R S 280 is a modular parallel sect. Directional Control Valve RS RS In relation to its flow capacity its installation

Similar documents
SDM to 8 sections monoblock valve D1WWDA02A

Monoblock Directional Control Valve RMB 202

directional control valve series cv691

Fitted with a main pressure relief valve and a load check valve on every working section.

Directional Control Valves Technical Information Model 1500

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

DNS. Monoblock directional control valves DNS - Directional control valve

Monoblock directional control valves ML - Directional control valve

D62 - D63 Directional Control Valve l/min

Directional Controls

Directional Control Valve P70

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE

Directional Control Valve P70 Open or Closed Centre Proportional Valve Series. Catalogue HY /UK July, 2005

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

PRESSURE COMPENSATORS TECNORD

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Proportional Directional Valve System

Inverse Prop. Pressure-Relief Cart., Size 2 4

Pressure reducing valve, pilot operated

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Pressure reducing valve, direct operated

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

Axial piston pumps type PVC

Inverse Proportional Pressure-Relief Cart., Size 2 4

Axial piston pumps type PVC

Leak free Pipe Rupture Valve for Excavators

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

3-Way Pressure-Reducing Cartridge, Size 2 4

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Leak-Free Load-Control Valve SAE ½ psi flange

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Intrinsically safe solenoid valves on/off controls - ATEX certification

Electrically Operated Pressure-Relief Cartridge, Size 10

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Inverse Proportional Pressure-Relief Cart., Size 2 4

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Inverse Proportional Pressure-Relief Cartridge, Size 10

* Different spooltypes up to 120 l/min. in combination with simultaneously control.

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)

Pressure reducing valve, pilot operated, Model 3DR

F130 Mobile Directional Control Valve

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

F130 Mobile Directional Control Valve

Size 10 (D05) p max 320 bar (4600 PSI) Technical Features. Technical Data. Port dimensions ZB10A(B) SMT_0019 ZB K -

Digital directional & flow control valves D-DF(R)G

Hydraulic Reliability & Preventive Maintenance Report

PTS1120TSJB PTS2120TSTSJB

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

SPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B:

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

Auxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003

4/2 way Pneumatic Solenoid Valve

Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve)

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

Proportional Throttle Cartridges, Size 16

Air preparation units

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PLD 03 T A CASAPPA S.p.A.

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

SINGLE VALVE WITH LOW-FLOW BYPASS

Pressure reducing valve, direct operated

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

SATURNSERIES INTERCHANGE > ISO (for the couplings)

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve

Directional Controls

LMU100/200 Series. Standard Specifications

shutoff valves 900 Series psig Manual Shutoff Valves

Cooler-Bypass Thermostat Valve, Size 16

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump

2/2-Way Solenoid Control Valve

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

Data Sheet Issue A

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

kysimply Unique Single Seat

2-way flow control valve Model 2FRM 6

Controllers DR, DP, FR and DFR

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Introduction. Part one: Identify the Hydraulic Trainer Components

PVK OPEN LOOP PUMPS. Bulletin E

Two-stage valve type NE

Damcos PHP Portable hand pump unit 5 l. Product Data Sheet September 2014 SD E04

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Directional Control Valves. Technical Information

Series 4 Cv= Air-Pilot operated valves. 3-way/2-position, 5-way/2-position, 5-way/3-position

Directional Control Valve L90LS Proportional, Load-Sensing and Pressure Compensated. Catalogue HY /UK July, 2005

Transcription:

Directional Control Valve RS 280 3 RS 2802 3102RS28001 R S 280 is a modular parallel sect nal valve. Suitable applications are medium sized and big truck loaders, medium sized backhoe loaders and other applications where there is need for good control characteristics. RS 280 is stackable up to 10 sections. Above 10 sections after factory approval. The mating part of the sections are carefully designed to minimize the risk of external leakage. RS 280 is designed for a maximum working pressure of 280 bar whitin the recomended flow range of 40 110 l/min. In relation to its flow capacity its installation sizes are small. Whit its open attachment ears it is easy to install and separate valve blocks can be connected parallel. The inlet section of RS 280 provides both inlet and outlet ports. There is provision for a pressure gauge port as option. The outlet section is furnished whit three alternative outlet ports. By means of a plug fitted through the T4 port into the S1 port high pressure carry over is achieved, both sideways and upwards.

Technical Data Max system pressure (depending on appl.):...350 bar 35 (MPa) Max number of working/intermediate sections (depending on application):... 10 Max recoended pump flow:...180 l/min Spring force, spool control 9, in neutral position:...100 N (10kp) Spring force, spool control 9, fully selected spool:...120 N (12kp) Max continuous return line pressure:......20 bar (2,0 MPa) Pressure drop PT PA/B Hydraulic fluid temperature range for continuous operation:...15 C + 80 C Contamination level: Normally... Equal to or better than ISO 18/14 At high system pressures and/or remote control... Equal to or better than ISO 16/12 Hydraulic fluid viscosity range:...10400 2 /s (cst) Spool leakage at 100 bar och 30 2 /s (cst):...<10 cm 3 /min A/BT Control characteristics Graphs show principal function, valid for manually operated spools. Oil viscosity 30 /s (cst) at 50 C. PA/B A/BT I II Standard spools = load pressure 50 = load pressure 250 PA/B A/BT I II Sspools = load pressure 50 = load pressure 250 bar

Dimensions, Weight L, LF1, LF2, LA and LB dimensions acc. to tables below. All dimensions in. Type G thread = BSP thread. SAE port threads available on request. Section Weight Kg Inlet 4,4 Working 5,0 Intermediate 4,4 Outlet 5,0 Length 9 9M 1015 L81 L83 LA 41 72 87 102 99 Spool control type (see page 5) P/PP EP MM HD HPDM EH EHP 3W 4W HPD max max 134 72 189 185 LB 92 72 92 100 110 No. sect L LF1 LF2 1 153 134 97 2 200 181 144 3 247 228 191 4 294 275 238 5 341 322 285 6 388 369 332 7 435 416 379 8 482 463 426 9 529 510 473 10 576 557 520 S1** Carryover ** Plug mounted in port S1.

Main relief valve TBB 201 Relief Valve and Auxiliary Valves Differential area relief valve for the main Setting range: 35 65 bar 65 95 bar 95 125 bar 125 160 bar 160 200 bar 200 240 bar 240 250 bar Service line relief valve TB 202 Differential area relief valve for the secondary Setting range: 35 65 bar 65 95 bar 95 125 bar 125 160 bar 160 200 bar Anticavitation valve SB 250 Pressure drop bar 240 200 160 120 80 40 Symbol 0 200 240 bar 240 300 Symbol Check valve for equalising vacuum in the secondary Pressure drop bar 240 200 160 120 80 40 0 Pressure drop bar 10 8 Relief function characteristic Oil viscosity 32 cst at 40 0 C 0 120 60 Oil viscosity 32 cst at 40 0 C l/min Flow 0 60 120 l/min Flow Oil viscosity 32 cst at 40 0 C 6 Symbol 4 2 Line relief and Anticavitation valve TBS 202 Combination of relief and anticavitation valve for the secondary 0 0 20 40 l/min Flow Characteristics: See particulars of the line relief valve and anticavitation valve Symbol

Spool Controls Symbol Description Type Symbol Description Type Marine version Detent in positions 1, 2 and 3. 9 9M 10 External kickout from spool, pos. 3. *** External kickout from spool, pos 2 and 3.. *** L82 L83 Detent in position 4. Detent in positions 3 and 4 11 PP= pneumatic proportio PP nal. 12 Electric pneumatic on/off. EP Rated voltage 12/24V= * In addition to presented spool controls following standard spool controls are available: MM HPDM 3W, 4W, Contact us for further infromation. Detent in position 2. Detent in position 3. Detent in position 2 and 4. External kickout from spool, pos 2. *** marine/enclosed hand lever. hydr. prop., with hand lever. spool controls for cable control. 13 Hydraulic on/off.*** Pilot pressure min 7 bar. Pilot pressure max 40 bar. 14 Hydr. proportional.*** Pilot pressure 6 16 bar. HPD4 Pilot pressure max 40 bar. 15 El. hydr. on/off.. *** Flow demand 1 l/min for operation. Pilot pressure min 7 EH bar. Pilot pressure max 40 L81 bar.duty factor 100%.** Spools * Rated current 350/190mA. Energizing power 2,3 W. Min. holding power 0,15 W. Max voltage variation. ±5%. Duty factor 100%. Conn. M5.For hose 6 x 1. **Rated voltage 12/24V =.Rated current 180/90 ma. Max voltage variaation ± 16%. Selection time to extr. pos. 200 ms, spring centering time 110 ms. *** Connection: 1/4" BSP HD Symbol II I A B III IV P T Recoended flow range, l/min 4075 50100 60110 80130 120180 1D 1F 1FS 2F 2FB 1HR 1HSR 1G 1K 1KR 2K 2KB 3K 1Q 4K 4Q Notes Further standard spools and variants are available. R = spool with round solid lever end, for joystick hand lever.

System alternatives The intermediate section for RS 270, thanks to its carefully thoughtthrough design, allows a number of different valve internal and external system alternatives. Existing valve equipped with the intermediate section, without dismantling, can easily be altered to other system configurations. See below: K1 K2 K3 K5 Internal circuit type Single circuit Valve internally parallel coupled. Main relief valve for the system can be positioned in the intermediate section. Single circuit Valve internally tandem coupled, i.e. working sections upstream of the intermediate section with fully selected spools have complete priority as far as flow supply is concerned in relation to working sections downstream of the intermediate section. A second main relief valve, positioned in the intermediate section, can be used to reduce the pressure to working sections downstream from the intermediate section. Dual circuit The intermediate section divides the valve into two completely separated circuits. Tank gallery is coon. Multicircuit operation is possible according to the same pattern. Dual circuit Tandem coupling between first and second First circuit is always solely supplied from the first pump. Second circuit is always supplied from the second pump. When first circuit is inactive then the second circuit is supplied from both pumps. Multicircuit operation is possible according to the same pattern.

Valve example The hydraulic circuit plan shows a possible valve design equipped with an intermediate section furnished for system alternative K3 two separate circuits with coon tank channel. The inlet section in shown valve example has type designation I04A and is equipped with main relief valve TBA201 for the first The four working sections are all of standard design S04A, they are differently equipped in terms of spool functions and spool controls and they are furnished with line relief and anticavitation valves or service line valve plugs. The load check valves in the supply channel, are standard. The intermediate section (see page 6), which has designation M02A,is assembled, whit main relief valve. Pump connection for secondcircuit is port P2. The type designation of the outlet section as shown is U04A. S1 is not plugged. Thus this valve example can not be used for high pressure carry over (connected with dir. valves downstream).