MANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE

Similar documents
MANUAL: Jumbo Siamese and Jumbo Wye

MANUAL: LDH GATED WYE

MANUAL: Jumbo Gate Valve

MANUAL: LDH GATED WYE

MANUAL: 5-WAY MANIFOLD

MANUAL: SHO-FLOW Flow Meter Operations

MANUAL: OASIS HYDRANT ASSIST VALVE

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

MANUAL: Low Profile Ball Intake Valve

MANUAL: PROTECTOR STATION MONITOR

MANUAL: LDH VALVED APPLIANCES

MANUAL: HYDRANT MASTER

MANUAL: EF1 RC MONITOR

Manual: GPK1 - Gin Pole Kit Accessory for the ARRS1-AMKUS Rope Rescue System

MANUAL: LDH VALVED APPLIANCES

FOR SAFE OPERATION AND MAINTENANCE

FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation

INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE. Monitor Mounted Operator Station SECTION 4.2. Tethered Operator Station (Y4E-CT-##)

MANUAL: BLITZFIRE Portable Monitor Series

Model ASSEMBLY and OPERATING INSTRUCTIONS

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

CROSSFIRE MANUAL: WITH SAFE-TAK 1250 BASE INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE DANGER. TASK FORCE TIPS, Inc. DANGER

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE

MANUAL: CROSSFIRE Monitor With Stow-A-Way 800 Base

MANUAL: BLITZFIRE Portable Monitor Series

Yoke Block Instruction Manual

AIR INLINE METAL SHEAR

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

Geotech 1.66 Reclaimer

COMPACT METAL bender 99826

2000 lb manual winch

Geotech 1.66 Reclaimer Installation and Operation Manual

6 digital caliper with case

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Geotech 3.5 Reclaimer Installation and Operation Manual

WARNING. Service Procedure: ION OIL FILL PROCEDURE LEVEL 3 TOOL REPAIR. AMKUS RESCUE SYSTEMS

Pressure Relief Valve Instruction Manual

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

User Instruction Manual

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

HYDRAULIC WINCH FOR AUGERS UP TO WR10 X 71 / W130 X 41 ASSEMBLY & OPERATION MANUAL

Sunset Swings By Health in Motion, LLC

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

4-in-1 Professional Inflator Kit

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

D Series Air and Water Kit Part# 02550

Cylinder Tilt Saddle Instruction Manual

MANUAL: CROSSFIRE Monitor

DANGER. AMK-100R LIFTING JACK User Information Manual DANGER. AMKUS RESCUE SYSTEMS

Cocoa Patio Pond with Lit Spillway

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

Owner s Manual Tourmaster Storage Cart

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

J Air and Water Kit Instructions Part# 02584

CSA Sample Draw Aspirator Adapter Operator s Manual

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

FLANGED TWO-PIECE BALL VALVES

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Vessel Installation and Operating Manual

4 and 8 Station PDS Control Installation & Operators Manual

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

FLANGED TWO-PIECE BALL VALVES

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Paintball Marker. User s Manual. Direct Feed. SC: Stock Class. VSC: Vertical Air Stock Class. 530 South Springbrook Road Newberg, OR 97132

Operating Instructions Model and Hydrostatic Test Pump

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Yoke Block Instruction Manual

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

VL PONTOON/TRITOON DECK BRACKET 13 INSTRUCTIONS

Offset head dual chuck

Instruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.

Installation and Operating Manual

Portable Compressed CO 2 Regulator

Operating Instructions Model and Hydrostatic Test Pump

Angled Sign Light with Shade

Owner s Manual & Safety Instructions

Model Portable Eyewash

TactAir PCP Fill Kit/Adapter. Operation Manual

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

Index Table. Model 794. Installation, Operating and Maintenance Instructions

HYDRAULIC PUNCH DRIVER 38456, 38520, 7306 / 7306SB, 7310 / 7310SB, 7506, 7606SB, 7610SB, 7625 / 7625Pg / 7625PgSB, 7646 / 7646Pg / 7646PgSB

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

CS150 CAP STAPLER OWNER S MANUAL

FLANGED MULTI-PORT BALL VALVES

GALISO SOAP OPTION FOR PCT-ADW-D

H4802, H4802-1, H , and Pole Tampers

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

12 Inch Barn Light. Owner s Manual

WHEATLEY Series 822/820 Swing Check Valve

Transcription:

MANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE WARNING Understand manual before use. Operation of this device without understanding the manual and receiving proper training is a misuse of this equipment. Obtain safety information at www.tft.com Operation Range: Pressure Max 300 PSI (20bar) Hydrostatic Proof Test: 900 PSI (62bar) per NFPA 96 TASK FORCE TIPS, INC. MADE IN USA www.tft.com 370 Innovation Way, Valparaiso, IN 6383-9327 USA 800-38-2686 29-62-66 Fax 29-6-7

DANGER PERSONAL RESPONSIBILITY CODE The member companies of FEMSA that provide emergency response equipment and services want responders to know and understand the following:. Firefi ghting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme caution at all times. 2. It is your responsibility to read and understand any user s instructions, including purpose and limitations, provided with any piece of equipment you may be called upon to use. 3. It is your responsibility to know that you have been properly trained in Firefi ghting and /or Emergency Response and in the use, precautions, and care of any equipment you may be called upon to use.. It is your responsibility to be in proper physical condition and to maintain the personal skill level required to operate any equipment you may be called upon to use.. It is your responsibility to know that your equipment is in operable condition and has been maintained in accordance with the manufacturer s instructions. 6. Failure to follow these guidelines may result in death, burns or other severe injury. FEMSA Fire and Emergency Manufacturers and Service Association P.O. Box 7, Lynnfi eld, MA 090 www.femsa.org 2

.0 MEANING OF SAFETY SIGNAL WORDS A safety related message is identifi ed by a safety alert symbol and a signal word to indicate the level of risk involved with a particular hazard. Per ANSI standard Z3.6-20, the defi nitions of the four signal words are as follows: DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING CAUTION NOTICE WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE is used to address practices not related to physical injury. 2.0 SAFETY WARNING WARNING CAUTION NOTICE The appliance may be damaged if frozen while containing significant amounts of water. Such damage may be difficult to detect visually and can lead to possible injury or death. Any time the appliance is subject to possible damage due to freezing, it must be hydrostatically tested by qualified personnel before being considered safe for use. This equipment is intended for use by trained personnel for fire fighting. Use for other purposes may involve hazards not addressed by this manual. Seek appropriate guidance and training to reduce risk of injury. Dissimilar metals coupled together can cause galvanic corrosion that can result in the inability to unscrew the threads and complete loss of thread engagement over time. Per NFPA 962 (203 edition), if dissimilar metals are left coupled together an anti-corrosive lubricant should be applied to the threads. Also the coupling should be disconnected and inspected at least quarterly. To prevent mechanical damage, do not drop or throw equipment. 3

3.0 GENERAL INFORMATION The Task Force Tips In-line Pivot Pressure Gauge is designed for use on standpipes, truck outlets, on the ground, or where having a pressure reading is advantageous. The In-line Pivot Pressure Gauge incorporates a liquid fi lled pressure gauge with an easy to read gauge face into a solid aluminum body, protecting the gauge from damage. Built into the casting is a pitot pickup for an accurate reading of the total pressure in the center of the waterway. The gauge also includes a replaceable lens that protects the gauge face from damage. The lens can easily be changed if it becomes scratched or damaged. The outlet is available with a pivoting joint that moves ±20 from center for controlling hose kinks on standpipes with horizontal or vertical discharge. Pivoting outlets cut the weight of hi-rise packs by eliminating a separate elbow. Fully pivoting the discharge changes the gauge reading by less than PSI (0.3 bar) at 00 GPM (2000 L/min). Models with a rigid outlet (non-pivoting) are useful for straight in-line applications. A full time swivel coupling allows the gauge face to be rotated into any direction while in use, allowing the gauge to be seen at all times. An optional drain valve can be purchased to also use as a pressure or air bleed (A62-KIT) when needed. A cap and tether can also be purchased and added to protect the outlet threads when required. 6." [62mm] 3.9 [00mm]. [0mm] Straight Configuration Rigid Outlet (Non Pivoting) 8.0" [20mm].8 [7mm].7 [20mm]. [0mm] 20 20 Pivoting Outlet Shown With Optional Drain/bleed Valve Figure 3.0 Gauge Dimensions

.0 EXPLODED VIEW AND PARTS LIST. PIVOT IN-LINE PRESSURE GAUGE EXPLODED VIEW PARTS LIST 7 Serial Number 8 9 0 2 3 6 2 3 A 7 6 INDEX DESCRIPTION QTY. PART # GASKET - 2." HOSE COUPLING V390 2 COUPLING 2."F P97* 3 /-28 X / SOCKET SET SCREW VT2-28SS20 3/6" SS BALL 8 V220 O-RING- VO- 6 IN-LINE GAUGE BODY J20 7 IN-LINE GAUGE COVER J260 8 0-32 X / BUTTON HEAD SCREW 2 VT0-32BH20 9 GAUGE LENS J262 0 PRESSURE GAUGE: 200PSI/ BAR J26 PRESSURE GAUGE: 300PSI/2 BAR J266 O-RING-08 VO-08 2 IN-LINE GAUGE NAME LABEL J263 3 O-RING-23 VO-23 EXIT 2."M XX30* WAVE SPRING WASHER 2 VW70X0-6 6 SWIVEL TRUNNION 2 XX320 7 3/"NPTM HEX SOCKET PLUG XG0 A DRAIN VALVE SUBASSEMBLY A62 * - CONSULT FACTORY FOR SPECIAL THREADS

.2 STRAIGHT IN-LINE PRESSURE GAUGE EXPLODED VIEW AND PARTS LIST 7 Serial Number 8 9 0 2 3 6 2 3 A INDEX DESCRIPTION QTY. PART # GASKET - 2." HOSE COUPLING V390 2 COUPLING 2."F P97* 3 /-28 X / SOCKET SET SCREW VT2-28SS20 3/6" SS BALL (8 PER COUPLING RACE) 9 V220 O-RING- 2 VO- 6 IN-LINE GAUGE BODY J2 7 IN-LINE GAUGE COVER J260 8 0-32 X / BUTTON HEAD SCREW 2 VT0-32BH20 9 GAUGE LENS J262 0 PRESSURE GAUGE: 200PSI/ BAR J26 PRESSURE GAUGE: 300PSI/2 BAR J266 O-RING-08 VO-08 2 IN-LINE GAUGE NAME LABEL J263 3 SPOUT HSBGM30 X 2."M A77* /-28 X /2 SOCKET SET SCREW VT2-28SS00 3/"NPTM HEX SOCKET PLUG XG0 A DRAIN VALVE SUBASSEMBLY A62 * - CONSULT FACTORY FOR SPECIAL THREADS 6

.3 AIR VENT/DRAIN VALVE [A] VIEW AND PARTS LIST 2 3 A62-KIT 6 7 8 INDEX DESCRIPTION QTY. PART # /2" BARB X /"NPTM NIPPLE XX329 2 FOLLOWER U2 3 3/8-2 X 3/8 DOG POINT H DRAIN HOUSING A3 O-RING 2 VO- 6 DRAIN SLEEVE A 7 O-RING-0 VO-0 8 DRAIN LEVER A2 7

.0 WARRANTY Task Force Tips, Inc., 370 Innovation Way, Valparaiso, Indiana 6383-9327 USA ( TFT ) warrants to the original purchaser of its inline pressure gauge ( equipment ), and to anyone to whom it is transferred, that the equipment shall be free from defects in material and workmanship during the fi ve () year period from the date of purchase. TFT s obligation under this warranty is specifi cally limited to replacing or repairing the equipment (or its parts) which are shown by TFT s examination to be in a defective condition attributable to TFT. To qualify for this limited warranty, the claimant must return the equipment to TFT, at 370 Innovation Way, Valparaiso, Indiana 6383-9327 USA, within a reasonable time after discovery of the defect. TFT will examine the equipment. If TFT determines that there is a defect attributable to it, TFT will correct the problem within a reasonable time. If the equipment is covered by this limited warranty, TFT will assume the expenses of repair. If any defect attributable to TFT under this limited warranty cannot be reasonably cured by repair or replacement, TFT may elect to refund the purchase price of the equipment, less reasonable depreciation, in complete discharge of its obligations under this limited warranty. If TFT makes this election, claimant shall return the equipment to TFT free and clear of any liens and encumbrances. This is a limited warranty. The original purchaser of the equipment, any person to whom it is transferred, and any person who is an intended or unintended beneficiary of the equipment, shall not be entitled to recover from TFT any consequential or incidental damages for injury to person and/or property resulting from any defective equipment manufactured or assembled by TFT. It is agreed and understood that the price stated for the equipment is in part consideration for limiting TFT s liability. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above may not apply to you. TFT shall have no obligation under this limited warranty if the equipment is, or has been, misused or neglected (including failure to provide reasonable maintenance) or if there have been accidents to the equipment or if it has been repaired or altered by someone else. THIS IS A LIMITED EXPRESS WARRANTY ONLY. TFT EXPRESSLY DISCLAIMS WITH RESPECT TO THE EQUIPMENT ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. THERE IS NO WARRANTY OF ANY NATURE MADE BY TFT BEYOND THAT STATED IN THIS DOCUMENT. This limited warranty gives you specifi c legal rights, and you may also have other rights which vary from state to state. TASK FORCE TIPS, INC. MADE IN USA www.tft.com 370 Innovation Way, Valparaiso, IN 6383-9327 USA 800-38-2686 29-62-66 Fax 29-6-7