Feltest AirSpeed/2 Instruction manual

Similar documents
Instruction Manual EMA 84 Digital Pressure Gauge

Digital pressure gauge Model CPG500

Hand-held pressure calibrator with integrated pump Model CPH6600

[Instruments for vacuum measurement, checking and adjustment] 3

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Precision pressure sensor Basic version Model CPT6020

Integral type Differential pressure flowmeter VNT Series

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Precision digital pressure gauge Model CPG1000

High-performance submersible pressure transmitter For level measurement Model LH-10

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Digital pressure gauge Model CPG500

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Datasheet: K-30 ASCII Sensor

PM105 PRESSURE METER USER S MANUAL

Mod. M M M063..

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

High-performance submersible pressure transmitter For level measurement Model LH-10

Instruction Manual Contact Pressure Vacuum Gauge

EC214 EC215 - EC215R Bench Conductivity Meters

MANUAL KPS Pressure Control Valve

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

Types and approvals. Page 1/6. Data Sheet

Instruction Manual BA90 Precision Barometer

Technical Data Sheet MF010-O-LC

OXY 3690 MP. Measuring transducer for air oxygen

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Gas density monitor With integrated transmitter Model GDM-100-TI

Pneumator. Testo Industrial Services More assurance, better service. Pressure calibrator and measuring instrument.

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

OC Panel High Limit Aquastat Kit, Manual Reset p/n

INTRODUCTION TO NETWORK WIND 3 MOUNTING THE UNIT 14 SELECTING THE DISPLAY MODE 5 ABBREVIATIONS AND DEFINITIONS 17

Selecting the right pressure sensor for your application

METROTEC GSM. Type GSM. Oxygen measurement and control unit. *** Version 1.6 ***

Operating Manual VSA100A. tina29e1 ( )

FTC130 Transmitter. Operating Manual

AMS 6916 Board mount pressure sensor with ratiometric analog output

DTG - LCD Digital Temperature Gauge USER MANUAL

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

STAGE, STADIUM & X-TREME SHOT.

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Optical Dissolved Oxygen Meter

Battery Powered Thermal Mass Flow Meters for Gases

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

GasSense NDIR User Manual

LUGB Vortex Flowmeter

G4S G4A1KY RESIDENTIAL CONVERSION KIT LOW PRESSURE CONVERSION KIT MEDIUM PRESSURE CONVERSION KIT HIGH PRESSURE CONVERSION KIT ULTRASONIC GAS METER

Digitale manometers. TYPE: ETD-01, klasse 0.5. Specificaties HOOFDSTUK 6

American Weigh Scales, Inc. LB User Manual

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Technical Data. Dimensions

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference!

DPC-30 DPC-100. Reference Manual

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

COSMO INSTRUMENTS CO., LTD.

red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

OPERATION MANUAL BFX-2

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

Installation and Operation Manual

SAUTER FK Version /2016 GB

How to specify a product. Process Sensors and Mechanical Instruments

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

DPS-400 SERIES DPH-100 SERIES

Heavy Duty Dissolved Oxygen Meter

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

MODEL GT820 OXYGEN SENSOR

PS-425 Pitot-Static/Air Data Tester

DFX II Series. Digital Force Gauge

Precision hand-held pressure indicator Model CPH6400

FAS-W. Features. Applications. Automatic condensation hygrometer

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

Proportional pressure regulators VPPE

Digital deadweight tester Model CPD8500

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

Optical Dissolved Oxygen Meter

We measure it. For gas and water installers. testo hpa. bar

Coriolis Mass Flow Meter

Elcometer ISO Groove Depth Checker. Operating Instructions

Technical Data. Dimensions

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

Transcription:

Feltest AirSpeed/2 Instruction manual

2

1. Table of contents 3 2. Safety instructions 4 2.1 Intended use 4 2.2 Safety precautions 4 3. About the instrument 6 3.1 Names of parts 6 3.2 Working principle 7 4. The measurement 7 4.1 Measuring procedure 7 4.2 Interpretation of the results 9 5. Technical data 10 6. Declaration of conformity 11 3

2. Safety instructions 2.1 Intended use The Feltest AirSpeed/2 is intended to measure the airflow through a press felt over an Uhle box on running paper machines. The instrument may not to be used on any other object, like for example dryer screens or conveyor belts. 2.2 Safety precautions Running paper machines can be very dangerous! Therefore it is very important to read this manual and its safety instructions before operating the Feltest AirSpeed/2. Before using the instrument, read this manual carefully, it contains important safety information. If you not fully understand this manual, please contact Feltest Equipment bv for more information. Keep this manual where the operator can easily find it. Use the instrument as intended and according to this manual. Do not measure the airflow through forming fabrics or dryer fabrics on running paper machines. Be aware of the danger of rotating machine parts. Do not make measurements close to in-going nips. You or the instrument could be grabbed into the machine, which can result in severe life threatening injuries and very costly damages. Do not measure press felts with holes or damaged edges. Before starting your measurements, check with the staff of the paper machine if holes or damaged edges are known. At the machine, first look very carefully for any defects or signs indicating defects, before starting the measurement. If you have any doubt, do not measure. 4

BAT0.00 0 5 10 15 20 25 30 Before starting a measurement, make sure you find a stabile position with two feet on a solid base. Do not bend over into the machine. If you must lean against a safety fence (or something similar), first check its stability. Always follow the safety instructions that apply for the location where the measurements are done. Do not ignore or remove safety constructions from the paper machine. Please note: Doing measurements (of any kind) on running paper machines is dangerous and requires alertness, concentration and common sense. The Feltest instruments are designed and constructed to be as save as possible for their intended use. Nevertheless it is the user's responsibility to actually use the instrument in a safe way. Feltest Equipment bv can not be held responsible or liable in any way for suffered injuries or damages that occurred while using their instruments. 5

3. About the instrument With this air speed meter (or anemometer) you have acquired a precision instrument of exceptional quality. You also obtain the benefit of our many years experience in measuring physical data on running paper machine clothing. All probes have been calibrated in a wind tunnel and are checked to conform to the required tolerances. 3.1 Names of parts The instrument is built up out of an electronic read out unit, a probe with a small propeller that is installed in a plastic measuring head and a telescopic grip. The air flow is measured by a small, aerodynamically optimised propeller which is extremely accurate and reliable. The plastic measuring head is made from HDPE which ensures low friction with the felt. Contamination will not stick to the material, therefore it can be cleaned easily. Average, minimum and maximum values can be called up at any time. As the calculation of these values takes place simultaneously they can be requested at any time, the test result is not affected. 6

3.2 Working principle The Feltest AirSpeed/2 works with a vane or propeller anemometer as the propeller has proofed to be more accurate and durable than a thermal anemometer in the harsh environment of a paper machine. The propeller speed, directly corresponding to the flow rate, is sensed electronically without inducing any reaction force and is transmitted to the read out unit. The read-out unit operates through a microprocessor with a minimum current loading. This makes it possible to perform all functions and measurements by using only a few keys and allows the data to be called up at any time. The measuring data are read on the LCD display. The unit is battery operated. 4. The measurement It is of utmost importance to work safely when measuring the air speed through a press felt. Find a safe and stable position close to the Uhle box, expand the telescopic grip so it will not be necessary to bend over into the machine but most important is to stay away from any in-going nip! 4.1 Measuring procedure Preparation The connector and cable of the probe are led through the telescopic grip. Then the measuring head and the telescopic grip can be mounted together. The connector is clicked into the read out unit (watch the red dots) and the instrument can be switched on with the On/Off key. The instrument performs a functional test lasting about 2 seconds. During this time the display shows the probe code 15.20. The first 2 digits indicate the propeller head diameter, the last 2 digits the fullscale reading in m/s. The instrument now measures continuously and shows the average value of the last 2 seconds on the display. The display is refreshed every 0,5 second. Changeover to 6 or 22 seconds average: press the 7

Fast or Slow key. To return to the 2-second average the instrument must be switched off and on again. Error indication If the display shows E.xx when switching on or during operation, this indicates a fault. The fault can be identified from the E-number details under Technical Data in chapter 5. Measurement When it is safe to measure the air speed, the measuring head is held against the felt, above the slit of the Uhle box. The slit in the measuring head should be in contact with the felt, the round hole should be on top. By rotating the measuring head a few degrees clockwise and counter clockwise one will see that the measured air flow will vary. There is no rule of thumb for the right angle; it depends on felt weight and water content, felt speed, width of the slit and the force with which the measuring head is pressed onto the felt. Generally spoken the position which gives the highest test results is the best. After switching on the instrument, averages are calculated over 2 seconds (every 0,5 second a value). Pressing the Min/Max key will return the minimum and maximum test results measured. Pressing the Flow key will return to the current test values. Where greater accuracy is required and the flow is rather irregular the test time can be extended, resulting in an average over 6 seconds (press the Fast key) or 22 seconds (press the Slow key). During the measurement the remaining test time up to the end is indicated in seconds. The Mean or average value of the complete measuring cycle will be calculated when the measuring time has ended. A new measurement is started by pressing the Fast or Slow key again. To return to the 2 second average, the instrument needs to be switched off and on again. When the display shows BATT the battery (9 Volt) has to be replaced. 8

4.2 Interpretation of the results By measuring the air speed through a press felt it becomes possible to quantify the felt s permeability or openness. Generally the measured air speed should be between roughly 2 and 10 m/s. If the test results are too low, the Uhle box will hardly remove any water out of the press felt and values over 10 m/s will only cost vacuum without increasing the amount of removed water. Still, only measuring the air speed is not enough to determine the felt s condition. The applied vacuum is very important and should be measured as well (for example with the Feltest RealVac) as manometers on Uhle boxes are seldom reliable. To compare the permeability from several measurements over time with different levels of vacuum, one could calculate a relative dynamic permeability. This means to measure both vacuum and air speed and then calculating the air speed towards a standard vacuum of 10kPa. An example: Measured Measured air speed Dynamic Perm vacuum @ 10 kpa 20 kpa 4.0 m/s 2.0 m/s 30 kpa 4.0 m/s 1.3 m/s 35 kpa 4.0 m/s 1.1 m/s This examples makes clear that, although the measured air speed is always 4.0 m/s, the felt becomes more closed as the applied vacuum is increasing. If the air flow through a felt decreases, this can be the result of contamination or compaction of the felt. Also a high water content in the felt will reduce the air flow over the Uhle box. Only by also measuring the caliper with a Feltest Caliper Gauge and the water content, one gets the whole picture and is it possible to accurately determine the felts condition. 9

5. Technical data Probe Medium: non-corrosive gases Measuring range: 0,5 to 20 m/s Start-up code: 15.20 Connector: Lemo FCG.0B.305.CLCD52Z Accuracy: 2,0% full scale plus 5% reading Operating temperature: 0 to +120 C Storage temperature: 65 to +150 C Read out unit Medium: non-corrosive gases Unit of meas.: flow in m/s Display: LCD 4 characters Measuring rate: 2 values/sec. Supply: Battery (1 x 9 Volt, size PP3) Current consumption: approx. 15 ma Battery life: approx. 12 hours Case dimensions: 80x145x39 mm (ABS plastic) Case protection: IP64 (splash water proof) Weight: 230 g Operating temperature: 0 to + 50 C Storage temperature: -30 to + 80 C Air humidity: 0 to 90% rh, non condensing Standard: laser controlled wind tunnel (Certificate in accordance with EN 45001) Error diagnosis E.01 = probe type not recognised E.03 = over velocity measuring range 10

6. Declaration of conformity Instrument: Instrument type: Type designation: MiniAir Junior Vane anemometer V7 The signing legal authorities state, that the above mentioned equipment meets the requirements of the electromagnetic compatibility (EMC) according to the Guideline of Counsel 89/336/EEC of 03.05.1989 The evaluation procedure of conformity was assured according to the following standards: a) Emission : EN 55022 : 1994 b) Immunity : EN 50082-1 : 1992 This EC Declaration of conformity is based on the test report No. 95.1 10951 of the EMC-Testcenter of SEV/ASE, CH-8320 Fehraltorf. Signed on January 1st 1996, M.F. Lensvelt Managing Director Postal address: Visiting address: Feltest Equipment BV Feltest Equipment BV Postbus 205 Bijenkorf 55 NL-6960 AE Eerbeek NL-6961 PA Eerbeek The Netherlands The Netherlands 11

P.O. Box 205 NL 6960 AE Eerbeek The Netherlands T: +31 313 652 215 F: +31 313 654 068 E: info@feltest.com W: www.feltest.com