Sorbent Pens. For Next Generation Headspace Analysis

Similar documents
Sorbent Pen Heavy & Labile SVOC s Taints, Off-Flavors, Odors

Vapor Intrusion. Sampling Solutions VAPOR INTRUSION. Sampling Solutions

ANALYSIS OF MALT WHISKEY

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

GCMSD-Headspace Analysis SOP

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

Demystifying the Process of Calibrating your Thermal Desorption Gas Chromatography System using Compressed Gas Standards.

Considerations and Best Practices for Maintaining Your Agilent GC s Split/Splitless Injection Port

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

Rapid and Reliable Detection of Dissolved Gases in Water

Ghost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

Experiment GC : Analysis of BTEX by GC-FID

Air Quality 2b - PFGC/FID Analysis of Benzene and Toluene in Automobile Emissions

CHEMTRACE Fremont Blvd. Fremont, CA 94538, Tel: (510) Fax: (510)

Automated Low Background Solid Phase Extraction of Perfluorinated Compounds in Water. Ruud Addink Fluid Management Systems Watertown MA

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

STANDARD OPERATING PROCEDURES

CORESTA RECOMMENDED METHOD Nº 67

APPLICATION NOTE. GC Integrated Permeation Device

Major Design Features

Automated Determination of Dissolved Gases in Water By Headspace Calibration of Mixed Gases Anne Jurek

Automated Determination of Dissolved Gases in Water Anne Jurek

Retention Time Locking: Concepts and Applications. Application

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

M-CTE250(T)(i) TM. Micro-Chamber/Thermal Extractor Operator Manual. Version February 2012

The instrument will process the samples one by one till all the samples have been cleaned up.

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Advancements in Gas Chromatography Analyzers - Keeping up with New Technology. Chuck Runkle Gas Phase Product Specialist ASTS June 2013

Thermo Scientific Chromatography Well Plates

Thermo Scientific Chromatography Well Plates

ASTM WK Standard Test Method for Dissolved Gases. Anne Jurek Applications Chemist

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Markes Thermal Desorption Systems Site Preparation Page 1 of 8

Comparative analysis of mass spectral matching for confident compound identification using the Advanced Electron Ionization source for GC-MS

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

no peaks missing peaks too small peaks increasing retention decreasing retention

Carrier Gases in Capillary GC

May 1, By John Heim,Doug Staples

FROG-4000 TM Chemical Analysis System

Office VOC Mixture Test Report

6890 GC Site Preparation

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

FROG-4000 TM Chemical Analysis System

Products Designed to Solve Nagging GC Problems

extraction of EG and DEG from the matrix. However, the addition of all diluent at once resulted in poor recoveries.

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Super-Clean Gas Filters from Restek

Organic Elemental Analysis Series II CHNS/O Elemental Analyzer. proven performance. reliable results

Simultaneous Determination of a Panel of 22 Steroids in Urine and Serum by SPE and LC-MS/MS

Chromatography Consumables

Increasing the productivity of ICP-OES with the Thermo Scientific Qtegra ISDS Software

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Zebron Gas Management

Residual Gas Analysis Systems for Industry

Best Practice for Identifying Leaks in GC and GC/MS Systems

3. Coupled Techniques in Thermal Analysis

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 7820MSD Series G3175A (G7020A), G3176A (G7021A)

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

Setting a New Standard in Flash Chromatography Performance

Using the Agilent 6890N GC/MS for Sampling Volatile Organic Compounds. Bob Castro, B.S. Chemical Eng., M.S. Environmental Eng.

Impact of Air Leaks on the Productivity of GC and GC/MS Systems

Organic Elemental Analysis Series II Nitrogen Analyzer. proven performance. reliable results

Extend the time window for the detection of low level anabolic androgenic steroids and their metabolites

Mass Spec will not Autotune

MV5: Automated concentration system

Introduction. Experimental

Basic & Controlled Atmosphere Glove Boxes

NCASI METHOD IM/CAN/WP IMPINGER/CANISTER SOURCE SAMPLING METHOD FOR SELECTED HAPS AND OTHER COMPOUNDS AT WOOD PRODUCTS FACILITIES

Gas Standards. Single Component Gas Standards. general chromatography. standards and reagents.

Converting Helium Carrier Gas GC Methods Nitrogen and Hydrogen

The Tekran Series 2600-IVS Difference!

Jaap de Zeeuw Restek Corporation, Middelburg, The Netherlands. Copyrights: Restek Corporation

A SCENT OF FUTURE. Master DHS. Dynamic Head Space Sampler. Operating Manual

SUPPORTING INFORMATION

Instruction Bulletin Addendum For Pressure-Balanced In Situ Oxygen Probes

The instrument should have a mass range from 2 to 2000 m/z or better Interface

Recent Advances to Ensure Simple, Leak Free GC Column Connections. Ken Lynam R&D/Application Chemist Agilent Consumables and Supplies Division

E SC 412 Nanotechnology: Materials, Infrastructure, and Safety Wook Jun Nam The Pennsylvania State University

Quick Reference Guide. OPTIC 3 - PTV on Shimadzu GC-2010 Gas Chromatograph

Agilent 7697A Headspace Sampler

Improving the Measurement Accuracy of Water Partial Pressure Using the Major Constituent Analyzer

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Multiple Gas#5 GC configuration Jan 2016

3 Flow and Pressure Control

TD-100 TM. Operator Manual. Version 1.1. August QUI-1069 TD-100 Operators Manual

Carrier Gases in Capillary GC

SIS AutoDesorb Operation Manual

Technical Information

STANDARD OPERATING PROCEDURES

FAST EVAPORATION AT NORMAL PRESSURE

SOLVENT PURIFICATION SYSTEMS

Instant Connect Helium Saver Injector Module

Practical approach and problems in in-situ RGA calibration

Transcription:

Sorbent Pens For Next Generation Headspace Analysis

Headspace Sorbent Pens - The Ultimate Extraction Power Introducing Entech s exciting new Sorbent Pen technology. The most versatile extraction and sample preconcentration technology available for GC and GCMS. Sorbent Pens combine the features of SPME and classical ¼ adsorbent traps in a design with far more flexibility and enhanced performance. Sorbent Pens are extremely durable and are designed to perform both active and diffusive sampling. The Sorbent Pen is then desorbed directly onto the head of a GC column to eliminate losses associated with standard thermal desorption systems that must transport the desorbed sample through rotary valves, secondary traps, and a lengthy transfer line prior to delivery onto the GC column. The Sorbent Pen uses an entirely new approach for sample extraction. Direct insertion of the Sorbent Pen into the vial headspace followed by evacuation of the vial through the top of the Pen allows a new technique called "Vacuum Assisted Sorbent Extraction", or VASE, to recover a far wider range of compounds than ever before. With Sorbent Pens, both VOCs and SVOCs can be measured in wastewater, breath condensate, alcoholic beverages, and virtually all other matrices. VASE offers a tremendous advantage over other extraction techniques that perform extractions at atmospheric pressure where diffusion rates are suppressed. Sorbent Pens perform sample enrichment offline from a GCMS, allowing all samples to extract simultaneously and for longer periods of time. This approach results in high throughput while yielding a more complete and reproducible extraction for more sensitive and quantitative measurements. The low cost 5800 Sorbent Pen Desorption Unit (5800 SPDU) makes this exciting new technique both affordable and practical for virtually any laboratory s budget. Then move up to 90 sample automation with the 7800 Autosampler for the ultimate in laboratory productivity. Join the Sorbent Pen movement and take advantage of the next generation in GCMS sample preparation. Improvements over SPME and Dynamic Headspace Trapping Applications include: Cannabis - Pesticide Screening Highly reproducible. - Terpene Profiling Very low carryover. - Potency Testing Durable - hundreds of injections. - CBD, THC Operates at or near equilibrium to improve sensitivity and quantitative accuracy. Perform exhaustive vacuum extraction of VOCs through SVOCs. Unlike SPME, outer sheath minimizes exposure to aerosols formed during agitation. See taints, odors, additives, flavors & fragrances at levels below previously possible. Faster injection rates produces better chromatography / less thermal degradation. Rapid injections without cryogen or electronic cooling. Usually requires no secondary bakeout/cleanup. Higher sensitivity and throughput via off-line extraction. Sample up to days under vacuum for unsurpassed SVOC recovery. Sample at elevated or sub-ambient temperatures as needed. Food Safety - Nitrosamines - Acrylimides - Pesticides/Herbicides - Carcinogens - Preservatives Flavors/Aromas - Foods - Beverages - Alcoholic Beverages Fragrances - Taints/Off-Flavors - Odors in Consumer Products - Residue Drugs/Pharma - PCBs, PBDEs Water Analysis - Odors - SVOCs - VOCs Clinical Markers/Drugs In - Blood - Urine - Breath For a complete list of applications, visit entechinst.com Headspace Sorbent Pens DESCRIPTION PART # UNIT Headspace Sorbent Pens Tenax TA (35/60) SP-HS-T3560 EA Tenax + Carboxen 000 SP-HS-TCBXN EA Empty Headspace Pen SP-HS-0 EA Headspace Pen Tray SP-HS-TRAY30 EA Durable, Reuseable, and Cost Effective!

VASE using Sorbent Pens Operates at or Near Equilibrium to Improve Sensitivity and Reproducibility Operating at or near equilibrium increases sensitivity and reduces run to run variability Small movements back and forth on curve for VASE as the samples approach equilibrium causes little change in recoveries, and therefore reproducibility. VASE - Vacuum Assisted Sorbent Extraction 00% Relative Difference -5% At Equilibrium VASE - 60-98% Recovery (Compound Dependent) Rate of Extraction Is Not As Important If Analysis Is Made After Equilibrium Is Achieved Pen Pen Fiber Fiber 3x x SPME - -0% Recovery Highly Variable Run to Run Requires Isotope Dilution for Quantitation Relative Difference 300% Due To Rate Differences During Extraction Time Equilibrium Reached VASE (Sorbent Pens ) vs SPME and SBSE (Twister ) Recovery Relative to Analyte Volatility Sorbent Pens using Vacuum Assisted Sorbent Extraction (VASE) recover compounds starting even lighter than SPME, and out to nearly those recovered by SBSE Most applications done by either SPME or SBSE can be done more easily and usually with higher sensitivity and accuracy with VASE using Sorbent Pens

Sorbent Pen Desorption Unit (SPDU) Sorbent Pens are analyzed using the 5800 SPDU. After sample enrichment, simply insert the Sorbent Pen into the 5800 SPDU, and press START on the 5800 SPDU Controller. The complete desorption process is performed automatically to transfer both volatile and semi-volatile compounds onto the GCMS for extremely sensitive and accurate headspace analysis. Control the desorption temperature to either limit or maximize the molecular weight range transferred onto the column. A unique desorber design utilizes a Silonite coated flow path, allowing simple liner replacement to maintain maximum inertness for optimum long-term performance. Methods are created and stored on the same PC operating the GCMS. Develop methods using this entry level solution and then add the 7800 Autosampler when you are ready to fully automate the analysis of up to 90 Sorbent Pens. 5800 SPDU Easily transfers volatile and semi-volatile compounds to a GCMS for extremely sensitive and accurate headspace analysis. 5800 SPDU Ordering Information DESCRIPTION PART # UNIT Sorbent Pen Desorption Unit (0VAC) 5800-SPDU EA Sorbent Pen Desorption Unit (30VAC) 5800-SPDU-HV EA 5800 SPDU Liner for Headspace Sorbent Pen 5800-LNR-HS EA GC Model Mounting Kits: Agilent 6890/7890(B) 5800-GC-AG EA Thermo 300/30 GC 5800-GC-TH EA Shimadzu 00 GC 5800-GC-SH EA 3

Sorbent Pen Autosampler The 7800 Autosampler automates the analysis of up to 90 Sorbent Pens using 3 removable 30 position trays. The ability to use Sorbent Pens to pre-extract the headspace in a sample vial, or perform air sampling in almost any location, followed by rapid delivery to a GCMS creates the ideal combination of sensitivity and efficiency. The 7800 delivers each Sorbent Pen to the 5800 SPDU for GCMS injection and bakeout. After bakeout, the 7800 returns the Sorbent Pen to the sealed sample tray leaving clean Pens that are usually ready for resampling without further conditioning. The Sorbent Pen's unique triple o-ring seal ensures leak tight connections, while the design of the 5800 provides rapid and reproducible transfer to the GC column to support quantitative headspace analysis. The combined power and simplicity of the Sorbent Pen and 7800 / 5800 SPDU provides an ideal solution for recovering a vastly extended range of compounds in the sample headspace, allowing development of hundreds of applications compatible with virtually any matrix. 7800 Sorbent Pen Autosampler Part# 7800-SPA Sorbent Pen Extraction System The Sorbent Pen Extraction System provides a convenient way to perform vial extractions using 30-position trays. Load the sample to be extracted into the vial, insert the Sorbent Pen, create a vacuum through the MicroQT seal at the top of the Pen, and then load the tray into the 5600 to start the vacuum extraction. The Sorbent Pen Extraction System agitates the samples at 30-300 RPM to speed up transfer of volatiles to the headspace, while heating the sample from ambient +4 C to 70 C. Extractions will be complete in 48 hours depending on the application. DESCRIPTION PART # UNIT 5600 Sorbent Pen Extraction System 5600-SPES EA 5600 Sorbent Pen Extraction System (30VAC) 5600-SPES-HV EA 30-Position Tray for 0/40/60 ml Vials 5600-040TRAY30 EA 30-Position Tray for 5mL Vials 5600-5TRAY30 EA 40mL Clear Vials 39-75040 7pk 0mL Clear Vials 39-7500 7pk Extraction Lid for 40mL Vial / 5mL Bottle SP-L04S EA Plastic Vial Caps (40mL/5mL) 39-76044B 44pk Dual Stage Diaphram Pump 0-0030 EA Dual Stage Diaphragm Pump (30VAC) 0-0034 EA Vial Evacuation Unit SP-VIAL-EVAC EA 4

3 Sorbent Pen Thermal Conditioner The 380 can be used to condition Sorbent Pens prior to use at temperatures up to 350 C. Use the 380 for new Pens, Pens that were not isolated after desorption, and Pens that contained unusually high concentrations where complete removal of the residual sample did not occur during the previous analysis. Flow rate of thermal conditioning gas is controlled and monitored through a convenient front panel flow controller, while an internal valve starts and stops the flow of UHP Nitrogen at appropriate Sorbent Pen conditioning temperatures. 380 Sorbent Pen Thermal Conditioner DESCRIPTION PART # UNIT Sorbent Pen Thermal Conditioner (0VAC) 380-SPTC EA Sorbent Pen Thermal Conditioner (40VAC) 380-SPTC-HV EA 5

Headspace Bundle Kit 5800 SPDU Injector Unit 5800 SPDU Controller Vial Evacuation Unit 5800 Liner for Headspace Sorbent Pens 30 Position Tray for Headspace Sorbent Pens Sorbent Pen L Extraction Vial Kit Fitting Cap Sorbent Pen Lid Lid Cap Sorbent Pen Thermal Conditioner Sorbent Pen Extraction System SP-HS-B0 Headspace Bundle Kt 40mL & 0mL Clear Vial 30 pos tray for 40mL vials L Clear Vial -Stage Oilless Diaphragm Pump DESCRIPTION PART # UNIT Sorbent Pen Desorption Unit 5800-SPDU EA 5800 Liner for Headspace Sorbent Pen 5800-LNR-HS EA Tenax HS Sorbent Pen SP-HS-T3560 EA Blank HS Sorbent Pen SP-HS-0 EA 30 Position Tray Headspace Sorbent Pens SP-HSTray30 EA -Stage Oilless Diaphragm Pump 0-0030 EA PDMS Pre-Column (5m x 0.5mm ID, 0.5um) 56-0550 EA Sorbent Pen Thermal Conditioner 380-SPTC EA 30-0 Hg Vacuum Test Gauge (W/ Micro-QT ) 9-7000QT EA DESCRIPTION PART # UNIT Sorbent Pen Extraction System 5600-SPES EA 30 Position Tray for 40mL Vials 5600-040TRAY30 EA 40mL Clear Vials 39-75040 7pk 0mL Clear Vials 39-7500 7pk Lid for 40/60mL Vials/5mL Bottles SP-L04S EA Low Bleed Blue Viton O-Rings SP-L04-OR 0pk Caps for 40/60mL Vials/5mL Bottles 39-76044B 44pk L Sorbent Pen Extraction Vial Kit with Lid/Cap/Fitting SP-HS-VL EA Vial Evacuation Unit SP-VIAL-EVAC EA 6

Brie Cheese Duplicate Analysis.e+07 e+07 9000000 8000000 7000000 6000000 5000000 4000000 SORBENT PEN # 8 3 3000000 000000 000000 0 3 4 5 6 7 9 0 3 4 5 6 7 8 0.00 5.00 0.00 5.00 30.00 35.00 9 *0 4.e+07 e+07 9000000 SORBENT PEN # 8 3 8000000 7000000 6000000 5000000 4000000 3000000 000000 000000 0 3 4 5 6 7 9 0 3 4 5 6 0.00 5.00 0.00 5.00 30.00 35.00 7 8 9 *0 4 *Difference in Dodecanoic acid, ethyl ester caused by difficulty in maintaining exact amount of cheese sample oxidation from run to run, and expected variations in sample homogeneity. Instrument: Run date: Sample description: Weight of sample (g): Sample conditions: Desorb conditions: Split Mode: Precolumn: Column: Carrier: Oven Temp: GCMS: MS Operation: 5800 HSP 5-Aug-6 Brie 70g cheese in 40mL water, blended, 0.05g taken blended + vac(30sec) + 50 C + 3 hr equilibration 60 C for 5 min. Splitless DB 5m length x 0.5mm ID, 0.5µm film DB 30m length x 0.5mm ID, 0.5µm film He,.5cc/min. constant flow 40 C hold 5min., 6 C/min. to 95 C, 0 C/min. to 40 C, 0 C/min. to 35 hold 5min. Agilent 7890B/5977A 34-450 amu,.8 scans/sec. 4-Heptanone. -Heptanone 3. Benzaldehyde 4. -Octanone 5. Hexanoic acid, ethyl ester 6. Benzeneacetaldehyde 7. 8-Nonen--one 8. -Nonanone 9. Nonanal 0. Octanoic acid. Octanoic acid, ethyl ester. Decanal 3. n-octanoic acid isopropyl ester 4. -Undecanone 5. n-decanoic acid 6. Decanoic acid, ethyl ester 7. H-Pyran--one, tetrahydro-6-pentyl- 8. -Tridecanone 9. Dodecanoic acid 0. Dodecanoic acid, ethyl ester. H-Pyran--one, 6-heptyltetrahydro-. Tetradecanoic acid 3. n-hexadecanoic acid 4. Hexadecanoic acid, ethyl ester 7

Extremely Clean Blank After Strawberry Analysis 9 3.5e+08 3e+08.5e+08 e+08.5e+08 e+08 5e+07 0 4 8 6 5 0 3 5 7 34 8 7 9 6 6.00 8.00 0.00.00 4.00 6.00 8.00 0.00.00 4.00 6.00 8.00 3.5e+08 3e+08 Blank run of the same Sorbent Pen directly after strawberry sample.5e+08 e+08 40.00.5e+08 e+08 5e+07 0 6.00 8.00 0.00.00 4.00 6.00 8.00 0.00.00 4.00 6.00 8.00 Instrument: Run date: Sample description: Weight of sample (g): Sample conditions: Desorb conditions: Split Mode: Precolumn: Column: Carrier: Oven Temp: GCMS: MS Operation: 5800 HSP 3-Aug-6 Fresh strawberries 7.745 vac(30sec) + 5hr equilibration 60 C for 5 min. Splitless DB 5m length x 0.5mm ID, 0.5µm film DB 30m length x 0.5mm ID, 0.5µm film He,.5cc/min. constant flow 40 C hold 5min., 6 C/min. to 95 C, 0 C/min. to 40 C, 5 C/min. to 35 hold 5min. Agilent 7890B/5977A 34-450 amu,.8 scans/sec 5000000. Ethyl acetate. Butanoic acid methyl ester 3. Propanoic acid, -methyl-, ethyl ester 4. Butanoic acid, ethyl ester 5. Acetic acid, butyl ester 6. Butanoic acid, -methyl-, ethyl ester 7. -Butanol, 3-methyl-, acetate 8. Hexanoic acid, methyl ester 9. Hexanoic acid, ethyl ester 0. -Hexen--ol, acetate, (Z)-. 3(H)-Furanone, 4-methoxy-,5-dimethyl-.,6-Octadien-3-ol, 3,7-dimethyl- 3. Octanoic acid, methyl ester 4. Methyl salicylate 5. Octanoic acid, ethyl ester 6. Butanoic acid, octyl ester 7. Pentanoic acid, octyl ester 8.,6,0-Dodecatrien-3-ol, 3,7,-trimethyl- 9..gamma.-Dodecalactone 4000000 3000000 000000 40.00 000000 0 6.00 8.00 0.00.00 4.00 6.00 8.00 0.00.00 4.00 6.00 8.00 5000000 Zoomed in baseline still reveals a completely clean chromatogram 4000000 3000000 000000 000000 0 6.00 8.00 0.00.00 4.00 6.00 8.00 0.00.00 4.00 6.00 8.00 8

Dark Chocolate Analysis.5e+08.4e+08.3e+08 4.e+08.e+08 e+08 9e+07 5 36 8e+07 7e+07 6e+07 5e+07 3 4e+07 6 9 33 3e+07 0 e+07 9 5 3 7 8 30 e+07 3 34 35 37 38 39 40 0.00 5.00 0.00 5.00 30.00 35.00 5 8 7 8000000 7000000 6000000 5000000 4000000 3000000 000000 000000 3 4 5 6 7 8 9 0 3 4 6 Instrument: Run date: Sample description: Amount of sample (g): Sample conditions: Desorb conditions: Split Mode: Precolumn: Column: Carrier: Oven Temp: GCMS: MS Operation: Pen ID: 5800 HSP 7-Nov-6 Dark Chocolate 40 ml vial + vac(30sec) + 5hr equilibration @ 5C 60 C for 5 min. Splitless DB 5m length x 0.5mm ID, 0.5µm film DB 30m length x 0.5mm ID, 0.5µm film He,.5cc/min. constant flow 40 C hold 5min., 0 C/min. to 35C, 35 hold 5min. (solvent delay @ 6min) Agilent 7890B/5977A 34-450 amu,.8 scans/sec 4-0000004 7.50 8.00 8.50 9.00 9.50 0.00 0.50.00.50.00.50 3.00 3.50. Propanoic acid, -methyl-. Butanoic acid, 3-methyl- 3. Butanoic acid, -methyl- 4. Heptanal 5. Pyrazine,,5-dimethyl- 6. Benzaldehyde 7. Pentanoic acid, 4-methyl- 8. Hexanoic acid 9. Pyrazine, trimethyl- 0. Propanoic acid, -hydroxy-, butyl ester. D-Limonene. Ethanone, -(H-pyrrol--yl)- 3. Acetophenone 4. Pyrazine, 3-ethyl-,5-dimethyl- 5. Pyrazine, tetramethyl- 6. -Nonanone 7. Nonanal 8.,6-Octadien-3-ol, 3,7-dimethyl- 9. Octanoic acid, ethyl ester 0. Benzeneacetic acid, ethyl ester. Acetic acid, -phenylethyl ester. Benzeneacetaldehyde,.alpha.-ethylidene- 3. Vanillin 4. Benzoic acid, pent--yl ester 5. Tetradecane 6. 5-Methyl--phenyl--hexenal 7. Pentadecane 8. Butylated Hydroxytoluene 9. H--Benzopyran--one, 3,4-dihydro-8-hydroxy-3-methyl- 30. Dodecanoic acid, ethyl ester 3. Benzophenone 3. Tetradecanoic acid, ethyl ester 33 Caffeine 34. -Heptadecanone 35. Hexadecanoic acid, methyl ester 36. Di-sec-butyl phthalate 37. 9-Octadecenoic acid, methyl ester 38. Linoleic acid ethyl ester 39. 9-Octadecenoic acid, (E)- 40. Octadecanoic acid, ethyl ester 9

Coffee Analysis 9.5e+08.4e+08.3e+08.e+08.e+08 4 8 e+08 6 4 9e+07 8e+07 7e+07 7 6e+07 5 8 5e+07 0 3 4e+07 3e+07 e+07 e+07 3 5 6 7 8 9 0 3 4 7 3 5 6 9 30 0.00 5.00 0.00 5.00 30.00 35.00 Instrument: Run date: Sample description: Amount of sample (g): Sample conditions: Desorb conditions: Split Mode: Precolumn: Column: Carrier: Oven Temp: GCMS: MS Operation: Pen ID: 5800HSP 8-Nov-6 Breakroom coffee 0 ml vial + vac(30sec) + 3hr equilibration @ 60C 60 C for 5 min. Splitless DB 5m length x 0.5mm ID, 0.5µm film DB 30m length x 0.5mm ID, 0.5µm film He,.5cc/min. constant flow 40 C hold 5min., 0 C/min. to 35C, 35 hold 5min. (solvent delay @ 6min) Agilent 7890B/5977A 34-450 amu,.8 scans/sec 4-0000008. Pyridine. 3(H)-Furanone, dihydro--methyl- 3. 3-Furaldehyde 4. -Furanmethanol 5. Butyrolactone 6. Ethanone, -(-furanyl)- 7. Pyrazine,,5-dimethyl- 8. -Furancarboxaldehyde, 5-methyl- 9. Phenol 0. -Furanmethanol, acetate. H-Pyrrole--carboxaldehyde. Ethanone, -(H-pyrrol--yl)- 3. Ethanone, -(-methyl-h-pyrrol--yl)- 4. Phenol, -methoxy- 5. H-Pyrrole, -(-furanylmethyl)- 6. Phenol, 4-ethyl--methoxy- 7. Indole 8. Furan,,'-[oxybis(methylene)]bis- 9. -Methoxy-4-vinylphenol 0. Benzene, 4-ethenyl-,-dimethoxy-. H-Pyrrole, -(-furanylmethyl)-. Phenol,,5-bis(,-dimethylethyl)- 3. Dodecanoic acid, ethyl ester 4. Caffeine 5. -Hexadecanol 6. Hexadecanoic acid, methyl ester 7. n-hexadecanoic acid 8. Isopropyl palmitate 9. Octadecanoic acid 30. Hexadecanamide 3. 9-Octadecenamide, (Z)- Cashew Analysis.e+08 3.e+08 e+08 9e+07 8e+07 7e+07 6e+07 5e+07 4e+07 3e+07 e+07 e+07 Instrument: Run date: Sample description: Amount of sample (g): Sample conditions: Desorb conditions: Split Mode: Precolumn: Column: Carrier: Oven Temp: GCMS: MS Operation: Pen ID: 3 6 7 5 4 5800HSP -Nov-6 Cashews 40 ml vial + vac(30sec) + 48hr equilibration @ 5C 60 C for 5 min. Splitless DB 5m length x 0.5mm ID, 0.5µm film DB 30m length x 0.5mm ID, 0.5µm film He,.5cc/min. constant flow 40 C hold 5min., 0 C/min. to 35C, 35 hold 5min. (solvent delay @ 6min) Agilent 7890B/5977A 34-450 amu,.8 scans/sec 4-0000004 8 0 9 4 5 6 7 8 9 3 0. H-Pyrrole, -methyl-. Toluene 3 Hexanal 4. Ethylbenzene 5. o-xylene 6. Bicyclo[4..0]octa-,3,5-triene 7. Pyrazine,,5-dimethyl- 8. Benzaldehyde 9. Benzeneacetaldehyde 0. D-Limonene. Nonanal. 4H-Pyran-4-one,,3-dihydro-3,5-dihydroxy-6-methyl- 3. Dodecane 4. -Methoxy-4-vinylphenol 3 5.,4-Decadienal, (E,E)- 6. Tridecane, 5-methyl- 4 5 7 6 8 30 9 3 7. Copaene 8. Tetradecane 9. Caryophyllene 0. Humulene. Aromandendrene. Pentadecane 3. Butylated Hydroxytoluene 4..beta.-Bisabolene 5. Hexadecane 6. Octadecane 7. Benzene, (-methylundecyl)- 8. Dibutyl phthalate 9. n-hexadecanoic acid 30. Isopropyl palmitate 3. 9-Octadecenoic acid, methyl ester, (E)- 3. Diisooctyl phthalate 0.00 5.00 0.00 5.00 30.00 35.00 0

3 Rum Analysis.6e+08.4e+08.e+08 e+08.8e+08.6e+08.4e+08.e+08 e+08 8e+07 6e+07 4e+07 e+07 0.00.00 4.00 6.00 8.00 0.00.00 4.00 6.00 8.00 30.00 3.00 34.00 36.00.5e+07 8 5 30.4e+07.3e+07.e+07 4.e+07 e+07 9000000 0 0 9 8000000 7000000 6000000 5000000 4000000 3000000 000000 000000 3 4 5 6 7 9 4 3 6 8 7 9 0 3 5 8 3 3 33 35 34 0.00.00 4.00 6.00 8.00 0.00.00 4.00 6.00 Instrument: Run date: Sample description: Amount of sample (ml): Sample conditions: Desorb conditions: Split Mode: Precolumn: Column: Carrier: Oven Temp: GCMS: MS Operation: Pen ID: 5800 HSP 6-Nov-6 : Rum (50µl BB + 50µl Water) 50µl 0mL vial + vac(30sec) + 5hr equilibration @ 5 C 60 C for 5 min. Splitless DB 5m length x 0.5mm ID, 0.5µm film DB 30m length x 0.5mm ID, 0.5µm film He,.5cc/min. constant flow 40 C hold 5min., 0 C/min. to 300 C, hold 7min. (solvent delay @ 8min) Agilent 7890B/5977A 34-450 amu,.8 scans/sec 4-0000008. 3(H)-Furanone, dihydro--methyl-. -Hexanol 3. Ethanone, -(-furanyl)- 4. Hexanoic acid, ethyl ester 5. Pentanoic acid, 4-oxo-, ethyl ester 6. Phenylethyl Alcohol 7. Butanedioic acid, diethyl ester 8. Octanoic acid, ethyl ester 9. trans-3-methyl-4-octanolide 0. n-decanoic acid. Decanoic acid, ethyl ester. Octanoic acid, 3-methylbutyl ester 3. Dodecanoic acid 4. Benzoic acid, 4-hydroxy-3-methoxy-, ethyl ester 5. Dodecanoic acid, ethyl ester 6. Pentanoic acid,,,4-trimethyl-3-carboxyisopropyl, isobutyl ester 7. Benzophenone 8. Pentadecanoic acid, 3-methylbutyl ester 9. Tetradecanoic acid 0. Ethyl 9-tetradecenoate. Pentadecanoic acid, ethyl ester. Isopropyl myristate 3. -Hexadecanol 4. Pentadecanoic acid, 4-methyl-, methyl ester 5. n-hexadecanoic acid 6. Ethyl 9-hexadecenoate 7. Hexadecanoic acid, ethyl ester 8. -Tetradecyl acetate 9. Isopropyl palmitate 30. 9-Octadecenoic acid (Z)-, methyl ester 3. Heneicosane 3. Methyl stearate 33. Ethyl 9-hexadecenoate 34. Octadecanoic acid, ethyl ester 35. Benzoic acid, tridecyl ester

Analysis of Odor Producing Compounds to Less Than Part Per Trillion Using Vacuum Extraction Evacuation (30 seconds) Desorb Gas Port Micro Seal for Evacuation Silonite coated 36 Stainless Steel Sample extracts much faster at 30x below atmospheric pressure, limited by vapor pressure of water at 5 C 60mg Tenax TA Figure (below) Sorbent Pens containing 60mg of Tenax perform vacuum extraction on 50mL of sample at 5 C for to 0 hours, followed by direct, splitless desorption into a GCMS. The tops of the Sorbent Pens were heated to 50 C to prevent water condensation. Sampled Sorbent 5m, 50um ID, 0.5um DB Vacuum Extraction of water & wine using Sorbent Pens. Vacuum remains even after removal of vacuum source 60m, 50um ID, 0.5um DB Clean Sorbent Pens 5800 Sorbent Pen Desorption Unit on GCMS

Sorbent Pen Vacuum Extraction of Odors Kinetics Study Comparing Recoveries of a 0 PPt Standard in Water After, 3, 8, 6 Hour Extraction Times Extractions performed without salting to prevent adsorbent damage via aerosol transport Temp = 5 C. Sorbent Pens heated to 30 C to prevent water condensation An overnight extraction appears to bring the Pens to near equilibrium with the sample 0000 00000 90000 80000 70000 hour 3 hour 8 hour 6 hour -Methylisoborneal Instrument: Run date: Sample description: 5800 HSP 5//6 Geosmin and Halonanisoles spiked into 50mL filtered water Concentration of sample: 0ng/L Sample conditions: 5mL vial + vac + 00rpm agitation + {,,3,8,6} hours at 5 C Split Mode: Splitless Desorb Conditions: 5min at 60 C Pre-column: DB 5m length x 0.5mm ID, 0.5 µm film thickness Column: DB 60m length x 0.5mm ID, 0.5 µm film thickness Carrier: He,.5mL/min constant flow Oven Temp: 35 C, 0 C/min. to 80 C, hold 4min. GCMS: Agilent 7890B/5977A MS Operation: 33-350 amu,.5 scans/sec 60000 50000 40000 30000 0000 0000 3.45 3.50 3.55 3.60 3.65 3.70 3.75 3.80 3.85 3.90 3.95 4.00 50000 40000 30000 0000 0000 00000 90000 80000 70000 60000 50000 40000 30000 0000 0000 0 hour 3 hour Geosmin 8 hour 6 hour 6.40 6.50 6.60 6.70 6.80 6.90 7.00 7.0 7.0 7.30 Figures,3 (above) Relative responses for target compounds extracted from 0ng/L standards in 50cc filtered water at 5 C, no salt added, 00 rpm agitation, /30th atm vacuum, for,3,8, and 6 hours. A final extraction time of 0 hours was selected for this method with an extraction efficiency between 60-80%. 3

Sorbent Pen Kinetic Study 0000 0000 00000 90000 80000 70000 60000 50000 40000 30000 0000 0000 0 Instrument: Run date: Sample description: 5800 HSP 5//6 Geosmin and Halonanisoles spiked into 50mL filtered water Concentration of sample: 0ng/L Sample conditions: 5mL vial + vac + 00rpm agitation + {,,3,8,6} hours at 5 C Split Mode: Splitless Desorb Conditions: 5min at 60 C Pre-column: DB 5m length x 0.5mm ID, 0.5 µm film thickness Column: DB 60m length x 0.5mm ID, 0.5 µm film thickness Carrier: He,.5mL/min constant flow Oven Temp: 35 C, 0 C/min. to 80 C, hold 4min. GCMS: Agilent 7890B/5977A MS Operation: 33-350 amu,.5 scans/sec.. 3.,4,6-Trichloroanisole,3,5-Trichloroanisole,3,4-Trichloroanisole hour 3 hour 8 hour 6 hour 5.0 5.40 5.60 5.80 6.00 6.0 6.40 6.60 6.80 7.00 7.0 7.40 7.60 7.80 8.00 3 45000 40000 35000 hour 3 hour 8 hour 6 hour,4,6-tribromoanisole 30000 5000 0000 5000 0000 5000 0 8.80 8.90 9.00 9.0 9.0 9.30 9.40 9.50 9.60 Figures 4,5 (above) Relative responses for target compounds extracted from 0ng/L standards in 50cc filtered water at 5 C, no salt added, 00 rpm agitation, /30th atm vacuum, for,3,8, and 6 hours. A final extraction time of 0 hours was selected for this method with an extraction efficiency between 60-80%. 4

Sorbent Pens A revolutionary extraction technology that is quantitative by design. Entech Instruments 07 Agate Court Simi Valley, CA 93065 Phone: 805.57.5939 Learn more online Visit us at entechinst.com Sorbent Pens 7044-5 Entech Instruments 07. Sorbent Pen, MicroValve, Silonite, Micro-QT, MiniCan, and Bottle-Vac, are trademarks of Entech Instruments. All Rights Reserved.