Easy to operate. Wide space

Similar documents
Easy to operate even for biginners. Set up the number of test. Possible to select from 1 to times

RG2 Gripper Datasheet Version 1.6

Product instruction manual Easymount Sign Laminators EM-S1400C, EM-S1600C, EM-S1400H, EM-S1600H

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation

Pneumatic high-pressure controller Model CPC7000

Operating Instructions Part No

COSMO INSTRUMENTS CO., LTD.

PTC INSTRUMENTS 2301 Federal Ave Los Angeles CA Phone: Model 500 Automatic Operating Stand Type 3

DFX II Series. Digital Force Gauge

Pneumatic high-pressure controller Model CPC7000

Description Total stroke Maximum Recommended Page in mm gripping force in N workpiece weight in kg

[Instruments for vacuum measurement, checking and adjustment] 3

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Compact Ejectors. Compact Ejectors SCPi / SMPi Suction rate from 75 l/min to 185 l/min

Model 130M Pneumatic Controller

Electronic gas volume corrector model DGVC-04

Multistage Ejector Series ZL

Multistage Ejector Series ZL

Additel 780 Series Pressure Controller

THE UNIVENTOR 400 ANAESTHESIA UNIT

ALGE Water Polo Scoreboard

SonoMeter 30 Energy Meters

Additel 780 Series Pressure Controller

SSL. Smart Valve Positioner.

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options

SSR. Smart Valve Positioner.

Qi Litre Ultrasonic Cleaner

UNIMAT Basic. Material Testing Machine. for the. Quality Control. with. Software (intern) for Stand Alone Usage

The Univentor 1250 Anaesthesia Unit

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cartridge, Size 10

Inverse Proportional Pressure-Relief Cart., Size 2 4

TH-1800-T TRX-700-CNG Converter

Project Title: Pneumatic Exercise Machine

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

Precision pressure sensor Basic version Model CPT6020

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

628 Differential Pressure Decay Leak Tester

DPS-400 SERIES DPH-100 SERIES

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

MEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15

Type 4708 Supply Pressure Regulator

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Proportional Pressure-Relief Cartridge Valve, Size 2...4

HumiSys HF High Flow RH Generator

The All New DIAMOND & DIAMOND BT

MANUAL KPS Pressure Control Valve

TECHNICAL INFORMATION

Gas density monitor With integrated transmitter Model GDM-100-TI

Inverse Proportional Pressure-Relief Cart., Size 2 4

Draw-wire system SZG165

Series MTS300 Motorized Test Stands

Digital Pressure Gauge Main features: Data Sheet: BIT02B.417.R6.EN COVER on request

Digital Flow Switch. Series PFM7

ANZAI AZ-733VI. Respiratory Gating System. since 1976

Force Test Stand Model ESM301 / ESM301L. Version 2. User s Guide

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Gripping rotary modules

User s Guide. Model ESM1500 FORCE TEST STAND

Pressure regulators Manually operated Fine setting valves. Brochure

SAUTER FK Version /2016 GB

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

PWG-S. Application example. Pneumatic 2-Finger Angular Gripper Universal Gripper. Sizes. Gripping moment 5.98 Nm Nm. Weight 0.21 kg 1.

user leaflet GAUGING TRANSDUCERS

Digital Melting Point Apparatus

Hand-held pressure calibrator with integrated pump Model CPH6600

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.

Gripping modules Pneumatic 2-finger parallel gripper Long-stroke gripper for small components Gripping force 120 N..

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

A4s Operation Manual

brands you trust. DEPA DH Next Generation Air Operated Double Diaphragm Pumps

Additel 780 Series Pressure Controller

Hand lever valves VHER

Opening Angle 76º 30º [337] 45º 76º 30º [213] 45º 76º 30º [169] 45º 76º 30º [337] 45º 76º 30º [337] 45º 76º 30º [128] 45º 76º 30º [404] 45º 76º 30º

User Manual. MEGP 25 Electric Gripper. Document version: 1.1

Technical Information Conducal CLY421

Product Information. Gripper for small components MPC

KEG PUMP. Range of Electric Keg Pumps

Traysealer T 100. Tray packaging in the smallest space

Mouse and Rat Tail Cuff Blood Pressure Systems from 1-24 Animals. Mouse rat tail cuff blood pressure system components

Aquavar SOLO 2 Frequently Asked Questions

OC Panel High Limit Aquastat Kit, Manual Reset p/n

Hoisting Equipment Cable puller & Accessories

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

ECL Comfort 110, application 131 (valid as of software version 2.00)

Hoses and Lances 20,000 PSI

Reliability and flexibility in a compact design

Additel 761 Automated Pressure Calibrators Selection Guide

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Instruction Manual Differential Pressure Transmitter

Saab Seaeye Cougar XT Compact

September 10, 2014 Revision 2. Puncher Unit-BE1/BF1/BG1/BH1 Service Manual

SPECIFICATIONS PARTICLE SENSOR KS-19F Higashimotomachi, Kokubunji, Tokyo , Japan

Transcription:

With a force gauge and attachments, compression/tensile/pealing tests are possible up to 1000N/2500N. It provides consistent testing speed and direction, offering highly accurate test results. MX2-2500N This is a model with FA option. Cable is NOT included. MX2-1000N/2500N Feature More precise measurement Rigidity is high, so it is hardly bend even when the maximum force is added. Different tests are possible by changing attachments With a variety of attachments, different types of sample can be tested. A force gauge *It is NOT included. Retort pouch durability test Nozzle tension strength test *We provide special attachments only for you. Wide space Table size is 200*100(mm), wide enough to put sample easily. Easy to operate Good angle of the control panel makes it easier to operate and see its monitor even though you do not stay seated. Easy to operate even for biginners With one dial Set up the number of test Possible to select from 1 to Set up the pausing time Possible to set up pausing time Prevention against sensor break-down Speed adjustment Set-up the number of test Fine adjustment of a force gauge s position are possible. 65535 times Ideal for repetition test at selected place Ideal for durability test It stops operation before force over capacity is added with Z series force gauge and its cable used together. *Optional cable is necessary. *We cannot assure the perfect prevention against sensor break-down 1 / 7

Force-displacement Measurement* Graph drawing Data management Simple measurement IMADA CO.,LTD. [Application Example] Retort pouch compression test Metallic board breaking test Thick wire tensile test Recommended test stand: MX2-1000N/2500N Possible to test pressure-resistant of retort pouch with PR-2500N, compression fixture. Recommended test stand: MX2-1000N/2500N Possible to test bending strength of metallic board. Recommended test stand: MX2-2500N Possible to test thick wire s harness and its covering tear or slip. [Configuration Example] Measuring instrument Software Cable Attachment Mechanical force gauge PSH series N/A N/A For measuring maximum value Digital force gauge ZTS series Connection to external equipment Comparator function Force-displacement measuring unit FSA series* Graph drawing software Force Recorder Standard Force-time graph Connection cable CB-518 Overload prevention Please select attachments or fixtures fit for your sample. We will advise for choosing it. We also provide special attachment according to your sample. Please feel free tocontact us for advice. - A test stand with a linear scale (MX2-1000N-FA, MX2-2500N-FA) - A digital force gauge ZTA series - Force displacement graphing software (Force Recorder Professional) - Connection cable (CB-718) - Attachments MX2-1000N/2500N can be upgraded for force-displacement measurement. With FSA series, you can perform force-displacement analysis very easily. * Please refer to specifications for FSA series for further information. Other models are also available. 2 / 7

Functions IMADA CO.,LTD. [MX2-1000N/2500N Specifications] [Functions/Operating environment/accessories] Speed Model MX2-1000N MX2-2500N Capacity Maximum force to be added 1000N 2500N Speed range available 10-300(mm/min) Rigidity Stroke limit Display of speed Force control Overload prevention Mode Timer Counter The body Accessories Unit 10-20mm/min 20-100mm/min 100-300mm/min Able to set up speed every 0.5mm/min Able to set up speed every 5mm/min Able to set up speed every 10mm/min Max gap of distances from table to tip of [Standard type]less than 0.5mm gauges, under no force and max force applied. [Long stroke]less than 1.0mm Controllable with upper/lower stroke limit sensor Speed is displayed digitally Operation is controllable at selected force.*1 Operation automatically stops when force over capacity is applied.*1*2 Manual/Jog/Cycle mode Possible to set up pausing time every 0.1 sec, up to 99min59.9sec Count or set up the number of tests (Max 65535 times)*3 Operating temperature Operating humidity Power voltage Power consumption 0-+40 degree Celsius 35-70%, avoid condensation AC100~240V,50/60Hz (Please specify from 100.120.230V. Accessories are different) SizeStandard type 280*421*660(mm) 280*410*644(mm) [Long stroke] [280*421*960(mm)] [280*410*944(mm)] Weight Approx. 19kgf Approx. 26kg Manual, Power cable, Grip mounting adaptor, High capacity gauge mounting plate (only for MX2-1000N),Small gauge mounting plate (only for MX2-2500N), Cover,Spare hues, and Tools. Manual mode JOG mode Cycle mode Possible to keep a force gauge moving upward or down word while the buttons are pressed. 50W Possible to move a force gauge in small increments, by turning its dial Measurement starts only by pressing a button according to operating conditions fixed in advance automatically. *1 Possible only when ZP/Z2 series force gauge and digital force amplifier are connected with an optional cable. *2 We do not assure you that it can prevent overload completely. *3 If you need to test repeatedly more than 65535 times, please feel free to contact us. [Force gauges mountable to MX2-2500N] PSH DS2 ZT (2 to 1000N) ZT (2500 to 5000N) 3 / 7

[Option] Specification can be changed flexibly according to your measurement conditions. We meet your needs like Faster speed is necessary Longer stroke is needed Wider space for sample is required [Option example] Option Specification Long stoke (To extend stroke by 300mm)*1 Length measuring instrument (For displacement measurement) Speed change (Change from standard type)*1 External signal input (To mount connector for external I/O) FA type (A linear scale for measuring displacement built in) *2 *1 Please feel free to contact us if you would like to change stroke and range of speed. *2 Please refer to Configuration Example on page2. Model MX2-1000N-L MX2-2500N-L MX2-1000N-S MX2-2500N-S MX2-1000N-V MX2-2500N-V MX2-1000N-CN MX2-2500N-CN MX2-1000N-FA MX2-2500N-FA [MX2-1000N-CN, MX2-2500N-CN option example] Start input Interlock input Operating state output Possible to start and stop operation with a foot pedal switch connected to MX2-1000N/2500N. A box surrounding MX2-1000N/2500N is available, and makes it possible to stop operation when its door is open. It notifies you operating status by buzzer or light. [Option example for safety] Anti-scattering panel Adapter for safety against overturning [preparing] It is useful for the prevention against sample scattering and good for your safety as well It prevents MX2-2500N from overturning in disasters such as earthquake. 4 / 7

[Dimensions] [MX2-1000N] r t *Unit is mm in the dimensions and the table above. MX2-1000N MX2-1000N-L H 660 960 When DS2/ZT(2N to 1000N) is mounted 71 When ZT(2500N to 5000N) is mounted 75 When DPU(lower range of 500N) is mounted 69 When DPU(higher range of 1000N) is mounted 73 When DS2 is mounted 342 642 When ZT(2N to 1000N)is mounted 334 634 ZT(2500N to 5000N) is mounted 351 651 DPU (2N to 10N) is mounted 324 624 DPU (20N to 500N) is mounted 324 624 DPU (1000N to 5000N) is mounted 247 547 5 / 7

[MX2-2500N] r t MX2-2500N MX2-2500N-L H 644 944 When DS2/ZT(2N to 1000N) is mounted 72 When ZT(2500N to 5000N) is mounted 71 When DPU(lower range of 500N) is mounted 70 When DPU(higher range of 1000N) is mounted 74 When DS2 is mounted 311 611 When ZT(2N to 1000N)is mounted 303 603 ZT(2500N to 5000N) is mounted 310 610 DPU (2N to 10N) is mounted 276 576 DPU (20N to 500N) is mounted *2 274 574 DPU (1000N to 5000N) is mounted 258 558 *Unit is mm in the dimensions and the table above. *2 Optional adapter is necessary to combine DPU-1000/2000/5000N.Please contact us for more details. 6 / 7