Exposure System Selection

Similar documents
RADIOLOGY/ FLUOROSCOPY 15 RAD-CHECK PLUS X-RAY EXPOSURE METER

Chapter 9 Human Use of Radiation Producing Equipment

Victoreen and

Monitor Unit Calculations Part 1. Return to our first patient. Purpose. 62 yr old woman with Stage IIIB (T1N3M0) NSCLC rt lower lobe Dose prescription

Relative Dosimetry. Photons

Exradin Ion Chambers. What attributes make Exradin the smart choice? EXRADIN Ion Chambers

Radiation Producing Machines Radiation Safety Training for X-ray Diffraction Units

Field size and depth dependence of wedge factor for internal wedge of dual energy linear accelerator

Victoreen B. Operators Manual. Image Intensifier Ion Chamber

Commissioning and periodic tests of the Esteya electronic brachytherapy system

Improve Process Reliability

Introduction. Materials and Methods

Constancy checks of well-type ionization chambers with external-beam radiation units

Introduction. Introduction. The CyberKnife SRS/SBRT System. Introduction. Contour Structures. CyberKnife Components

Basics of Proton Therapy. Proton Treatment Planning and Beam Optimization

STS PECVD Instructions

Absorption measurements for a carbon fiber couch top and its modelling in a treatment planning system

Instrumentation & Data Acquisition Systems

CHAPTER 4 PRE TREATMENT PATIENT SPECIFIC QUALITY ASSURANCE OF RAPIDARC PLANS

The MC commissioning of CyberKnife with MLC (Tips and Tricks)

Oxygen Flue Gas Analyzer BA 2000

Review of fundamental photon dosimetry quantities

Clinical Implementation of the TG-51 Protocol. David Followill Radiological Physics Center Houston Texas

Local Rules for Radiography: Ionising Radiation Regulations Working Instructions Staff MUST Follow

Chapter I Standard application in photon dosimetry José Guilherme Pereira Peixoto Maria da Penha Potiens

Outline. Chapter 11 Treatment Planning Single Beams. Patient dose calculation. Patient dose calculation. Effect of the curved contour surface

CONTROL and INSTRUMENTATION

Proton Therapy QA Tools

Zoubir Ouhib Lynn Cancer Institute

TG-61 deals with: This part of the refresher course: Phantoms. Chambers. Practical Implementation of TG-61:

Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves

Only 8% to go. TOTAL 1494 of 1623 ACTIVE INSTITUTIONS (92%) May-09. May-04 Nov-04. May-07. Nov-02 May-03. Nov-05. Nov-06. Nov-07 May-08.

Larry A. DeWerd, Ph.D., FAAPM UW ADCL & Dept. of Medical Physics University of Wisconsin

13 QUALITY ASSURANCE OF A LINEAR ACCELERATOR 13.1 COLLIMATOR ISOCENTER, JAWS, LIGHT FIELD VS INDICATORS, COLLIMATOR ANGLE INDICATORS.

Tower Rescue Lesson Three Tower Rescue: Operations

JME Portable 6 MeV X-RAY BETATRON Microprocessor model: PXB-6 M For Radiographic Non Destructive Testing

CALCULATING SOLUTIONS AND DRUG DOSE RATES. % solution = (weight (g) 100) volume of solution (ml)

The Royal Australian and New Zealand College of Radiologists. FRANZCR Examination Part I Radiation Oncology. Radiotherapeutic Physics.

Cardiac Output Simulation for Specific Makes of Monitor. Each injection yields in a time-temperature curve whose area represents the cardiac output:

Dissolved Oxygen Guide

IMRT in clinical practice at the UMC-Utrecht. Utrecht

X-FACTOR THINKING CHANGING THE WAY YOU THINK ABOUT DR A SINGLE DETECTOR. A FAMILY OF SOLUTIONS. DRX Family of Products

Radiation Protection in Radiology Large Facilities

OBJECTIVE 6: FIELD RADIOLOGICAL MONITORING - AMBIENT RADIATION MONITORING

Medical Instruments in the Developing World

Nuclear Associates

IDeA Competition Report. Electronic Swimming Coach (ESC) for. Athletes who are Visually Impaired

Variable Depth Bragg Peak Test Method

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Monitor Unit Calculations Part 2. Calculation of machine setting. Collimator setting

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

Quality Management Determined from Risk Assessment

Dosimetric Calculations. Lonny Trestrail

Failure Mode and Effect Analysis (FMEA) for a DMLC Tracking System

Instrumentation & Data Acquisition Systems

LECTURE 9 1. CARE AND PRECAUTION OF X-RAY TUBE 2. X-RAY TUBE AGING KAAB

OPERATION. Estimated kerf width compensation. HPR260 Manual Gas Instruction Manual 4-9

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

1. Question Answer cgy / MU cgy / MU 2. Question Answer

Monitor Unit Verification for Small Fields

Confidence comes with knowing you are Code-Ready.

APPLICATION NOTES DELOMATIC 4, DM-4 GAS

Application Note AN-107

Respiration. Figure 22: Schematic representation of the respiratory system

SnapShot IMRT with compensators and FFF beams

Math Review. Overview

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

ANZAI AZ-733VI. Respiratory Gating System. since 1976

FUGASHIN SAIGON FOOT MEASUREMENT GUIDE

Mild steel. Stainless steel. HPR130XD Auto Gas Revision 2. Nozzle retaining cap. tube. Shield cap 30 A 50 A 80 A 130 A

Radiotherapy physics & Equipments

Experiment 1 Introduction to Some Laboratory Measurements

Mechanical Ventilation. Which of the following is true regarding ventilation? Basics of Ventilation

Gait Analysis at Your Fingertips:

23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN APRIL 2007

Operating Procedures for Metal Evaporator I

Justification and use of hand-held X-ray equipment

Benefits of Detailed Compressor Modeling in Optimizing Production from Gas-Lifted Fields. Manickam S. Nadar Greg Stephenson

User Manual PTW-DensiX. D / Di/Zi

Accurate Measurement,Quick Processing,and Real-Time Display- SEIKO supports swimmimg competitions in a comprehensive manner.

Barrier Development and Evaluation Methodology. D.S. Musgrave 1 1 Thermal Visions, Inc., Granville, USA

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

CLINICAL IMPLEMENTATION OF RAPIDARC Treatment Planning Strategies to Improve Dose Distributions

The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

APA software instruction manual

Additional Science Unit Physics P2. Physics Unit Physics P2 PHY2H. (Jan11PHY2H01) General Certificate of Secondary Education Higher Tier January 2011

Leadership in Fluid Management

THE development of more advanced techniques in radiotherapy,

PRad Target. Chris Keith JLab Target Group

TG-119 IMRT Commissioning Tests Instructions for Planning, Measurement, and Analysis Version 10/21/2009

Hydronic Systems Balance

Degassing ERC KK Saitama, Japan

Which compressed air system design is right for you?

Advanced Pump Control for Irrigation Applications

Micro Motion 3098 Gas Specific Gravity Meter

Badan Jadrowych Nuclear Research Institute. Report INR No. 739/XIX/D CERN LIBRARIES, GENEVA CM-P Differential Recombination Chamber

Items 1, 2, 3, and 4: Origination, CHC-A details, Tracking status, Administrative details

UsER manual for Watersens ph -REDOX

MMS Mercury Monitoring System for Natural Gas

Drilling Efficiency Utilizing Coriolis Flow Technology

Transcription:

Principles of Imaging Science II (RAD120) Exposure Systems Exposure System Selection Radiographic exposure is a very complex process Best technique systems manipulate one variable while holding others constant Goal of any exposure system is consistency Facilities that post and maintain exposure technique charts have lower repeat rates Comparing Exposure Systems Technologists may develop personal preference Should use system employed by imaging facility Students should learn all possible systems before making personal selection 1

Anatomically Programmed Radiography (APR) Radiographer can override technique to customize for individual patients If well maintained, only a mas correction factor is necessary Computerized technique charts Radiographer selects body part/projection Phototiming Systems Automatic Exposure Control (AEC) Radiographer selects kvp and possibly backup ma and time Equipment automatically terminates exposure Art of phototiming requires learning when to use it and when not to use it Automatic Exposure Control (AEC, AED) Allows for consistent radiographic images regardless of patient size or pathology Results in lower patient dose, increased dept efficiency, lower film and processing cost, longer tube life 2

AEC TYPES - Ion Chamber Located below grid and above the cassette 2 electrodes separated by air encased in thin aluminum shell X-ray photons penetrate ion chamber e- in air are released, ionization occurs. Free e- attracted to positive electrode, flow along electric circuit to a capacitor Stores charge until maximum reached. Additional electricity causes discharge, activates timer for exposure termination. AEC TYPES Ion Chamber Control Panel Activation: AEC, 3 Chambers Selection is based on anatomical part Averaging of chambers AEC kvp, ma, Density Setting Effect on exposure time Backup Timer RT error in setup Correct bucky, tube, or grid centering 600 mas maximum 3

AEC: Minimizing Errors Positioning Pathology Prosthetic devices Collimation RSS Calibration AEC TYPES Phototimer Older type of AEC device Consists of: Fluoroescent screen Photomultiplier tube Located below cassette X-ray photons from patient interact with fluorescent screen. PM tube receives light energy from the screen, converts it to electrical energy. Energy passes to capacitor to terminate exposure. Cassettes cannot have lead foil Part Measurement No exposure system can work effectively without accurate measurement of part thickness Failure to measure part correctly will result in increased exposures and patient dose 4

Part Measurement Calipers Central ray entrance Thickest part Other Approach must be followed by all department radiographers Designed to produce consistent results Steps in development Produce phantom images Select optimal image Determine chart to utilize Phantom testing Clinical trials Fine tune chart and review periodically Fixed Kilovoltage Most often used Highest optimal kvp is used that is acceptable for the contrast desired mas is doubled for every 5cm of tissue 5 cm ankle = 6 mas 10 cm =? 5

Fixed kvp System ADVANTAGES Patient dose is minimized Contrast is uniform Increased exposure latitude Increased X-ray tube life Minimizes motion DISADVANTAGES Long scale contrast Limited variety of mas for pt. sizes Variable Kilovoltage mas is determined by body part thickness 2 kvp/cm + 30, or +40, or +50 Baseline 2 kvp/cm thickness 5 cm ankle = 10 kvp + 30, 40, or 50 If standard is determined to be 60 kvp, then 10 cm ankie = 70 kvp Variable kvp System ADVANTAGES Small kvp changes for body part thickness DISADVANTAGES Variable pt.dose Variable contrast Penetration not assured and/or overpenetration occurs 6

Film/Screen, CR, DR Application 7