SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

Similar documents
SKPx5.xxxUx Gas Valve Actuator with Safety Shutoff Function. SKP15.xxxUx SKP25.xxxUx SKP55.xxxUx SKP75.xxxUx

SKPx5.xxxUx Gas Valve Actuator with Safety Shutoff Function. SKP15.xxxUx SKP25.xxxUx SKP55.xxxUx SKP75.xxxUx

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Valve Proving System VDK 200 A S06*

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Valve Proving System VDK 200 A S02

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

SPECIFICATIONS ATTENTION

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

SPECIFICATIONS CAPACITY

SPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

RC 195 Receiver-Controller

Ratio Regulator Zero Governor. FRG/6 Series

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Gas Pressure Switch for DMV safety shutoff valves

GM-7000 Series CE Approved Gas Control Valve

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Powers Controls RC 195 Single Input Receiver-Controller

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

Pressure Switch for gas and air GGAO-A4

Dual Solenoid Gas Valve Installation

Pressure switch for gas and air

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Pressure Switch for gas and air

Pressure Switch for gas and air

C645A-E Pressure Switches

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Pressure Independent Control Series

North American Orifice Metering System

Bermad Pressure Reducing. Model: 42T

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

BGC258 Series BASOTROL Gas Valve

G96 Series BASOTROL Dual Operator Valve

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

Commonwealth of Massachusetts Approved Product Approval code G

Tightness controls TC 1 3 and TC 4

MEGR-1912 Instruction Manual

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

SPECIFICATIONS FRS. 2 1/2 DN (ISO) Flanged. FRS DN (ISO) Flanged

36H SERIES Combination Gas Valve

Powers Controls RC 195 Multiple Input Receiver- Controller

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

VMR VMR-OTN VMR 6 bar

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

VR46.5V(A)/VR86.5V(A) SERIES

DS06D,G Dial Set Pressure Regulating Valve

Actuators for gas valves

Tightness control TC. Product brochure GB 3 Edition AGA

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

CSA: Certified File No Never perform work if gas pressure or power is applied, or in the presence of an open flame. Safety first O.K.

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Butterfly Control Valve. DMK/6 Series

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

VGG... VGF... VGH... Gas Valves. Siemens Building Technologies HVAC Products VGG... VGF... VGH...

CSA: Certified File No Never perform work if gas pressure or power is applied, or in the presence of an open flame. Safety first O.K.

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

The installation and maintenance of this product must be done under the supervision of an experienced. Safety first IFGC CSA UL ANSI NFPA

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

TA-FUSION-P. NPT threads / ANSI flanges

Model: 43T. Bermad Pressure Relief Valve

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

SPECIFICATIONS ATTENTION

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

Powers Controls D Day-Night Thermostats

Transcription:

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25 pressure regulating electro-hydraulic actuators are used in combination with VG series gas valve bodies to provide safety shut-off and gas pressure regulation for industrial and commercial burners. The SKP25 can also be applied as a 1:1 air/gas ratio regulator or zero governor. Since a single valve performs two or more functions, fewer gas train components and fittings are required. This significantly reduces both the size and weight of the gas train. In addition, smaller diameter gas valves can be used. The compact SKP25 actuator opens slowly and closes immediately when power is interrupted. The modular design allows the SKP25 to be used in combination with all VG series gas valve bodies from 1/2-inch to 6-inch in size. The actuator is easily mounted on the square flange of any VG valve with four pre-mounted screws. A visible position indicator on the front of the actuator displays the entire stroke of the valve. A light indicates when the actuator is powered. Features UL listed, FM approved, CSA certified for USA and Canada, IRI approvable, ISO 9001 certified. European, Australian and Japanese approved versions available. Certified as a ventless pressure regulator. Safety shut-off function and pressure regulating function in one compact unit. Proof of Closure with Over Travel (POC) versions are available. Optional NEMA 4 protection. Visual position indication. "Power on" indication light Quick connect wiring terminals Optional adjustable auxiliary switch available. Applicable as 1:1 air/gas ratio regulator or zero governor. Accurate pressure control characteristics, and zero offset (droop). Modular design with 360 o actuator rotation for easy field wiring and installation. Low, 13.5 VA power consumption.

Technical Instructions SKP25 U.. Pressure Regulating Gas Valve Actuators Application SKP25 series actuators are combined with 1/2-inch to 6-inch VG series gas valve bodies. VG series gas valves must be ordered separately (See VG U...Technical Instructions, P/N 155-512P25). Product Numbers Table 1. Product Number 1 Operating Voltage Function Proof of Closure Switch 5 Auxiliary Switch 5 Type of Switch SKP25.011U1 regulator x SPDT SKP25.012U1 regulator x x SPDT SPDT SKP25.013U1 110 to 120 Vac regulator SKP25.411U1 2 regulator x SPDT SKP25.611U1 3 ratio regulator x SPDT SKP25.011U1P 4 ratio regulator x _ SPDT SKP25.012U2 regulator x x SPDT SPDT 220 to 240 Vac SKP25.013U2 regulator NOTES: 1. European, CE certified models are available (see data sheet 7643) 2. High outlet pressure model for 1.5 to 20 psi outlet pressure regulation 3. High bias air/gas ratio regulator with factory installed spring for 0" to 4" WC bias. 4. Low bias air/gas ratio regulator with factory installed spring for 0" to 0.6" WC bias. 5. Proof of closure and auxiliary switches cannot be field installed. Accessories Table 2. Product Number Description AGA22 Yellow setpoint spring for 6 to 48 WC (1.5 to 10 psi for SKP25.411U1) AGA23 Red setpoint spring for 40 to 100 WC (8.5 to 20 psi for SKP25.411U1) AGA25 Damping orifice for mounting into vent connection of SKP25.0 models AGA28 Black bias spring to install if SKP25.0 is used as air/gas ratio regulator or zero governor AGA29 Unpainted setpoint spring for 0 to 8.5 WC (included in SKP25.0 as standard) AGA66 Sealing gasket to provide NEMA 3, 3R, and 4 protection (for VGG /VGD valves) Specifications Agency approvals As a safety shut-off valve UL/429, FM/7400, ANSI Z21.21/CGA 6.5 C/I Agency marks apply only for SKPxx.xxxU actuators assembled with VGxxx.xxxU series gas valve bodies. As a pressure regulator ANSI Z21.18/CGA 6.3 Power supply Operating voltage 110 to 120 Vac + 10% to -15% 220 to 240 Vac + 10% to -15% Operating frequency 50 to 60 Hz +6% Power consumption 13.5 VA Duty cycle continuous Operating environment Ambient operating temperature 5 F to 140 F (-15 C to 60 C) Mounting position Any position Maximum inlet gas pressure Same as VG series Page 2

SKP25 U.. Pressure Regulating Gas Valve Actuators Technical Instructions Specifications, Continued Physical characteristics Weight Enclosure 3.5 lb (1.6 kg) NEMA 1, 2, 5 and 12 for indoor use NEMA 3, 3R, and 4 with optional AGA66 gasket Dimensions See Figure 4 Specification for valve bodies See gas valve Technical Instructions, P/N 155-512P25 Connections Conduit connection Two 1/2-inch NPSM threaded knock-outs Electrical connection Spring loaded terminals for 14 AWG wires Gas connection 1/4 NPT Air connection 1/4 NPT Gas pressure test connection Hose barb with close-off screw Operating characteristics Output force 100 lb (450 N) Maximum stroke 1 inch (26 mm) Opening time for maximum stroke Varies with valve size, 14 seconds for max. stroke Closing time < 0.8 seconds Operation/installation Outlet pressure spring range SKP25.0 0" to 8.5" WC (factory-installed, unpainted spring, AGA29) 6" to 48" WC (yellow spring, AGA22) 40" to 100" WC (red spring, AGA23) SKP25.411U1 SKP25.0 (1:1 air/gas ratio regulator or zero governor) 1.5 to 10 psi (factory-installed, yellow spring, AGA22) 8.5 to 20 psi (red spring, AGA23) ± 0.4" WC bias (replace with black spring AGA28) SKP25.611U1 (1:1 air/gas ratio regulator) 0" to 4.0" WC bias (factory installed, white spring) SKP25.011U1P 0 to 0.6 WC (factory installed, lavender spring) (1:1 air/gas ratio regulator) Maximum sensing line pressure 20 psi Maximum sensing line vacuum 3 psi for SKP25.0 models Minimum sensing line diameter 1/4" inside diameter Minimum distance between 5 times the pipe diameter sensing line and gas valve outlet Minimum time required for high to low fire 5 seconds load changes Auxiliary features Proof of closure switch Non-adjustable Setting range of auxiliary switch 40% to 100% of stroke Switch rating 6A/250 Vac resistive; 3A/120 Vac pilot duty Page 3

Technical Instructions SKP25 U.. Pressure Regulating Gas Valve Actuators Operation (See Figure 1) Safety Shut-off Function The electro-hydraulic actuator consists of a cylinder filled with oil, a piston containing an electric oscillating pump, and a relief system. When power is supplied to the actuator, the relief system closes, and the pump moves oil from the reservoir into the pressure chamber. This action causes the piston to move downward in the cylinder, opening the gas valve. When power to the actuator is interrupted, the relief system opens and the gas valve closes in less than 0.8 seconds. A position indicator, visible through the transparent portion of the terminal cover, shows the entire stroke range of the actuator. A light, which is visible through the lower left transparent portion of the terminal cover, indicates when the actuator receives power. An optional, non-adjustable SPDT proof of closure over travel switch signals the closed position after the gas valve has closed. An optional SPDT auxiliary switch is adjustable between 40% and 100% of the stroke. The adjustment screw and scale are located on the right side in the terminal box, and are visible through the transparent portion of the terminal cover. Gas Sensing Line - + P Gas GAS0062R1 Figure 1. SKP25 Operation. Constant Pressure Regulation Function (See Figure 1) The outlet gas pressure sensing line is connected to the 1/4 NPT port marked GAS on the back of the pressure regulator housing. The outlet pressure acts on the regulator diaphragm. The diaphragm is opposed by an adjustable setpoint spring force, which represents the desired gas pressure value. The movement of the diaphragm modulates a hydraulic bypass valve connecting the pressure chamber to the hydraulic fluid reservoir. When the outlet gas pressure is lower than the desired value, the bypass valve is closed by the movement of the diaphragm, causing the actuator piston to open the gas valve. The opposite occurs when the outlet gas pressure is higher than the desired value; the diaphragm moves to open the bypass causing the actuator piston to close the gas valve. The movement of the actuator piston stops once the outlet gas pressure is equal to the setpoint. In this position the bypass valve is partially open so that the oil flow supplied by the pump is identical to the return flow. Unlike the conventional direct acting regulators, the SKP25 servo operated regulating system displays virtually zero droop (offset) across the turndown range. Page 4

SKP25 U.. Pressure Regulating Gas Valve Actuators Technical Instructions Air/Gas Ratio Regulator Function The SKP25.0 models may be applied as a 1:1 air/gas ratio regulator or as a zero governor. For either application, the standard spring has to be replaced with the black AGA28 spring, which allows to bias the gas pressure between 0.4" and 0.4" WC. The low bias model SKP25.011U1P air/gas ratio regulator is designed as 1:1 air/gas ratio regulator which allows to bias the gas pressure between 0 and 0.6 WC. with the factory installed lavender spring. The actuator has a built in proof of closure switch. The high bias model SKP25.611U1 air/gas ratio regulator model is designed as 1:1 air/gas ratio regulator which allows to bias the gas pressure between 0 and 4 WC. with the factory installed white spring. The actuator has a built in proof of closure switch. For air/gas ratio regulation, the air pressure sensing line must be connected to the port marked AIR". Air Sensing Line Gas Sensing Line P Gas - bias + GAS0061R1 NOTES: Figure 2. SKP25 Operation as 1:1 Air/Gas Ratio Regulator. 1. The gas bias has the greatest effect at low fire. 2. To adjust the gas pressure or bias, remove the brass cap in the center of the regulator cover. 3. To increase the downstream gas pressure, turn the adjustment screw clockwise. 4. SKP25.4 models must not be used as air/gas ratio regulator. 5. When using the double valve VGD, mount the SKP2 on the downstream valve. 6. To avoid oscillation, do not oversize the VG valve body. (See Technical Instructions, P/N 155-512P25.) Page 5

Technical Instructions SKP25 U.. Pressure Regulating Gas Valve Actuators Installation WARNING: Personal injury or loss of life may occur if procedures are not followed as specified. All installations must be performed by qualified personnel only. Do not pull the actuator shaft. If minimum gas pressure detection is required, the pressure switch must be mounted upstream of the regulating gas valve to ensure sufficient gas pressure before starting the burner. If maximum gas pressure detection is required the pressure switch must be mounted downstream. The AGA66 gasket must be installed between the actuator and the gas valve body to provide NEMA 3, 3R, and 4 protection rating for VGG and VGD valves. The gas pressure sensing line must be at least 1/4-inch inside diameter. The gas pressure sensing line connection must be flush with the inner wall of the gas pipe in order to sense turbulence free pressure. The gas sensing line connection should be located at least five pipe diameters downstream of the valve, elbow, coupling, or other flow disturbing fitting. Do not use the taps on the valve body for the gas sensing line connection since these locations typically have strong turbulence. The pressure connection pipe should be as short as possible to allow the regulator to react to sudden changes. The SKP25 actuator is directly coupled to the VG series valve body by four pre-mounted 4 mm Allen key screws. The square mounting flange can be rotated in steps of 90 o to provide four different mounting positions. The SKP25 actuator can be mounted in any position with the diaphragm vertical, except upside down. The actuator can be mounted or replaced while the valve body is under pressure. The SKP25 actuator has two knock-outs for the installation of 1/2-14 NPSM conduit connections. When conduit routing is connected, flexible conduit must be used. Liquid tight conduit must be used in combination with AGA66 to provide NEMA 3, 3R, and 4 protection. The terminal marked GND, located above the wiring terminals, must be connected to the electrical ground. NOTE: Wiring must meet all relevant electrical codes. Page 6

SKP25 U.. Pressure Regulating Gas Valve Actuators Technical Instructions Start-up Regulator The gas outlet pressure setpoint adjustment screw is located at the center of the regulator cover. Clockwise rotation of the setpoint adjustment screw increases the outlet gas pressure. The hexagonal cap must be tightened after the setpoint screw has been adjusted and may be sealed from tampering by means of a wire and lead seal. The outlet gas pressure can be measured at the hose barb at the back of the regulator housing. Turn the screw 1/2 turn counterclockwise before attaching the hose and tighten the screw after removing the hose. The SKP25.0 models are available with three interchangeable setpoint springs for an adjustable range outlet pressure range of 0 to 100 WC. The factory-installed unpainted spring ranges from 0 to 8.5 WC. Other springs need to be ordered separately. (See Table 2.) The SKP25.411U models are available with two interchangeable setpoint springs for an adjustable range of 1.5 to 20 psi. The factory installed yellow spring ranges from 1.5 to 10 psi. The red spring (AGA23) for an adjustable range of 8.5 to 20 psi needs to be ordered separately. Air/Gas Ratio Regulators Wiring and Switch Adjustment (See Terminal Designations) For SKP25.0 models used as 1:1 air/gas ratio regulator connect the air sensing line to the port marked AIR and replace the factory installed spring with the black spring (AGA28) which needs to be ordered separately. The gas bias can be adjusted at the center of the regulator housing. For bias pressure ranges of all 1:1 air/gas ratio regulators see Operation, Specifications or Tables 1 and 2. WARNING: When firing at maximum burner capacity, ensure that the SKP25 /VG is not in the fully open position. If this is the case, either the gas valve is sized too small or the gas supply pressure is too low. The actuator is equipped with spring-loaded terminals for 14 AWG wires. The actuator has two line and two neutral terminals. Insert one wire into the opening of the terminal while pressing the lever downward with a screwdriver or hard object. Make sure that all strands insert into the opening. Adjust the auxiliary switch (if provided) according to the wiring diagram on the label below the terminals (see Figure 3). The adjustment screw and scale are located on the right side of the terminal box, and are visible through the transparent portion of the terminal cover. NOTES: 1. The auxiliary switch is adjustable between 40% and 100% of the stroke. The factory setting is at 40%. 2. The auxiliary switch must not be used for proof of closure detection or other safety interlock functions. 3. The Proof of Closure Switch is non-adjustable. Page 7

Technical Instructions SKP25 U.. Pressure Regulating Gas Valve Actuators Service Terminal Designations There are no serviceable parts on the SKP25 series actuators. If inoperative, replace the actuator. Tag wires before servicing. GAS0049R1 Dimensions SKP25.012U.. SKP25.011U.. SKP25.013U.. Figure 3. Terminal Designations. 1/4" FEMALE 3.78 (96) 1.30 (33) PRESSURE TEST PORT 0.35" (8.5) O.D. 1/4"-18 NPT FEMALE 1.02 (26) 1.41 (36) 8.70 (221) 7.95 (202) 7.87 (200) 1/2"-14 NPSM 6.61 (168) 3.82 (97) 3.15 (80) GAS0052R1 3.39 SQUARE (86) 3.20 (81) 2.16 (55) Figure 4. SKP25 U.. Dimensions in Inches, Millimeters in Parentheses. Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Other product or company names mentioned herein may be the trademarks of their respective owners. 2007 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 U.S.A. Your feedback is important to us. If you have comments about this document, please send them to SBT_technical.editor.us.sbt@siemens.com Document No. 155-752 Country of Origin: US Page 8