Easy to operate even for biginners. Set up the number of test. Possible to select from 1 to times

Similar documents
Easy to operate. Wide space

RG2 Gripper Datasheet Version 1.6

Product instruction manual Easymount Sign Laminators EM-S1400C, EM-S1600C, EM-S1400H, EM-S1600H

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation

Model 130M Pneumatic Controller

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000

Operating Instructions Part No

COSMO INSTRUMENTS CO., LTD.

PTC INSTRUMENTS 2301 Federal Ave Los Angeles CA Phone: Model 500 Automatic Operating Stand Type 3

DFX II Series. Digital Force Gauge

Description Total stroke Maximum Recommended Page in mm gripping force in N workpiece weight in kg

[Instruments for vacuum measurement, checking and adjustment] 3

Compact Ejectors. Compact Ejectors SCPi / SMPi Suction rate from 75 l/min to 185 l/min

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

SSR. Smart Valve Positioner.

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

SonoMeter 30 Energy Meters

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options

Electronic gas volume corrector model DGVC-04

ANZAI AZ-733VI. Respiratory Gating System. since 1976

UNIMAT Basic. Material Testing Machine. for the. Quality Control. with. Software (intern) for Stand Alone Usage

Multistage Ejector Series ZL

Multistage Ejector Series ZL

DPS-400 SERIES DPH-100 SERIES

Additel 780 Series Pressure Controller

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

ALGE Water Polo Scoreboard

SSL. Smart Valve Positioner.

Additel 780 Series Pressure Controller

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

Qi Litre Ultrasonic Cleaner

Draw-wire system SZG165

User s Guide. Model ESM1500 FORCE TEST STAND

Hoisting Equipment Cable puller & Accessories

MEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15

TECHNICAL INFORMATION

The All New DIAMOND & DIAMOND BT

HumiSys HF High Flow RH Generator

THE UNIVENTOR 400 ANAESTHESIA UNIT

Gas density monitor With integrated transmitter Model GDM-100-TI

Product Information. Gripper for small components MPC

The Univentor 1250 Anaesthesia Unit

Inverse Prop. Pressure-Relief Cart., Size 2 4

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Inverse Proportional Pressure-Relief Cart., Size 2 4

Gripping rotary modules

TH-1800-T TRX-700-CNG Converter

Project Title: Pneumatic Exercise Machine

SAUTER FK Version /2016 GB

Opening Angle 76º 30º [337] 45º 76º 30º [213] 45º 76º 30º [169] 45º 76º 30º [337] 45º 76º 30º [337] 45º 76º 30º [128] 45º 76º 30º [404] 45º 76º 30º

Precision pressure sensor Basic version Model CPT6020

Gripping modules Pneumatic 2-finger parallel gripper Long-stroke gripper for small components Gripping force 120 N..

PWG-S. Application example. Pneumatic 2-Finger Angular Gripper Universal Gripper. Sizes. Gripping moment 5.98 Nm Nm. Weight 0.21 kg 1.

628 Differential Pressure Decay Leak Tester

user leaflet GAUGING TRANSDUCERS

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Digital Melting Point Apparatus

User Manual. MEGP 25 Electric Gripper. Document version: 1.1

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.

Proportional Pressure-Relief Cartridge Valve, Size 2...4

MANUAL KPS Pressure Control Valve

Traysealer T 100. Tray packaging in the smallest space

Technical Information Conducal CLY421

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cartridge, Size 10

Series MTS300 Motorized Test Stands

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

Digital Pressure Gauge Main features: Data Sheet: BIT02B.417.R6.EN COVER on request

Aquavar SOLO 2 Frequently Asked Questions

Dräger RZ 7000 Test Equipment

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Digital Flow Switch. Series PFM7

Force Test Stand Model ESM301 / ESM301L. Version 2. User s Guide

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

Mouse and Rat Tail Cuff Blood Pressure Systems from 1-24 Animals. Mouse rat tail cuff blood pressure system components

50KN stress rig for use on SALSA

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Pressure regulators Manually operated Fine setting valves. Brochure

Service Test Unit for ROSS Proportional Valves RESK

EEF. Fatigue Testing Unit PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Engineering and Technical Teaching Equipment

SPECIFICATIONS PARTICLE SENSOR KS-19F Higashimotomachi, Kokubunji, Tokyo , Japan

Instruction Manual Differential Pressure Transmitter

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

MPG-plus. Application example. Pneumatic 2-Finger Parallel Gripper Gripper for small components. Gripping force 38 N 175 N. Sizes

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

Stand-Alone Bubble Detection System

Hand-held pressure calibrator with integrated pump Model CPH6600

brands you trust. DEPA DH Next Generation Air Operated Double Diaphragm Pumps

Type 4708 Supply Pressure Regulator

SEIKO MULTI TIMING SYSTEMS

ORG. Application example. Special Grippers O-ring Assembly Gripper. Weight 1.35 kg. Ring diameter O.D. Assembly appr.ø 5 mm.. ø 160 mm.

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

A4s Operation Manual

Transcription:

With a force gauge and attachments, compression/tensile/peeling tests are possible up to 1000N/2500N. It provides consistent testing speed and direction, offering highly accurate test results. MX2-2500N This is a model with FA option. Cable is NOT included. A force gauge *It is NOT included. MX2-1000N/2500N Feature More precise measurement Since the rigidity of the axis is high and it is hardly bent, more precise measurement is possible. Different tests are possible by changing attachments With a variety of attachments, different types of sample can be tested. Retort pouch durability test Nozzle tension strength test *We provide special attachments only for you. Wide space Table size is 200*100(mm), wide enough to put sample easily. Easy to operate Good angle of the control panel makes it easier to operate and see its monitor Easy to operate even for biginners With one dial Speed adjustment Set-up the number of test Fine adjustment of a force gauge s position are possible. Set up the number of test Possible to select from 1 to 65535 times Ideal for repetition test Set up the pausing time Possible to set up pausing time at selected place Ideal for durability test Prevention against sensor break-down and operation control with an optional cable It stops operation before force over capacity is added, or its operation is controlled according to load values When you combine it with a ZT series force gauge and an optional cable. *We cannot assure the perfect prevention against sensor break-down. 1 / 7

Force-displacement Measurement* Graph drawing Data management Simple measurement IMADA CO.,LTD. [Application Example] Retort pouch compression test Metallic board breaking test Thick wire tensile test Recommended test stand: MX2-1000N/2500N Possible to test pressure-resistant of retort pouch with PR-2500N, compression fixture. Recommended test stand: MX2-1000N/2500N Possible to test bending strength of metallic board. Recommended test stand: MX2-2500N Possible to test thick wire s harness and its covering tear or slip. [Configuration Example] Measuring instrument Software Cable Attachment Mechanical force gauge PSH series N/A N/A For measuring maximum value Digital force gauge ZTS series Connection to external equipment Comparator function Force-displacement measuring unit FSA series* Graph drawing software Force Recorder Standard Force-time graph Connection cable CB-518 Overload prevention *1 Force control Please select attachments or fixtures fit for your sample. We will advise for choosing it. We also provide special attachment according to your sample. Please feel free to contact us for advice. - A test stand with a linear scale (MX2-1000N-FA, MX2-2500N-FA) - A digital force gauge ZTA series - Force displacement graphing software (Force Recorder Professional) - Connection cable (CB-718) - Attachments MX2-1000N/2500N can be upgraded for force-displacement measurement. With FSA series, you can perform force-displacement analysis very easily. *1 We cannot assure the perfect prevention against sensor break-down. * Please refer to specifications for FSA series for further information. Other models are also available. 2 / 7

Functions IMADA CO.,LTD. [MX2-1000N/2500N Specifications] [Functions/Operating environment/accessories] Speed Model MX2-1000N MX2-2500N Capacity Maximum force to be added 1000N 2500N Speed range available 10-300(mm/min) Stroke Maximum height of a sample Rigidity Stroke limit Display of speed Unit 10-20mm/min 20-100mm/min 100-300mm/min Max distance from table to tip of measurement shaft of force gauge when the head is on top Please refer to t of Dimensions in page 5 and 6. Able to set up speed every 0.5mm/min Able to set up speed every 5mm/min Able to set up speed every 10mm/min 290mm Max gap of distances from table to tip of [Standard type] less than 0.5mm gauges, under no force and max force applied. [Long stroke] less than 1.0mm Controllable with upper/lower stroke limit sensor Speed is displayed digitally Force control Operation is controllable at selected force. *1 Overload prevention Mode Timer Counter The body Accessories Operation automatically stops when force over capacity is applied.*1*2 Manual/Jog/Cycle mode Possible to set up pausing time every 0.1 sec, up to 99min59.9sec Count or set up the number of tests (Max 65535 times)*3 Operating temperature Operating humidity Power voltage Power consumption 0-+40 degree Celsius 35-70%, avoid condensation AC100~240V,50/60Hz (Please specify from 100.120.230V. Accessories are different) Size Standard type 280*421*660(mm) 280*410*644(mm) [Long stroke] [280*421*960(mm)] [280*410*944(mm)] Weight Approx. 19kgf Approx. 26kg Manual, Power cable, Grip mounting adaptor, High capacity gauge mounting plate (only for MX2-1000N),Small gauge mounting plate (only for MX2-2500N), Cover, Spare hues, and Tools. Manual mode JOG mode Cycle mode Possible to keep a force gauge moving upward or down word while the buttons are pressed. 50W Possible to move a force gauge in small increments, by turning its dial Measurement starts only by pressing a button according to operating conditions fixed in advance automatically. *1 Possible only when ZT series force gauge and digital force amplifier are connected with an optional cable. *2 We do not assure you that it can prevent overload completely. *3 If you need to test repeatedly more than 65535 times, please feel free to contact us. [Force gauges mountable to MX2-2500N] PSH DS2 ZT (2 to 1000N) ZT (2500 to 5000N) 3 / 7

[Option] Specification can be changed flexibly according to your measurement conditions. We meet your needs like Faster speed is necessary Longer stroke is needed Wider space for sample is required [Option example] Option Specification Long stoke (To extend stroke by 300mm) *1 Length measuring instrument (For displacement measurement) Speed change (Change from standard type) *1 External signal input (To mount connector for external I/O) FA type (A linear scale for measuring displacement built in) *2 *1 Please feel free to contact us if you would like to change stroke and range of speed. *2 Please refer to Configuration Example on page2. Model MX2-1000N-L MX2-2500N-L MX2-1000N-S MX2-2500N-S MX2-1000N-V MX2-2500N-V MX2-1000N-CN MX2-2500N-CN MX2-1000N-FA MX2-2500N-FA [MX2-1000N-CN, MX2-2500N-CN option example] Start input Interlock input Operating state output Possible to start and stop operation with a foot pedal switch connected to MX2-1000N/2500N. A box surrounding MX2-1000N/2500N is available, and makes it possible to stop operation when its door is open. It notifies you operating status by buzzer or light. [Option example for safety] Anti-scattering panel Adapter for safety against overturning [preparing] It is useful for the prevention against sample scattering and good for your safety as well It prevents MX2-1000N/2500N from overturning in disasters such as earthquake. 4 / 7

[Dimensions for MX2-1000N] *Unit is mm [Size] r t *1 MX2-1000N MX2-1000N-L H 660 960 When DS2/ZT(2N to 1000N) is mounted 71 When ZT(2500N to 5000N) is mounted 74 When DPU(lower range of 500N) is mounted 69 When DPU(higher range of 1000N) is mounted 73 When DS2 is mounted 310 610 When ZT(2N to 1000N)is mounted 300 600 When ZT(2500N to 5000N) is mounted 340 640 When DPU(2N to 10N) is mounted 325 625 When DPU(20N to 500N) is mounted 315 615 When DPU(1000N to 5000N) is mounted 345 645 *1 The value is without attachments. Please note that the maximum height of sample will be shorter than t when you combine a gauge or a load cell with attachments. 5 / 7

[Dimensions for MX2-2500N] r t *1 MX2-2500N *Unit is mm MX2-2500N-L H 644 944 When DS2/ZT(2N to 1000N) is mounted 72 When ZT(2500N to 5000N) is mounted 71 When DPU(lower range of 500N) is mounted 70 When DPU(higher range of 1000N) is mounted 74 When DS2 is mounted 320 620 When ZT(2N to 1000N)is mounted 315 615 When ZT(2500N to 5000N) is mounted 320 620 When DPU(2N to 10N) is mounted 290 590 When DPU(20N to 50N) is mounted 285 585 When DPU(1000N to 5000N) is mounted*2 210 510 *1 The value is without attachments. Please note that the maximum height of a sample will be shorter than t when you combine a gauge or a load cell with attachments. *2 An optional adaptor is needed to mount DPU series (from 1000N to 5000N). Please contact us for further information. 6 / 7

[Cautions] *The contents may be changed without notice in advance. *This product is designed for measurement purpose only. *Do not copy the contents without permission. *Force gauge is not included but necessary for force measurement. 7 / 7