SWIMMING POOL CERTIFICATE GUIDE

Similar documents
Protocol for Private Galas

FINA FACILITIES RULES

FINA FACILITIES RULES

FINA FACILITIES RULES

Swim Ontario Comprehensive Facility Rules Compliance Document

ALGE SWIM2000. Architectural Guideline ALGE

DIVING FACILITIES CERTIFICATE FOR OLYMPIC GAMES AND WORLD CHAMPIONSHIPS JANUARY 2017

USA Swimming Measuring and Certifying Competition Pools

SAFETY MARSHAL, MARSHAL, & TIME KEEPER LEVEL I CLINIC

INTRODUCTION TO SWIMMING OFFICIATING. October 16, 2015

TEACHING RACING STARTS SAFETY PROTOCOLS AND CHECKLIST

FINA SWIMMING OFFICIALS CLINICS. Presentation Overview

JANUARY 2011 EQUIPMENT LIST CONTENTS: 1. SWIMMING LANES 2. STARTING BLOCKS 3. STORAGE DRUMS FOR SWIMMING LANES 4. WATERPOLO GOALS

WELCOME. The goal of any volunteer or official is to contribute to a fair, safe and positive environment. The goal of this session is to:

SWIMMING TECHNICAL PACKAGE Saskatchewan Summer Games July 26 - Aug 1, 2020 Lloydminster, Saskatchewan

Racing Start Safety Certification Protocol PROPOSAL. Combined Forward and Backstroke

COMPETITION EQUIPMENT. Enjoy the game

MAY 2015 EQUIPMENT LIST CONTENTS: 1. SWIMMING LANES 2. STARTING BLOCKS 3. STORAGE DRUMS FOR SWIMMING LANES 4. WATERPOLO GOALS AND FIELD LINES

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 8 RECREATION FACILITIES

TECHNICAL RULE CHANGES

Racing Start Safety Certification Protocol. Forward and Backstroke Starts. Updated: February 2018

APPENDIX IV DEVELOPMENT AND MEASUREMENT RULES OF THE INTERNATIONAL TEN SQUARE METRE SAILING CANOE (JANUARY 2008) 1 GENERAL

FINA OPEN WATER SWIMMING RULES

BRIEFING NOTES FOR TIMEKEEPER. Candidate Name.

APPENDIX D OPEN WATER SWIMMING RULES

Water Polo Goals. Anti Goal - FINA 1080mm CODE PRODUCT DESCRIPTION WEIGHT VOLUME. 750mm 1080mm

O K D I A MEASUREMENT FORM INTERNATIONAL OK DINGHY CLASS

Standards vs. Guidelines. Public Right-of Way Accessibility Guidelines (PROWAG)

PART V FINA DIVING RULES

FINA OPEN WATER SWIMMING RULES

Synchronised Swimming. Figure Grade 1

All movements of the arms shall be simultaneous and in the same horizontal plane without alternating movement.

Accurate Measurement,Quick Processing,and Real-Time Display- SEIKO supports swimmimg competitions in a comprehensive manner.

INTRODUCTION TO SWIMMING OFFICIATING. August 24, 2018

APPENDIX IV DEVELOPMENT AND MEASUREMENT RULES OF THE INTERNATIONAL TEN SQUARE METER SAILING CANOE

RULES PUBLICATION NO. 44//P PILOT TRANSFER ARRANGEMENTS July

METHODS EMPLOYED IN LOCATING SOUNDINGS

APPENDICES SWIMMING NSW LTD. Page 1 of 12

Chapter 5. General Site and Building Elements

California Building Code Effective January 2014 HOUSING ACCESSIBILITY BATHING FACILITIES Title 24, Part A

APPENDICES SWIMMING NSW LTD. Page 1 of 13

SWIMMING 2017 GENERAL RULES

All Swimming Australia Ltd (SAL) Open Water Swimming Championships and Open Water Swimming competitions shall be governed by SAL s Rules and By-Laws.

2014 JUNIOR LIFEGUARD TELEGAMES

The swimming pool brand

Surf Life Saving New Zealand. NZ Pool Championships Manual. 50m Pool

1 & 3 Meter Tower CAT 1M 203R RIGHT MOUNT CAT 3M 203R CAT 1M 203L LEFT MOUNT CAT 3M 203L CAT 1M 203D DUAL MOUNT CAT 3M 203D

Design, Operation and Maintenance of a Swimming Pool

RESOLUTION A.1045(27) RECOMMENDATION ON PILOT TRANSFER ARRANGEMENTS

ST. VINCENT AND THE GRENADINES

CRAA Open Summer Long Course Kick-off

GREAT LAKES REGION BOARDING ARRANGEMENTS FOR PILOTS

The Agility Association of Canada

Swimming practical examination support materials

FINA HIGH DIVING RULES

1/2 METER FLYTE-DECK II FIBERGLASS STAND (6' BOARD) (8' BOARD) (10' BOARD)

COMPETITION EQUIPMENT

U STYLE DIVING FRAMES

STROKES AS DESCRIBED BY SWIMMING CANADA

SWA OPEN WATER SWIMMING RULES

Sample Summer Swim League Swimming Rules and Regulations

EXTRACT FROM FINA RULES as detailed in the. Extracts of ASA Laws and ASA Technical Rules 2010

OPEN MEET LICENSING GUIDELINES

2016 LA84 Foundation Summer Swim Program Swim Coaches Packet

The Swim Official. Arizona Swimming

INDEX. Index INDEX. Cable swim xi Clerk of Course 24 Club xi membership 56 National Championship scoring 37 College Club 55 Colonies Zone 133 Color 47

SWIMMING SPORT RULES. Swimming Sport Rules. VERSION: June 2018 Special Olympics, Inc., 2018 All rights reserved

2010 JUNIOR LIFEGUARD TELEGAMES

FINA MASTERS RULES. General. Masters General rules. Masters Swimming rules. Masters Open Water Swimming rules. Masters Diving rules

GENERAL EVENT RULES (UPDATED 7 MARCH 2015)

Paper Tiger Catamaran International Association MEASUREMENT FORM

PUBLIC POOL CHECKLIST. (This checklist is based on the Ministry of Municipal Affairs and Housing checklist)

THE MANCHESTER OPEN MEET 2018

TRAINING PROGRAM UNIT 8 JUDGE OF STROKE

Bye-Laws to Rules 35 to 37 Courses

TIMEKEEPER WORKBOOK. Candidate Name... Club...

Synchronised Swimming. Skill Level 5

SWIMMING STROKE RULES. An Extraction of SwimmingSA Swimming Rules

THE MANCHESTER OPEN MEET 2018

THE MANCHESTER OPEN MEET 2017

Chapter Twelve: Clout Archery

1.5 m. 2.4 m. Fig the pressure exerted by the oil on the base of the tank, the force exerted by the oil on the base of the tank.

STARTER TRAINING NOTES. Adopted or Amended By Whom Date Board of Directors Adopted TSC May, 2013 Amended TSC August 2016 Amended TSC October 2016

Round pool 52 (1,32m)

SECTION 4 ILS COMPETITION MANUAL POOL EVENTS

SUMMER NON NATIONAL QUALIFIER LONG COURSE GRADED MEET 2018

JUDGE OF STROKES TRAINING NOTES

Present their... SUMMER NON NATIONAL QUALIFIER LONG COURSE GRADED MEET

Installation Guide Wall Mounted Angled Flagpole

Design Overview. Section 4 Standard Plans for Design. Pedestrian Access Routes. Pedestrian Access Routes. Overview. Cross Slope

PTV OBSTACLES The following PTV obstacles are approved for use in Affiliated BHS TREC events

Safety Code of Practice for Clubs and Regions (& National Competitions)

SWIMMING FLOATS & SWIM AIDS

APPENDIX C PARA-SWIMMING - IPC RULES

WELCOME. The goal of any volunteer or official is to contribute to a fair, safe and positive competitive environment The goal of this session is to:

Revisions to the Regulations for Agility Trials

FIELD EVENTS DIAGRAMS

Portland Peninsula Sidewalk and Ramp Inventory

1 A Mangonel is a type of catapult used to launch projectiles such as rocks. A student made a working model of a Mangonel. crossbar. bucket.

swimming and diving AND RULES AND INTERPRETATIONS

Transcription:

SWIMMING POOL CERTIFICATE GUIDE FEBRUARY

BUILDING DRAWING - KEY PLAN POOL DRAWINGS - / Longitudinal Section / Floor Plan / Cross Section /

MEASUREMENT CRITERIA.- The measurements shall be done by a ceritfied surveyor, appointed or approved by the Member in the country in which the pool is situated..- The surveying equipment shall be a Total Station. The minimum requirements of the Total Station are the following: - Angle Measurement Accuracy Hz and V: " (. mgon) - Distance Measurement Accuracy: mm +.ppm.- All the points to be measured shall be marked with Self-adhesive Reflective Targets..- The measurements corresponding to the FR.,.,.,.,.,. and. shall be measured with the pool full of water..- The measurements corresponding to the FR.,. should be measured with the pool empty..- The temperature of the water shall be between - ºC.- The length of the pool FR.,. shall be measured in the centre of each lane..- The width of the pool FR. shall be measured in both ends of the pool. 9.- The depth of the pool FR. shall be measured at least in point per lane: m and m from each end wall and in the centre of the pool..- The verticality of the end walls FR. shall be measured in the centre of each lane. The walls shall form 9 degrees right angles, not less than.m below and.m above the surface of the water. The tolerance is ±.º. ORTHOGONALITY OF THE POOL The sides of the pool shall be orthogonal and form 9 degrees right angle. The tolerance of the angle is ±.º. The diagonals shall be the same length. The tolerance of the diagonal is mm. ORTHOGONALITY OF THE POOL DEGREES / m Angle Angle Angle Angle Diagonal Diagonal

FR. - LENGTH / FR. - DIMENSIONAL TOLERANCES FR. -. /. metres. When touch panels of Automatic Officiating Equipment are used on the starting end, or additionally on the turning end, the pool must be of such length that ensures the required distance of. /. metres between the two panels. FR. - The admissible tolerance in. m /. m swimming pools will be +., -.. Tolerances will be measured as follows :. Wall to Wall : Minimum. /. - Maximum. /.. Touch pad to Touch pad : Minimum. /. - Maximum. /. Tolerances have to be consistent. mm above to. metre bellow the water surface.these measurements should be certified by a surveyor or other qualified official, appointed or approved by the Member in the country in which the pool is situated. LANE No Length measured in the centre of the lane. A (m). B (m) 9.. A. B

FR. - LENGTH / FR. - DIMENSIONAL TOLERANCES FR. -. /. metres. When touch panels of Automatic Officiating Equipment are used on the starting end, or additionally on the turning end, the pool must be of such length that ensures the required distance of. /. metres between the two panels. FR. - The admissible tolerance in. m /. m swimming pools will be +., -.. Tolerances will be measured as follows :. Wall to Wall : Minimum. /. - Maximum. /.. Touch pad to Touch pad : Minimum. /. - Maximum. /. Tolerances have to be consistent. mm above to. metre bellow the water surface.these measurements should be certified by a surveyor or other qualified official, appointed or approved by the Member in the country in which the pool is situated. LANE No Length measured in the centre of the lane. A (m). B (m) 9.. A. B

FR. - WIDTH FR. - Width: There is no restrictions in width. Lanes shall be at least. metres wide, with two spaces of at least. metre outside of the first and last lanes. FR. - WIDTH m End wall. Pool Width End wall. Pool Width FR. - DEPTH FR. - A minimum depth of. metres, extending from. metre to at least. metres from the end wall is required for pools with starting block. A minimum depth of. metre is required elsewhere. DEPTH m Minimum depth at points. A Minimum depth at points. B Minimum depth elsewhere... A. B β FR. - WALLS FR.. - End walls shall be vertical, parallel and form 9 degree right angles to the swimming course and to the surface of the water. They shall be constructed of solid material, with a non slip surface extending. metre below the water surface. LANE No Angle β - End wall Angle β - End wall 9 FR.. - Rest ledges along the pool walls are permitted; they must be not less than. metres below the water surface, and may be. metre to. metre wide. Both internal and external ledges are acceptable, however internal ledges are preferred. FR.. - REST LEDGES Rest ledges Rest ledges compliant with FR.. YES NO

FR - SWIMMING POOLS FR. - LANES / FR. LANE ROPES FINA RULE COMPLIANT NONCOMPLIANT FR. - Lanes shall be at least. metres wide, with two spaces of at least. metre outside of the first and last lanes. FR.. - In an lane pool, lane ropes shall extend the full length of the course, secured at each end wall to anchor brackets recessed into the end walls. The anchor shall be positioned so that the floats at each end wall of the pool shall be on the surface of the water. Each lane rope will consist of floats placed end-to-end having a minimum diameter of. metre to a maximum of. metre. In a swimming pool the colour of the lane ropes should be as follows: The floats extending for a distance of. metres from each end of the pool shall be of RED colour. There shall not be more than one lane rope between each lane. The lane ropes shall be firmly stretched. FR.. - At the -metre mark from each end wall of the pool the floats shall be distinct in colour from the surrounding floats. FR.. - In metre pools the floats shall be distinct to mark metres. Lane ropes measurements, please read in conjunction with below diagram. Min.m / Max.m.. False Start. False Start Backstroke Backstroke. 9 9.

FR. - STARTING PLATFORMS FR. - Starting Platforms shall be firm and give no springing effect. The height of the platform above the water surface shall be from. metre to. metre. The surface area shall be at least. metre x. metre and covered with a non-slip material. Maximum slope shall not be more than degrees. The platform shall be constructed so as to permit the gripping of the platform by the swimmer in the forward start at the front and the sides; it is recommended that, if the thickness of the starting platform exceeds. metre, grips of at least. metre width on each side and. metre width in the front be cut out to. metre from the surface of the platform. Handgrips for the forward start may be installed on the sides of the starting platforms. Handgrips for backstroke starts shall be placed within. mete to. metre above the water surface both horizontally and vertically. They shall be parallel to the surface of the end wall and must not protrude beyond the end wall. The water depth from a distance of metre to metres from the end wall must be. metres where starting platforms are installed. Electronic read-out boards may be installed under the blocks. Flashing is not allowed. Figures must not move during a backstroke start. FR. - STARTING PLATFORM COMPLIANT NONCOMPLIANT The height of the platform (. A) above the water surface shall be from. metre to. metre. The surface area of the platform shall be at least. metre x. metre (. B x. C ) and covered with a non-slip material. Maximum slope of the platform shall not be more than degrees (. β). The platform shall be constructed so as to permit the gripping of the platform by the swimmer in the forward start at the front and the sides Handgrips for backstroke starts shall be placed within. metre to. metre above the water surface both horizontally and vertically (. D,E). They shall be parallel to the surface of the end wall and must not protrude beyond the end wall.. β. A. D. E. B. C FR.9 NUMBERING FINA RULE COMPLIANT NONCOMPLIANT FR.9 - Numbering: Each starting block must be distinctly numbered on all four sides, clearly visible. It is recommended that lane number shall be on the right-hand side when facing the course from the starting end with exception of m events, which may start from the opposite end. Touch panels may be numbered on the top part.

FR. - BACKSTROKE TURN INDICATORS FINA RULE COMPLIANT NONCOMPLIANT FR. - Backstroke Turn Indicators: Flagged ropes shall be suspended across the pool,. metres above the water surface, from fixed standards placed. metres from each end wall. Distinctive marks must be placed on both sides of the pool, and where possible on each lane rope,. metres from each end wall. FR. - BACKSTROKE LEDGE FR. - A backstroke ledge may be used: - The ledge may be adjustable to cm above or cm below the water level. - The ledge is a minimum of cm in length. - The ledge must be cm in height, cm at the width with degrees of slope YES NO Backstroge Ledge Backstroge Ledge compliant with FR. FR. - FALSE START ROPE FINA RULE COMPLIANT NONCOMPLIANT FR. - False Start Rope may be suspended across the pool not less than. m above the water level from fixed standards placed. m in front of the starting end. It shall be attached to the standards by a quick release mechanism. The rope must effectively cover all lanes when activated. FR. - WATER TEMPERATURE FINA RULE COMPLIANT NONCOMPLIANT FR. - Water temperature shall be to. During competition the water in the pool must be at a constant level, with no appreciable movement. In order to keep the water level, preserve the transparency of water and take into consideration the health regulations in force in most countries, inflow and outflow has to be regulated as follows: - to m/h for. m pools - to m/h for. m pools - to m/h for. m pools At these turnover rates, the water distribution has to be such that no appreciable current or turbulence is created. FR. - LIGHTING FINA RULE FR. Lighting - Light intensity over starting platforms and turning ends shall not be less than lux. COMPLIANT NONCOMPLIANT

FR. - LANE MARKINGS FR. Lane Markings - shall be of a dark contrasting colour, placed on the floor of the pool in the centre of each lane. Width: minimum. metre, maximum. metre. Length:. metres for metre long pools /. metres for metre long pools. Each lane line shall end. metres from the end wall of the pool with a distinctive cross line. metre long and of the same width as the lane line. Target lines shall be placed on the end walls or on the touch panels, in the centre of each lane, of the same width as the lane lines. They shall extend without interruption from the deck edge (curb), to the floor of the pool to a maximum of metres. A cross line. metre long shall be placed. metre below the water surface, measured to the centre point of the cross line. For m pools constructed after January, cross lines. metre long shall be placed at the metre mark from each end of the pool. After October this shall be measured from the end wall to the centre point of the cross line. LANE No A B C D E F H 9 F D A A E H A B A A B C FR. - BULKHEADS FR. Bulkheads When a bulkhead serves as an end wall, it must extend the full width of the course and present a solid smooth, non-slippery stable vertical surface on which touch pads may be mounted extending not less than.m below and.m above the surface of the water, and must be free of hazardous openings above or below the waterline which may be penetrated by a swimmer s hands, feet, toes or fingers. A bulkhead must be of a design that provides for the free movement of officials along its length without such movement creating any appreciable current or water turbulence. YES NO Bulkheads Bulkheads compliant with FR.