arxiv: v1 [physics.ins-det] 6 May 2016

Similar documents
Study of Mixed Gas Flow Pattern Inside RPC

Long term stability tests of INO RPC prototypes

arxiv: v1 [physics.ins-det] 16 Aug 2014

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

RPC CHARACTERIZATION AND TESTING ( by S. Mathimalar, INO Student)

arxiv: v1 [hep-ex] 18 Sep 2012

Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

The Resistive Plate Chamber detectors at the Large Hadron Collider experiments. Danube School, September 8-13, 2014 Novi Sad

Analysis of RPC Performance with Different Gas Mixture

arxiv: v1 [physics.ins-det] 4 May 2016

ATLAS RPC QA results at INFN Lecce

Assembly and Testing of RPCs in Pakistan. Hafeez Hoorani National Centre for Physics

Development of small, easy to build and low gas consumming timing RPCs

Yoke Instrumentation: ILD Muon System / Tail Catcher. Valeri Saveliev IAM, RAS, Russia DESY, Germany 3 June, 2016

A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers

Guideline for RMO Key comparison for Air kerma rate in 60 Co gamma radiation

PHENIX RPC in China. Xiaomei LI. Science and Technology on Nuclear Data Laboratory China Institute of Atomic Energy

Next Generation Quartz Pressure Gauges

Performance of a triple-gem detector for high rate charged particle triggering

WP2 Fire test for toxicity of fire effluents

Gas density monitor With integrated transmitter Model GDM-100-TI

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Detecting sound wave of bubbles produced in a boiling liquid

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

PERFORMANCE OF THE GAS GAIN MONITORING

MANUAL KPS Pressure Control Valve

Instrumentation & Data Acquisition Systems

Application Note AN-107

HumiSys HF High Flow RH Generator

TPC Report. D. Karlen T2K ND280m meeting December 7, 2004 Rome

On the possibilities for the readout of gas scintillation detectors for neutron scattering applications

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

GAS ANALYSIS AND MONITORING SYSTEMS

Development of high pressure-high vacuum-high conductance piston valve for gas-filled radiation detectors

EFFECTS OF OUTGASSING FROM SOME MATERIALS ON GAS CHAMBER AGEING

The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through the Muffler Combined With Valve Motion

Electrochemical Sensor

A Longterm Aging Study of the Honeycomb Drift Tubes of HERA-B Using a Circulated and Purified CF -Gas Mixture

NEW: CO2 incubator with sterilizable sensor

TECHNICAL SPECIFICATION

Effects of the electric field on the electron drift velocity in a double-gem detector in different gas mixtures

A high-sensitivity large volume cryogenic detector for radon in gas

WMO LABORATORY INTERCOMPARISON OF RAIN INTENSITY GAUGES

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer

This test shall be carried out on all vehicles equipped with open type traction batteries.

NEW: CO2 incubator with sterilizable sensor

CORESTA RECOMMENDED METHOD N 6

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Electrochemical Sensor

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Instructions in the Use of Radiation Protection. Equipment and Radiation Measuring Instruments by. Disaster Response Personnel in a Nuclear Emergency

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

Additives that prevent or reverse cathode aging in drift chambers with Helium-Isobutane gas *

UK Opportunities in SiD Calorimetry

MODEL GT820 OXYGEN SENSOR

Status update of Beam pipe. S. Tanaka KEK

Full-Vacuum Chlorinator C 2212 MB / 1

CO2 INCUBATOR CO2 INCUBATORS

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

PRODUCT SPECIFICATION. SFP+ Cage and Cage Assembly 1 of 8 A

AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER

FPG8601 Force Balanced Piston Gauge

The Radon Monitoring System in Daya Bay Reactor Neutrino Experiment

DELTI. Vac. DELTI-Vac MIL. Application. Principle. Characteristic

USER'S MANUAL HOT-WIRE TYPE GAS SENSOR NAP-100A SERIES ( NET10A(R) ) (For All Combustible Gases)

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Are Detonator Qualification and Lot Acceptance Test Requirements Rational?

130 SSP Soluble Salt Profiler

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

Ion-atom interactions in a gas jet - coupling of a gas catcher to a linear RFQ cooler

Assembly and measurements of a mechanical prototype of the BIS MDT chamber

Electrochemical Carbon Monoxide Gas Sensor (Model:ME3-CO) Manual. Version 1.2 Valid from May 1 st 2014

Recirculating Coolers

GasSense NDIR User Manual

The MINERνA Experiment

Customer Responsibilities

Do Not Print This Page.

Technical Data Sheet MF010-O-LC

Measurement of Representative Landfill Gas Migration Samples at Landfill Perimeters: A Case Study

The SPI Sputter Coater Handbook

MIL-STD-883G METHOD

ISO INTERNATIONAL STANDARD

Topics For Discussion Acadiana Gas Measurement School

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

Constant Pressure Inlet (CCN) Operator Manual

Vacuum System at IUAC

Accelerated Corrosion Test Chambers

Chapter I Standard application in photon dosimetry José Guilherme Pereira Peixoto Maria da Penha Potiens

KARL SUSS MJB3 UV400 Mask Aligner Standard Operating Procedure

Evaporator (DX) Freon Applications 1 12 Tons MHF

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Vibration Analysis and Test of Backup Roll in Temper Mill

PERFORM Operating Document

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

Characteristics and Production of Gas Sealed, Radiation Hard, Small Ionization Chambers

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

What I have learned about SF 6 gas testing.a Practical explanation

Transcription:

Preprint typeset in JINST style - HYPER VERSION Effect of water vapor on the performance of glass RPCs in avalanche mode operation arxiv:15.67v1 [physics.ins-det] 6 May 16 K. Raveendrababu a,d, P. K. Behera a, B. Satyanarayana b, S. Mukhopadhayay c and N. Majumdar c a Physics Department, Indian Institute of Technology Madras, Chennai 36, Tamil Nadu, India b Department of High Energy Physics, Tata Institute of Fundamental Research, Mumbai 5, India c Applied Nuclear Physics Division, Saha Institute of Nuclear Physics, 1/AF, Bidhan Nagar, Kolkata 764, India d Physical Science Division, Homi Bhabha National Institute, Anushaktinagar, Mumbai 94, India E-mail: raviramana@gmail.com ABSTRACT: We studied the effect of water vapor on the performance of glass Resistive Plate Chambers (RPCs) in the avalanche mode operation. Controlled and calibrated amount of water vapor was added to the RPC gas mixture that has C H F 4 as the major component. The deterioration in the performance of RPC was observed while operating with wet gas and recovered after switching to standard gas. KEYWORDS: Particle tracking detectors (Gaseous detectors), Resistive plate chambers; Large detector systems for particle and astroparticle physics.

Contents 1. Introduction 1. Experimental setup 3. Measurements and observations 3.1 Standard gas studies 3. Wet gas studies 3 3.3 Recovery studies 5 4. Conclusions 5 5. Acknowledgements 6 1. Introduction The India-based Neutrino Observatory (INO) collaboration has proposed to build a kiloton magnetized Iron Calorimeter (ICAL) to precisely measure the atmospheric neutrino oscillation parameters. The collaboration has chosen m size glass Resistive Plate Chambers (RPCs) as the active detector elements and is going to deploy 8, of them in the ICAL detector [1]. The RPCs will be operated in the avalanche mode with an optimized gas mixture of C H F 4 /iso- C 4 H /SF 6 = 95./4.5/.3 []. The experiment is expected to run for more than years in order to record statistically significant number of neutrino interactions for the confirmation of atmospheric neutrino oscillation. Therefore, long term stability and performance of the RPCs over the duration of the experiment is of prime concern. About, liters of gas is going to be circulating in the RPCs during the experiment. The gas lines running into about 135km in total are going to supply/receive gas to/from the RPC detectors. In spite of stringent QC during the RPC gas gap making or gas lines plumbing, it is impossible to prevent ambient air or water vapor entering into the gas circuit over these long periods of time. The contaminants are known cause for serious degradation in the performance or permanent damage of the RPCs [3, 4, 5]. Considering the severe repercussions in the mammoth ICAL detector, a systematic study of this problem was undertaken. Two glass RPCs of cm size were fabricated and were simultaneously operated with standard gas mixture in one and with gas mixture along with controlled and calibrated amount of water vapor in the other. A common cosmic ray muon telescope was set up for studying both the RPCs. Ambient parameters such as temperature and relative humidity (RH) as well as RPCs operating and performance parameters such as currents, efficiencies, singles rates, signal charges and time resolutions for cosmic ray muon detection were systematically recorded throughout the experiment. It was observed significant deterioration in the performance of RPC in which gas with water vapor was flown. 1

. Experimental setup The RPCs of cm size were fabricated using 3 mm thick float glass plates. The outer surfaces of the glass plates were coated with specially developed conductive graphite paint for the ICAL RPCs, which facilitates applying high voltage across the electrodes [6, 7]. Readout strips of.8 cm width were orthogonally mounted on the external surfaces of the RPCs by keeping. cm gap between the consecutive strips. The electrode and the readout strip are separated using a layer of mylar insulator. A telescope was set up with three plastic scintillation counters to get a 3-fold (3F) coincidence for atmospheric muons. The dimensions of scintillation counters in length width thickness are cm cm 1 cm (top), cm 3 cm 1 cm (middle), and cm 5 cm 1 cm (bottom). The block diagram of a stack of two RPCs and three telescope counters, and the electronic circuit setup is shown in Figure 1. An optimized gas mixture of C H F 4 / iso-c 4 H /SF 6 = 95/4.5/.5 was flown through the RPCs using polyurethane tubes. The block diagram of the gas flow system is shown in Figure. Figure 1. Block diagram of the experimental setup developed for the studies. 3. Measurements and observations 3.1 Standard gas studies The RPCs were operated with the standard gas at SCCM rate and their currents, efficiencies and singles rates as a function of applied voltage were measured. The measured efficiencies of

Figure. Block diagram of the gas flow system. and as a function of applied voltage are shown in Figure 3. The detectors showed more than 95% efficiency on the plateau. The measured signal charges and time resolutions of the detectors are shown in Figure 4. The signal charges of and are.99 pc and 1.4 pc, and the time resolutions are.8 ns and.3 ns, respectively. 9 7 11 11.5 1 1.5 13 13.5 Voltage (kv) Figure 3. Efficiencies of and as a function of applied voltage. Long-term stability studies: Then, the RPCs were operated at 1. kv and monitored their performances for 3 days. The efficiencies, singles rates and leakage currents of the detectors for this time period are shown in Figure 5. Their performances were stable throughout the period. 3. Wet gas studies The water vapor was started adding into via the gas mixture using a water bubbler as shown in Figure. The amount of water vapor added to the detector was measured in a controlled way using RH sensor and is shown in Figure 6. Throughout these studies, was continued with the 3

_Standard_Gas Entries 54 Mean 1.893 RMS 1.413 9.63 / 61 Constant. ± 14.5 MPV.988 ±.314 Sigma.377 ±.17 1 3 4 5 6 7 8 9 Charge (pc) _Standard_Gas Entries 33 Mean 5.67 RMS.83 χ / ndf 65.43 / 49 Constant 41.77 ± 1.7 Mean 5.73 ±.9 Sigma.8 ±.1 45 55 65 7 (c) Time (ns) 7 _Standard_Gas Entries 54 Mean 1.81 RMS.969 99.64 / 57 Constant 358.4 ± 17.6 MPV 1.41 ±. Sigma.854 ±.115 1 3 4 5 6 7 8 9 Charge (pc) _Standard_Gas Entries 33 Mean 5.1 RMS.46 1.8 / 5 Sigma.33 ±.75 45 55 65 Time (ns) (d) Constant 37.43 ± 1.71 Mean 5.3 ±.9 Figure 4. Signal charges: and, and time resolutions: (c) and (d) of and, respectively, with standard gas operation at 1. kv. 98 96 94 9 9 Singles rate (Hz) Current (na) 36 34 3 8 6 4 88 86 5 15 5 Day 5 15 5 Day 18 16 5 15 5 Day (c) Figure 5. Efficiencies, singles rates and (c) currents of both the RPCs with standard gas operation for 3 days. standard gas flow itself and was a reference detector. Then, the performances of both the detectors were monitored continuously. With the wet gas operation for a few days, the efficiency and singles rate of degraded to % and 1 Hz, respectively. The currents drawn by the detector increased gradually with time. The efficiency, singles rate and current drawn by the during the wet gas operation in comparison to operated with the standard gas is shown in Figure 7. Signal charge: The signal charge of became smaller (.36 pc) with the wet gas operation, whereas that of with standard gas operation (1.19 pc) remained similar to its measured value shown in Figure 4b (1.4 pc). The signal charge distributions of with wet gas and with standard gas operations are shown in Figures 8a and 8b, respectively. 4

W e t g a s R H (% ) 6 5 5 5 4 5 4 3 5 3 5 1 5 1 5 1 S C C M 3 S C C M 4 6 8 1 T im e (m ) Figure 6. The quantity of water vapor addition to the for SCCM and SCCM gas flow rates. 1 1 1 Time (h) Singles rate (Hz) 1 1 1 Time (h) Current (na) 1 1 1 1 Time (h) (c) Figure 7. The efficiencies, singles rates and (c) currents of with the wet gas operation, and that of with the standard gas operation. Time resolution: The timing distribution of with the wet gas operation got deteriorated as shown in Figure 8c. Whereas, that of with standard gas operation (1.9 ns) remained similar to its measured value shown in Figure 4d (.3 ns). 3.3 Recovery studies was operated with wet gas at various flow rates and the deterioration in the detector s efficiency was observed as a function of time. It was observed that higher the flow rate, faster the deterioration as shown in Figure 9a. The detector was operated with wet gas at % efficiency for a day and then switched to standard gas. Then, the efficiency of detector recovered to more than 95% as shown in Figure 9b. 4. Conclusions The effect of water vapor on the performance of glass RPC was studied. We used optimized gas mixture C H F 4 /iso-c 4 H / SF 6 = 95/4.5/.5 to operate the RPC in the avalanche mode. The detector showed more than 95% efficiency with the standard gas operation, its signal charge and time resolutions were.99 pc and.8 ns, respectively. Then, we started adding water vapor into 5

_Wet_Gas Entries 899 Mean 1.47 RMS 1.97 68.73 / 51 Constant 91.9 ± 19.5 MPV.361 ±.896 Sigma.3738 ±.199 _Standard_Gas Entries 899 Mean 1.647 RMS.88 154.7 / 47 Constant 35.9 ± 19.8 MPV 1.19 ±. Sigma.56 ±.4 1 3 4 5 6 7 8 9 Charge (pc) _Wet_Gas Entries 899 Mean 51.8 RMS 4.168 41.4 / 63 Constant 18.37 ±.9 Mean.48 ±.1 Sigma 4.6 ±.1 35 45 55 65 (c) Time (ns) 1 3 4 5 6 7 8 9 Charge (pc) _Standard_Gas Entries 899 Mean 5.9 RMS.4 133.4 / 64 Constant 6.3 ± 1.35 Mean 5.6 ±.8 Sigma 1.877 ±.74 44 46 48 5 54 56 58 (d) Time (ns) Figure 8. Signal charge of: with the wet gas operation and with the standard gas operation, and time resolution of: (c) with the wet gas operation and (d) with the standard gas operation. SCCM SCCM SCCM SCCM 95 9 85 75 7 SCCM SCCM SCCM SCCM 5 15 5 35 Time (h) 1 Time (m) Figure 9. The deterioration in efficiency of with wet gas operation at various flow rates and its recovery with standard gas operation. the RPC. The detector s efficiency deteriorated to % after a few days of operation with wet gas. Its signal charge became.36 pc and timing distribution got deteriorated. The RPC was operated at % efficiency with wet gas for a day and then switched to standard gas. The detector s efficiency recovered to more than 95%. 5. Acknowledgements This work was supported by the Department of Atomic Energy (DAE), and the Department of Science and Technology (DST), Government of India. The authors would like to gratefully acknowledge the help of their colleagues V. Asgolkar, S. Chavan, R. R. Shinde, P. Verma, S. D. Kalmani and L. V. Reddy at TIFR, Mumbai, and V. Janarthanam and Jafar Sadiq at IIT Madras. K. 6

Raveendrababu expresses gratitude to P. Fonte of LIP, Coimbra for useful discussions during the 6 workshop. References [1] Shakeel Ahmed et al., Physics Potential of the ICAL detector at the India-based Neutrino Observatory (INO), arxiv:15.73v1. [] M. Salim et al., Experimental and numerical studies on the effect of SF 6 in a glass RPC, 1 JINST 7 P119. [3] H. Sakai et al., Study of the effect of water vapor on a resistive plate chamber with glass electrodes, Nucl. Instrum. and Meth. A 484 () 153-161. [4] T. Kubo et al., Study of the effect of water vapor on a glass RPC with and without freon, Nucl. Instrum. and Meth. A 8 (3) -55. [5] A. Candela et al., Ageing and recovering of glass RPC, Nucl. Instrum. and Meth. A 533 (4) 116-1. [6] R. Santonico and R. Cardarelli, Development of Resistive Plate Counters, Nucl. Instrum. and Meth. 187 (1981) 377-3. [7] M. Bhuyan et al., Development of m m size glass RPCs for INO, Nucl. Instrum. and Meth. A 661 (1) S64-S67. 7