TF- & DM-Series. Turbineflowmeter

Similar documents
TF- & DM-Series. Turbine flowmeter

Turbine Flowmeters for Gas Applications

Turbine Flowmeters for Gas Applications

Turbine Flowmeters for Liquid Applications

Turbine Flowmeters for Gas Applications (Metric)

Turbine Flowmeters for Liquid Applications (Metric)

Technical Datasheet ZHA Series Gear Flow Meters Aluminum Version with ball bearing for lubricating media

ZHM ST Series. Technical Datasheet. Gear Flow Meters for lubricating, non lubricating, abrasive and corrosive fluids

SITRANS P measuring instruments for pressure

C-Flow Coriolis Mass Flow Meters

Flow metering in gases Introduction to COMBIMASS family

Omniflo. Turbine Flowmeters. Description. Features. Applications. Omniflo Turbine Flowmeters. Operation

deltaflowc deltaflowc Venturi or Probe

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Pressure Measurement Single-range transmitters for general applications

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Omniflo. Turbine Flowmeters. Description. Features. Applications. Operation. Omniflo Turbine Flowmeters

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Electronic Turbine Meter TERZ 94

Bourdon tube pressure gauge for diaphragm seals

AMS 2710 PCB pressure sensor module with V output

better measurement Simply a question of

Ultrasonic Flowmeter USZ 08

Flow Measurement SITRANS F C

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

RMG Meßtechnik GmbH. Publication No E

Operating Instructions DB41

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

ATM.ECO/IS - Analog Transmitter with Temperature compensation

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

ATM.1ST/Ex - High Precision Transmitter

MEDAP-MOBILE GAS SUPPLY

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

OPTIBAR P 1010 C Technical Datasheet

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

NivuBar Plus II

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

Measurement of Low GAS & Liquid Flows

Mass Flow Controller (MFC) for Gases

Pressure Measurement Single-range transmitters for general applications

780S Ultra High Purity Series

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

For the highest operational safety around the clock

Mass Flow Controller (MFC) for Gases

VA40 - VA45 Technical Datasheet

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Torque Tube TB300 Digital Transmitters

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

RCD - Ultra-Rugged Differential Pressure Flowmeter

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Pro-V Multivariable Flowmeter

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Optimum oxygen supply for your patients! ATMOS Oxygen Supply

Description Advanced Features Typical Applications

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Valvex Valves for Mining Applications

Instruction Manual SB02, SB03, SB04 All metal flow limiter

Level transmitter LT 100

LUGB Vortex Flowmeter

AMS 6916 Board mount pressure sensor with ratiometric analog output

P900. P900, Datenblatt Seite 1 DESCRIPTION

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

BY GREGGERSEN CATA LOG

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

High-performance submersible pressure transmitter For level measurement Model LH-20

Monitoring device NTS 30

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Differential pressure

Integral type Differential pressure flowmeter VNT Series

Process Solutions. Electronic Turbine Meter TERZ 94 PROVEN TECHNOLOGY. SUPERIOR PERFORMANCE.

FAS-W. Features. Applications. Automatic condensation hygrometer

For Multi-Parameter Meters see mvx

Mass Flow Meter (MFM) for Gases

MEDAP-FLOWMETERS FOR OXYGEN AND COMPRESSED AIR

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

Transcription:

Turbineflowmeter

.. are the ideal solution for measuring applications in liquids when high accuracy, very fast response times, compact design, high reliability are also required in continuous operation and flow changes at fluctuating operating temperatures. A variety of selectable connections allows the measuring instruments to be used as required. Applications The TF- & DM-Series turbine flowmeters have a wide range of applications. These include i.a. Monitoring of flow rates of fuels and coolants and lubricants in engine and engine construction, measurement of dosing quantities in the food and pharmaceutical sector, monitoring and measurement of high-purity water in the research and development sector, quantity measurement for consumption calculations and much more. Advantages New helical rotor blades design for improved linearity and lower pressure loss. Interference-free signal transmission by digital output signal. Precision ball bearings for better repeatability and optimum results at low flow rates. Very large measuring range. Integrated temperature sensor in the sensor (pickoff). Flow meter manufacture As a specialist in flow measurement technology, TrigasDM supplies high-quality measuring instruments, electronics and calibrators for liquids and gases. Made in Germany Our products are exclusively developed and manufactured in Neufahrn, 20 km north of Munich, ensuring world-class technical know-how for our customers. Contact We are proud of our high-quality products and friendly customer service and welcome you as a valued customer to our growing family. You can benefit from our long-standing experience and our comprehensive technical support. TrigasDM GmbH Tel.: +49 8165 9999-300 Erdinger Str. 2b Fax: +49 8165 9999-369 E-Mail: info@trigasdm.com 85375 Neufahrn, Germany www.trigasdm.com TrigasDM GmbH 2017-07 2

Technical data Flow range: see "Measuring ranges" table Response time: <3 ms Temperature range: TF-Series -270 C up to 150 C DM-Series -270 C up to 400 C Operating pressure: up to 540 bar depending on connection AN: up to 540 bar HS: up to 34 bar Tri-Clamp: up to 50 bar Viscosity: Each turbine is calibrated according to customer specifications and delivered with individual calibration protocols. (Standard viscosity: 1.3 mm²/s) Calibration accuracy: ±0.03% of reading Repeatability: ±0.05% of reading Linearity: ±0.5% of reading value in the linear flow range ±0.1% with linearization electronics Standard material: Stainless steel Measuring ranges Linear Range Extended Flowrange K-Faktor 1) max. Frequency 1) [l/min] [l/min] [Impulse/l] [Hz] RF 2) und Mag 3) RF 2) Mag 3) Alle Model min. max. min. min. max. DM2-8 0,5 4) 5 4) 0,05 0,8 5,5 22600 2300 TF/DM4-8 0,95 12 0,1 0,4 13 8700 1950 TF/DM6-8 1,9 20 0,2 0,5 24 4860 2000 TF/DM8-8 2,8 33 0,3 0,6 38 3720 2100 TF/DM-08 3,0 40 0,4 0,8 48 2450 1950 TF/DM-10 4,5 60 0,6 1,1 70 1710 2000 TF/DM-12 7,6 90 0,9 1,9 95 1260 2000 TF/DM-16 19 220 2,2 3,8 240 550 2200 TF/DM-20 34 400 3,8 6,0 490 245 2000 DM-24 57 700 6,0 10 820 110 1500 DM-32 83 1100 10 13 1300 65 1400 DM-40 151 1510 17 19 1700 48 1200 1) The K-factors and frequency data are average values. Each turbine is calibrated according to customer specifications and delivered with individual calibration protocols. 2) RF = Frequency-modulated pickoff 3) Mag = Magnetic pickoff 4) DM2-8 ±2% of reading TrigasDM GmbH 2017-07 3

Dimensions Other end fittings are available upon request. TF- & DM-Series AN-Housing Inner Tube Ø Housing [mm] Connection Ø AN-Size Pickoff Model [mm] A B C ["] t [mm] Thread DM2-8 7,6 62,2 25 / 25 ¾ -16UNJF-3A 1/2 7,7 TF/DM4-8 7,6 62,2 25 / 25 ¾ -16UNJF-3A 1/2 7,7 TF/DM6-8 9,4 62,2 25 / 25 ¾ -16UNJF-3A 1/2 7 TF/DM8-8 10,2 62,2 25 / 25 ¾ -16UNJF-3A 1/2 6,7 TF/DM-08 11,2 62,2 25 / 25 ¾ -16UNJF-3A 1/2 6,2 TF/DM-10 12,8 69,1 SW 36 7/8-14UNJF-3A 5/8 10,6 TF/DM-12 14,3 82,6 SW 36 1-1/16-12UNJ-3A 3/4 9,5 TF/DM-16 21,9 90,4 SW 41 1-5/16-12UNJ-3A 1 8,1 TF/DM-20 25,4 103 SW 50 1-5/8-12UNJ-3A 1 1/4 10,3 DM-24 33,4 116,6 SW 55 1-7/8-12UNJ-3A 1 1/2 8,9 DM-32 44,5 154,0 SW 70 2-1/2-12UNJ-3A 2 10,4 TF- & DM-Series HS-Gehäuse Inner Ø Housing [mm] Connection Pickoff Model [mm] A B C t [mm] Thread DM2-8 7,6 62,2 22 / 17 9,5 7,2 TF/DM4-8 7,6 62,2 22 / 17 9,5 7,2 TF/DM6-8 9,4 62,2 25 / 25 12,7 6,6 TF/DM8-8 10,2 62,2 25 / 25 12,7 6,2 TF/DM-08 11,2 62,2 25 / 25 12,7 5,7 TF/DM-10 12,8 69,1 26 / 22 15,9 10,1 TFDM-12 14,3 82,6 26 / 22 19,1 7,0 TF/DM-16 21,9 90,4 33 / 25 25,4 5,7 TF/DM-20 25,4 103,0 43 / 27 31,8 10,4 DM-24 33,4 116,6 50 / 24 38,1 8,9 DM-32 44,5 154,0 63 / 24 50,8 10,4 DM-40 59,7 128,0 Ø 85 64,0 8,1 The total height is calculated from the height (B) of the flow meter plus measuring element minus the screw-in depth (t). TrigasDM GmbH 2017-07 4 DM-Serie 5/8-18UNF-2B DM-Serie 5/8-18UNF-2B TF-Serie 11/16-24NEF-2B TF-Serie11/16-24NEF-2B

Pressure drop Subsequently, the pressure losses at different flow rates are listed. Pressure drop [bar] % of the max. linear flow 10% 25% 40% 55% 70% 85% 100% Model DM2-8 0,00 0,01 0,03 0,05 0,08 0,11 0,15 TF/DM4-8 0,01 0,03 0,06 0,16 0,19 0,27 0,35 TF/DM6-8 0,01 0,02 0,06 0,11 0,16 0,23 0,32 TF/DM8-8 0,01 0,05 0,11 0,20 0,30 0,46 0,61 TF/DM-08 0,01 0,03 0,08 0,14 0,21 0,29 0,36 TF/DM-10 0,06 0,12 0,23 0,41 0,61 0,92 1,22 TF/DM-12 0,06 0,13 0,24 0,42 0,64 0,93 1,22 TF/DM-16 0,06 0,09 0,16 0,27 0,39 0,57 0,74 TF/DM-20 0,06 0,13 0,24 0,43 0,62 0,96 1,31 DM-24 0,07 0,16 0,32 0,60 0,89 1,32 1,74 DM-32 0,07 0,08 0,14 0,24 0,34 0,51 0,66 DM-40 0,03 0,06 0,13 0,21 0,40 0,45 0,61 Max.operating pressure Max.operating pressure [bar] Model AN HS DM2-8 540 34 TF/DM4-8 540 34 TF/DM6-8 450 34 TF/DM8-8 410 34 TFDM-08 410 34 TF/DM-10 410 34 TF/DM-12 410 34 TF/DM-16 350 34 TF/DM-20 350 34 DM-24 250 34 DM-32 250 34 DM-40 N/A 34 TrigasDM GmbH 2017-07 5

Piping Configuration Turbine flow meters can be affected by the velocity profile of the fluid being measured. Installation with proper pipe runs will reduce or completely eliminate flow profile induced measurement errors during calibration and operation. A straight run of pipe of at least 10 times the pipe diameter in an upstream direction, and 5 times the pipe diameter in a downstream direction are recommended (see figure and table). The upstream section should be fitted with flow straightening vane. Appropriate flow straightening sets (up- and downstream) are available on request. Inlet section and outlet section, schematic diagram Contamination / filter All pipe sections and components in the metering line must be cleaned prior to the installation of the flow meter. Pipe Sealants, metal shavings and slag can damage the flow meter. If the cleanliness of the fluid cannot be guaranteed, a filter should be installed upstream of the flow meter, subject to the diameter of the flow meter. Model Inner Ø [mm] Filter mesh width DM2-8 7,6 10 Mikrometer TF/DM4-8 7,6 10 Mikrometer TF/DM6-8 9,4 10 Mikrometer TF/DM8-8 10,2 10 Mikrometer TFDM-08 11,2 10 Mikrometer TF/DM-10 12,8 10 Mikrometer TF/DM-12 14,3 10 Mikrometer TF/DM-16 21,9 20 Mikrometer TF/DM-20 25,4 20 Mikrometer DM-24 34,4 50 Mikrometer DM-32 44,5 50 Mikrometer DM-40 59,8 50 Mikrometer TrigasDM GmbH 2017-07 6

Explosion protection (ATEX) Pickoffs and electronics can be supplied in explosion proof versions (ATEX) on request. With explosion proof electronics, TrigasDM turbine flow meters can be used in environments as severe as Ex-Zone 1. The design consists of the turbine flow meter and the ATEX Pickoff. The following type of protection applies to this construction: ATEX: USA: Canada: II 1 G Ex ia IIC FM08ATEX0066X Intrinsically Safe Class I, II, III, Division 1 GROUP ABCDEFG Class I, Zone 0, AEX ia IIC Intrinsically Safe Class I, Division 1 GROUP ABCD Class I, Zone 0, AEX ia IIC The turbine flow meter is installed in the hazardous area. The mounting of the barrier and the TriLIN is carried out in the safe area. Without barriers, the turbine flow meter must not be operated in the hazardous area. Cable lengths of up to 400 m are possible depending on the safety barrier used. TrigasDM GmbH 2017-07 7

Model numbering key The type number describes the properties of the measuring instrument. Model numbering key TF- & DM-Series (f.e. DM-16AN-BC-1-S) DM -16 AN -BC -1 -S Model DM = DM-Series TF = TF-Series Base Model 2-8 = iø 7,6 mm 4-8 = iø 7,6 mm 6-8 = iø 9,4 mm 8-8 = iø 10,2 mm -08 = iø 11,2 mm -10 = iø 12,8 mm -12 = iø 14,3 mm -16 = iø 21,9 mm -20 = iø 25,4 mm -24 = iø 33,4 mm -32 = iø 44,5 mm -40 = iø 59,7 mm Configuration -S = Standard -L = Lightweight construction -K = Lightweight short version Construction Material -1 = Stainless Steel Bearing -BA = Ball Bearing, Standard -BC = Ball Bearing, Ceramic End Fitting AN = AN thread connection HS = Hose Barb NE = NPT thread connection T1 = Tri-Clamp ½ ¾ T2 = Tri-Clamp 1" - 1 ½ T3 = Tri-Clamp 2 T4 = Tri-Clamp 2 1/2" TrigasDM GmbH 2017-07 8

Model numbering key Pickoff (f.e. R07C3T) R 01 C3 O Temperature Sensor T = Integrated in Pickoff 0 = without Connector C2 = MS Connector 2 Pins C3 = MS Connector 3 Pins C4 = MS Connector 4 Pins L1 = 1m cable outlet L3 = 3m cable outlet L5 = 5m cable outlet Thread 01 = 5/8-16, High Profile 02 = 5/8-16, Low Profile 03 = 5/8-16, High Profile, Explosion Proof 04 = 5/8-16, High Profile, High Temp. 06 = 11/16-24, High Profile 07 = 11/16-24, Low Profile 08 = 11/16-24, High Profile, Explosion Proof 09 = 11/16-24, High Profile, High Temp. Model R = Modulated Carrier (RF) M = Magnetic (Mag) L = Lysis SMART-RF A = Amplified (TTL) TrigasDM GmbH 2017-07 9