NAVAL SUBMARINE MEDICAL RESEARCH LABORATORY

Similar documents
^- ; asefehs. a»s.^r,--. - "SSSES. v^yj:-- MEDIGÄL. -^j~ ^ z<_^

POLYMACON HYDROPHILIC CONTACT LENSES PRACTITIONER FITTING GUIDE

Visual Acuity through Emergency Breathing Masks. S. M. Luria, Ph.D. James F. Socks, CDR, MSC, USN

NAVAL SUBMARINE MEDICAL RESEARCH LABORATORY

Fitting Guide. Minutes-to-Fit 2.0. by SynergEyes Moving Vision Forward

SUBMARINE BASE, GROTON, CONN. REPORT NUMBER 855

Scleral Fitting Guide

Sofmed breathables XW (comfilcon A) Sofmed breathables XW premium (comfilcon A) Sofmed breathables XW toric (comfilcon A)

Submarine Base, Groton, Conn.

An introduction to modern scleral lenses

SCUBA - self contained underwater breathing apparatus. 5 million sport scuba divers in U.S. 250, ,000 new certifications annually in U.S.

Defense Technical Information Center Compilation Part Notice

Introduction. U.S. Navy Diving Manual (Mar-1970)

Instruction Guide for using Dive Tables (draft)

Acknowledgments. Paragon Vision Sciences Adoption of CRT certification slide for this generic talk. Material Considerations

Submarine Base, Groton, Conn. REPORT NUMBER 690. RESPONSE VARIATIONS OF THREE TYPES OF MICROPHONES PRESSURIZED TO 19 Ata

PHYSICS. Light: Sound:

Oxygen tension under a contact lens. Kenneth A. Poise and Marianne Decker

NOBENDEM. Advanced Decompression Tables

Submarine Base, Groton, Conn. REPORT NUMBER 668

4. Advanced Adventure Diver

Submarine Base, Groton, Conn.

Pardon the Objection (PTO) Contact Lens Clinical Case Debate (2 hours)

Challenges in Undersea Medicine

EXECUTIVE SUMMARY USN DIVE MANUAL REVISION 7 Change A

Dr. Thomas R. Reim President, DreimLens, Inc.

The BE Retainer System Certification Course. Supplement

Defense Technical Information Center Compilation Part Notice

CHAPTER 9 $LU'HFRPSUHVVLRQ

. Vann, Ph.D. P.B. Bennett, Ph.D., D.Sz. ,frice o, Naval Research Contract N C-01.O; February 13, S",i., i " ;, c,,a ppzoved

Orthokeratology. What is Orthokeratology? How does it work?

POTENTIAL BENEFITS OF NAVY DIVE COMPUTER USE IN SHIPS HUSBANDRY DIVING: ANALYSIS OF DIVES CONDUCTED ON THE USS RONALD REAGAN (CVN-76)

The impact of freediving on psychomotor performance and blood catecholamine concentration

NOAA DIVING PROGRAM MINIMUM STANDARD FOR DECOMPRESSION DIVING USING OPEN-CIRCUIT SCUBA EQUIPMENT

MILPERSMAN (703) (901) (901) NAVPERSCOM CUSTOMER SERVICE CENTER

A. Marroni , R. Cali Corleo , C. Balestra , P. Longobardi 4-6, E. Voellm 5-6, M. Pieri 1-6, R. Pepoli 6-7

u. %N&tMz2&foi&INE MEQpa*,G» ER Submarine Base, Groton, Conn. REPORT NUMBER 566 EFFECT ON VISION OF REPEATED EXPOSURE TO CARBON DIOXIDE

(12) Patent Application Publication (10) Pub. No.: US 2006/ A1

Temporary Flying Restriction Due to Exogenous Factors Affecting Aircrew Efficiency

Procedures for ETDRS 4M Refraction and Vision Testing. Katherine M. Burke, BS, CO, COMT CertifEYED Associates, LLC New York, New York

4D Diving and Adventures Safety Protocol Revised Nov 1, 2017

Spherical Soft Contact Lens Fitting. J. Perrigin OPTO 6374 Spring 2017

Decompression Sickness

K*" '«%,T'* -«' 4.- The submarine exwvke*breaks

8. Decompression Procedures Diver

ELEDT S APR24 19 DECOMPRESSION SICKNESS AFFECTING THE TEMPOROMANDIBULAR JOINT. Author:

VISION THROUGH VARIOUS SCUBA FACEMASKS. S. M. Luria, Steven H. Ferris, Christine L. McKay, Jo Ann S. Kinney, and Helen M. Paulson

The Undersea and Hyperbaric Medicine Milestone Project

7. Open Water Scuba Diver

U.S. NAVAL SUBMARINE- MEDICAL CENTER

Biometry tips. Marilyn Watkins-Ramdin, COMT ROUB

A COMPRESSION-DECOMPRESSION SCHEDULE FOR PRODUCING DYSBARIC STRESS IN MATURE RATS. Michael J. Jacey Donald V. Tappan and John J.

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

Patent Foramen Ovale and Fitness

DIVING HABITS AND PRACTICES:

MATHEMATICAL EVALUATION OF MULTI-LEVEL DIVING

PACKAGE INSERT RIGID GAS PERMEABLE CONTACT LENSES FOR ORTHOKERATOLOGY. (hexafocon B)

Centre of Excellence for Subsea Safety

COST (Dollars in Millions) FY04 FY05 FY06 FY07 FY08 FY09 FY10 FY11 Cost to Complete

Defense Technical Information Center Compilation Part Notice

Techniques for Deeper Diving

Demystification of Nitrox, Understanding Mixtures

Note: You will receive no credit for late submissions. To learn more, read your instructor's Grading Policy. A Law for Scuba Divers

1/21/2014. Diving Physics. Introduction

Military Aviation: A Contact Lens Review (Reprint)

Learn Connect Succeed. JCAHPO Regional Meetings 2017

Naval Medical Research and Development Command Research Work Unit MF

200602q PULMONARY FUNCTION AFTER OXYGEN-ACCELERATED DECOMPRESSIONS FROM REPETITIVE SUB-SATURATION AIR DIVES

b. Provide consultation service to physicians referring patients. c. Participate in weekly wound care clinic and biweekly diving medicine clinic.

Common Discrepancies Uncovered on ADCI Diving Contractor & Training Program Audits

Instructions For Use. Recreational Dive Planner DISTRIBUTED BY PADI AMERICAS, INC.

EVALUATION OF INTRAVENOUS THERAPY DEVICES IN THE HYPERBARIC CHAMBER

Definition of a Dive Leader. Experience dives

Underwater Wet Welding Products Operating Instructions

12m. Instructions For Use. 14m. 16m. 18m. Recreational Dive Planner. 20m DISTRIBUTED BY PADI AMERICAS, INC.

Curriculum Vitae. J. Morgan Wells

9. Extended Range Diver

Special Purpose Specification NFQ Level 6. Surface Supplied Diving Operations. Draft for Consultation. Teideal as Gaeilge. Level 6.

Spring 1999 Hyperbaric Medicine Newsletter. Fellows Presentations. Saturation Diving

Defense Technical Information Center Compilation Part Notice

*See Supervised Diver Upgrade procedure #6.12 for certification requirements.

Markers of Decompression Stress of Mass Stranded/Live Caught and Released vs. Single Stranded Marine Mammals

EXPERIENCE IN COLOMBIAN AIR FORCE HYPOBARIC CHAMBER AEROSPACE MEDICAL CENTER (CEMAE)

7. TDI Advanced Wreck Diver Course

Basic Standards for Fellowship Training in Undersea and Hyperbaric Medicine

1. Once you have completed the NAUI Scuba course, you will be qualified to

Diver The Work

Unit 3: The Physiology of Diving and Nitrox

etcadvancedpilottraining.com Upset Prevention and Recovery Training (UPRT) Altitude Awareness Training Situational Awareness (SA)

MEDICAL GENTER. Submarine Base, Groton, Conn. REPORT NUMBER 580 DECOMPRESSION PATTERNS DEVELOPED BY AN INTERDEPENDENT ELECTRIC ANALOG

UNDERWATER HEARING IN MAN: II. A Comparison of Temporary Threshold Shifts Induced by 3500 Hertz Tones in Air and Underwater

SWISS UNDERWATER HYPERBARIC MEDICAL SOCIETY

The Allure of the Deep

Teaching students about how technology enables science through building Aquarius Habitats.

Perforating Center of Excellence TESTING SERVICES OVERVIEW

Altitude Diver Standard Version (2010/00)

Ascent to Altitude After Diving

9. Extended Range Instructor

Accommodation responses and refractive error

Counterdiffusion Diving: Using Isobaric Mix Switching To Reduce Decompression Time

Transcription:

NAVAL SUBMARINE MEDICAL RESEARCH LABORATORY SUBMARINE BASE, GROTON, CONN. REPORT NO. 1102 EFFECTS OF HYPERBARIC CONDITIONS ON CORNEAL PHYSIOLOGY WITH HYDROGEL CONTACT LENSES by Joseph F. Molinari and James F. Socks Naval Medical Research and Development Command Research Work Unit MR00001.01-5104 Released by: C. A. HARVEY, CAPT, MC, USN COMMANDING OFFICER Naval Submarine Medical Research Laboratory f4sj 2 October 2&W Approved for public release; distribution is unlimited.

EFFECTS OF HYPERBARIC CONDITIONS ON CORNEAL PHYSIOLOGY WITH HYDROGEL CONTACT LENSES By Joseph F. Molinari, O.D., M.Ed, James F. Socks, CDR, MSC, USN NAVAL SUBMARINE MEDICAL RESEARCH LABORATORY REPORT NUMBER 1102 NAVAL MEDICAL RESEARCH AND DEVELOPMENT COMMAND Research Work Unit MR00001.01-5104 I I: Approved and Released by C. Ä. Harvey, CAPT, MC, USN Commanding Officer NAVSUBMEDRSCHLAB Approved for public release; distribution unlimited

SUMMARY PAGE ' PROBLEM Navy divers who wear spectacles for the correction of defective visual acuity often dive either without visual correction, or with a prescription faceplate where practical. This creates the problem of storing their spectacles while diving and finding them again when they surface. Contact lenses could solve this problem. However, it is unknown what detrimental effects might occur to corneal physiology while diving. FINDINGS Bubbles formed toward the periphery of hydrogel (soft) contact lenses during decompression, but they did not significantly affect vision or corneal physiology, and were not noted subjectively. APPLICATION Provides documentation that soft contact lenses can safely be worn while diving. ADMINISTRATIVE INFORMATION This research was conducted as part of the Naval Medical Research and Development Command Work Unit MR00001.01-5104 - "Effects of hyperbaric conditions on corneal physiology." it was submitted for review on 21 May 1987, approved for publication on 2 October 1987, and designated as NSMRL Report No. 1102. PUBLISHED BY THE NAVAL SUBMARINE MEDICAL RESEARCH LABORATORY ii

ABSTRACT Four chamber subjects wearing various hydrogel contact lenses underwent hyperbaric exposures to 150 Feet Sea Water (FSWG) with a bottom time of 30 minutes for a total of 24 lens trials. No displacement of the lenses was reported, but bubbles formed in twenty-five percent of the trials. They were not, however, noticed by the subjects and did not significantly affect vision or corneal physiology. Pt

INTRODUCTION There has been an explosion of interest in the undersea world. Approximately two million Americans have received scuba instruction; 50,000 of them are actively engaged in sport diving (1). Divers with refractive errors usually dive either without corrections or, if available, with prescription faceplates. Wearing hydrogel contact lenses during underwater activities with self-contained underwater breathing apparatus (SCUBA) offers visual advantages, but the risks to civilians as well as the military have been inadequately researched. The United States Navy expects its divers to perform their specialties under a wide range of diving conditions. Each of these specialties and situations requires a different degree of visual performance. For the working diver, underwater vision is more critical than vision on the surface. So many divers who require spectacles solve that problem by wearing face-plates with bonded refractive corrections to improve their uncompensated refractive errors under water. However, Navy combat divers need to have optimum vision not only while they are in the water but also while conducting surface operations. When these men who wear face-plates with bonded corrections come to the surface, they cannot see adequately until they find and put on their spectacles. One option for improving the vision of divers is to use contact lenses. These include standard hard (PMMA), gas permeable rigid, and hydrogel contact lenses. Clinicians for f years have observed that most sport and military divers wear J A contact lenses without adverse effects (2,3). However, two studies have shown transient adverse effects of wearing standard hard contact lenses. Bubbles seem to occur in the precorneal tear film behind the rigid (PMMA) lenses after exposures to a hyperbaric environment resulting in corneal edema, dimpling of the corneal epithelium, and reduced visual acuity (4,5). The bubble content in the precorneal tear film under conditions of decompression are thought to be nitrogen. As the pressure decreases, the bubbles expand. This causes the ophthalmic signs described above. Oxygen deficiency does not seem to be a factor as it is in hypobaric environments. Lens displacement, which could result in ocular injury or disruption of vision, is also of concern. iss 8.'

Several investigations have demonstrated the potential of hydrogel lenses for improving vision in scuba diving (1,2,6). Although one study revealed better vision and normal eye comfort when diving in fresh water, the lenses were sometimes lost when the face mask was removed (1). However, Williamson feels that lens displacement at the surface with Bionite(R) soft contact lenses is minimal and the lenses have many advantages over PMMA and spectacles for underwater use. The purpose of our investigation was to evaluate various commercially available hydrogel contact lens designs and materials during hyperbaric exposures. This was done using low, medium, and high water content hydrogel contact lens on trained subjects in a hyperbaric chamber with high humidity. METHOD Subjects The volunteer subjects were two women and two men who were qualified as hyperbaric chamber test subjects. All were myopic. Each was randomly fit with a different unmatched pair of lenses chosen from the three hydrogel types: a low water polymacon 38%, a medium water bufilcon A 55%, or a high water surfiicon A 71% water spherical content lens. Commercially available nonpreserved saline contact lens solutions were used to insert the lenses. Informed consent was obtained from the subjects after the protocol had been fully explained. Procedure Gas transfer and corneal responses due to the lenses were evaluated both under pressure and at the surface using a slit lamp and keratometer. The subjects' corneal lens relationship was photographed with a slit lamp camera if unusual phenomena were observed. Lens comfort was evaluated subjectively, and visual acuity was tested at the surface, pre- and post-dive, using Snellen acuity. During the hyperbaric exposures, the subjects breathed compressed air in the double-lock hyperbaric chamber. Exposure depth in the Naval Submarine Medical Research Laboratory (NSMRL) chamber was to 45.5M (150 ft) of seawater, with a 30 minute bottom time. All dives followed standard Navy air dive tables for hyperbaric exposures with decompression stops at 20 feet for eight minutes and 10 feet for 24 minutes. Subjects remained in the chamber area for 60 minutes post-dive for safety considerations and were subsequently dismissed.

m Each subject performed three dives, alternating the lens type between the.eyes each time. All dives were conducted with the same investigator in the chamber. The dives took place in the mornings with an inter-dive interval of 24 hours which is within the safety factor for repetitive dives as specified by the USN Diving Manual (7). RESULTS 2 i The subjects commented favorably on the contact lenses. They reported that their lenses felt the same or better after reaching the bottom and during the decompression phase of the dives than on the surface. No subjects reported lens displacement or visual changes throughout the dives. The chamber investigator first observed bubbles under lenses of subjects upon reaching the first decompression stop at twenty feet. The bubbles became more numerous during travel to the surface. They were very symmetrical and progressively grew until they fractured into smaller bubbles by the time the surface had been reached. They remained under the lenses for at least 30 minutes after surfacing. :, When the lenses were removed after surfacing, dimpling or indentation of the corneal epithelium was observed where the bubbles had been previously noted. One subject was examined three hours post-dive. Biomicroscopy revealed very slight dimpling of the cornea and mild fluorescein pooling where the bubbles had occurred under the lenses. This subject had the largest bubbles, but no symptoms. Of the eight trials per lens over the three dives, bubbles formed during 4 of the 24 total trials. This was more apparent in the medium water content hydrogel lenses. The low water and high water content materials had only 1 incident of bubble formation during the trials.

DISCUSSION All subjects thought the lenses felt the same or better after reaching the bottom and during the decompression phase of the dives than on the surface. The additional moisture in the air may cause additional hydration of the lenses; when the lenses are dryer, the fit becomes tighter. One important finding is that no lens was displaced in any of the bubble formation incidents nor in any of the trials. For the sport diver as well as the military diver, this means that these lenses may be safely worn instead of the cumbersome modified eye-wear in the mask. In addition, two of the subjects who wore high water content lenses showed keratometric mire distortion. We cannot explain the etiology of the distorted mires with high water content lenses on two subjects after the dive. More exposures may give more information. Bubble formation in this study appears to relate to the phenomena noted by Simon & Bradley (5). While the greatest number of bubbles occurred with medium water contact lenses, the limited number of exposures makes it difficult to relate bubble formation to materials alone. Lens design may be a significant fact as well as corneal toricity and diameter. These variables are presently being evaluated. These results have shown no negative effects from wearing soft contact lenses during diving. Assuming that no more serious symptoms will appear with longer and deeper exposures and with subsequent slower decompression, they suggest that these lenses are safe, and that more extensive trials may be undertaken to define the limits under which these lenses can be used.

5 ACKNOWLEDGMENT We thank the NSMRL staff members who participated as subjects and the NSMRL engineering technicians for their support in the operation of the hyperbaric chamber. REFERENCES 1. Cotler, J. Soft contact lens testing on fresh water-scuba divers. Contact Lens 1981; Oct Dec 7(4): 323-326. py % H-?{?' 2. Williamson, D. E. Soft-contact lenses and scuba diving. Eye, Ear, Nose and Throat Monthly, 1971; Jan: 64-68. 3. Hurlock, R., Malin, A. H. Case Report: Underwater contact lens corrections. Am. J. Optom. & Physiol. Optics, 1973; 50(8): 653-655. 4. Dixon, J. M., Young, C. A. Jr., and Baldone, J. A. Complications associated with the wearing of contact lenses. JAMA 1966; 195: 901-903. 5. Simon, D. and Bradley, M. Adverse effects on contact lens wear during decompression. JAMA 1980; 244: 1213-1214. 6. Vinger, P. F. (Ed). Ocular Sports Injuries. Boston: Little, Brown, 1981, p.147. 7. U.S. Navy Diving Manual, Vol 1. Air Diving, Washington, D.C.: Navy Department, June 1985. m 'W