Innovation and Safety Efficient Solution

Similar documents
Operation & Maintenance instructions for the Söll Vi-Go type fall protection system with guided type fall arrester

SET OF EUROLEAGUE BACKSTOP UNITS (Reference PK120)

Extension Platform. Base Platform. Crossover. Exit railing. Exit Railing

TRAVSMART permanent single-cable horizontal lifeline system

Technical Briefing Note

PRODUCT BROCHURE. RMD Kwikform USA. Ascent-F

Height-safety devices

Söll GlideLoc vertical rail system


Install Manual October 2011

Miller DuraHoist Safety Systems

MSA Latchways Ladder System

TYPICAL S/W TOWER STATIC STABILISER IMPORTANT NOTES

LAD-SAF LAD-SAF VERTICAL SAFETY SYSTEM THE ULTIMATE IN FALL PROTECTION

Handling procedure for Scrubbers and Tanks made of thermoplastics.

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

??????? is committed to providing a safe work environment for its employees and preventing occupational injuries due to falls.

Assembly, Installation and operating. instructions for. Söll-Xenon anchorage device

SECURITY AND CONFIDENCE AT HEIGHT

Assembly, disassembly and user manual

S-60-TO : 1 ton tower system INSTRUCTION MANUAL

GANTRY CRANES CAPACITIES: SPANS: TRACKS: OPTIONS: Up to 5 tons Up to 30' Steel Fixed or Adjustable

WE DON T STOP AT BARRIERS

RIGGERS SAFETY SAFETY IS IN THE DETAILS FULL LINE CATALOG

TENSOREX C+ TENSOREX C+

The future of climbing

FALL PROTECTION GUIDELINE

New Mexico Institute of Mining & Technology. Fall Protection Program

built build to TRENCHLINING DOWN A CAISSON

TECHNICAL CIRCULAR. Circular No: S-P 31/13 Revision: 0 Page: 1 of 5 Date:

Operating manual Mobile Man Anchor IM-200 Reference No. IM 200

DOUBLE SAFETY: NO PANIC, NO BACTERIA

Floor Mount Socket. T: +44 (0) F: +44 (0)

MSA Latchways Solutions for Industry

RIGGERS SAFETY SAFETY IS IN THE DETAILS FULL LINE CATALOG

FALL PROTECTION WORK PLAN (Alstom Power Installation Canada)

tirak Traction hoists with limitless pulling length for man riding and material handling Capacity from 300 to 3000 kg

Vibration isolation system 1VIS10W. User manual

FALL PROTECTION PROGRAM (OHS-0010)

08/2017. No Instructions for assembly and use for fixed ladders

PERSONAL FALL PROTECTION

DBI SALA Advanced Hoist Systems

Security and confidence at height.

Safety Tips from the WorkSafe People

Fall Protection Resource Guide P AGE 1

Rapid Recovery Solution (R2S)

CATALOG INDEX. Removable Anchors. Toggle Anchors. I-Beam Anchors. Steel Slings. MegaSwivel Family. Swivel Kits. Mining Anchors.

Name of product: Gripper for vertical façade FTV panels Types: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) INSTRUCTIONS FOR USE

Hand winch MANIBOX GR

Manual for the. Installation. Use and Maintenance. "Söll-GlideLoc" fall arrest system. Ho-Ver turn table

PRODUCT BROCHURE. RMD Kwikform United Kingdom. Ascent-F

A18W35_MASE 130_F_EN MANUAL

WINSAFE Corp. Operating Instructions For Outrigger Davit. Winsafe Part # WSOR208

TRUSTED. DURABLE. RELIABLE.

Installation Instructions for the AlphaDeck Staging System

PFC Lightweight Composite Push Up Mast. Operating Manual

TECHNICAL MANUAL. COPRA Anchoring Coupler. For Smart Bolted Connections

Fall Protection / Open Holes & Guardrail

RULES PUBLICATION NO. 44//P PILOT TRANSFER ARRANGEMENTS July

SECTION FACILITY FALL PROTECTION PART I - GENERAL

MSA Confined Space Entry Equipment

FALL PROTECTION

Product Numbers & Ordering Information

User Instruction Manual Fixed Beam Anchor

GO BEYOND! The Helio A7 is one of the lightest, most efficient folding aluminum chairs in the industry.

ORNAMENTAL CANTILEVER GATE INSTRUCTIONS

DREW UNIVERSITY FALL PROTECTION PROCEDURE (DRAFT 12/11)

Department of Facilities Management. Occupational Health and Safety. Fall Protection Program

Check with local zoning official for property line distance requirements.

TRUSTED. DURABLE. RELIABLE.

Sit to Stand Umbilical Solutions

Operating instructions. Skyline Beam Clamp

XTS-Impact. XTS-Terminal (hold)

Pneumatic spool valve islands

APPROVED MAIN COURSES

Intermediate Angle, 0-25, Drilling detail. Angle 26-50, Baulk Plates, Pole Details. Termination Poles, ABC Details

FALL RANGE PROTECTION

OLD GI PART 3, FIXED LADDERS COMPARISON TO NEW RULES

RESOLUTION MSC.94(72) (adopted on 22 May 2000) PERFORMANCE STANDARDS FOR NIGHT VISION EQUIPMENT FOR HIGH-SPEED CRAFT (HSC)

Instruction Manual AC350 GUIDED-TYPE FALL ARRESTER ON RIGID ANCHORAGE LINE EN 353-1:2002

MLV Mast Series Sectional Tripod Mast, 10-34m (32-110ft)

RESOLUTION A.1045(27) RECOMMENDATION ON PILOT TRANSFER ARRANGEMENTS

G F T German Formwork Technology. Climbing Bracket CB 240. Assembly and Application Guide

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6

ATOM-X 2. User Manual

ISO INTERNATIONAL STANDARD. Personal protective equipment for protection against falls from a height Single-point anchor devices

welcome message Rakesh Modi (Chairman, Mtandt Group)

Technical Data Sheet TI-F50 Locking Units series KFH

TRUSTED. DURABLE. RELIABLE.

Overview. Identify fall hazardous areas Describing potential fall hazards How appropriate portable and extension ladders are used

INNOVATIVE BROACHING TECHNOLOGY

Operations and Instruction Manual Might Swivel Model # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn

BERMAD Fire Protection Hydraulic Control Valves

THIS IS INDRA NAVIA COMPANY HISTORY. Gustav A Ring AS established (GAREX) Norsk Marconikompani AS established (NORMARC)

Assembly Instructions

User Instruction Manual Fixed Beam Anchor

Fall Protection Guidelines. Individual Unit Function: Safety Procedure No.: SOP-0111 Page: 1 of 13. Preparer: Owner: Approver: Safety Safety Safety

Know Your ABCs FALL PROTECTION GUIDE

FALL PROTECTION / ELEVATED WORK

Crane Rental Heavy Machinery Moving Project Management

Transcription:

Innovation and Safety A Simple, Efficient Solution Metalusa regarded innovation and safety as mandatory requirements for the implementation of the Towrok shoring towers. These two requirements are met without prejudice to the functionality of the product and two of its main strengths are its speed of assembly and dismantling as well as the durability of the system. Towrok shoring towers are endowed with high quality, complying with Standard EN 12813 achieved by means of a high-tech production system. The shoring towers built by elements, once assembled, form a rigid, very safe structure. The elements of the Towrok system are made to withstand loads of at least 100 kn per element or 200 kn per tower, constituting the best option for shoring at a height of heavy loads with minimum safety requirements. Towrok shoring towers are the system indicated for implementing highly complex works in which the versatility of the equipment is a pre-requisite, always maintaining high safety indices, to wit under heavy load conditions. The production system used to manufacture the Towrok Towers deploys totally automated, robotised technology. METALUSA SEEKS TO MEET THE REQUIREMENTS OF THE MARKETS WHERE IT OPERATES, PROVIDING PRODUCTS THAT OUTPERFORM EXPECTATIONS, COMBINING INNOVATION, SAFETY AND QUALITY. 132 133

Productivity at the Works Site The components of the Towrok shoring system were developed to allow simple assembly and dismantling so as to get a better performance out of the costs associated with these operations. The Towrok shoring system deploys a low number of elements, thereby seeking to boost productivity at the works site and to achieve low maintenance operation costs. To boost productivity in the movement of Towrok shoring tower structures with the aid of a crane, two innovative technical solutions have been developed. At the base of the structure the leveller has an attachment plate for connecting the leveller quickly and safely to the shoring element. The connecting bar links the elements at a height and they are secured by the safety latch built into the element. The Towrok shoring system can be easily adapted to any kind of formwork. The system is endowed with a set of safety elements which allow easy, totally safe assembly and dismantling in line with the most demanding standards in force. The combination of the various elements allows the implementation of Shoring Towers which are between 1,70m and 10m high. For heights exceeding 10m, it is necessary to calculate the stability of the Towrok structure. For towers whose height exceeds 5m, the elements need to be tied to each other every 3m of height using Ø48x3,2mm tubes and 48/57mm fixed clamps. 134 135

Stability and Safety Under normal usage conditions the Towrok Tower is self-standing up to 5m high. Between 5 and 10m high the structure of the towers must be tied to each other by means of a tube and clamp and with diagonals. For heights exceeding 10 metres a stability calculation must be carried out based on the product manual. Where necessary, said calculation can be carried out by the Metalusa engineering services. The assembly and dismantling of the Towrok shoring towers is straightforward, making the system highly versatile and capable of resolving the most varied situations at the works site. 136 137

Assembly Productivity 1 ST STAGE Untie and remove the 1st element to start assembly. 2 nd STAGE Assemble 2 base levellers and then the shoring element. 3 rd STAGE Assemble two 1,60x1,25 diagonals at the element. 10 th STAGE Place two 1,0 x 1,20m elements. 11 th STAGE Move the platforms 0,5m downwards. 12 th STAGE Place another platform level 2,0m away. 4 th STAGE Assembling the shoring element on the opposite side. 5 th STAGE Assembly 2 Guardrails from the ground upwards. Level and vertically align the structure. 6 th STAGE Place another 2 elements and then close the Guardrail safety latch. 13 th STAGE Assemble two 1,6 x 0,75m diagonals at the elements as from the 2nd level of platforms. 14 th STAGE Assemble the forks and adjust to the necessary elevation. 15 th STAGE Place the beams on the forks. THE TOWROK SHORING TOWER ALLOWS GREAT PRODUCTIVITY: Rapid assembly; Easy assembly with the aid of a connector; 7 th STAGE Place the platforms on the element bars. 8 th STAGE Place 1 diagonal and a Guardrail from the working platforms. 9 th STAGE After placing the diagonal and Guardrail on the opposite side. The base levellers and forks allow speedy adjustment and levelling; The safety latch and the affixation plate keeps the structure joined when moving from one position to another. 138 139

Towrok Elements P040101 REINFORCED SHORING ELEMENTS Weight (Kg) P040106 DIAGONALS FOR Weight (Kg) P0401011000G Galv. Shoring element 2R 1,2x1,0 m 12,50 P0401060750G Galv. Diagonal "X" with Ø30mm 1,60x0,75m 4,50 P0401061250G Galv.Diagonal "X" with Ø30 mm 1,60x1,25m 6,10 P0401011500G Galv. Shoring element 3R 1.2x1.5 m 18,40 P0401061600G Galv. Diagonal in "V" with Ø30 mm 1,60m 6,30 P040102 SUPER REINFORCED SHORING ELEMENTS Weight (Kg) P0401021000G Galv. shoring element 4R 1,2x1,0m 16,00 P040108 ASSEMBLY GUARDRAIL FOR SHORING TOWERS Weight (Kg) P0401021500G Galv. shoring element 6R 1.2x1.5m 24,40 P0401081600G Galv. Assembly guardrail for shoring towers 1,60m 14,00 P040103 SHORING TOWER TERMINAL ELEMENT Weight (Kg) P040109 BASE LEVELLERS WITH CLAMPING CHUCK Weight (Kg) P0401031000G Galv. tower terminal 2R 1,2x1,0m 13,90 P0401090900G Galv. Base leveller Ø48+clamping chuck with 0,90m 6,90 P040104 BARS FOR Weight (Kg) P0401041600G Galv. Towrok horizontal bar Ø30 mm with 1,60m 2,20 P040111 ARTICULATED BASE LEVELLERS Weight (Kg) P0401110900G Galv. Articulated base leveller Ø48 with 0,90m 7,00 P0401051600G Galv. Towrok connection bar 1,60m 6,60 P040112 FORKS FOR Weight (Kg) P0401050160G Spigot w/ Ø48x160mm 0,63 P0401120500G Galv. Fork 235x150 Ø48 with leveller 0,50m 4,40 P0401120900G Galv. Fork 235x150 Ø48 with leveller 0,90m 8,00 140 141

P040190 SHORING TOWER ACCESSORIES Weight (Kg) P040190 SHORING TOWER ACCESSORIES Weight (Kg) P0401900004G Fork accessory to secure wooden beams 5,00 P0401900001G Galv. support base for shoring towers 1,00 P010150 STANDARD STEEL PLATFORMS 300mm Weight (Kg) N45NCB0600000005 Galv. orthogonal bracket 60/48 1,28 P0101501600G Galv. metallic platform 1,60x0,30m 11,60 P0401900003G Galv. pallet for shoring elements Towrok 26,50 P040115 STANDARD SERVICE PLATFORMS Weight (Kg) P0401151600 Service platform made of aluminium/cp 1,60x0,70m for Towers 15,60 P040118 TOWROK SKIRTINGS Weight (Kg) P0401181200 Side skirting 1,20m - Towrok 2,90 P0401181600 Front skirting 1.60m - Towrok 4,00 142 143

Metalusa S.A. Phone +351 234 529 230 Fax +351 234 529 239 metalusa@metalusa.pt www.metalusa.pt