Transfero TI. Pressure maintenence systems with pumps Pressure maintenance systems up to 40 MW with pumps

Similar documents
Transfero T_. Pressure maintenance system with pumps For systems up to 10 MW

Pressure maintenance systems up to 10 MW with pumps

Pressure maintenance systems with compressors

Pressure maintenance systems with compressors

Compresso Connect F. Pressure maintenance systems with compressors For heating systems up to 4 MW and cooling systems up to 6 MW

Transfero TVI Connect

Aquapresso. Pressure stabilisation for potable water Pressure stabilisation for potable water

Compresso Connect. Pressure maintenance systems with compressors For heating systems up to 12 MW and cooling systems up to 18 MW

Accessories. Accessories for pressure maintenance

Pressure maintenance system with pumps and integrated vacuum degassing

STAP. Differential pressure controllers DN , ANSI flanges

STAD. Balancing valves DN 15-50

Compresso Connect F INSTALL

STAP. Differential pressure controllers DN , ANSI fl anges

Compresso Connect C10.1 / C15.1 / C10.2 / C15.2 INSTALL

Flamco Flexcon M-P Pump automat

KTM 50 (DN ) Installation, maintenance and operating instructions

Vento VI Connect VI 19/25 INSTALL

SonoMeter 30 Energy Meters

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

SonoSelect 10 and SonoSafe 10 energy meters

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

STA. Double regulating valves DN 15-50

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

STAD. Balancing valves DN (MD60, MD61, MD62)

TA-FUSION-P. NPT threads / ANSI flanges

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

Pressure Calibrators. Series PC..., PM...

STAP. Differential pressure controller DN

Pressurisation Systems. Variomat. Pump Controlled Pressurisation Systems. Pressure maintenance Deaeration Water make-up. For Control Touch:

Monitoring device NTS 30

EnerVal. Technical data litre storage capacity. Buffer storage vessels

LIKE ME. Expert, highly efficient and customer-orientated

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Floor heating. Floor heating manifolds Distributors

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

High-performance submersible pressure transmitter For level measurement Model LH-20

STA. Double regulating valves DN 15-50

EPP4 Pressure Regulator Basic G 1/4"

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

High-performance submersible pressure transmitter For level measurement Model LH-20

[Instruments for vacuum measurement, checking and adjustment] 3

Old documentation - Only for your information! Product is not available anymore!

TRV-2, TRV-2S. Thermostatic radiator valves With presetting

STAD-C. Balancing valves DN 15-50

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

SITRANS P measuring instruments for pressure

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

High-performance submersible pressure transmitter For level measurement Model LH-20

2-port seat valves PN25 with externally threaded connections

KMT. Thermal Mass Flowmeter. for compressed air and gases. Measuring range: Nm³/h Nm³/h

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

STAG. Balancing valves Balancing valve with grooved ends DN

Pressure Measurement Single-range transmitters for general applications

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

Gas Pressure Regulator HON 300

Pneumatic high-pressure controller Model CPC7000

Digital electro-pneumatic regulators Series ER100

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control

Wet pipe low flow foam/water system

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Technical Manual. Liquid Level Transmitter CT801-LB/S

System Pressure Manager Standard & System Pressure Manager Plus

Pressure Automated Calibration Equipment

Expert Hydrostatic Level Transmitters

PNEUMATEX. Product overview as per International edition Products Applications Benefits PNEUMATEX

BUBBLER CONTROL SYSTEM

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Flamco Flexcon M-K Compressor - automat expansion vessel

BUBBLER CONTROL SYSTEM

Workhorse-15 Oxygen Generator

Level transmitter LT 100

2-port and 3-port seat valves, PN16

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Additel 780 Series Pressure Controller

2/ Port G1/4

Automatic balancing valves ASV

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)

Two-port valves, male threaded, PN25

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Controller for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW User guide

PressVal Pressurisation Units. Packaged Pressurisation Units with expansion vessels for heating systems.

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

Pneumatic high-pressure controller Model CPC7000

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Visualize Nitrogen Gas Consumption

Deep Submersible Level Transducer Series 300DS

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Transcription:

Transfero TI Pressure maintenence systems with pumps Pressure maintenance systems up to 40 MW with pumps

IMI PNEUMATEX / Pressurisation / Transfero TI Transfero TI Transfero TI is a precision pressure maintenance device up to 40 MW with pumps for heating, solar and chilled water systems. Its use is particularly recommended where high performance, compact design and precision are required. Key features > > raincube control Self-optimising with memory function. > > 2 pumps 2 spill connections each with 2 in series connected spill valves. Switching is time and load dependent. > > PowerCube panel PC1 Mains isolator with emergency off; 2 motor protection switches; soft start and soft stop automatic for each pump. > > Fillsafe water make-up monitoring with possibility to control water makeup through a Pleno P. Technical description Control unit Tecox Applications: eating, solar and chilled water systems. For systems to EN 12828 and optional >110 C to EN 12952, EN 12953 with additional pressure limiters Paz PMIN and content indicators Liz IA, solar systems according to EN 12976, ENV 12977 with on-site excess temperature protection in case of power blackout. Media: Non-aggressive and non-toxic system media. Addition of antifreeze agent up to 50%. Pressure: Min. admissible pressure, PSmin: 0 bar Max. admissible pressure, PS: see Articles Temperature: Max. admissible temperature, TS: 90 C Min. admissible temperature, TSmin: 0 C Max. admissible ambient temperature, TU: 40 C Min. admissible ambient temperature, TUmin: 5 C Accuracy: Precision pressure maintenance ±0,2 bar. Supply voltage: Main current: 3x 400V / 50z (3P + PE) Control voltage: 230V / 50z (P + N + PE) Enclosure class: IP 54 Material: In essence: steel, brass and bronze Connections: Water make-up (SNS): Rp3/4 Connection vessel (SG): 80/6 DN/PN Approvals: CE-tested according to the requirements of the European Directives PED/DEP 97/23/EC, 2004/108/EC, 2006/95/EC. 2

Technical description Expansion vessels Applications: Only together with Control unit Tecox. See Applications under Technical description - Control unit Tecox. Transfero TGI: Water level limiter only in combination with Liz IA content indicator with Transfero TI to EN 12952 and EN 12953. Media: Non-aggressive and non-toxic system media. Addition of antifreeze agent up to 50%. Pressure: Min. admissible pressure, PSmin: 0 bar Max. admissible pressure, PS: 2 bar Temperature: Max. admissible temperature, TS: 120 C Min. admissible temperature, TSmin: -10 C Max. admissible bag temperature, T: 70 C Min. admissible bag temperature, Tmin: 5 C Material: Steel, welded. Color beryllium. Approvals: CE design-tested according to PED/DEP 97/23/EC. Warranty: 5-year warranty for the vessel. 5-year warranty for the airproof butyl bag. Function, Equipment, Features Tecox - 2 pumps. 2 spill connections each with 2 in series connected spill valves. Switching is time and load dependent. - Fillsafe water make-up monitoring. With possibility to control water make-up through a Pleno P. - raincube control. Self-optimising with memory function. - Protected isolating valves for safe isolation. - PowerCube panel PC1. Mains isolator with emergency off; 2 motor protection switches; soft start and soft stop automatic for each pump. - igh quality, solid, galvanized base. - Variable installation in front of or next to the primary vessel. - Inclusive of DSV...DG safety valves for vessel protection. Expansion vessels - Airproof butyl bag according to EN 13831, exchangeable. - ag can be vented at the top, condensate drain at the bottom. - Feet for upright assembly. - Including flexible hose for the water-side connection and lock shield valve with ball valve for fast draining. - Two flange openings for internal inspections. 3

IMI PNEUMATEX / Pressurisation / Transfero TI Control unit Tecox Transfero TI Connection vessel (SG): DN 80 / PN 6 Connection water make-up (SNS): Rp 3/4 S 1100 x 1100 SG Type* PS [bar] m S [DN/ PN] Pel [kw] SPL [d(a)] TI 90.2 PC1 16 1200 135 50/40 3,0 <70 7640148639767 811 1400 TI 120.2 PC1 16 1200 145 50/40 3,8 <70 7640148639774 811 1405 TI 150.2 PC1 16 1200 170 50/40 5,4 <70 7640148639781 811 1410 TI 190.2 PC1 25 1200 195 50/40 5,4 <70 7640148639798 811 1415 TI 230.2 PC1 25 1300 215 50/40 7,2 <70 7640148639804 811 1420 TI 61.2 PC1 10 1200 135 80/16 3,0 <70 7640148639811 811 1425 TI 91.2 PC1 10 1200 150 80/16 4,2 <70 7640148639828 811 1430 TI 111.2 PC1 16 1200 175 80/16 5,4 <70 7640148639835 811 1435 TI 161.2 PC1 16 1300 190 80/16 7,2 <70 7640153588425 811 1440 TI 191.2 PC1 25 1400 210 80/40 9,4 <70 7640153588432 811 1445 TI 231.2 PC1 25 1600 250 80/40 12,4 <70 7640153588449 811 1450 TI 62.2 PC1 10 1200 185 80/16 5,4 <70 7640153588456 811 1455 TI 102.2 PC1 16 1200 205 80/16 7,2 <70 7640153588463 811 1460 TI 132.2 PC1 16 1200 215 80/16 9,4 <70 7640153588470 811 1465 TI 182.2 PC1 25 1400 280 80/40 12,4 <70 7640153588487 811 1470 TI 212.2 PC1 25 1500 305 80/40 16,8 71 7640153588494 811 1475 *) Constructions TI..3.2 and special installations upon request. Accessories for control modules: Communication module. Additional equipment: Pressure limiter Paz PMIN and content indicator Liz IA. Master-Slave. Expansion vessels Transfero TGI Primary vessel. Measuring foot for content measurement. Type* D ** m S SW 2 bar (PS) TGI 1000 1000 850 2191 280 G1 1/2 G3/4 7640148631983 713 3100 TGI 1500 1500 1016 2340 360 G1 1/2 G3/4 7640148631990 713 3101 TGI 2000 2000 1016 2839 640 G1 1/2 G3/4 7640148632003 713 3106 TGI 3000 3000 1300 2940 800 G1 1/2 G3/4 7640148632010 713 3103 TGI 4000 4000 1300 3585 910 G1 1/2 G3/4 7640148632027 713 3104 TGI 5000 5000 1300 4230 1010 G1 1/2 G3/4 7640148632034 713 3105 = Nominal volume 4

Transfero TGI...E Secondary vessel. Type* D ** m S SW 2 bar (PS) TGI 1000E 1000 850 2191 280 G1 1/2 G3/4 7640148632041 713 3300 TGI 1500E 1500 1016 2340 360 G1 1/2 G3/4 7640148632058 713 3301 TGI 2000E 2000 1016 2839 640 G1 1/2 G3/4 7640148632065 713 3306 TGI 3000E 3000 1300 2940 800 G1 1/2 G3/4 7640148632072 713 3303 TGI 4000E 4000 1300 3585 910 G1 1/2 G3/4 7640148632089 713 3304 TGI 5000E 5000 1300 4230 1010 G1 1/2 G3/4 7640148632096 713 3305 = Nominal volume Transfero TGI... Primary vessel. 1 measuring foot for content measurement, 1 measuring foot for water level limiter. Type* D ** m S SW 2 bar (PS) TGI 1000 1000 850 2191 285 G1 1/2 G3/4 7640148632102 713 3200 TGI 1500 1500 1016 2340 365 G1 1/2 G3/4 7640148632119 713 3201 TGI 2000 2000 1016 2839 645 G1 1/2 G3/4 7640148632126 713 3206 TGI 3000 3000 1300 2940 805 G1 1/2 G3/4 7640148632133 713 3203 TGI 4000 4000 1300 3585 915 G1 1/2 G3/4 7640148632140 713 3204 TGI 5000 5000 1300 4230 1015 G1 1/2 G3/4 7640148632157 713 3205 = Nominal volume *) Special vessel upon request. **) Tolerance 0 /-100. Additional equipment: Pressure limiter Paz PMIN and content indicator Liz IA. 5

IMI PNEUMATEX / Pressurisation / Transfero TI Accessories for control modules Communication module. Factory fitted to Transfero TI. Max. admissible ambient temperature, TU: 40 C Enclosure class: IP 54 Supply voltage: 230 V/50 z ComCube DCD TI RS 485 interface for communicating with raincube, 6 digital inputs for the use of external volt free signals (NO), 9 volt free digital outputs, freely programmable; all outputs can be inversed. Complete connections of all in and outputs with connectors of the PowerCube panel. Type T m Pel [kw] DCD TI 270 230 180 0,5 0,1 7640148638722 814 1005 ComCube DCA TI 2 separated analoge outputs 4-20 ma for connection to MS, isolation voltage 2.5 kvac. Connected via mounting rail in the PowerCube panel. Type T m Pel [kw] DCA TI 17,5 120 146 0,2 0,1 7640148638746 814 1015 Software expansion Usage options as Master / Slave, parallel, expanded capacity or 100% redundancy. Remote switching of Master / Slave possible. Cabeling on site, commissioning by IMI Pneumatex Service. Master-Slave DMS 2 Parallel operation of 2 Transfero TI. Including assembly kit with 1 safety valve for protection of the maximum pressure at Transfero TU, TU...E and TG, TG...E expansion vessels. Type DMS 2 T 7640148638760 814 1021 Master-Slave DMS 3 Parallel operation of 3 Transfero TI. Including assembly kit with 2 safety valves for protection of the maximum pressure at Transfero TU, TU...E and TG, TG...E expansion vessels. Type DMS 3 T 7640148638784 814 1026 6

Master-Slave DMS 4 Parallel operation of 4 Transfero TI. Including assembly kit with 3 safety valves for protection of the maximum pressure at Transfero TU, TU...E and TG, TG...E expansion vessels. Type DMS 4 T 7640148638807 814 1031 Additional equipment Liz/Paz: Additional equipment for systems >110 C according to EN 12952, EN 12953. Max. admissible ambient temperature, TU: 40 C Supply voltage: 230 V/50 z Paz: Max. admissible temperature, TS: 70 C Min. admissible temperature, TSmin: 0 C Min. admissible pressure, PSmin: 0 bar Enclosure class: IP 54 Liz IA K4 Water level controller. Mounting on the Transfero TGI... vessel. With signal lamps and 4 floating contacts to indicate content is minimal or maximal, water make-up start and water make-up stop. Complete in a casing for mounting on the TGI... vessel. TÜV-tested type approval label WP05-347. Type T m Pel [kw] IA K4/1000.08 1000 180 260 200 3,5 0,1 7640148638654 824 1850 IA K4/1500.08 1500 180 260 200 3,5 0,1 7640148638661 824 1851 IA K4/2000.08 2000 180 260 200 3,5 0,1 7640148638678 824 1852 IA K4/3000.08 3000 180 260 200 3,5 0,1 7640148638685 824 1853 IA K4/4000.08 4000 180 260 200 3,5 0,1 7640148638692 824 1854 IA K4/5000.08 5000 180 260 200 3,5 0,1 7640148638708 824 1855 Paz PMIN Minimum pressure switch. For retrofitting to Transfero TI. Fitting on site into Tecox and connection to control module. TÜV-tested in accordance with VdTÜV Druck 100/1 for specialised equipment and according to PED/ DEP 97/23/EC. Paz PMIN 0-6 Paz PMIN 6-16 Paz PMIN 0-25 Type T m S dpu [bar] PMIN 0-6 16 82 180 40 0,5 G1/2 0-6 7640148638821 825 1521 PMIN 6-16 30 82 194 30 0,5 G1/2 6-16 7640148638845 825 1523 PMIN 0-25 30 133 208 61 0,5 G1/2 0-25 7640148638869 825 1525 7

IMI PNEUMATEX / Pressurisation / Transfero TI Paz PMIN TI Minimum pressure switch. Factory fitted to Transfero TI. Pre connected to control module. TÜV-tested in accordance with VdTÜV Druck 100/1 for specialised equipment and according to PED/ DEP 97/23/EC. Paz PMIN 0-6 Paz PMIN 6-16 Paz PMIN 0-25 Type T m S dpu [bar] PMIN 0-6 TI 16 82 180 40 0,5 G1/2 0-6 7640148638814 825 1520 PMIN 6-16 TI 30 82 194 30 0,5 G1/2 6-16 7640148638838 825 1522 PMIN 0-25 TI 30 133 208 61 0,5 G1/2 0-25 7640148638852 825 1524 Additional information: System design: Datasheet Planning and calculation. Calculation: Software yselect Abbrevations and terminology: Datasheet Planning and calculation. The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by IMI ydronic Engineering without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit www.imi-hydronic.com. RST EN Transfero TI 09.2014