Topics For Discussion Acadiana Gas Measurement School

Similar documents
American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

American Weigh Scales, Inc. LB User Manual

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

Generating Calibration Gas Standards

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

This test shall be carried out on all vehicles equipped with open type traction batteries.

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Instruction Bulletin Addendum For Pressure-Balanced In Situ Oxygen Probes

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

GPR-1500 PPM Oxygen Transmitter

Protocol Gas Verification For Compressed Gas Cylinders Containing Either SO 2, NO or CO. Quality Assurance Plan/Standard Operating Procedure

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Improve Process Reliability

Moisture Image Series 1. Service Manual

GPR-1500 GB Glove Box PPM Oxygen Transmitter

Agilent Flowmeter ADM1000

OXYGEN MONITORING SYSTEM OMS

BGA244 Binary Gas Analyzer

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

Flow meter. bellow vaporizer. APL valve. Scavenging system

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

Best Practice for Calibrating LTH Conductivity Instruments

CHAPTER 3 RESULTS AND DISCUSSION

Air Monitoring Directive Chapter 7: Calibration

GPR-2500 / GPR-2500MO Oxygen Transmitter

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

Measuring the Conductivity of Pure Water Using USP<645>

MODEL GENERA PURGE TURBINE INSTR DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Moisture Monitor Series 3. Service Manual

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

ACV-10 Automatic Control Valve

DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

TECHNICAL BULLETIN. TriControls. Control Materials for Liquid QC and Calibration Verification

RAM 4021-DPX Operation Manual

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Title: Standard Operating Procedure for Sabio 2010 and 4010 Dilution Calibrator

Calcimeter Instruction Manual

Constant Pressure Inlet (CCN) Operator Manual

MODEL GT820 OXYGEN SENSOR

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Orifice Plate Flow Meter

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Rosemount 140/141/142

Model Series 62 Constant Differential Relay

5000TOC Sensor Standard Operating Procedure for TOC Calibration Conductivity Calibration Temperature Calibration Flow Rate Calibration

AMT-Ex Dewpoint Transmitter

Columbus Instruments

OPERATING INSTRUCTIONS FOR MODEL

Quick Installation Guide Doc nr.: C Date:

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

RCD - Ultra-Rugged Differential Pressure Flowmeter

DTG - LCD Digital Temperature Gauge USER MANUAL

Model DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual

GPR-2800 IS Oxygen Transmitter

PS-525 Pitot-Static/Air Data Tester. OPERATION AND MAINTENANCE MANUAL For Models PS-525 and PS-525A

Oxygen Flue Gas Analyzer BA 2000

Operation Manual. Pro CO. Carbon Monoxide Analyzer. Rev

Technical Data Sheet MF010-O-LC

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

Aurora. Moisture Measurement for Industrial Gases. GE Measurement & Control

MMS Mercury Monitoring System for Natural Gas

Considerations for Sampling Wet, High Pressure, and Supercritical Natural Gas. Presented by: Shannon M. Bromley

Instruction Manual MicroChem 2 Chlorine Probes Series CL4000

ZIRCONIA OXYGEN DETECTOR SERVICE MANUAL

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

Model B Wire Wet Oxidant Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

with O 2 Controller Instruction Manual

HLM-2000-TX Gas Transmitter User Manual

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Sensoric 4-20 ma Transmitter Board Operation Manual

GILMONT ACCUCAL FLOWMETERS

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

Non-Membrane Disinfection Sensors Instruction Manual

Instruction Manual. Model DSP-Ex Portable Dewpoint Meter. Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

8.1 Calibration of gas sensors

Maintenance of the Electronic ( EPC ) Pressure Controllers on GCs

Oxygen Dialflow Meter. Instructions for Use

Refillable ORP/Redox Probe: Model MTC30101 or MTC30103

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

KING-GAGE. Calibration Instruction Manual. D/P LiquiSeal Purge Control and D/P Purge Control

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Malema Sensors M-2700 Integrated Ultrasonic Flow Meter

Overview. Front Panel: Keypad and Display

DPC-30 DPC-100. Reference Manual

PS-425 Pitot-Static/Air Data Tester

Simrad GD10P Extended On-site Maintenance

VIC offers a variety of Calibrated Gas Leaks

Air Check Lite Toxic Gas Monitor

Electrochemical Sensor

Navigator 600 Silica analyzers

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

Transcription:

1) Principle of Operation The Electrolytic Principle How the cell works 2) Electronic Verification Basic field check procedure Cell simulation 3) Flow Calibration Topics For Discussion Acadiana Gas Measurement School 4) General Troubleshooting Leak check Delta flow procedure Cell test

Electronic and Flow Test Procedures For MEECO Standard Industrial and Natural Gas Moisture Analyzers ISO 9000 Calibration Verification 1 PURPOSE The following procedure determines whether the moisture analyzer indicates the correct moisture readings in relation to the electrolysis current from the cell. To perform the verification tests, you will need the soap bubble burette supplied with your analyzer or the MEECO Veriflow electronic soap bubble flowmeter (P/N F2100), a decade box or multi-turn potentionmeter and a 4 ½ digit ammeter with at least 3 decimal place resolution. 2 PROCEDURE 2.1 Units should be returned to the factory every 12 months for recertification. MEECO field services is an acceptable alternative. 2.2 In the interim, users may choose to perform the following Electrical Calibration Check and Flow Meter Calibration every six months. 3 ELECTRICAL CALIBRATION CHECK 3.1 With the Power Off, disconnect the cell leads from the electrolytic cell. Follow procedures as indicated in the analyzer instruction manual. CAUTION: Do not allow the cell leads to make contact with the chassis or ground, otherwise the cell fuse will be blown. 3.2 Connect the decade resistor box or potentiometer and the ammeter in series with the cell leads. 3.3 Set the decade box or potentiometer resistance to the maximum value. 3.4 Turn the analyzer power on. 3.5 Adjust decade resistor box or multi-turn potentiometer to a value for a current reading on the ammeter within the range of your particular instrument, as shown below: Calibration Verification Values (ppm unite): Analyzer Display Ammeter Reading 1.000 ppm 13.1415 ua 10.00 ppm 131.415 ua 100.0 ppm 1.31415 ma 1000 ppm 13.1415 ma

Calibration Verification Values (lbs/mmscf unite): Analyzer Display Ammeter Reading 100 lbs/mmscf 28.300 ma 50 lbs/mmscf 14.150 ma 20 lbs/mmscf 5.660 ma 10 lbs/mmscf 2.830 ma 5 lbs/mmscf 1.415 ma 1 lbs/mmscf 0.283 ma 3.6 If the readings are within ± 1 of the least significant indicated value on the display meter, the calibration is satisfactory. If this is not the case, contact MEECO s Service Manager. Note: Use of non-compliant test equipment can produce erroneous results. 4 FLOW CALIBRATION PROCEDURE AT STANDARD TEMPERATURE AND PRESSURE 4.1 Power up the analyzer and connect to a gas source. 4.2 Make sure that the inside of the soap bubble burette is clean. To clean the burette, use warm water and rinse out all traces of soap. 4.3 Wet the inside of the burette with water, making sure to shake out any excess water. 4.4 Connect the flexible tube from the burette to the sample outlet of the analyzer. 4.5 Put one or tow drops of soap solution in the top of the burette and allow it to slide down the inside glass surface. 4.6 Adjust the sample flow indicator on your analyzer to the approximate 100 sccm setting for your sample gas. Note: for 10 sccm sample flow units, adjust flow to the approximate 10 sccm setting for your sample gas. 4.7 Depending upon the style of your burette, gently squeeze the bulb at the base of the burette or lightly pinch the tube until a single bubble forms and starts moving through the glass tube. Note: You may need to form several bubbles before one bubble will travel through the entire length of the glass tube. 4.8 Select a single bubble and time its passage from the 0 to the 100 or 10 marking on the burette, depending on the model of your analyzer. 4.9 Once you have timed the bubble, calculate the actual flowrate using the following formula. Flow in sccm = 60 seconds x 100 cc/actual time 4.10 Adjust the sample flowrate on your analyzer until the time of passage is 60 seconds.

4.11 Make a permanent note of the flowmeter ball position for the specific gas tested. You will need to adjust your sample flow indicator to this position each time you run this gas. 4.12 Repeat this procedure for any other gases you will test with this analyzer.

DELTA FLOW PROCEDURE A delta flow check is very useful to determine the unit s correct functioning while on-line. This feature verifies the cell s operation in accordance with Faraday s Law, which is absolute. Hence, there is no need for calibration versus an external moisture standard. The delta flow, while a test of the sensor s correct operation, is not a true test of the moisture in the sample unless all residual moisture or sources of moisture are eliminated from the sampling system from the test point to the sensor. This is because. As with any moisture analyzer or transmitter, the unit has not way of distinguishing between the moisture coming from a leak or a wet regulator and the true moisture in the sample - thus the importance of a high-integrity, leak-free sampling system. Normal Delta Flow Procedure: Using a delta flow, the actual amount of water vapor flowing through the electrolytic sensor is reduced to half by lowering the sample flow rate from 100 sccm to 50 sccm. The instrument should respond by displaying a reading approximately half of that which is displayed before the flow reduction. Note that the water vapor concentration of the sample gas must remain constant during the time of this test for the result to be meaningful. It is also important to insure the readings have stabilized before recording them. This procedure is as follows: 1. Let the unit equilibrate. 2. Record the readout of moisture at the 100 sccm flow rate. 3. Change the flow rate to 50 sccm. 4. Let the unit equilibrate. 5. Record the readout of moisture at 50 sccm flow rate. 6. Subtract the recorded 50 sccm readout from the 100 sccm readout. 7. Multiply the difference by a factor of two. 8. If the result is within the specified accuracy of the analyzer in relation to the reading in step #2, you have confirmation of the instrument s proper functioning. H If there is a large deviation, there is an instrument malfunction. Most likely the cell is contaminated. If the sampling system is new and drying down, the moisture purged from wet components changes as the components dry. Therefore, the moisture in the gas entering the transmitter through the sampling system changes. A delta flow performed under these conditions will, of course, yield incorrect results, because the actual moisture in the sample is changing as the delta flow is being performed. Often, after some period of purging, moisture from wet components or moisture from a small leak may be insignificant relative to the total moisture measurement on the

transmitter. In terms of your moisture specification, the possibility that a small leak is adding moisture to the measured sample may not be important as long as the measurement is within specification.