How To Deal With Pre-Charge Loss In Bladder Accumulators Due To Gas Permeation

Similar documents
Diaphragm Accumulators

Mining scalers are used in. Designing a stable suspension. F l u i d P o w e r. Demanding application requires unique engineering approach.

Unit 24: Applications of Pneumatics and Hydraulics

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

TECHNICAL DATA. Q = C v P S

A hose layline contains important information for specifying the replacement assembly: manufacturer, hose trade name, working pressure and hose ID.

Hydraulic Reliability & Preventive Maintenance Report

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Membrane modules for nitrogen and oxygen generator systems. Technology Overview ENGINEERING YOUR SUCCESS.

FUNDAMENTAL PRINCIPLES OF SELF-OPERATED PRESSURE REDUCING REGULATORS. John R. Anderson Emerson Process Management Fluid Controls Institute

Hydraulic Piston Accumulators

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

DI-DRO ADVANCED FORMING SYSTEMS

Application and Sizing

TECHNICAL DATA. Q= Cv S

Bladder Accumulators. General Information. Bladder Accumulators. Introduction. Accumulator Function. Why use a Bladder Accumulator?

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

FLOW CONTROL & AIR PILOT SWITCH VALVES

SC HYDRAULIC ENGINEERING CORPORATION

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

Lesson 6: Flow Control Valves

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Superiorities of MTB Breakers

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Copyright, 2005 GPM Hydraulic Consulting, Inc.

BACK PRESSURE / SUSTAINING

Simplicity in VRU by using a Beam Gas Compressor

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

Air Operated Hydraulic Pumping Systems to 50,000 psi

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

TECHNICAL DATA Q= C. Table 1 - Specifications

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

BACK PRESSURE / SUSTAINING

Expansion Tank Design (Chilled Water)

TECHNICAL DATA. Q = C v P S

Compressor Seal Replacement and Upgrades SERVICES

TECHNICAL DATA. Q = C v P S

Smooth Vent Valve XVD. Series

Bladder Accumulators High pressure

KM/31000 (Stainless steel end plates) Air bellows, single acting

Smooth Vent Valve. XVD Series

Porter Analytical & Industrial Products

TECHNICAL DATA. Table 1 - Specifications

Hydraulic Punch Drivers

Industrial Hose Products

North American 7339 High Pressure Gas Regulators

TECHNICAL DATA. Q = C v P S

ACCU-PULSE Installation and Operation Instructions

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

Hydraulic Punch Drivers

09 - Choosing /sizing a cylinder and valve

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

ASX 176 Axial Pressure regulator

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

NOTES ON WATER HAMMER. 55

Allegheny York Co. O-Ring. Kits. Experience Inventory Manufacturing1

NITROGEN PRE-CHARGING INSTRUCTIONS FOR TOBUL ACCUMULATORS

Diaphragm Accumulators

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Target Cleanliness Worksheet. Systemic Contamination Control

High Pressure Equipment Pressure Vessels and Reactors Index

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

PVG 32 Using flow or pressure control spools

Safe hydraulics for hydroforming presses. more finished product to be created from less raw material.

Pilot Check Valve: Metal Body Type

DN300 DN2000 C Plunger Valve

TECHNICAL DATA. Page 1 of 12

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

Technical Tip. LoadAdaptive TM Counterbalance Valves. Introduction. Overview. August 2015

Chapter 10: Bidirectional Flow Controls

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

APPLYING VARIABLE SPEED PRESSURE LIMITING CONTROL DRIVER FIRE PUMPS. SEC Project No

Technical Tip. LoadAdaptive TM Counterbalance Valves. Introduction. Overview. November2015

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Air Eliminators and Combination Air Eliminators Strainers

Basic Hydraulics. Module 4: Flow Control Valves & Pressure Relief Valves. Academic Services PREPARED BY. January 2012

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

Pressure Regulators. Operating Instructions. Instrumentation

Noth American 7347 High Pressure Gas Regulators

Pocket Bellows Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

TEST BENCH FOR SAFETY VALVES

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL B HYDRAULIC HAND PUMP SINGLE STAGE

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

COATINGS SPRAY GUIDE Urethane 520

PRESSURE DIFFERENTIAL PRODUCTS 2008 TRICO CORPORATION. ALL RIGHTS RESERVED.

TECHNICAL DATA OBSOLETE

Transcription:

How To Deal With Pre-Charge Loss In Bladder Accumulators Due To Gas Permeation By Ed Godin, Technical Services Manager, and Dave Broad, Chemist, Parker Hannifin Corporation, Hydraulic Accumulator Division THE ISSUE The trade-off to using low temperature bladder compounds in mobile hydraulic applications is higher gas permeation rates through the bladder at working temperature. INTRODUCTION Hydraulic bladder accumulators are the preferred choice in mobile applications where rapid cycling, high fluid contamination and fast response times are required. Bladder accumulators are used in a wide variety of mobile hydraulic systems to optimize system performance and prolong equipment life by absorbing shock, maintaining system pressure or providing a backup power supply of hydraulic energy. Typical mobile hydraulic applications are listed in Table 1 Mobile Applications For Hydraulic Bladder Accumulators. What most designers don t account for is the inherent loss in pre-charge that occurs over time due to gas permeation through the bladder. Left unchecked, this pre-charge loss leads to poor performance and premature bladder failure. This issue is of most concern in mobile applications where there can be a significant difference in the temperature when the equipment is not in use (-60 to 100 F) and Table 1 Mobile Applications For Hydraulic Bladder Accumulators Brakes (park and service) wheel loaders, backhoes, off-highway vehicles Ride control wheel loaders, backhoes, skid steering Dead engine pilot wheel loaders, backhoes, skid steering Steering off-highway vehicles Hitch cushion bowl scrapers Energy recovery excavators Track take-up steel and rubber tracks on bulldozers and backhoes Pilot lines to supplement pump flow wheel loaders, bulldozers and backhoes Pilot lines to suppress shock wheel loaders, bulldozers and backhoes Suspension systems trucks, sprayers Transmissions to keep brakes/clutch pack release Shock counterbalances combines Shock absorption scraper blades, sprayer arms Content: Gas Permeation In Bladder Accumulators Bladder Accumulators - An Overview...2 Selection Considerations...2 Bladder Compounds For Low Temperature Applications...2 The Gas Permeability Issue Simplified...3 The Gas Permeability Factor...3 Bladder Material Codes...3 Bladder Minimum Temperature Use vs. Permeability Factor Charts...4 Managing Gas Pre-Charge...5 Bladder Life Expectancy...5 Differences In Bladder Compounds/ Manufacture...6 Application-Specific Help...6 1

when it is at working temperature (0 F to 250 ). The key is to fully understand the Permeability Factor of the selected bladder material for low temperatures vs. the potential pre-charge loss due to gas permeation at working temperature. Figure 1 Bladder Accumulator Diagram In that gas permeation cannot be avoided, it needs to be factored into the application specification. And, the pre-charge needs to be routinely checked and maintained throughout the life of the equipment application. BLADDER ACCUMULATORS AN OVERVIEW Hydraulic bladder accumulators consist of a fluid section and a gas section (Figure 1). The flexible rubber bladder acts as a gas-proof screen. The fluid around the bladder is connected with the hydraulic circuit so that the accumulator draws in fluid thus compressing the gas. When the pressure drops, the compressed gas expands and forces the stored fluid into the circuit. A poppet valve, normally held open by spring pressure, prevents the bladder from extruding out of the fluid port. Bladder accumulators provide the following advantages over piston and diaphragm accumulator designs. Specifically they Work better with fluids that have low lubricity, including water Are more contamination tolerant Are lighter in weight Have a very quick response especially at low pressures (under 100 psi) Can be repaired quick and easily should there be a failure SELECTION CONSIDERATIONS There is a range of bladder compounds available that permit accumulator use in temperatures from -60 F to 250 F. Each compound has a specific minimum low temperature limit. Most important, each has a gas pre-charge loss Permeability Factor that can range from minimal to significant depending on the application working temperature. Because of the vast performance differences in bladder compounds, the No. 1 application consideration is the fluid to be used in the system. The No. 2 consideration is the application temperature range. BLADDER COMPOUNDS FOR LOW TEMPERATURE APPLICATIONS Bladder compounds for low temperature applications (-60 F to 0 F) include the following: Min. Temp ( F) Nitrile -10 Nitrile LT -60 Hydrin -40 Buty -40 EPR -40 Fluorocarbon -10 The temperature listed is the lowest temperature in which the compound can be used. 2

Nitrile bladders are considered suitable for most fluid power applications. The other compounds are designed to provide compatibility with a wide range of fluids, working temperatures and gas permeation requirements. To determine which material is appropriate for a given application, always refer to the fluid manufacturer s recommendation. THE GAS PERMEABILITY ISSUE SIMPLIFIED As you gain low temperature capability in a bladder compound, permeability of the bladder increases, and hence greater pre-charge loss due to gas permeation at working temperature. To show the direct correlation, the permeability potential of each bladder compound was tested to define the relationship between bladder compound permeability and temperature. The Gas Permeability Factor was determined by rating the permeability (potential loss of gas pre-charge through the bladder) of each compound on a scale of 0 to 50 at 70 F. The higher the Permeability Factor the faster gas pre-charge would be lost in a lowtemperature application using that bladder compound. Bladder Material Codes for Parker accumulators have been assigned to simplify compound identification in manufacturing and on through packaging, marketing, shipment, and customer use. Specifically: Min. Temp ( F) Factor Permeability Factor Parker Bladder Code Nitrile (NBR) -10 2-1 Nitrile LT (NBR-LT) -60 37-40 Hydrin (ECO) -40 8-4 Butyl (Bu) -40 2-6 EPR -40 50-8 Fluorocarbon (FC) -10 1-28 EPR, for example, has a low temperature limitation of -40 F, but a Permeability Factor of 50. For comparison, a Hydrin bladder would be four times more permeable than that of a Nitrile bladder in the same application. Likewise, an EPR bladder would be 25 times more permeable than a Nitrile bladder. The Permeability Factor increases or decreases with temperature, setting up a trade-off situation for having to use a low temperature bladder compound. If the application requires a -40 F bladder material because the equipment needs to be left out the cold overnight, the upside is that the bladder won t shatter at low temperature. The downside is that the pre-charge in the bladder will have to be checked more often because of the higher working temperature when the oil warms up. 3

BLADDER MINIMUM TEMPERATURE USE VS. PERMEABILITY FACTOR CHARTS The following charts will assist bladder accumulator users when they have a low temperature application. Figure 2 Permeability Factor & Bladder Compounds shows the permeability of each compound on a 0 to 50 Permeability Factor scale. Again, the Permeability Factor was determined by testing each compound at 70 F. Nitrile, Butyl and Fluorocarbon compounds are graphically shown to have relative low Permeability Factors. Nitrile LT and EPR compounds have relatively high Permeability Factors. Figure 3 Minimum Use Temperature & Bladder Compounds shows the lowest temperature in which each bladder compound can be used. Referencing both charts, it is graphically easy to see that the Nitrile LT compound, for example, has excellent low temperature capability at -60 F, but the trade-off for that low temperature performance is a relatively high Permeability Factor of 37. This is a solid confirmation that using this bladder compound will require more frequent maintenance checks for the loss of pre-charge due to gas permeation. Figure 2 Permeability Factor & Bladder Compounds NBR NBR-LT ECO Bu EPR FC Bladder Compound Figure 3 Minimum Use Temperature & Bladder Compounds NBR NBR-LT ECO Bu EPR FC Bladder Compound 4

MANAGING GAS PRE-CHARGE When pre-charge is lost in a bladder accumulator, it changes the available volume in that application. Example: Where emergency power, or the auxiliary power source is supplementing pump flow, or where the accumulator is sized based on how much volume is needed to accomplish the task, too low a pre-charge can have rapid and severe consequences. Specifically, in an emergency situation there would not be enough fluid to complete the cycle, or the cycle would slow down. Should pre-charge continue to be lost, the point is eventually reached where the bladder will be damaged. That point occurs when the maximum ratio exceeds 4 to 1 between the maximum pressure and the pre-charge. If, for example, the maximum pressure is 2,000 psi, the pre-charge should not go below 500 psi. This is the point where damage to the bladder begins. Depending on the application, such a loss of pre-charge could represent a significant safety issue. Emergency power and emergency steering applications are prime safety issue examples. Restated, pre-charge loss is inherent in bladder accumulators that occurs over time due to gas permeation through the bladder. Hence, pre-charge needs to be monitored on a regular basis especially if the chosen bladder compound has a high permeability rate. How long will a pre-charge last in a given application? As previously noted, the life factors are the bladder compound and temperature. Every application presents many variables. For new applications, the recommended pre-charge maintenance protocol is to Check pre-charge once a month for the first six months. If there are no problems Extend the maintenance period to two months. If there are no problems Extend the maintenance period to three months and continue the maintenance extension on a monthly basis until a pre-charge maintenance comfort level is reached for that application. In some applications the working temperatures may be sufficiently moderate that pre-charge only needs to be checked on a yearly basis. The procedure for checking pre-charge is detailed in the supplied Maintenance Bulletin for bladder accumulators. Can a portion of the pre-charge be lost when checking the pre-charge level? Yes, it s possible. Bladder accumulators are available in sizes ranging from 5 cubic inches up to 400 gallons. Hence, the smaller the accumulator, the less amount of gas is in play. For this reason, care must be taken in checking the pre-charge level of smaller accumulators to ensure that the correct amount of pre-charge is always maintained. BLADDER LIFE EXPECTANCY Properly designed and sized for the application, and with pre-charge checked as part of a regular maintenance schedule, the bladder should last for the life of the application. In that bladder accumulators and the bladder compound selected are application-specific, there is no reason to replace a bladder unless it fails. 5

DIFFERENCES IN BLADDER COMPOUNDS/ MANUFACTURE Bladder accumulator manufacturers worldwide have varying approaches to the compound formulations they use and the method of manufacture. Parker s compound expertise has developed specific and proven formulas for all bladder compounds it manufacturers and sells. Parker is also the only company with its own bladder engineering and manufacturing facility. As such, Parker has total quality control of the bladder compound, bladder manufacture, and its incorporation into a fully assembled accumulator. APPLICATION-SPECIFIC HELP With Greer Bladder Products, Parker has over 70 years of experience in formulating bladder compounds and in making the finest, highest quality bladder accumulators. All 70 years of bladder accumulator application experience is available through Parker s worldwide customer service network to make sure that all customers get the right bladder, right bladder size and compound for their application. In addition, the very latest in accumulator sizing technology is available with Parker s inphorm Accumulator Sizing and Selection Software (3.7 is the most current version). The software performs the necessary calculations and eases the process of sorting through catalog drawings, charts and tables. Parker Hannifin Corporation Hydraulic Accumulator Division 10711 N. Second Street Rockford, IL 61115 (815) 636-4104 www.parker.com/accumulator Copyright 2007 Parker Hannifin Corporation All rights reserved. 6