High-Throughput. Faster, Better 96 & 384-Well Pipetting Ultra Efficient and Extremely Versatile

Similar documents
VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

Good Pipetting Practice

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

Pipette Tips. Purity and Performance Rainin BioClean Ultra Tips Deliver

Transferpette. Lightweight precise rugged reliable!

Transferpette. Lightweight precise rugged reliable!

Improving Pipetting Techniques

Liquidator 96 Manual benchtop pipetting system

Operating Instructions. Rainin Classic Manual Pipette

Improve pipetting results in pharmaceutical formulation by using MICROMAN E

Air Displacement Pipetting Modules. Total Integrated Liquid Handling

Chapter 2. Pipetting techniques. Guide to Pipetting

Adjust the Volume Display

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay

RayPette Plus Autoclavable Pipette. User Manual

WHEATON. Peristaltic Pumps. Advancing the Science of Liquid Handling

The pipettes cover a volume range from 0.1µl to 10ml.

Operating Instructions. Liquidator 96 Manual benchtop pipetting system

Performance Verification of BioTek s Precision 2000 using Artel s Multichannel Volume Verification (MVV ) System

A Flexible, Multi-Purpose, Multi-Detector HTS Automated Platform

25/04/56. LTC Carmen A. Bell Chief, Laboratory Operations USAMC-AFRIMS

Air Displacement Pipetting Module. Total Integrated Liquid Handling

2017 PRODUCT GUIDE LIQUID HANDLING EXTRACTION PURIFICATION AUTOMATED SOLUTIONS SERVICES

MSD 96-Well MULTI-ARRAY CRP Assay

MOLEBIO LAB #1: Microquantity Measurement

Pipetting Small Volumes

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

A N F G J I C D D L A B C D E F

Register your instrument! Eppendorf Research plus. User Adjustment

Improve Process Reliability

Pipettor. User Manual

biosensis Human Lipocalin-2/NGAL ELISA Kit Protocol

JetVent SAFE, AUTOMATIC PRESSURIZED CONTAINMENT.

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

Register your instrument! Eppendorf Xplorer / Eppendorf Xplorer plus. Adjustment

Qi Litre Ultrasonic Cleaner

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Eliminating Sources of Pipetting Error in the Forensic Laboratory David M. Epstein Director of Scientific Operations. Abstract.

biosensis Rat Fibronectin ELISA Kit Protocol

biosensis Human TNFα/Cachectin/TNFSF2 ELISA Kit Protocol

Convergent Technologys product overview

biosensis Mouse Vascular endothelial growth factor A/VEGF-A/VEGF-164/VEGF-1/VEGF- 120/VEGF-2 ELISA Kit Protocol

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

Proline Plus Mechanical Pipette

biosensis Mouse Brain-derived neurotrophic factor (BDNF) ELISA Kit Protocol

biosensis Mouse CXCL10/IP-10 ELISA Kit Protocol

Transferpette. Single and Multichannel Pipettes

biosensis Rat Interleukin-1 beta, IL-1β ELISA Kit Protocol

biosensis Human IGF-II, Insulin-like growth factor II, Somatomedin-A ELISA Kit Protocol

biosensis Mouse Interleukin-1 beta (IL-1β) ELISA Kit Protocol

Pipetting and Determining Protein Concentration

MSD 96-Well MULTI-ARRAY Human (6E10) Abeta 42 Ultra-Sensitive Kit

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

MSD 96-Well MULTI-ARRAY Human (6E10) Abeta 40 Ultra-Sensitive Kit

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

Gilson Liquid Handling. Catalogue

Thermo Scientific Chromatography Well Plates

Thermo Scientific Chromatography Well Plates

Setting a New Standard in Flash Chromatography Performance

Imagine... full flexibility linked to high capacity. Tissue-Tek Prisma & Film. Automated Slide Stainer & Coverslipper

AN EXCITING NEW CONCEPT MICROBIOLOGY SLIDE STAINER/ CYTOCENTRIFUGE BIOMEDICAL PRODUCTS WESCOR, INC

INTRODUCTION TO THE SPECTROPHOTOMETER AND PIPETTING SKILLS

SOP-111 Pipetting Small Volumes

biosensis Rat Glial cell line-derived neurotrophic factor/gdnf total /ATF ELISA Kit Protocol

MULTICHANNEL. Labnet International, Inc.

PIPETMAN F ENGLISH. Other languages available on our website:

HumiSys HF High Flow RH Generator

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT

Quantos Automated Dosing Solution Preparation Precise concentrations Process compliance Minimize out-of-specs

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Imagine... full flexibility linked to high capacity

biosensis Human Soluble Tumor Necrosis Factor receptor type II (stnfrii) ELISA Kit Protocol

Protec P3000 (XL) Helium Sniffer Leak Detector

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Eppendorf Research fix variable multi Instruction Manual Bedienungsanleitung Mode d emploi Instruzioni d impiego Manual de Instrucciones

HOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.

ali-q TM Gravimetric Verification Procedure

Bioscience Laboratory Ergonomic Check List

EASYTOUCH. Because automation makes it all so simple. pentairpool.com

E-Man Hybrid. Manual pipette with real-time display. Continuously- Adjustable Microliter Pipette with LCD. volume ranges from 0.

Gel Loading Practice MiniLab

Thermo Fisher Scientifi c Automated Storage Solutions

Operating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx

The All New DIAMOND & DIAMOND BT

PIPET TIPS. UniFit ZFR (Zero Fluid Retention) Tips Universal Fitting Pipet Tips

A N B P F G J I C D D L A B C D E F

biosensis Rat IGF-1/Somatomedin/Insulin-like growth factor ELISA Kit Protocol

ACID FAST BACTERIA MICROBIOLOGY STAINER / CYTOCENTRIFUGE WESCOR, INC

Standard Operating Procedure. Air Displacement Pipette Calibration

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

MVS Volume Verification Using Any Microtiter Plate or Small Volume Container, Such as a Tube or Vial

SOP for use of the SX19 Stopped-Flow Instrument

ACT Prep - Experiments Round 1!

Tensiometer For the measurement of surface and interfacial tension

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

Organic Elemental Analysis Series II Nitrogen Analyzer. proven performance. reliable results

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

Transcription:

High-Throughput Rainin BenchSmart 96 Automated Aspiration/Dispense Multi-dispense Interchangeable Heads Four Trays, Small Footprint Outstanding Speed & Versatility Faster, Better 96 & 384-Well Pipetting Ultra Efficient and Extremely Versatile

High-Throughput BenchSmart 96 High-Throughput Pipetting... Simplified The Rainin BenchSmart 96 is designed for researchers who want the precision and reproducibility of automated liquid handling, yet need the speed and flexibility of a manual system. For complex protocols and precise liquid handling, nothing beats an automated pipetting system for accurate and consistent aspiration and dispensing. With its large touchscreen key pad, the Rainin BenchSmart 96 makes it easy to design, save and retrieve any protocol from simple one-step procedures to complex, multi-step experiments. What s more, the BenchSmart 96 improves repeatability by virtually eliminating variability in how liquids are aspirated and dispensed. There s an art to pipetting, which is why the BenchSmart 96 also gives users complete control over the instrument s mechanical movement. Whether it is the speed of movement, the exact position of the tips within a plate or reservoir, or a quick change in the order of a protocol, the BenchSmart 96 quickly adapts to almost any application. And with four tray stands to work with, you save time and reduce your risk of errors by minimizing the need to swap out trays and reservoirs. 2 Smart high-throughput With its large touchscreen key pad, Rainin s BenchSmart 96 makes it easy to design, save and retrieve any protocol, from simple one-step procedures to complex, multi-step experiments. Three pipetting heads Get the precision you demand with the 0.5-20 μl head, the lab workhorse you need with the 5-200 μl head, and the ready for sample preparation / cleanup 100-1000 μl head.

Save time and costs BenchSmart 96 simplifies and speeds workflows by significantly reducing, if not eliminating, the need to swap out tips and reservoirs. Proven tip technology Rainin guarantees that BenchSmart 96 LTS tips are free from RNase, DNase, DNA, ATP, and Pyrogens for contamination-free pipetting. Filter and pre-sterilized tips include certificates. 3

4 High-Throughput Loaded with Features Designed for Research At last a smart approach to high-throughput pipetting BenchSmart is designed for the research environment, where experimental conditions can quickly change and frequent modifications to the protocol are required. Its large color touchscreen and graphical interface make modifying even complex protocols a snap. And with the ability to manually move the liquid end over the four tray stands in x, y and z axes, it s easy to see why BenchSmart excels in undefined, exploratory research protocols. With built-in pipetting modes like advanced pipetting and multi-dispense, repetitive and oftentimes complicated components of liquid handling workflows are easily handled with exceptional consistency. For exploratory liquid handling work, BenchSmart s basic, dilute and reverse pipetting modes offer convenience and flexibility. Basic pipetting Transfer individual liquid samples quickly, reproducibly and with minimal effort everything you need for routine, everyday pipetting. Advanced pipetting Take greater control of your workflow by making fine adjustments and advanced features like setting a fixed volume, volume sequencing and mixing. Multi-dispense Dispense multiple aliquots from a single aspirated volume -- set a series of fixed volume aliquots or sequence of different volumes. Dilute Simplify in-tip dilution of multiple sample volumes with BenchSmart s fixed or volume sequencing feature

4-tray BenchSmart 96 (4 steps) 2-tray system (9 steps) 4 Reservoir B Reservoir B Tips 2 Tips Reservoir A 96- or 384- well Tray Reservoir A 96- or 384- well Tray Tips 3 1 Four tray for fewer steps, faster throughput Constantly swapping trays, even for a single-solution protocol, increases your potential for error and poses greater ergonomic risk. i Reverse pipetting Automates a procedure commonly used with viscous liquids positioning the piston past the first stop, aspirating, then depressing only to the first stop to dispense the aliquot. Head change Changing the pipetting head is quick and easy with BenchSmart on screen graphical instructions guide users through the simple procedure. Auto load/eject BenchSmart eliminates forces associated with tip loading and ejecting, plus assures a perfect fit on every channel every time. Context Sensitive Help Clear, easy to understand instructions for any screen you are on are available by touching the Help button. 5

High-Throughput Superior Performance The Flexibility to Meet Most Any Challenge The ideal pipetting station is one that easily adapts to modifications you make to your experiments and supports your need for accurate and reproducible data. As a researcher, your liquid handling needs are distinct and change often that s why BenchSmart 96 balances the precision of its automated features with the ability to quickly make adjustments to your experiment. With three interchangeable heads, BenchSmart 96 can help you increase your throughput on a variety of applications. For example: Perform qpcr and enzymatic reactions with the 0.5-20 µl head Process and wash ELISA plates using the 5-200 µl head Set up bacterial cell cultures in 96-well plates with the 100-1000 µl head With three pipetting heads and the Advanced, Reverse and Multi-dispense pipetting modes, BenchSmart can simplify and accelerate your most challenging and repetitious liquid handling workflows. Interchangeable Heads Quickly swap between three different heads to accommodate experimental workflows and pipetting applications. Onboard instructions In Head Change mode, BenchSmart guides users through each step of the head change process with animated graphics. Full volume range With three pipetting heads, BenchSmart accommodates pipetting from 0.5 to 1000 µl. 6

Your versatile new lab assistant Loaded with features and three liquid head volumes, BenchSmart quickly adapts to most any protocol. Technique 0.5-20 µl 5-200 µl 100-1000 µl PCR qpcr DNA Sequencing RNA Transcription ELISA Protein Crystollography Luminex Assays Drug Compound Screening Sequencing Sample Preparation Sequencing Sample Cleanup Standard Enzymatic Assays Cell Culture Set-up Cell Culture sirna Treatment Cell Lysis Rainin, LTS, LiteTouch and Pipetting 360 are registered trademarks, and BenchSmart is a trademark of Mettler-Toledo Rainin LLC. 7

www.mt.com/rainin For more information Mettler-Toledo Rainin, LLC 7500 Edgewater Drive, Oakland, CA 94621 Phone +1 510 564 1600 Fax +1 510 564 1604 Subject to technical changes 03/2016 Mettler-Toledo Rainin, LLC Printed on demand from online content. PB-265 Rev A