High Flow Engine Start Reducing Station

Similar documents
INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

PRO-50 Instrument Supply Regulator

Piloted Non-Return Valves

GE Oil & Gas. Mooney * Flowgrid * Slam Shut Regulator. Delivering accuracy, performance and protection

HELIUM PRESSURE REGULATOR

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Type EZH Relief or Backpressure Regulator

Improve Reliability of Turbomachinery Lubrication and Sealing Systems

Precision Pressure Regulators. Precision Fluidics

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Description Advanced Features Typical Applications

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

Unit 24: Applications of Pneumatics and Hydraulics

Float Operated Level Controllers

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

B84G - Excelon Plus Modular System General purpose filter/regulator

1200 Series Pressure Regulators

Norval Pressure regulator

Flow meter. bellow vaporizer. APL valve. Scavenging system

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

829S1 Series Flexflo Pilot

VACUUM REGULATORS CONTENTS

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

64 Series Pressure Reducing Regulators

Model 4000 Pressure Controller

SB AXIAL FLOW VALVES

Pressure Automated Calibration Equipment

MEGR-1912 Instruction Manual

When the pressure is on, turn to our high-pressure pumps

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

CAPITAL CONTROLS SERIES NXT3000

Operation Manual Piston Sensed Gas Pressure Regulators

Electropneumatic Transducer (I/P) Installation, Operation and

V DGX Series. Direct-Operated Regulators Manual D103834X012

ECS Protector Nitrogen Inerting Vent (PAV-WN)

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Type FL Pressure Reducing Regulators

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

MEGR-1627 Instruction Manual

Pressure Reducing Valve for Steam Type 2333 A

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

Pilot Check Valve: Metal Body Type

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

B84G - Excelon Plus Modular System General purpose filter/regulator

TECHNICAL DATA. Q = C v P S

Inert Air (N2) Systems Manual

299H Series Pressure Reducing Regulators

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

RB 4700 Commercial & Industrial Regulator

TECHNICAL DATA. Q= Cv S

SUPER PRECISION AIR RELAYS

Type 299 Pressure Reducing Regulators

Type 4708 Supply Pressure Regulator

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

R84G - Excelon Plus Modular System Pressure regulators

1305 Series Pressure Reducing Regulators

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Installation, Operation, and Maintenance Manual

Installation and User Manual

OPERATING AND MAINTENANCE MANUAL

Introduction. Part one: Identify the Hydraulic Trainer Components

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

DN300 DN2000 C Plunger Valve

Bermad Pressure Reducing. Model: 42T

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

Petro-Chemical & Analyzer Sampling Systems

QBS Electronic Pressure Regulator

Pressure Regulators. Operating Instructions. Instrumentation

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

ADVANCED AIRLINE FILTER INSTRUCTION MANUAL

SERIES SAFETY VALVE

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

WW-720. Pressure Reducing Control Valve

MWEA MAINTENANCE SEMINAR SPECIALTY VALVES POWER GLOBES

AIRLINE-SERIES HELMET AIR FILTER

KOBOLD KSM FLOWMETER. User Instructions

HP/UHP Spring-Loaded Regulator

Aperval Pressure Regulators

Related Products: Auto Drain Valve. Model/Specifications. Model

WW-730. Pressure Sustaining/Relief Control Valve

553 Series.

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Installation, Operation, and Maintenance Manual

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Reclaim Basic Set Up

Air Preparation. Regulators, Pressure Regulators, Lubricators and Accessories. Keeping the World Flowing

EXPERIMENT 1 AIR PRESSURE CONTROL SYSTEM

Transcription:

igh Flow Engine Start Reducing Station FEATURES Isolators and bypass facility allows supply of air during regulator maintenance. Non-isolatable relief valve protections of Downstream pressure gauge isolator with vent for gauge blow-down. 50 micron inlet filter protects regulator and downstream equipment. valves with block in situ. Material selection provides good resistance to corrosive marine environment. Application: Brief bursts of high flow energy for engine start application. Design Pressure: 6000 psig (420 bar) at 100 F (38 C) Temperature Range: -4 to 240 Fahrenheit (116 F) Max. Flow Rates: To Customer Specifications. Shock tested to Grade A medium-weight shock, Class 1, Type A ull mounted, MI-S901D Vibration tested to MI-STD-167-1, Type 1 Filter Inlet Stop Relief Outlet Stop Outlet Gauge Inlet Pressure Regulator Bypass SCEMATIC DIAGRAM eight lbs Drawing No. ength, idth, eight, (Overall) EXP 1539 1400 3" 3½ 30.4 26 15 1 of 6

Breathing Air Reducing Station Regulator isolators and bypass facility for ease of maintenance. Non-isolatable relief valve for protection of Downstream pressure gauge isolator with vent for gauge blow-down. 50 micron inlet filter protects regulator, downstream valves and equipment. Cartridge principle allows maintenance of all valves with block left in situ. All materials and cleaning compatible with breathing requirements. Applications: Divers Quality Air, orkshop Compressed Air, Engine Start Air Design Pressure: 6000 psig (420 bar) at 100 F (38 C) Temperature Range: -4 to 240 Fahrenheit (116 C) Max. Flow Rates: To Customer Specifications. Shock tested to Grade A medium-weight shock, Class 1, Type A ull mounted, MI-S901D Vibration tested to MI-STD-167-1, Type 1 Filter Inlet Stop Relief Outlet Stop Outlet Gauge Inlet Pressure Regulator Bypass SCEMATIC DIAGRAM Model No. eight lbs ength, idth, eight, CC-0505-101 110 ⅜" ⅜ 8.3 6 3.75 2 of 6

Breathing Air Twin Reducing Station Regulator isolators and bypass facility allows supply of air during maintenance. Non-isolatable relief valve protections of Upstream and downstream pressure gauge isolators with vent for gauge blow-down. 50 micron inlet filter protects regulator and downstream equipment. valves with block in situ. Twin Regulators give back-up in the event of failure of one regulator. Applications: Breathing air supply to hyperbaric chambers. Design Pressure: 4000 psig (280 bar) at 100 F (38 C) Temperature Range: -4 to 240 Fahrenheit (116 C) Max. Flow Rates: To Customer Specifications. Shock tested to 80g for 5 milliseconds in half sine wave. Any orientation. Vibration tested to MI-STD-167-1, Type 1 Inlet Stop Inlet Gauge Regulator 1 Regulator 1 Outlet Outlet Relief Outlet Gauge 140 Filter Regulator 2 SCEMATIC DIAGRAM Bypass Regulator 2 Outlet 165 320 eight lbs Model No. ength, idth, eight, RSA 01 136 3" 3½ 12.6 6.5 5.5 3 of 6

Two Stage Gas Reducing Station Regulator isolators and bypass facility allows supply of air during maintenance. Non-isolatable relief valve protects Upstream and downstream pressure gauge isolators with vent for gauge blow-down. 50 micron inlet filter protects regulator and downstream equipment. Cartridge principle allows full maintenance of all valves with block in situ. Applications: Air supply to all functions or gas supply. Design Pressure: 280 bar (4000 psig) at 40 C Temperature Range: -25 to 120 C Max. Flow Rates: To Customer Specifications. Shock tested to 80g for 5 milliseconds in half sine wave. Any orientation. Vibration tested to MI-STD-167-1, Type 1 (available on request). Second StageReducer First Stage Reducer Relief To Gauge Relief Exhaust INET OUTET Gauge External Sensing Port Model No. eight kg ength, idth, eight, RSA 45 ¼ NPS ½ NPS 13.6 12.5 6.8 4 of 6

2 Stage igh Flow Reducing Station with Remote Actuation For Rocket aunch Application Outlet stop valve is actuated using 80psig pneumatic actuator gives remote on/off operation. Non-isolatable relief valve protects downstream system and pipe work. Intermediate relief valve not required. valves with block welded in situ. Material selection provides good resistance to humid environment on site. Instrumentation drillings removes requirement for substantial pipe work Application: Remote Switch on/off of high flow supply of air or gas. Design Pressure: 6000 psig (400 bar) at 100 ºF (38ºC). Temperature Range: -4 to 248ºF (-20 to 120ºC). Max. Flow Rate: To Customer Specifications. Relief valve blow-down 10% and accumulation 10%. Outlet pressure ranges from 1Barg to 280Barg with 10% lockup and 10% droop. Non-return valve cracking pressure 0.1Barg. Switched non-return valve provides indication of relief valve operation ATMOSPERIC VENT OUTET GAUGE PI3 VC2 VGS3 VP6 VS2 VR2-2 VR2-1 SITC PS3 INET COUNTER CN2 Drawing No. eight lbs ength, idth, eight, RRU 6010-RB/1 1000 1½" 3½ 18.7 17 13.2 Rev. 7/31/14 5 of 6

Single Stage Reducing Station with Remote Actuation for elium For Rocket aunch Application Outlet stop valve is actuated using 80psig pneumatic actuator gives remote on/off operation. Non-isolatable relief valve protects downstream system and pipe work. Intermediate relief valve not required. valves with block welded in situ. Material selection provides good resistance to humid environment on site. Instrumentation drillings removes requirement for substantial pipe work. Application: Remote Switch on/off of helium shroud gas supply. Design Pressure: 6000 psig (400 bar) at 100 ºF (38ºC). Temperature Range: -4 to 248ºF (-20 to 120ºC). Max. Flow Rate: To Customer Specifications. Relief valve blow-down 10% and accumulation 10%. Outlet pressure ranges from 1Barg to 280Barg with 10% lockup and 10% droop. Non-return valve cracking pressure 0.1Barg. Switched non-return valve provides indication of relief valve operation. ATMOSPERIC VENT OUTET GAUGE PI3 VC2 VGS3 VP6 VS2 VR2-2 VR2-1 SITC PS3 INET COUNTER CN2 Drawing No. eight lbs ength, idth, eight, RRU 5003-RB/1 132 ¾" ¾ 8.3 8.3 5.1 Rev. 7/31/14 6 of 6