Hydraulic Evaluation of the Flow over Polyhedral Morning Glory Spillways

Similar documents
IMPACT OF MAKING THE CREST OF WEIR MULTIFACETED ON DISCHARGE COEFFICIENT OF MORNING GLORY SPILLWAY

Impact of anti-vortex blade position on discharge experimental study on the coefficient of morning glory spillway

Discharge Coefficient in the Morning Glory Spillways due to Longitudinal Angles of Vortex Breakers

Discharge Coefficient in Siphon Spillway with Different Cross Sections

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models

DESIGN OF BELL-MOUTH SPILLWAY AT BARVI DAM

Investigation of Cavitation Damage Levels on Spillways

Computerized Simulation Hydraulic Behavior of Shaft Spill way with vortex breaker on crest & Semi long stepped chamber throat

3D NUMERICAL MODELLING OF THE CAPACITY FOR A PARTIALLY PRESSURIZED SPILLWAY

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 1, 2012

Hours / 100 Marks Seat No.

Evaluation of step s slope on energy dissipation in stepped spillway

Free Surface Flow Simulation with ACUSIM in the Water Industry

Evaluating the Spillway Capacity of the Morning Glory Spillway at Harriman Dam

Broadly speaking, there are four different types of structures, each with its own particular function:

Bioreactor System ERT 314. Sidang /2011

Hours / 100 Marks Seat No.

Experiment 8: Minor Losses

Experiment (13): Flow channel

Cooling performance of Persian wind towers

DAIVÕES DAM SPILLWAY: A NOVEL SOLUTION FOR THE STILLING BASIN

COEFFICIENT OF DISCHARGE OF CHIMNEY WEIR UNDER FREE AND SUBMERGED FLOW CONDITIONS

FLUID MECHANICS Time: 1 hour (ECE-301) Max. Marks :30

Structure of Mechanically Agitated Gas-Liquid Contactors

Evaluating Surge Potential in CSO Tunnels

PRESSURE DISTRIBUTION OF SMALL WIND TURBINE BLADE WITH WINGLETS ON ROTATING CONDITION USING WIND TUNNEL

Numerical investigation of transition between free surface flow and pressurized flow for a circular pipe flowing full upstream

EXAMPLES (OPEN-CHANNEL FLOW) AUTUMN 2018

Irrigation &Hydraulics Department lb / ft to kg/lit.

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

ANSWERS TO QUESTIONS IN THE NOTES AUTUMN 2018

Designing Wave Energy Converting Device. Jaimie Minseo Lee. The Academy of Science and Technology The Woodlands College Park High School, Texas

Discharge Coefficient in Oblique Side Weirs

PHYS 101 Previous Exam Problems

Experimental Investigation of Clear-Water Local Scour at Pile Groups

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

MEMORANDUM. Investigation of Variability of Bourdon Gauge Sets in the Chemical Engineering Transport Laboratory

UTILIZATION OF LEAKY PIPES AS AERATION SYSTEM FOR AQUACULTURE

Lecture 10 : Sewer Appurtenances

Design, Static Structural & Model Analysis of Water Ring Vacuum Pump Impeller

INCREASE METHODS OF DRAINAGE DISCHARGE OF INUNDATED WATER IN LOW FLAT LAND CONSIDERING BED DEFORMATION CHARACTERISTICS

Flow Characteristics and Energy Dissipation Over Traditional and Stepped Spillway with Semicircular Crest

19.1 Problem: Maximum Discharge

Figure 1 Figure 1 shows the involved forces that must be taken into consideration for rudder design. Among the most widely known profiles, the most su

The activated sludge process

The Discussion of this exercise covers the following points:

EFFECTS OF SIDEWALL OPENINGS ON THE WIND LOADS ON PIPE-FRAMED GREENHOUSES

FREE OVERFALL IN A HORIZONTAL SMOOTH RECTANGULAR CHANNEL

FL M FLUME FOR HYDRAULIC BENCH

SUBMERGED VENTURI FLUME. Tom Gill 1 Robert Einhellig 2 ABSTRACT

DAV - P. Product Catalogue DAV - P. Air release & Vacuum Break Valves. (Plastic Air Valves) DAV - P. Edition 2012

The Mechanism Study of Vortex Tools Drainage Gas Recovery of Gas Well

EXPERIMENTAL ANALYSIS OF FLOW OVER SYMMETRICAL AEROFOIL Mayank Pawar 1, Zankhan Sonara 2 1,2

Experimental Study of an Air Lift Pump

COMPUTATIONAL FLOW MODEL OF WESTFALL'S LEADING TAB FLOW CONDITIONER AGM-09-R-08 Rev. B. By Kimbal A. Hall, PE

APPLICATION NOTE. AN-9608 July 2001 SEEPAGE MEASUREMENT IN AN OPEN CHANNEL THROUGH A WEIR

CVEN 311 Fluid Dynamics Fall Semester 2011 Dr. Kelly Brumbelow, Texas A&M University. Final Exam

STUDIES ON THE OPTIMUM PERFORMANCE OF TAPERED VORTEX FLAPS

FLUID FORCE ACTING ON A CYLINDRICAL PIER STANDING IN A SCOUR

FORMAT FOR SENDING COMMENTS. Title: CRITERIA FOR DESIGN OF CANAL HEAD REGULATORS (Second revision of IS 6531)

3 1 PRESSURE. This is illustrated in Fig. 3 3.

Experimental Investigation on Changes of Water Surface Profile with Gaussian Shaped Bottom and Side Roughness

Plane Turbulent Wall Jets in Limited Tailwater Depth

Wind Directional Effect on a Single Storey House Using Educational Wind Tunnel

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

CTB3365x Introduction to Water Treatment

Chapter 3 EXPERIMENTAL: EQUIPMENT, SET-UP, AND PROCEDURE

Flow and Mixing in the Liquid between Bubbles

HYDRAULIC JUMP AND WEIR FLOW

Computational Analysis of Cavity Effect over Aircraft Wing

LIFE TIME OF FREAK WAVES: EXPERIMENTAL INVESTIGATIONS

Australian Journal of Basic and Applied Sciences. Pressure Distribution of Fluid Flow through Triangular and Square Cylinders

Study Of Windcatchers: The Mass Flow Rate And Inlet Air To The Building In Traditional Windcatchers

International Journal of Scientific & Engineering Research, Volume 5, Issue 1, January ISSN

Aerodynamic Analyses of Horizontal Axis Wind Turbine By Different Blade Airfoil Using Computer Program

EXPERIMENTAL STUDY OF ENERGY DISSIPATION OVER STEPPED GABION SPILLWAYS WITH LOW HEIGHTS *

Numerical Simulation And Aerodynamic Performance Comparison Between Seagull Aerofoil and NACA 4412 Aerofoil under Low-Reynolds 1

Plane Turbulent Wall Jets in Limited Tailwater Depth

Effects of seam and surface texture on tennis balls aerodynamics

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

Effects of Submergence in Montana Flumes

FABRICATION OF VERTICAL AXIS WIND TURBINE WITH WIND REDUCER AND EXPERIMENTAL INVESTIGATIONS

Aerodynamic Analysis of a Symmetric Aerofoil

Pressure distribution of rotating small wind turbine blades with winglet using wind tunnel

Development of High-speed Gas Dissolution Device

InvestigatingThe Effect of Number of Steps on Energy Dissipation of Stepped Spillways Based on the New Design Approach.

Course Teacher: Prof. Dr. M. R. Kabir SPILLWAY & IRRIGATION PUMPS. Spillway:

Numerical Fluid Analysis of a Variable Geometry Compressor for Use in a Turbocharger

Vertical Uplift Capacity of a Group of Equally Spaced Helical Screw Anchors in Sand

then the work done is, if the force and the displacement are in opposite directions, then the work done is.

SPECTRAL CHARACTERISTICS OF FLUCTUATING WIND LOADS ON A SEPARATE TWIN-BOX DECK WITH CENTRAL SLOT

INVESTIGATION OF PRESSURE CONTOURS AND VELOCITY VECTORS OF NACA 0015IN COMPARISON WITH OPTIMIZED NACA 0015 USING GURNEY FLAP

COURSE NUMBER: ME 321 Fluid Mechanics I Fluid statics. Course teacher Dr. M. Mahbubur Razzaque Professor Department of Mechanical Engineering BUET

Stability of Concrete Macro-Roughness Linings for Overflow Protection of Earth Embankment Dams ( 1 ) - Discussion

EFFECTS OF CHEMICAL ADDITIVES ON THE PRESSURE DROP IN THE PIPES

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Computational fluid dynamics analysis of a mixed flow pump impeller

EDUCTOR. principle of operation

EFFECTS OF WATER SPRAYS AND SCRUBBER EXHAUST ON FACE METHANE CONCENTRATIONS

Optimization of Blades of Horizontal Wind Turbines by Choosing an Appropriate Airfoil and Computer Simulation

Transcription:

World Applied Sciences Journal 9 (7): 712-717, 2010 ISSN 1818-4952 IDOSI Publications, 2010 Hydraulic Evaluation of the Flow over Polyhedral Morning Glory Spillways 1 2 2 A. Bagheri, M. Shafai Bajestan, H. Moosavi Jahromi, 3 4 H. Kashkooli and H. Sedghee 1 Ph.D Student of Irrigation Structures, Science and Research Branch, Islamic Azad University (IAU), Khouzestan, Iran 2 Department of Water Engineering, Shahid Chamran University, Ahvaz, Iran 3 Department of Irrigation, Islamic Azad University, Ahvaz Branch, Iran 4 Department of Irrigation, Science and Research Branch, Islamic Azad University (IAU), Tehran, Iran Abstract: Morning glory spillways are the type of spillways used where there is not adequate space to build other types of spillways to discharge flood water from reservoirs downslope dams, because morning glory spillways are placed upslope dams and inside dam reservoirs. In our study, we investigated the effect of polyhedral spillway crests on the discharge intensity of the flow passing through the spillways and on the discharge coefficient of morning glory spillways, by constructing physical hydraulic models of morning glory spillways and through carrying out 180 different experiments on these spillways. Analysis of experimental data showed that using polyhedral spillway crests caused an increase in discharge passing through the morning glory spillway and also increased the discharge coefficient of the spillway. The greatest increase was obtained when trihedral spillway crests were used. Key word:morning glory spillway Discharge coefficient of the spillway crest Length of the spillway crest Shape of the spillway crest INTRODUCTION by the orifice flow. From this stage onward, the pressurized orifice flow may become dominant and the When there is not adequate space to construct flow discharge be controlled by the filled tunnel. Of spillways to discharge floodwater from reservoirs dams, course, we must keep in mind that it is not recommended especially when dam sites are narrow and abutments are to design spillways on the basis of filled tunnels, but very steep, use of morning glory spillway is a suitable cases where the drop in height is very small may be option because these spillways are placed upslope dams exempted from this rule [3]. and inside dam reservoirs. They can also be employed where tunnels or diversion galleries having sufficient The discharge in morning glory spillways is expressed as diameters are available. Morning glory spillways are follow: mostly preferred in earth dams where we prefer to have the spillway separate from the dam structure and inside 1.5 Q = CdLH (1) the dam reservoir, because this will reduce the risk of scouring and shell saturation downslope the dam [1]. L = 2 R s (2) The cost of construction and maintenance of spillways accounts for the main part of the total cost of a dam Where Q is the discharge passing through the building project [2]. When the height of water over the morning glory spillway, C d is the discharge spillways crest is low in morning glory spillways, the flow coefficient of the morning glory spillway, L is the will be free and control will be at the spillway crest. length of the spillway crest, H is the height of water As water height increases, the control section is moved to over the spillway and R s is the radius of the spillway the vertical transition and the discharge will be controlled crest [4]. Corresponding Author: Ali Bagheri, Ph.D Student of Irrigation Structures, Science and Research Branch, Islamic Azad University (IAU), Khouzestan, Iran, E-mail: ali523b@yahoo.com. 712

Fig. 1: Trihedral, pentahedral and heptahedral morning glory spillway with crest diameter of 17 centimeters Morning glory spillways are in charge of discharging concluded that the length, height and orientation of the excess water from the dam when flooding happens, they blades and their thickness influenced whirlpool control, keep the water from spilling over the dam crest and with the increase in the length of blades being more prevent dam degradation (especially in earth fill dams) [5]. effective than the increase in the number of blades. If, at a constant height of water over the morning glory Zomorredian, et al. [10] constructed physical models of spillway, we can increase the discharge flowing over the vertical intakes, conducted experiments and concluded spillway by changing the shape of the spillway crest that the discharge number of the intake decreased with an (which, in plan has the circular form), this will cause an increase in the circulation number and also that aerating increase in the confidence factor of the morning glory the inlet of the intake had a negative effect on the spillway in discharging floodwater and will also lead to discharge number of the intake. cost cutting. In our study (as can be seen in Figure 1) In our study, we constructed physical hydraulic trihedral, pentahedral, and heptahedral morning glory models of morning glory spillways to investigate the spillways were constructed and the discharge passing effect of using polyhedral spillway crests on the intensity over these spillways and the discharge coefficients were of the discharge passing through the spillway and on the compared with those of a morning glory which had a morning glory spillway discharge coefficient, by carrying circular crest. The results obtained will be shown in the out various experiments on this type of spillways. section where we present our conclusions. Fattor and Bacchiega [6] concluded that in morning MATERIALS AND METHODS glory spillway, when they are submerged, the discharge intensity will be 1.34 times that of free flow and if the The physical model constructed to be used in water conveying tunnel is not aerated, there will be experiments carried out in the laboratory is shown in turbulent flow at the spillway. Rankin [7] divided Figure 2. It consists of a main tank with a capacity of 2000 whirlpool, into two parts: the central part which is liters which supplied the water required in conducting relatively small, has a high viscosity and is like a rigid the experiments. The main flume, which housed the whirling object and other part which has a lower viscosity funnel-shaped part of the morning glory spillway, had a (turns with a lower viscosity around the pressurized length of 250 cm, a width of 90 cm and a height of 40 cm. whirlpool). In the central part, the fluid in the whirlpool The side walls of the flume were made of eightturns in such a way that its tangential speed changes millimeter-thick glass. The flume bottom was made of linearly with the radius. plexiglas. The side walls and the bottom of the flume are Nohani, et al. [8] in their research, constructed a anchored by angle irons to resist the pressures exerted on physical model of the morning glory spillway and them. Water was transferred from the main tank to the conducted laboratory experiments to investigate the effect flume by four pumps. These pumps could transport of the number and thickness of whirlpool-break blades on discharge of 100-500 liters per minute for the main pump, the discharge coefficient of the morning glory spillway. 240 liters per minute for two similar medium-sized pumps They concluded that the joint effects of an increase in the and 110 liters per minute for the small pump. Four pumps number and in the thickness of the blades will increase the were used so that for low discharges the pumps could be discharge capacity of the morning glory spillway. used separately and for high discharges a combination of Ellesty, et al. [9] built physical models of the morning the pumps could be employed. Forty centimeters from the glory spillway, conducted laboratory experiments and inlet of the flume, fairing mesh was placed to reduce the 713

Fig. 2: General view of the physical hydraulic model used in the laboratory speed of the flow. A digital depth gauge with the spillways, the crests were trihedral, pentahedral and precision of 0.01 millimeter was used to measure water heptahedral. Altogether, 12 models of the funnel-shaped height over the morning glory spillway crests. part of the spillway were constructed and therefore, there We used the volumetric method to measure the were four models of the funnel-shaped part for each crest outflow from the morning glory spillways: the outflow diameter. from the morning glory spillway tunnel entered a 400-liter In our study, we started the experiments using the tank to which a piezometric tube was attached so that the morning glory spillway with the crest diameter of 14 water level in the piezometer was equal to that of the water centimeters and the internal shaft diameter of 5.7 in the tank, sensors were installed at points on the centimeters. First, we set up the reference model piezometric tube which were a specific distance apart from (with circular crest) and turned the pump on for the water each other (six points), these sensors were connected to to enter the flume from the main tank. When the height of a digital plate which recorded the time it took for the water water over the spillway crest became constant, it was level to reach from one sensor to the other. Given that the measured with a digital depth gauge and, at the same time, volume of water between the two sensors was known, the the outflow discharge from the spillway tunnel was discharge passing through was obtained by dividing this measured in the volumetric method. In this way, one point volume by the time recorded. To increase the accuracy, in the discharge rating curve of the spillway would be the measurements were carried out in five different time obtained. Then, by turning on one pump and intervals. To discharge the water from this tank to the combinations of pumps, we could establish a total of 15 main tank, we used a pump with a discharge of 600 liters different water heights over the spillway crest, use the per minute and a single-phase submergible pump with a volumetric method to measure the discharge passing discharge of eleven liters per minute. through the spillway which corresponded to each of these water heights and obtain the discharge rating curve of the METHODS USED IN THE EXPERIMENTS spillway. Then the funnel-shaped part of the spillway was removed and replaced with one having a trihedral crest, We constructed three morning glory spillways with the same as water heights of the previous experiment were crest diameters of 14, 17 and 20 centimeters (in which the established over this spillway, the discharge passing internal diameters of the shaft, the bend and the tunnel through the spillway corresponding to each water height were 5.7, 6 and 7.4 centimeters, respectively) in order to was measured and the discharge rating curve of this investigate the effect of using polyhedral spillway crests spillway was drawn. Then, the funnel-shaped part was on the discharge passing through the spillway and on the removed and replaced with one having a pentahedral discharge coefficient of the spillway. In all of these three crest, the above experiments were conducted and the spillways, the length of the water-conveying tunnel was discharge rating curve of the spillway was drown. Then one meter, the bend was 90 degrees and the shaft was the funnel-shaped part was removed and replaced with vertical. These three spillways, which had circular crests, one having a heptahedral crest, the above experiments were considered as reference spillway. From the funnel- were carried out and the discharge rating curve of the shaped part of each of these three spillways, three other spillway was drawn. Then the spillway was removed and spillways having the same dimensions were constructed, a morning glory spillway with a crest diameter of 17 the only difference between these three and the reference centimeters and an internal shaft diameter of 6 centimeters spillways being the shape of the crest in these three was put in, the above experiments were conducted and 714

Table 1: Specifications of spillways used in the experiments and the number of experiments carried out using the physical model in each one of them Name of the Diameter of spillway c Number of faces Number of Length of spillway crest experiment rest in centimeters in the polyhedral experiments in centimeters A1 14-15 43.96 A2 14 3 15 43.00 A3 14 5 15 43.60 A4 14 7 15 44.00 B1 17-15 53.38 B2 17 3 15 51.645 B3 17 5 15 52.55 B4 17 7 15 53.886 C1 20-15 62.80 C2 20 3 15 61.01 C3 20 5 15 61.70 C4 20 7 15 62.95 four discharge rating curves were obtained. Then the over each spillway were used to show the effect of spillway was removed and a morning glory spillway with employing polyhedral spillway crests on discharge a crest diameter of 20 centimeters and an internal shaft coefficients of spillways. Results obtained are shown in diameter of 7.4 centimeters was put in, the above Tables 2, 3 and 4. The heights of water mentioned in experiments were carried out and four discharge rating Tables 2, 3 and 4 for each spillway are for all of the three curves were obtained. Altogether, 180 experiments were states of free flow (crest control), half fill flow (orifice conducted. Specifications of spillways used in the control) and completely submerged flow (tunnel control). experiments and the number of experiments carried out Formula 1 was used to calculate the discharge coefficients using the physical hydraulic model can be seen in of morning glory spillways. Table 1. As can be seen from Tables 2, 3 and 4, using polyhedral spillway crests increases discharge RESULTS AND DISCUSSION coefficients of the spillway and the largest increase happened when trihedral spillway crests were used. It can We used data obtained from conducting 180 also be concluded that the effect of using polyhedral experiments in the laboratory to calculate the spillway morning glory spillway crests on increasing discharge coefficient in every experiment. Several heights of water coefficients was more pronounced in free flow Table 2: Discharge coefficients of morning glory spillways with crest diameter of 14 centimeters Percentage increase Percentage increase in Cda3 Percentage increase in Cda4 H(cm) Cda1 Cda2 in Cda2 as compared to Cda1 Cda3 as compared to Cda1 Cda4 as compared to Cda1 2 0.937 1.471 57.56 1.297 38.38 1.124 19.98 4 0.431 0.677 56.85 0.602 39.41 0.562 30.26 6 0.255 0.419 61.36 0.377 48.02 0.340 33.35 8 0.185 0.306 64.8 0.283 52.74 0.243 30.78 14 0.158 0.208 31.77 0.188 18.88 0.173 9.6 Table 3: Discharge coefficients of morning glory spillways with crest diameter of 17 centimeters Percentage increase Percentage increase in Cdb3 Percentage increase in Cdb4 H(cm) Cdb1 Cdb2 in Cdb2 as compared to Cdb1 Cdb3 as compared to Cdb1 Cdb4 as compared to Cdb1 2.1 0.867 1.336 53.96 1.113 28.24 0.939 8.21 4 0.702 0.992 41.26 0.875 24.59 0.747 6.33 6 0.420 0.566 34.68 0.515 22.51 0.452 7.46 8.5 0.317 0.386 21.86 0.360 13.7 0.329 3.81 10 0.293 0.3429 16.95 0.321 9.78 0.302 3.06 Table 4: Discharge coefficients of morning glory spillways with crest diameter of 20 centimeters Percentage increase Percentage increase in Cdc3 Percentage increase in Cdc4 H(cm) Cdc1 Cdc2 in Cdc2 as compared to Cdc1 Cdc3 as compared to Cdc1 Cdc4 as compared to Cdc1 3 1.164 1.577 35.45 1.366 17.31 1.284 10.26 4 0.995 1.245 25.19 1.134 13.99 1.052 5.74 6 0.555 0.689 24.01 0.648 16.66 0.592 6.56 8 0.372 0.460 23.35 0.428 14.85 0.390 4.66 14 0.224 0.267 18.94 0.250 11.42 0.232 3.55 715

Fig. 3: Changes in spillway discharge coefficient in relation to depth of submergence in spillways crest diameter of 14 centimeters Fig. 4: Changes in spillway discharge coefficient in relation to depth of submergence in spillways crest diameter of 17 centimeters Fig. 5: Changes in spillway discharge coefficient in relation to depth of submergence in spillways crest diameter of 20 centimeters 716

(crest control) and half fill flow (orifice control) than crests is more effective in increasing discharge in completely submerged flow (tunnel control). In the coefficients in free flow (crest control) and half fill flow following figures, changes in discharge coefficients of (orifice control) than in completely submerged flow spillway in relation to depth of submergence are (tunnel control), (2) discharge coefficients of heptahedral shown for spillways with crest diameters of 14, 17 and spillway crests are close to those of circular reference 20 centimeters. spillway crests, (3) polyhedral spillway crests are more The following conclusions can be drawn from effective in increasing discharge coefficients when the Figures 3, 4 and 5: (1) at the same depth of submergence, height of water over the spillway crest is low than when discharge coefficients of spillways with polyhedral crests it is high and (4) discharge coefficients decrease as the are higher than those for spillways with circular crests, (2) depth of submergence increases. the largest increase in discharge coefficient happens when trihedral spillway crests are used, (3) discharge REFERENCES coefficients found when heptahedral spillway crests were used were close to those of the reference spillways 1. Afshar, A. and G.H.R. Neeksefat, 1994. Design of which had circular crests, (4) polyhedral spillway crests Hydraulic Structure for Small Dams, Science and are more effective in increasing discharge coefficient Industry University Press, Iran, Tehran. when the height of water over the spillway is lower than 2. Kevin, M., P.E. Boyd and A. Michael, 1997. morning when it is high, because the distances between the Glory Spillway Repairs at Kingsley Dam. Proceeding beginning parts of the curves and the reference curve are of the International Conference on Hydropower bigger than the distances between the end parts of the Held in Atlanta. Georgia, pp: 5-8. curves and the reference curves and (5) discharge 3. Novak, P., 1971. Hydraulic Structure Design. coefficients decrease with an increase in the depth of University Of Newcastle, English. submergence. 4. U.S. Bureau Of Reclamation, 1965. Design Of Small Dams,Water Resources Technical Publications. CONCLUSION 5. Samani, H., 1997. Design of Hydraulic Structures, Dezab Consultant Engineers Publications, Iran, Conclusions which can be drawn from this research Ahvaz. pp: 253 through investigating and analyzing the above tables and 6. Claudio, A. Fattor and Jorge D. Bacchiega, 2003. figures, are that using polyhedral spillway crests Analysis of Instabilities In The Change of Regime increases discharge coefficients and that the biggest In Morning Glory Spillways, J. Hydraulic Res., increase in discharge coefficients of morning glory pp: 40-4. spillways happens when spillway crests are trihedral. 7. Rankin, 1958. Efficiency Of Air-Entraining Vortex At Nohani, et al. [8] also concluded from their research, in Water Intakes, J. Hydraulic Engineering, ASCE. Div. which they had constructed physical hydraulic models of By: 7. morning glory spillways and had carried out laboratory 8. Nohani, E., 2009. Effect of the Number and experiments to investigate the effect of the number and Thickness of Whirlpool-break Blades on the the thickness of whirlpool-break blades on the discharge Discharge Coefficient of the Morning Glory Spillway. coefficients of morning glory spillways, that, in sharp Water and Soil and Plant National Conference, crested morning glory spillways, the use of three Islamic Azad University (IAU), Iran, Dezfol. In whirlpool-break blades was more effective in increasing Persian. pp: 6 discharge coefficients than using six whirlpool-break 9. Ellesty, K., 2006. Effect of Whirlpool-break Blades on blades. Ellesty, et al. [9] also built physical hydraulic the Discharge Coefficient of the Morning Glory models of morning glory spillways, did laboratory Spillway. Irrigation and Drainage Networks National experiments and concluded that the length, the height and Conference, Shahid Chamran University, Iran, the orientation of the blades and their thickness were Ahvaz. In Persian. pp: 8. effective in controlling whirlpool and that increasing the 10. Zomorredian, M.A., 2004. Effect of the Geometry of length of blades was more effective than increasing their Headrace Channel on Vortex and Discharge number. The following conclusions can be drawn from our coefficient. Iranian, J. Agricultural Sci., In Persian. study: (1) the use of polyhedral morning glory spillway 35(3): 10. 717