. Install new equipment and plumbing per manufacturers instructions. 4. Plastic pipe subject to a period of prolonged sunlight exposure must be coated to protect it from ultraviolet light degradation. LL EQUIPMENT MUST BE LBELED ND ESILY RED, THIS INCLUDES THE FLOWMETER. 6. ll equipment (pumps, motors, pressure gauges, valves, auto and manual fills, piping, filters, flow indicators and flow meters ) must be operating properly before calling this office and/or the Health Department for inspection. 7. Lighting certification is not part of this submittal. Contact a Lighting or Electrical engineer for certification. 8. Direct access to equipment is required. 9. Pool and Bathhouse electrical outlets to be GFCI with trip points 6m or less with cover. 0. Pool chemicals to be stored away from other materials in a cool, dry, ventilated area with restricted access. 1. Pool to have Shepherd's Hook, Straight Pole, Ring Buoy for safety equipment.. The deck must not have pits and crevices more than 16" deep.. flow meter shall be provided with properly located and proper clearances upstream and down stream. 4. gate to the equipment area must be provide within 10' of the equipment area.. The equipment room area must provide clearances for all equipment as prescribed by the manufacturer to allow normal maintenance and removal. 6. ll equipment meets NSF/NSI Standards 0-007. 7, Recirculation pump must have a hair and lint strainer. 8. ll exposed PVC piping will be painted for UV protection. 9. The plans meet FBC 014, th Edition, Section 44.1. 40. The plans meet 011 National Electric Code 41. ll depth markers are to indicate actual depths within ". 4. This pool is exempt from D requirements, because it is not classified as a Title II or Title III public swimming pool (transient facility). See http://www.ada.gov/qa_existingpools_titleiii.htm for details. SITE PLN NOTES: 1. RINSE SHOWER SHLL BE PROVIDED ON THE POOL DECK WITHIN THE PERIMETER OF THE FENCE.. HOSE BIBB WITH VCUUM BREKER REQUIRED ON DECK.. WSTE TO SNITRY SEWER OR STORM WITH IR GP, MEET LOCL CODES, PINT EXPOSED PVC. ECH WSTE LINE SHLL HVE UNIQUE IR GP. WSTE LINES FROM DIFFERENT SOURCES SHLL NOT BE TIED TOGETHER, BUT MY DISCHRGE INTO COMMON SUMP OR RECEPTCLE FTER IR GP. (CONTRCTOR TO PROVIDE) 4. CONFIRM LOCTIONS ND ELEVTIONS WITH THE OWNER ND LNDSCPE CONTRCTOR.. NO FOOD OR DRINK FCILITIES WITHIN 1 FEET OF POOL 6. PROVIDE HOSE BIBB WITHIN FEET OF THE RESTROOMS 7. PROVIDE DIRECTIONL SIGNS TO RESTROOMS 8. NO RECLIMED WTER SHLL BE USED S N IRRIGTION SOURCE FOR THE RES LONG THE POOL DECK 9. PINT LL EXPOSED PVC. POOL INFORMTION Capacity:,000 Gallons rea: 1,64 Square Feet Perimeter: 09 Feet Units: 170 (non-transient) Pool Deck rea: 4,780 SF POOL RECIRCULTION PUMP: Valves: Proportional flow, ball globe, or butterfly for return line, main drain, gutter and heater by-pass or approved equal, otherwise gate.feeders to be wired with failure proof interlock with the recirculation pump. Pipe: PVC Schedule 40 NSFpw Gutter: Pentair 4006 ("x 4") Flow Meter: Blue White CF 000P Vacuum Fitting: Hayward VC-LOCK nchors: Hayward SP19 Transformers: rea Lighting LG-00 / 1Volt. Leaf Skimmer: LION 1010 Vacuum Head: RINBOW 14 Brush: &B 004 Vacuum Hose: Plastiflex Shell: Concrete, 00 psi, 8 day, rigid construction Steel: STM GR40, 61 Poles: () Jed, 16' Straight Heater: () Lochinvar ER-40 (99,999 BTUs Each - Must be Fenced) Pool Finish: Krystalkrete, Salt & Pepper MSONRY WLL (SEE RCHITECTURL PLNS FOR DETILS) CONTRCTOR TO VERIFY WLL FOOTER DEPTHS PRIOR TO POOL PLUMBING INSTLLTION MIN. 48" HIGH FENCE OR WLL (SEE HRDSCPE PLNS FOR DETILS) POOL PENTIR WHISPERFLO-XF, XFE-1, H.P., SELF-PRIMING 10 GPM @ 0' TDH FILTER: WDE VCUUM D.E., (17) 1." X 4" ELEMENTS, 4. SQ. FT. E. 76. SQ. FT. TOTL, 1 GPM CPCITY POOL VCUUM PUMP: CHEMICL FEEDERS: Marcite: Manufacturer: Krystalkrete Style: Salt and Pepper Waterline tile: Manufacturer: merican Olean Vendor: Gulf Tile Contact: Terri Fleming Phone: (81) 6-07 Style: Block Glass Mosaic Color: Sea Pearl Product #: C18 STENNER 4M (CL), 0 GPD STENNER 4M (ph), 10 GPD EQUIPMENT FETURE PCK HETERS MIN. 48" HIGH FENCE OR WLL (SEE HRDSCPE PLNS FOR DETILS) POOL SFETY EQUIPMENT (1 OF ) Level (Static) Line Grate: SP1019. Inlets: Hayward SP14 Escutcheons: Frost 41661 Lights: Pentair Intellibrite G Color Changing, LED 00w Equivalent, ground/nec. 011, FBC 014, th Edition. Life Ring: () 4" W/0' Throw Line, Jim Buoy Hook: () RINBOW 1 Test Kit: Taylor K-006 Ladder: Smith LFB 6B Tread: 6" Maximum from wall, " Minimum from wall. Crossed Braced Stainless Steel, Slip Resistant Treads, 8" minimum above deck. Must have caps or bumpers that rest firmly against pool wall. Main Drain: Lawson 11 1x1 GRTE-SECURE Flow Rate: 10 GPM ST-RITE MX-E-PRO, 1 H.P., P6E6E, SELF-PRIMING, 70 GPM @ 60' TDH Grout: Spectralock Pro Grout - Bright White dhesive: Laticrete Glass Tile dhesive Note: Contractor to ensure glass tile installation meet the following: - NSI 108.16 Contractor to ensure glass tile adhesive meets the following: -NSI 118.4, 118.11, ISO 1007-, C1Te Contractor to ensure glass tile grout meets the following: -NSI 118. Marking Tile: Black - Contractor to provide Samples for pproval POOL SHOWER WITH HOSE BIBB ND VCUUM BREKER POOL POOL SFETY EQUIPMENT ( OF ) MENS WOMENS MIN. 48" HIGH FENCE OR WLL (SEE HRDSCPE PLNS FOR DETILS) POST POOL RULE SIGN NO GLSS OR NIMLS IN THE FENCED POOL RE NO FOOD, OR BEVERGES IN POOL OR ON WET DECK SHOWER BEFORE ENTERING POOL MX. MIN POOL LOD 0 PERSONS DO NOT SWLLOW POOL WTER NO DIVING Gutter Lip Tile: Teal (To Match Teal in Waterline Tile) Contractor to provide Samples for pproval POOL HOURS DWN a.m. TO DUSK p.m. (Until lighting certified) NOTE: Pool Rule Letters to be 1" high minimum except NO DIVING shall be 4" high minimum. (SIGN TO BE PROVIDED BY OWNER) OCCUPNT LOD CLCULTIONS IN CCORDNCE WITH NFP 101, 01 EDITION (FROM TBLE 7..1. ) SWIMMING POOL WTER SURFCE: SWIMMING POOL DECK RE: SWIMMING POOL OCCUPNT LOD TOTL OCCUPNT LOD: MINIMUM REQUIRED EGRESSES PER SECTION 7.4.1: 1-00 01-1000 > 1001 4 SITE PLN SCLE: /" = 1' + 1,64 -. 0 = 4,780 -. 0 = 19 191 191 LOCTION MP - NTS ddress: Nearest intersection: North Dale Mabry Highway & Geraci Road Lutz, FL 48 Hillsborough County RESTROOMS TBLE OF CONTENT: SITE LOCTION LL EQUIPMENT IS SPECIFIED ON THE BSIS OF DESIGN. SUBSTITUTION FOR NY EQUIPMENT NEEDS TO BE PPROVED BY THE DESIGN ENGINEER ND OWNER. THE OWNER IS NOT RESPONSIBLE FOR FEE JUSTMENTS FOR BIDS THT HVE BEEN SUBMITTED BSED ON CONTRCTORS EQUIPMENT THT IS NOT SPECIFIED ON THE PLNS ND NOT PPROVED BY THE DESIGN ENGINEER. Outside access to facilities shall be provided for bathers at outdoor pools and if they are not visible from any portion of the pool deck, signs shall be posted showing directions to the facilities. These directions shall be legible from any portion of the pool deck and the letters shall be a minimum of one inch high. Walkways shall be provided between the pool and the sanitary facilities, and shall be constructed of concrete or other nonabsorbant material having a smooth slip resistant finish for the first 1 feet of the walkway measured from the nearest pool water's edge. Floors: smooth, non-slip, impervious, pitched to floor drains, cove wall to floor, no carpet, duckboard or footbaths. Provide permanent towel, tissue, soap dispensers and waste baskets. Label doors. Install hose bib w/ vacuum breaker, either in resorts or outside nearby. Water shall be from an approved potable source with air break. Diaper changing tables shall be provided at facilities that cater to families with small children. NOTE: Restrooms are located within 00 FT walking distance of pool waters edge. RESTROOM FCILITIES: RE WITHIN 00 FEET WLKING DISTNCE FROM THE WTERS EDGE. SHLL BE T LEST S INDICTED ON THE FOLLOWING TBLE: TOTL RE MEN'S RESTROOM WOMEN'S RESTROOM IN SQ. FT. URINL W/C LVTORY W/C LVTORY 0 -,00 1 1 1 1 1,01 -,000 1 1 1,001-7,00 6 7,01-10,000 9 SITE PLN, SPECIFICTIONS ND NOTES 1 POOL PLUMBING PLN POOL LYOUT PLN POOL PROFILE ND DETILS 4 POOL EQUIPMENT DETILS #1 POOL BONDING PLN 6 Sheet 1 of 6 Clearview Land Design For: Site Plan, Specifications and Notes

LEGEND SCLE: 1/4" = 1' 1 GRVITY 17 9 66 117 64 470 SUCTION 9 1 9 940 PRESSURE 98 0 9 881 1,67 1 GRVITY, MXIMUM FLOW, IN GPM, T.0 FPS SUCTION, MXIMUM FLOW, IN GPM, T 6.0 FPS PRESSURE, MXIMUM FLOW, IN GPM, T 10.0 FPS POOL PLUMBING PLN PIPE DIMETER 1..0.0 4.0 6.0 8.0 Pool Plumbing Plan MXIMUM FLOW VELOCITIES (GPM) For: Clearview Land Design FETURE FLOWS FETURE 1.Pentair MagicStream Laminar.Pentair MagicStream Laminar.Pentair MagicStream Laminar 4.Pentair MagicStream Laminar.Pentair MagicStream Laminar 6.Pentair MagicStream Laminar PIPE RETURN SIZE FLOW TOTL # Date 60 GPM Sheet of 6

POOL LYOUT PLN SCLE: 1/4" = 1' For: Clearview Land Design Pool Layout Plan SR SMITH (1.90" O.D.) CUSTOM RIL SR SMITH 1.90 O.D. CUSTOM RIL Sheet of 6 Pool Step and Rail Detail #1 Pool Step and Rail Detail # N.T.S.

Section - Main Pool Section TILE SME S STEPS NOT TO EXCEED 18" Transverse Pool Section, Deep Portion DEPTH MRKER DETILS Bench Detail Ladder Custom: S.R.Smith Custom, Stainless Steel Tread: 6" Maximum from wall, " Minimum from wall. Cross Braced, Slip Resistant Treads, 8" minimum / 6" max above deck. Frame, 1.9" OD x.06", Type 04 Stainless Steel, with white rubber bumpers. Steps, acrylic plastic and have a slip resistant top surface. Escutcheon, (p/n EP-100F), stainless steel. nchor ssembly: S-100B (see spec sheet for SRS-908) Pool Profile and Details DEPTH MRKER DETILS For: Clearview Land Design 18" Ladder Detail Æ # Transverse Main Pool Section, Shallow Portion Sheet 4 of 6 Main Drain Detail Æ Gutter,Wall and Floor Detail STEP TILE FLOOR RETURN DETIL Date

TOTL HED 110 100 90 80 70 60 0 40 0 0 10 WHISPERFLO/MX-E-PRO XF PERFORMNCE CURVES F E 0 0 0 0 40 60 80 100 10 140 160 180 00 0 40 60 80 00 WhisperFloXF FLOW RTE IN U.S. GPM PUMP MODEL D Max-E-ProXF B C PERFORMNCE CURVE XF-1 XF-0 B, 110 100 90 80 70 60 0 40 0 0 10 FIELD CST 6" THICK, 00 PSI CONCRETE FOOTING UNDER STEEL FRME & COVER SIDEWLL VENT (TYP BOTH SIDES) 1" x 1" STEEL FRME SHIM FRME ON BRICKS S NEEDED FLEX HOSE WSTE LINE IR GP DETIL WSTE LINE FROM POOL FILTER NOTES: 1. PLUMBING - LL PIPE & FITTINGS SHLL BE SCHEDULE 40 PVC PER STM D178 ND N.S.F. PPROVED ND STMPED FOR POTBLE WTER PPLICTIONS. JOINTS TO BE SOLVENT WELDED PER STM D8. LL PLUMBING ND MTERILS TO CONFORM TO FLORID BUILDING CODE 014 - FIFTH EDITION.. ELECTRICL - LL ELECTRICL EQUIPMENT WIRING, INSTLLTION ND GROUNDING OF POOL COMPONENTS SHLL CONFORM TO NTIONL FIRE PROTECTION SSOC. 70, NTIONL ELECTRICL CODE (N.E.C.) LTEST EDITION ND LL PPLICBLE LOCL CODES. CHEMICL FEED PUMPS TO BE INTERLOCKED WITH THE RECIRCULTION PUMP.. EQUIPMENT - LL PUMPS, FILTERS ND DISINFECTION EQUIPMENT SHLL BE TESTED ND PPROVED BY THE PERTINENT MNUFCTURER USING THE NSF/NSI STNDRD 0 ND LISTED S PPROVED BY THE NSF. 4. THE FILTER ROOM FLOOR IS SLIP RESISTNT ND SLOPED TO FLOOR DRINS. LL PLSTIC PIPING SUBJECT TO PROLONGED SUNLIGHT EXPOSURE MUST BE COTED TO PROTECT IF FROM ULTRVIOLET LIGHT DEGRDTION. 6. ECH WSTE LINE SHLL HVE UNIQUE IR GP. WSTE LINES FROM DIFFERENT SOURCES (E.G. POOL, SP, OVERFLOW, SUMP PUMP) SHLL NOT BE TIED TOGETHER BUT MY DISCHRGE INTO COMMON SUMP OR RECEPTCLE. 7. THE WSTE LINE MUST BE CONNECTED TO N PPROVED WSTE DISPOSL SYSTEM CCORDING TO LOCL OR STTE CODES. 8. LL COLLECTOR TNKS SHLL HVE COVED INTERSECTIONS ND SLOPE TO THE TNK DRIN. 9. N UTOMTIC ND MNUL WTER MKEUP CONTROL MUST BE PROVIDED TO MINTIN THE WTER LEVEL T THE LIP OF THE OVERFLOW GUTTER OR T THE MOUTH OF THE RECESSED UTOMTIC SKIMMERS ND MUST DISCHRGE THROUGH N IR GP INTO FILL PIPE OR COLLECTOR TNK. OVER THE RIM FILL SPOUTS RE PROHIBITED. 10. RTE OF FLOW INDICTOR, REDING IN GPM, SHLL BE INSTLLED ON THE FILTER RETURN LINE. THE RTE OF FLOW INDICTOR SHLL BE PROPERLY SIZED FOR THE DESIGN FLOW RTE ND SHLL BE CPBLE OF MESURING FROM ONE HLF TO T LEST ONE-ND-ONE-HLF TIMES THE DESIGN FLOW RTE. THE CLERNCES UPSTREM ND DOWNSTREM FROM THE RTE OF FLOW INDICTOR SHLL COMPLY WITH THE MNUFCTURER'S INSTLLTION SPECIFICTIONS. 11. THESE PLNS HVE BEEN PREPRED IN COMPLINCE WITH THE 014 FLORID BUILDING CODE - FIFTH EDITION VCUUM DE FILTER EQUIPMENT LIST - 10 GPM SIDE ELEVTION RECIRCULTION PUMP VCUUM PUMP PENTIR WHISPERFLO XF, XFK-1, HP, SELF-PRIMING, 10 GPM @ 0' TDH ST-RITE MX-E-PRO 1 HP P6EE6-06L, SELF PRIMING, 70 GPM @ 60' TDH, 11/0V FILTER TNK SIZE T0-0 GLLON CPCITY DE FILTER ELEMENTS (17) - 1." x 4" ELEMENTS, 4. SQ FT ECH, 76. SQ FT TOTL WTER LEVEL CONTROL QUTEK HYDRULIC VLVE W/ MNUL FILL VLVE & RESERVOIR CHLORINE FEEDER STENNER 4M, 0 GPD CPCITY, 110V THERMOMETER 0 GL RESERVOIR LBELED "ph" " FLOWMETER 0GL RESERVOIR LBELED "CHLORINE" TOP VIEW LOCKBLE LIDS " FROM HETER 60W SERVICE LIGHT " TO HETER " BUTTERFLY VLVE." PRECOT " " VCUUM TO FILTER 1" UTO FILL VLVE WITH MNUL CONTROL " OVERFLOW WITH CHECK VLVE 4" DRIN VLVE " LEVEL SENSOR 4" RECIRCULTION PUMP SUCTION US 1040 66th STEET ST. PETERSBURG, FL 78 ( 7 7 ) 9-8 8 4 WPDE00/ F 00GPM FILTER TNK ID PLN VIEW " DE FILTER ELEMENTS " TNK DRIN." PRECOT T COLLECTOR TNK 4" DRIN VLVE T10 FETURE COLLECTOR TNK C B CHLORINE RESERVOIR TNK ph FEEDER ph RESERVOIR TNK SEPRTOR TNK FLOWMETER THERMOMETER VCUUM GUGE () PRESSURE GUGE FETURE PUMP FETURE TNK FETURE FILTER ELECTRICL SCHEMTIC 0 GLLON WITH LOCKBLE LID STENNER 4M, GPD CPCITY, 110V 0 GLLON WITH LOCKBLE LID PENTIR PEN100, 100 SF CPCITY 4" BLUE/WHITE F-0400P, 1 TO 00 GPM RNGE PRECISION INSTRUMENT CO BB1-K WITH 1/" NPT THERMOWELL WIK, 0-0 IN HG, LIQUID FILLED, 1/4" NPT, " FCE DIMETER WIK, 0-60 PSI, LIQUID FILLED, 1/4" NPT, " FCE DIMETER ST-RITE MX-E-PRO 1 HP P6EE6 T10-10 GLLON CPCITY STRITE PLM00, 00 S F FILTER RE PIPE ND VLVES CHRT MIN DRIN GUTTER/SKIMMER STTIC LINE LINE FUNCTION RECIRCULTION PUMP SUCTION () RECIRCULTION RETURN VCUUM LINE TO POOL VCUUM TO FILTER WSTE LINE FILTER PRECOT OVERFLOW." TO HETER FROM HETER " FETURE SUCTION 4" FETURE RETURN " FETURE MIN 4" 6" 6" " 4" 4" " " " " " SIZE For: Clearview Land Design Pool Equipment Details#1 " FILTER RETURN DE SEPRTION TNK " TO WSTE VCUUM PUMP CHEMICL FEEDERS CRTRIDGE FILTER " FETURE RETURN " TO CRTRIDGE FILTER FETURE PUMP 4" FETURE SUCTION ELECTRICL PNEL " BUTTERFLY VLVE (RECIRCULTION PUMP SUCTION) F G FIXTURE SCHEDULE: H E 6 4 6 1 8 D H FEEDER & CIRCUIT SCHEDULE: Conductors Mark Phase Neutral Ground Conduit Remarks 1 4 6 7 8 Panel Feed - #1 1-#1 1/" UL Sealtite - #8 1-#8 /4" UL Sealtite - #10 1-#10 1/" UL Sealtite 1 - #1 1 - #1 1 -#1 1/" Sealtite To Panel 1 - #1 1 - #1 1 - #1 1/" Sealtite To Panel 1 -#1 1 - #1 1 - #1 1/" Sealtite To Panel Conductors and Conduit Installed By Others Sheet of 6 FILTER EQUIPMENT PLN ' x 11' CBINET - WITH INTERNL FILTER TNK Mark Voltage Manufacturer & Model No. B C D E F G Main lug breaker panel 10, 08/0V. C-H BR4L1SP (4 Circuit) Recirculation Pump Feature Pump 0 V. 1ɸ 0 V. 1ɸ Pentair XFK HP Vacuum Pump 0 V. Sta Rite Max-E-Pro P6EE6 1 HP 100 Watt Service Light Fixture 11 V. Intermatic VPXG11GCI 100W Chlorine Feeder Pump 11 V. Stenner 4M cid Feeder Pump 11 V. Stenner 4M H GFCI 11 V. Pass & Seymore Sta Rite Max-E-Pro P6EE6 1 HP PNEL SCHEDULE: THREE PHSE, 4-WIRE 10/40 VC INSULTED/BONDBLE NEUTRL Circuit Pole Trip Load mps 1 0 Rec. Pump w/ Interlocked Chem. Feeders 8. 0 Vacuum Pump 1. 0 Feature Pump 1. 4 0 GFCI 1 1 Service Light 1. Total Maximum Load 1.8

NOTES: 1) #8 SOLID COPPER BONDING WIRE TO BE RUN CONTINUOUS TO POOL FILTRTION EQUIPMENT ND ELECTRICL SUPPLY PNEL. ) BOND TO LL METLLIC ITEMS LOCTED IN THE POOL ND TO THE REBR. For: Clearview Land Design Pool Bonding Plan Sheet 6of 6