EG15*... SERIES. SOLENOID GAS VALVES WITH 1/2 CONNECTION AND OPERATING PRESSURE UP TO 500 mbar DESCRIPTION

Similar documents
Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Dual Solenoid Gas Valve Installation

GM Series Dual-Block Multi-Function Gas Control Valves

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

GM-7000 Series CE Approved Gas Control Valve

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Safety. Operating instructions Bypass/pilot gas valve VBY 8 DANGER. Contents WARNING CAUTION Elster GmbH Edition 01.15

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

BGA158 Series CE Approved Class A Shutoff Gas Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

BGA158 Series CE Approved Class B Shutoff Gas Valve

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

G96 Series BASOTROL Dual Operator Valve

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

Safety. Operating instructions Magnetic relief valve VAN DANGER. Contents WARNING CAUTION. Changes to edition 11.11

VR400/VR800 SERIES. Honeywell CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION DESCRIPTION INSTRUCTION SHEET

VMR VMR-OTN VMR 6 bar

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

VR46.5V(A)/VR86.5V(A) SERIES

BGC258 Series BASOTROL Gas Valve

G92 Series BASOTROL Automatic Pilot Gas Valve

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Operating Instructions

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

4/2 way Pneumatic Solenoid Valve

VGF... VGH... Building Technologies Division Infrastructure & Cities Sector VGG... VGF... VGH...

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL Pressure Relief Device LPT

Operator: Save these instructions for future use!

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

VK41../VK81.. GAS CONTROLS FOR COMBINED VALVE AND IGNITION SYSTEM SPECIFICATIONS APPLICATION DESCRIPTION INSTRUCTION SHEET

Operator: Save these instructions for future use!

VRB00 Series CLASS B SERVO REGULATED COMBINATION VALVES

PSG 901. Pressure Switch for Gas. elektrogas.com EE141-07/12

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

828 NOVAMIX ENGLISH - ITALIANO - FRANCAIS - DEUTSCH - NEDERLANDS - ESKY

36H SERIES Combination Gas Valve

2-port seat valves PN25 with externally threaded connections

Tightness controls TC 1 3 and TC 4

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

VR400/VR800 SERIES. Honeywell CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK

Safety. Operating instructions Motorized valve for gas VK DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 06.

DWR6-205, DWR16-205, DWR6-206 Safety Pressure Limiters

Operator: Save these instructions for future use!

LNVx Gas Conversion Kit Instructions

Operating Instructions Part No

Installation, operating and maintenance Instructions for Seemag bypass level indicator

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

EVRM-NC EVRM-6NC. delta-elektrogas.com. Safety solenoid valves for gas Manual reset - Normally closed DN10 DN300.

SPECIFICATIONS CAPACITY

SPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION

Safety. Operating instructions Filter module VMF Measuring orifice VMO Fine-adjusting valve VMV DANGER. Contents WARNING CAUTION

SILENTAIRE TECHNOLOGY

C645A-E Pressure Switches

Installation and Operating Instructions Bypass Flow Meter DST

VR400/VR800 SERIES UNIVERSAL GAS VALVES CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK

Operating Instructions

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

2/2-Way Solenoid Control Valve

Types 749B and R130 Changeover Manifolds

Endura AZ40 Sensor assembly Smart electronics PCB

Installation, use and maintenance instructions. Gas burner (5)

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

VK8515M(R) MODULATING GAS CONTROL APPLICATION DESCRIPTION SPECIFICATIONS INSTRUCTION SHEET. Electrical data

Magnetic level switch type MR783 Instruction Manual

Engineering Data Sheet

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

VGD40.../VGD41... Double gas valves. Building Technologies Division Infrastructure & Cities Sector

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

SILENTAIRE TECHNOLOGY

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

Further technical information is available on

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

PROVENGAS AUTOMATIC PROVING SYSTEMS FOR GAS INSTALLATION

2-port and 3-port valves PN 16

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

Operating Instructions

Natural Gas to L.P. Gas Conversion Kit

VR8205S,T Direct Ignition Combination Gas Controls

Position switches FP series

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function Integrated bypass valve MB-ZRD(LE) B07

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

Natural Gas to L.P. Gas Conversion Kit

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Transcription:

EG15*... ERIE OLENOID G VLVE WITH 1/2 CONNECTION ND OPERTING PREURE UP TO 500 mbar DECRIPTION This series of solenoid gas valves are of normally closed type, suitable for civil and industrial applications, supplied with alternate or direct current and inclusive of a wire-net filter on the inlet to avoid the entrance of dirt of > 1 mm. Gas valves marked with or L after reference type have direct current supplied coil, which permitted to make actions as silent as possible. There is the possibility to have a fast opening or a slow opening valve (obtained by special hydraulic shockobsorber), with flow adjustment and fast opening initial flow adjustment and inlet and outlet pressure plugs. Gas valves of this series, conforming to EN161, have a CE type Certificate (CE Reg. N 63Q0626) in accordance to European Directives 90/396 and 93/68. EC- type certification in accordance with the new European Gas ppliances Regulation (EU) 2016/426 (GR); conformity to EC Low-voltage directive 2014/35/EU TECHNICL FETURE Class: Group: 2 upply voltage (1): 220-240Vac / 50-60Hz 110Vac / 50-60 Hz Operating temperature: -10 C / +60 C Closing time: 1s (all versions) Opening time: 1s (quick opening versions only) Mounting: vertical and horizontal Body: die-cast aluminium Core hitch: PG9 (1) Versions with different supply voltages are available. 2706_r04 1/5

DIRECTION FOR INTLLTION ND MINTENNCE This valve is a safety appliance and should not be modified. The manufacturer's responsibility and guarantee are invalidated in case the device is tampered with by the user. The applicable national regulation and European standards (Ex. EN 60335-1 and EN 60335-2-102) related to the electrical safety must be respected; ssemble the valve to the installation so that the arrow on the valve body has the same direction as the fuel flow. During the assembly of the valve to the installation piping, avoid twisting on the sheath and always use an hexagonal wrench to be fitted to the valve body. Make sure that no foreign matters have entered the valve body. Make sure that the max. fuel input pressure never exceeds the value appearing on the label. ll operations (installation, maintenance, etc.) must be carried out by a qualified technician. Before any connection operation, completely isolate the system from power supply (multi-pole disconnection). Place the system safely to avoid accidental switch-on and make sure there is no voltage. If the system is not switched off, there is a risk of electric shock. During and after any operation (installation, maintenance, etc.), make sure that the type and code are the ones provided, check the correct functioning and the internal and external thickness of the valve. In the event of a fall or impact, the valves must not be started, as safety functions may be compromised even if no damage is visible to the outside. Faulty valves or damaged must be unplugged from power supply and cannot be used. The valve has a designed lifetime* based on the endurance tests in the standard EN 161. summary of the conditions has been published by the European Control Manufacturers ssociation (fecor) (www.afecor.org). The designed lifetime is based on use of the valve according to the manufacturer s technical notes. fter reaching the designed lifetime in terms of the number of burner startup cycles, or the respective time of usage, the valve has to be replaced by authorized personnel. * The designed lifetime is not the warranty time specified in the Terms of Delivery. It is possible to connect two valves with two fixing brackets and an O-ring to guarantee the sealing. The whole system is blocked by two screws, as shown in Fig. 1. This method permits to avoid the onerous use of threaded junctions. Fig. 1 OLENOID VLVE WITH BY-P ll versions of EG25*... and EG30*... valves can be equipped with a by-pass valve (with orifice diameter 11 mm) directly fitted on the body. In this way it is avoided the installation of a separated by-pass valve. Both to the main valve and to the by-pass one, flow is given from the same inlet gas pipe, even if they have different electrical controls. By-pass valve can have fast opening, and can be with or without flow adjuster, but anyway inclusive of an inside rectification circuit, which permitted to use suitable attenuators, to make its actions as silent as possible. OLENOID VLVE CONNECTION 2/5 2706_r04

DIRECTION FOR EG15*L... VLVE DJUTMENT Flow adjustment for EG15*L... To adjust the gas flow, you have to remove one of the two screws used to fasten the lag group (the not enamelled one, marked with 4 in Fig. 2) and rotate clockwise the whole group to reduce the flow or in the opposite direction to increase it. Opening time adjustment fter removing the top protection, by rotating it counterclockwise, you have to act on the adjustment screw, marked with 1 in Fig. 2; by rotating clockwise, the opening time becomes longer, by rotating in the opposite direction, the opening time becomes shorter. Quick release initial flow adjustment fter removing the top protection by rotating it counterclockwise, if you rotate clockwise the nut marked with 2 in Fig. 2, the initial release will be reduced; if you rotate the same nut counterclockwise, the initial release will be increased. 4 2 1 3 Fig. 2 Fig. 3 DIRECTION FOR EG15*R... VLVE DJUTMENT Flow adjustment Rotate clockwise the screw marked with 1 in Fig. 3 to reduce the flow, rotate in the opposite direction to increase the same. 1 OVERLL DIMENION EG15**GMO EG15*P*3C EG15*L*GMO EG15*R*GMO EG15*L*GMO con BY-P CORPO VLVOL QUOT DI INTERE INGREO/UCIT EG15*R*GFD EG15*L*CFD 2706_r04 3/5

DIGRM PREURE DROP mbar FLOW RTE m 3 /h : tandard flow rate m 3 /h of NTURL G relative density 0.554 B : tandard flow rate m 3 /h of LPG relative density 1.54 C : tandard flow rate m 3 /h of TOWN G relative density 0.411 D : tandard flow rate m 3 /h of IR relative density 1 Operating pressure (mbar) Orifice diameter (mm) Connections UMMRY TBLE Weight (g) Coil Consumption (V) Consumption (V) Flow (m³/h gas with P2.5mbar) 220-240V 110v EG15* 0 500 15 G1/2" 820 BE6*3C 22 EG15* 0 500 15 G1/2" 850 BE6*FP 22 EG15* 0 500 15 G1/2" 852 BE6*FD 22 EG15* 0 500 15 G1/2" 866 BE6*C3C 22 EG15* 0 500 15 G1/2" 896 BE6*CFP 22 EG15* 0 500 15 G1/2" 898 BE6*CFD 22 EG15* 0 500 15 G1/2"" 9 BE6*G.. 22 EG15*R 0 500 15 G1/2" 864 BE6*C3C 22 EG15*R 0 500 15 G1/2" 894 BE6*CFP 22 EG15*R 0 500 15 G1/2" 896 BE6*CFD 22 EG15*R 0 500 15 G1/2" 916 BE6*G.. 22 EG15*L 0 250 15 G1/2" 1027 BE6*G.. 22 BY-P R 0 100 0 100 11 11 275 285 BE7*GMO BE7*GMOE 8 14 6 7 3.2 3.2 4/5 2706_r04

TYPE REFERENCE EG15 * R P * R D * G FD 8 P D 220/240-50/60 Opening (fast/slow) L Valve fitted with BY-P By-pass valve supply voltage and connections are the same of the main gas valve; therefore both GMO or both GFD. By-pass type R By-pass position D Fast opening valve. Fast, silent opening valve. low, silent opening valve (this version is inclusive of flow adjuster). Flow adjustment Valve fitted with equipment for flow adjustment. Pressure plug Valve inclusive of pressure plug G1/4 size. Fast opening. Fast opening with flow adjustment. Right Left upply voltage 110/50-60 110 Vac 50/60 Hz 220/240-50/60 220/240 Vac - 50/60 Hz Gas pressure switch position D Gas pressure switch type P PR Test pressure point position 5 Outlet left. 6 Outlet right. 7 Inlet left. 8 Inlet right. Connection type 2C 3C FP FD MO Winding type C G Right Left Fixed setting adjustable setting Connection with two core cable-ip65. Connection with three core cable-ip65. Connection with flat fast-on. Connection with fast-on for plug DIN43650-IP65.(GFD IP40) Connection with terminal board-ip40. upply in alternate current. upply in direct current. upply in alternate current, but valve operates in direct current thanks to an embodied rectification bridge. MO connection only. (For MO and FD connection versions only) NOTE FOR PRODUCT DIPOL The device contains electronic components and cannot therefore be disposed of as normal household waste. For the disposal procedure, please refer to the local rules in force for special waste. TTENTION --> Company Brahma.p.. declines any responsibility for any damage resulting from Customer tampering with the device. BRHM.p.. Via del Pontiere, 31 37045 Legnago (VR) - ITLY Tel. +39 0442 635211 - Fax +39 0442 25683 http://www.brahma.it E-mail : brahma@brahma.it 16/03/ ubject to amendments without notice 2706_r04 5/5