R-410A 50% R-32 50% R-125.

Similar documents
Qwik System Flush Air Conditioning & Refrigeration System Flush

COMPRESSOR REPLACEMENT PROCEDURE (R-134A)

OPERATING INSTRUCTIONS

POWER FLUSH KIT INSTRUCTIONS

Technology issues regarding Blends of Refrigerants Buffalo Research Laboratory

System Flush. Qwik. Air Conditioning & Refrigeration. System Flush. System Flush QT1100, QT1130, & QT1150. Oil Absorption* Moisture Absorption*

Capacity and pressure similar to R-507. Flooded systems. Low temperature (-46.7 C). R22 replacement as long as the condenser has the right size.

AE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions

Application Engineering Bulletin AE-1301 Issued June, Copeland APPLICATION GUIDELINES FOR ZP**K*E SCROLL COMPRESSORS FOR R-410A

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

Soft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II

Application Guideline. R410A Air Conditioning Scroll

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

RG6000. Refrigerant Recovery Machine. Operating Manual. 99 Washington Street Melrose, MA Phone Toll Free

Troubleshooting Guide. Pg. 1

A/C SYSTEM DIAGNOSIS

Refrigerant Recovery System Model 3600 Part No

Quick Start SunPump Install

Chapter 13 Selection and Safe usage of cleaning solvents

Maximum Weight of Racks* P67 P90 P120 P140 P160 P180 3,800# 4,400# 5,500# 6,100# 7,000# 7,900#

TP-MM1 Refrigerant Recovery Machine

Model 3600-R410A. Part No Instruction Operation & Maintenance

Vortex Dual. Refrigerant Recovery Machine

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

Genetron Performax LT Refrigerant. Properties, Guidelines and Retrofits

ATL R/V Atlantis AUXILIARY PLANT OPERATION APPENDIX OPERATING PROCEDURES

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

OPERATION MANUAL NTF-15

Fieldpiece. Refrigerant Recovery Machine OPERATOR'S MANUAL. Model MR45

Fieldpiece. Refrigerant Recovery Machine OPERATOR'S MANUAL. Model MR45

OPERATION MANUAL NTF-60 Plus

WHP Operations and Methods { July William M. Smethie, Jr. Lamont Doherty Geological Observatory Palisades, New York U.S.A.

USERS OPERATING MANUAL MINIMAX-E

The a. in retrofit applications. Such a retrofit may come under. takes a look at. work, which could cause expensive down time.

RecoverXLT2-AP Oil-Less Universal Refrigerant Recovery System Operation and Maintenance Manual

Using P-T Analysis As A Service Tool

KKT Training Series: ECO Series, Preventative Maintenance

CLOSED LOOP SOLVENT EMISSIONS CONTROL. David C.H. Grant

2 Sentry MCL Installation, Operation & Maintenance

NITROGEN PURGING SYSTEMS FOR THE HVAC INDUSTRY VISION INNOVATION SOLUTION

STANDARD PROCEDURE FOR THE REPLACEMENT OF COMPONENTS IN A SEALED REFRIGERANT SYSTEM (Compressor Failure and Replacement)

D A T A S H E E T. Technical Data. Maximum Working Gauge Pressure (bar) Capillary Tube Length (m) 1.5 (5Ft) Burst Gauge Pressure (bar) 234.

Official Journal of the European Union L 92/3

Operation and Maintenance Manual

GAS COMPRESSION SYSTEM

RecoverXL and RecoverXLT Oil-Less Universal Refrigerant Recovery Systems Operation and Maintenance Manual

Genetron Performax LT Refrigerant. Properties, Guidelines and Retrofits

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.

Refrigeration Scroll For Parallel Applications

ACCU-PULSE Installation and Operation Instructions

BEFORE HANDLING REFRIGERANTS, READ MATERIAL SAFETY DATA SHEET FROM REFRIGERANT MANUFACTURER.

Pub.No Flushing out your heat transfer system was a dirty job, a big expense, and a serious bummer.

EU minimum requirements. Training and certification for personnel and companies

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Zebron Gas Management

General Precautions for handling compressed gases

REDI CONTROLS, INC. Model RS-503/13-C3. RECOVERY SYSTEM for Very High Pressure Refrigerants R-13, R-23, R-503, & SUVA-95

R E D I C O N T R O L S

Adsorption Unit Operating Procedures: CO2 Adsorption on to Activated Carbon

Section 3- Repair and Calibration Procedures

System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner

Design Change Notification

Reliable System Performance PM valves

SAFETY TRAINING LEAFLET 06 CARBON DIOXIDE

Oxygen Contamination

Portable Oil Lube Air Compressors

Low GWP Refrigerants. Guidance on minimum requirements for contractors training & certification

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

4SCU 16/18LS SERIES Split System Air Conditioner

Dilution Refrigerator manual

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

JAVAC EVO-HS REFRIGERANT RECOVERY MACHINE

BIMA cryogenics (Dick Plambeck, 18jan2007)

Product Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)

Right-Angle Tube Roller Model

Capacities Valve Station, type ICF 15, 20, 25

Do-It-Yourself HVAC Apprentice Contest

OPERATING MANUAL LO-CROSS-FLOW CF M

Safety Information. Safety Notice. Read All Instructions. For your safety, read this manual thoroughly before operating your DUAL 3412 unit.

REFRIGERATION SYSTEM COMPONENTS

Mechanical Seal Piping Plans

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Lubricating Oils Hydraulic Oils Turbine Oils Cutting and Cooling Mineral Oils Compressor Oils Synthetic Fluids Insulating Oils Quenching Oils

LGSS Liquefied Gas & VSS Vapor (Gas) LGSS VSS LGSS. Features and Benefits

OX SCFH Oxygen Concentrator. Installation and Operation Manual

The Helium Leak Detector

PARALLELING OF COPELAND SCROLL COMPRESSORS

KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS

Low GWP R-404A Alternatives for Commercial Refrigeration. Barbara H. Minor Dr. Frank Rinne DuPont Fluorochemicals

Improve Reliability of Turbomachinery Lubrication and Sealing Systems

Pressure Regulators. Operating Instructions. Instrumentation

SURFACE VEHICLE STANDARD

RecoverXLT Oil-Less Universal Refrigerant Recovery System. (For serial numbers and higher)

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Transcription:

R-410A

R-410A Facts Ozone friendly- No Chlorine Replacement for R-22, NOT a drop in! Higher Pressure Range-50 to 75% higher than R-22 Requires Special Lubricants

R-410A It s a Blended Refrigerant. 50% R-32 and 50% R-125. This blend is a near-azeotrope, not a true azeotrope like R-502. A true azeotrope is a mixture that maintains its composition through both the liquid and vapor phase.

The Future Refrigerant R-410A Azeotrope/Near Azeotrope Temperature Glide Fractionation The Future Refrigerant R-410A

R-410A For a near-azeotrope, the individual refrigerants evaporate or condense at different temperatures. The differences between these saturation temperature points with mixed refrigerants is called: TEMPERATURE GLIDE When temperature glide is high the refrigerants can separate during evaporation or condensation. This changes the composition of the resulting vapor and liquid. This separation is called: FRACTIONATION

R-410A The temperature glide of R-410A is very low, thus it acts very much like a single refrigerant. Fractionation is very low. R-410A does not significantly separate in the system and the composition of the refrigerant has very minor changes if a leak occurs. But the fact that some fractionation occurs, means that charging techniques must be adjusted.

R-410A Another significant difference between R-410A and R-22 is its saturation pressure range. R-410A has a higher pressure range curve than R-22. Remember, R-410A is a near azeotrope that is subject to some fractionation. At any specific temperature it has a higher vapor pressure than R-22 when saturated.

Expanded Cooling Data

Components that needed to be redesigned for R-410A Compressor Condenser Coil Filter Drier Expansion Device Evaporator Pressure Switches

Compressors Copeland Compressors R 410a ZP or ZPS R 22 ZR or ZRS

Pressure Switches Pressure Switches have to be at higher settings Low Pressure R-410A = 50psi High Pressure R-410A = 610psi

What Should Be None If Using Old R 22 Line Set Cut and remove old equipment Remove any old oil traps Blow through the line set forward and backward Use some type of flush like RX 11 Braze in new equipment with dry nitrogen

What Happens If Line Set Is Not Cleaned Clogs Filter/Driers Damages Reversing Valves Clogs Metering Devices Flowrators, TXV Mixes With POE Oil/ Low Miscibility Does Not Lubricate System Compressor Bearing Surface Not Lubricated

Mineral Oil Sludge clogging a R410a TXV Clogged TXV s

Using Existing Line Sets This TXV was removed from a R410A replacement installation that failed shortly after startup. The dealer did not clean the existing line set and did not bleed nitrogen thru the system during brazing. R410A is a very good solvent and will wash all contamination into the TXV, filter drier and on heat pump the reversing valve pilot tubes.

Clogged Filter Desiccant Full

Leak Detectors Leak detectors should be checked to see that they are designed to properly detect R410A. The detector should have adjustable sensitivity to allow leaks to be pinpointed in areas where background vapor might cause false readings.

Refrigerant Hoses The 600psi rating of standard hoses is NOT adequate for R410A. Hoses need to be rated for a 800psi working pressure, with a 4000psi bursting rating. A 5 to 1 safety margin is necessary to prevent dangerous hose ruptures.

Cylinders Most R-410A cylinders have an internal dip tube which allows the feeding of liquid when the cylinder is in an upright position. They must be inverted for for vapor flow. Color is rose (pink). The cylinder has to have minimum cylinder pressure requirement of 400 psig rating (DOT 4B400 or DOT 4BW400) NOTE: Avoid storing R-410A where temperatures will exceed 120 F.

Charging Charge through the suction side of the system. Use a commercial-type metering device in manifold hose to allow liquid to vaporize. Follow your typical sub-cooling or superheat procedures to arrive at the correct charge.

R-410A Gauges With Sight Glass R-410A Gauges Dedicated charge hoses Dedicated manifold R-410A hoses rated up to 550 to 800 PSIG

Manifold Gauge Set

Insta Charge

Lubrication The chemistry of R-410A makes it incompatible with mineral based lubricants. Mineral oils typically used with R-22 has relativity low Miscibility with R-410A. Miscibility is the ability of an oil to dissolve uniformly in refrigerant in either the liquid or vapor state.

Lubrication The POE oils are more Hygroscopic than mineral oils. This means that they absorb moisture very rapidly. Exposure to the atmosphere must be limited. The oil will break down into acid and alcohol. Keep the system closed.

PolyolEster Oil (POE)

Lubrication Any moisture absorbed by into POE oils cannot be removed with a vacuum pump-only a new drier will work! Break a recovery vacuum with Nitrogen! Keep all systems closed until any component replacements are ready for installation.

Filter, Sight Glass and Isolating Valves Liquid Line Filter Isolating Valve Quick Connect Flare Fittings Liquid Line Sight Glass With Moisture Indicator

Retrieval Machine with Oil Less Compressor