TABLE OF CONTENT

Similar documents
TABLE OF CONTENT

Pipeline Pigging and Hydrostatic Test

SECTION 2 APPLICATION OF FUNDAMENTALS

2.9 GENERAL REQUIREMENTS FOR GROUP I

Hazardous Location Coding System - NEC 500. Type of Protection. XP = Explosionproof. IS = Intrinsically Safe Apparatus

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

SULFUR RECOVERY UNITS Performance Test Arrangements (Operating Manuals)

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

TABLE OF CONTENT

TechNote FM APPROVAL: HAZARDOUS LOCATION EQUIPMENT CLASSIFICATION

Hazardous Location Coding System - For Division. Class I / II / III, Division 1 / 2 Type of Protection. XP = Explosionproof

API RECOMMENDED PRACTICE 500 THIRD EDITION, DECEMBER 2012 ERRATA, JANUARY 2014


Inerted Vessels: Preventing Hazards Caused by Gas Buoyancy

TECHNOLOGY GUIDE NO. 12

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

ENGINEERING STANDARD FOR HAZARDOUS AREA ORIGINAL EDITION DEC. 1994

INOGATE Technical Secretariat UK Experience European Standards Implementation Key Expert Phil Winnard Session 2 Georgia, October 2015

NFPA 496. Standard for. Purged and Pressurized Enclosures for Electrical Equipment Edition

The Omron STI Hazardous Location

STORAGE OF COMPRESSED GAS CYLINDERS (SAF-SPI-15)

CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS IN GAS UTILITY AREAS. Gerry Pickens

BASIC NATIONAL ELECTRIC CODE APPLICABLE TO MEASUREMENT. Gerry Pickens. Atmos Energy 810 Crescent Centre Drive Franklin, TN 37067

Transport of gas tanks for motor vehicles

Dangerous Substances & Explosive Atmospheres Regulation 2002 The Basics. Richard Cowen Dip SH, Dip RSA, CMIOSH, MIIRSM, FRSPH, GI Fire E

CHAPTER 6 VENTILATION REQUIREMENTS

PSSI 36 General Confined Spaces, Tunnels, Culverts and Similar Spaces

API MPMS Chapter 17.6 Guidelines for Determining the Fullness of Pipelines between Vessels and Shore Tanks

Hazardous (Classified) Locations

Wireless I/O, Connecting Remote Sensors in a Wide Range of Environments

ST/SG/AC.10/C.3/2016/8. Secretariat. United Nations. Transport of gas tanks for motor vehicles. Introduction

TABLE OF CONTENTS PART 2 - CONFINED SPACES

COMPRESSED GASES CHAPTER 53

Transport of gas tanks for motor vehicles

AIDGC PRESENTATION MARCH 2006 HAZARDOUS AREAS STANDARDS & CLASSIFICATION

Compressed Gases and Cryogens

RESOLUTION MSC.397(95) (adopted on 11 June 2015) AMENDMENTS TO PART A OF THE SEAFARERS' TRAINING, CERTIFICATION AND WATCHKEEPING (STCW) CODE

SAFETY MANUAL PURGING, VENTING & DRAINING PROCEDURE TABLE OF CONTENTS 1. INTRODUCTION SCOPE DEFINITIONS PROCEDURE...

Session 13: Fundamentals of Area Classification Studies

THE PETROLEUM INDUSTRY Code of Practice

Gas Fired Residential Heating Boilers

New Hampshire Public Utilities Commission CFR 49 Part 192 Regulations. MINIMUM Pipeline Safety Regulations

ENGINEERING STANDARD FOR HAZARDOUS AREA SECOND EDITION JANUARY 2016

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 Utilities Gas Emergencies Revised

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

SAFEWORK PRACTICES EQUIVALENCY PROCEDURE FOR ACCESSING FLOATING ROOF TANKS ON STORAGE TANKS IN SERVICE CAT A-2 SOP #33

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

ENGINEERING STANDARD FOR CLASSIFICATION OF FIRES AND FIRE HAZARD PROPERTIES FIRST EDITION FEBRUARY 2016

API Standard Venting Atmospheric and Low-Pressure Storage Tanks: Nonrefrigerated and Refrigerated

FLAMMABLE MIXTURE ANALYSIS FOR HAZARDOUS AREA CLASSIFICATION

UTAS EH&S INSTRUCTION No. 036 June 2012 Revision No. 3. Purging of Flammable Gas Equipment and/or Piping (Explosion Hazard)

CODE OF GUIDANCE. For the Storage of Full & Empty LPG Cylinders and Cartridges. Page 1

Hydrogen in Air % to 2%

ISO INTERNATIONAL STANDARD. Gas cylinders Safe handling. Bouteilles à gaz Sécurité de manutention. Second edition

ISO INTERNATIONAL STANDARD. Small craft Liquefied petroleum gas (LPG) systems

This document is a preview generated by EVS

CLASSIFICATION OF AREAS FOR ELECTRICAL INSTALLATIONS AT HYDROCARBON PROCESSING AND HANDLING FACILITIES

Cal/OSHA T8 CCR 1536 Cal/OSHA T8 CCR 4799 Cal/OSHA T8 CCR 4845 Cal/OSHA T8 CCR 4848

Compressed Gases Storage and Handling Safety Policy. Individual Unit Function: Safety Procedure No.: SOP-0103 Page: 1 of 6

Safety Data Sheet. Zero Air 1 PRODUCT AND COMPANY IDENTIFICATION. Manufacturer NorLab a division of Norco 898 W. Gowen Rd.

BODY OF KNOWLEDGE TANK ENTRY SUPERVISOR CERTIFICATION PROGRAM Revision 2, October 2013

SAFETY PRINCIPLES FOR PRESSURE REGULATORS FOR MEDICAL OXYGEN CYLINDERS

BODY OF KNOWLEDGE API TES TANK ENTRY SUPERVISOR

STORAGE OF HAZARDOUS CHEMICAL AGENTS (HCA)

Each cryogenic liquid has its own specific properties, but most cryogenic liquids can be placed into one of three groups:

Section I Date Prepared June 11, 2011 Signature of Preparer (optional) One BernzOmatic Drive. Medina, NY 14103

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Department of Physics Standard Operating Procedures (SOP) Approved by: Physics Safety Committee

STCW Code Table A-V/1-1-1 Specification of minimum standard of competence in basic training for oil and chemical tanker cargo operations

Doc No: WELDHOT Midland Engineering Co., Inc. Initial Issue Date 12/14/15 Safety Management System

GUIDANCE FOR MANAGING THE RISKS ASSOCIATED WITH END OF LIFE LPG VEHICLES

Inerting System Design for Medium Speed Vertical Spindle Coal Pulverizers TABLE OF CONTENTS

SUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE

Quebec Quebec Tel : Fax : MSDS: Methane, Oxygen in Nitrogen Mixture PRODUCT INFORMATION

Dip Tanks Containing Flammable or Combustible Liquids Self-Inspection Checklist

Material Safety Data Sheet (MSDS)

Cylinder Exchange Training Manual

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the. IGF Code

Note: Implementing a permit-required confined space program in accordance with section 5157 shall meet the requirements of this section.

RULES PUBLICATION NO. 119/P

PURPOSE OF THE POLICY

Vision Painting Inc Safety Management System

ESSENTIAL SAFETY RESOURCES

Fires and Explosions: What You Need to Know to Prevent Them

Focus on VOC Emissions Reduction Using an Oxygen Based Inerting Control System For Inert Gas Blanketing of Chemical Process Vessels

UNSATURATED POLYESTER RESIN Version: 1.8 Print Date: 06/04/2006

ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS (EEHA) HAZARDOUS AREA CLASSIFICATION STANDARD

DSEAR-Classification of Hazardous Areas (Zoning) and Selection of Equipment

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

HOT SHOT OPERATING INSTRUCTIONS AND OWNER S MANUAL. Model SPC-500. (Propane Torch)

Chapter 7. Coal Cargoes. Properties and Characteristics 7.1

Safety Data Sheet: QUORAL BARRIER RESIN (BR)

Date Issued: 27 September 2018

MATERIAL SAFETY DATA SHEET

CONFINED SPACES. American Galvanizers Association Phone: (720) Fax: (720) Scope

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

ENGINEERING STANDARD FOR GEOMETRIC DESIGN OF ROADS AND STREETS ORIGINAL EDITION MAR. 1996

RESOLUTION A.567(14) adopted on 20 November 1985 REGULATION FOR INERT GAS SYSTEMS ON CHEMICAL TANKERS

CALIFORNIA STATE UNIVERSITY, LOS ANGELES WELDING, CUTTING, AND HOT WORK OPERATIONS. October 2007

Transcription:

Page : 1 of 12 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES 2 DEFINITIONS AND TERMINOLOGY 3 GENERAL DESIGN 4 EXTENT OF LOCATIONS 6 General Conditions 6 General Release Sources 6 Special Systems 9 Special Release Sources and Equipment 9 CONVERSION TO ZONE FROM DIVISION 12

Page 2 of 12 SCOPE This Project Standards and Specifications shall be used for the electrical classification of areas in which flammable gases or vapors are, or may be, present, in the air in quantities sufficient to produce explosive or ignitable mixtures. Classification of new facilities or extensions/additions to existing facilities shall be performed using the Class I/Zone/ method per API RP 505 and, for selected facilities as specified below, NFPA 70. REFERENCES Throughout this Standard the following dated and undated standards/codes are referred to. These referenced documents shall, to the extent specified herein, form a part of this standard. For dated references, the edition cited applies. The applicability of changes in dated references that occur after the cited date shall be mutually agreed upon by the Company and the Vendor. For undated references, the latest edition of the referenced documents (including any supplements and amendments) applies. 1. American Petroleum Institute (API) API RP 500 API RP 505 Recommended Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as Class I, Division 1, and Division 2 Recommended Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as Class I, Zone 0, Zone 1, and Zone 2 2. National Fire Protection Association (NFPA) NFPA 30 NFPA 30A NFPA 59 NFPA 70 NFPA 325 Flammable and Combustible Liquids Code Automotive and Marine Service Station Code Storage and Handling of Liquefied Petroleum Gases at Utility Gas Plants National Electrical Code (NEC) Fire Hazard Properties of Flammable Liquids, Gases, and Volatile Solids NFPA 496 Purged and Pressurized Enclosures for Electrical Equipment

Page 3 of 12 DEFINITIONS AND TERMINOLOGY A combustible liquid - is a liquid that has a flash point greater than 54 C. A flammable liquid - is a liquid that has a flash point equal to or less than 54 C. A Classified Location: - A Class I, Zone 0 location is an area that meets one of the following: o in which ignitable concentrations of flammable gases or vapors are present continuously o in which ignitable concentrations of flammable gases or vapors are present for long periods of time - A Class I, Zone 1 location is an area that meets one of the following: o in which ignitable concentrations of flammable gases or vapors are likely to exist under normal operating conditions o in which ignitable concentrations of flammable gases or vapors may exist frequently because of repair or maintenance operations or because of leakage o in which equipment is operated or processes are carried on, of such a nature that equipment breakdown or faulty operations could result in the release of ignitable concentrations of flammable gases or vapors and also cause simultaneous failure of electrical equipment in a mode to cause the electrical equipment to become a source of ignition o that is adjacent to a Class I, Zone 0 location from which ignitable concentrations of vapors could be communicated, unless communication is prevented by adequate positive pressure ventilation from a source of clean air and effective safeguards against ventilation failure are provided. - A Class I, Zone 2 location is an area that meets one of the following: o in which ignitable concentrations of flammable gases or vapors are not likely to occur in normal operation and if they do occur they will exist only for a short period o in which volatile flammable liquids, flammable gases, or flammable vapors are handled, processed, or used, but in which the liquids, gases, or vapors normally are confined within closed containers of closed systems from which they can escape, only as a result of accidental rupture or breakdown of the container or system, or as the result of the abnormal operation of the equipment with which the liquids or gases are handled, processed, or used. o in which ignitable concentrations of flammable gases or vapors normally are prevented by positive mechanical ventilation, but which may become hazardous as a result of failure or abnormal operation of the ventilation equipment

Page 4 of 12 o that is adjacent to a Class I, Zone 1 location, from which ignitable concentrations of flammable gases or vapors could be communicated, unless such communication is prevented by adequate positive pressure ventilation from a source of clean air, and effective safeguards against ventilation failure are provided. A nonclassified location - is one which is completely outside Class I, Zone 0, Zone 1 and Zone 2 classified locations. Also in the "nonclassified location" category are those enclosed spaces, not containing a release source, in Class I, Zone 0, Zone 1, Zone 2 locations, that are pressurized or purged by inert gas or by air taken from nonclassified locations by systems that comply with type "X" or type "Z" purging, respectively, per NFPA 496. A volatile liquid - is defined as any of the following: a flammable liquid, a combustible liquid at a temperature within 8 C of its flashpoint or at a temperature equal to or above its flashpoint. An adequately ventilated indoor location - s one that meets the conditions noted in API RP 505 Section 6.6 on Ventilation. An adequately ventilated outdoor location - is any space which is open and free from obstruction to the natural passage of air through it, vertically or horizontally. Such locations may be roofed over and/or closed on one side. Combustible gases and vapors - gases and vapors that can form flammable or explosive mixtures with air. Heavier-than-air gas/vapor - is a gas/vapor with a density under release conditions that is equal to or greater than 75% of that of air at atmospheric pressure and 15 C. Lighter-than-air gas/vapor - is a gas/vapor with a density under release conditions that is less than 75% of that of air at atmospheric pressure and 15 C. GENERAL DESIGN 1. Area Classification Drawings shall be developed for all facilities where flammable liquids, gases, or vapors are produced, processed, stored or handled. This applies to new facilities, or extensions/additions to existing facilities. The classification shall be performed using the Class I/Zone/ method per the guidelines within API RP 505 and this standard. Extensions/additions to existing facilities already classified by the "Division"

Page 5 of 12 method can be classified by the same method with approval of the Chief Fire Prevention Engineer. 2. Ventilation Indoor locations shall be designated "adequately ventilated" if the conditions noted in Section 6.6, Ventilation, of API RP 505 are met. 3. Mixtures of Gases or Vapors of Different Ignition Temperatures Where a mixture of gases or vapors is composed of gases/vapors of different ignition temperature, designation of the ignition temperature of the mixture shall be by any one of the following methods: - The ignition temperature of that gas/vapor in the mixture having the lowest individual ignition temperature per NFPA 325. - The ignition temperature of the mixture as determined by a test specified in NFPA 325. 4. Mixtures of Gases of Different Densities For a gas or mixture of gases composed entirely of lighter-than-air gases, the extent of the classified location shall satisfy the requirements for lighter-thanair vapors. Where a mixture is composed of lighter-than-air and heavier-than-air gases and the mixture density is less than 75% of the density of air at standard conditions, the extent of the classified area shall satisfy the requirements for lighter-than-air vapors. Where the mixture has a density equal to or greater than 75% of air at standard conditions, it shall be considered as a heavier-than-air vapor for area classification purposes. 5. Mixtures of Gases of Different s Where a mixture contains gases of different s per NFPA 70, the area classification shall satisfy the requirements for every for which the aggregate volume of gas constitutes 30% or more of the mixture composition. 6. Electrical Area Classification Drawings The development of the electrical classification drawings shall follow the guidelines presented within API RP 505. These drawings shall be produced as part of any project proposal, final design, and as-built issue of drawings for any capital or maintenance project that creates or changes the extent of an electrically classified location. The drawings shall, as a minimum, show the following information: - The demarcation of the Zone 0, 1, 2 and unclassified areas, both vertically and horizontally via plan, elevation, and section views.

Page 6 of 12 - The minimum ignition temperature of the mixture of gases/vapors creating each classified location. - The type of gas or vapor in each of the classified areas. This shall be presented as the name(s) of the gas/vapor and by the IIA, B, or C designations defined within NFPA 70 and API RP 505. 7. Typical relationship between Zone classification and the presence of flammable mixtures can be seen in the following rule-of thumb. Zone Flammable Mixture Present 0 1000 or more hours/year (10%) 1 10 < hours/year < 1000(.1% to 10%) 2 1 < hours/year <10 (.01% to.1%) unclassified Less than 1 hour/year (.01%) Refer to API RP 505 section 6.5.8 for further details. EXTENT OF LOCATIONS General Conditions The distances specified in this section are the minimum distances necessary to delineate the electrically classified location created by a specific release point or piece of equipment. General Release Sources A release source is a point or location from which a flammable gas, vapor or liquid may be released into the atmosphere such that an ignitable gas atmosphere could be formed. Given below are designated release sources. For each source, rules are given for determining the extent of the classified location attributable to it. For figures, refer directly to the API RP 505 and NFPA references cited. Where Figure 20, 21 or 22 is referenced in this Standard, the "additional Zone 2 area" is mandatory. 1. For relief valves venting to atmosphere, the classified area shall be determined by: - Figure 20, or Figure 21, when the source is adequately ventilated and the gas/vapor is heavier than air. - Figure 24, when the source is adequately ventilated and the gas/vapor is lighter than air.