QE-1, Rev Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Similar documents
Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

BPS-2, Rev TABLE OF CONTENTS

SERIES 20 CHAMBERS THE RC-25 AND RC-25F CHAMBERS ASSEMBLY

Vacuum grease can be applied to Warner chambers by use of a syringe or a small artist s dotting brush. Both approaches are described below.

Application of vacuum grease

SERIES 20 CHAMBERS THE RC-26, RC-26P AND RC-26G CHAMBERS ASSEMBLY

THE RC-26GLP CHAMBER RC-26GLP RC-26G

Vacuum grease can be applied to Warner chambers by use of a small artist s dotting brush or a syringe. Both approaches are described below.

SERIES 20 CHAMBERS THE RC-20 AND RC-20H CHAMBER ASSEMBLY

User s Guide. Vacuum Controller for liquid delivery systems

Model # HC-MIS INSTRUCTION MANUAL

INSTRUCTION MANUAL. January 23, 2003, Revision 0

User s Guide. Pressure Controller for liquid delivery systems

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Instructions for use Compressed air injector with water trap

User Manual April 2015

Instruction Manual. Coverslip Clamp Chambers

Flexi-pro Aerosol Delivery System (FADS) Manual

Techcon Systems TS1258 Pressure Pot

Multi-Probe Sampling System User Guide & Manual

INFLATOR TDUX-IT-16 AND GAS CYLINDER E

User s Guide. CO2 Controller for miniature incubators

PH01 Perfusion Cannula Manual

Product Specifications Specialty Junction Boxes

Product Numbers & Ordering Information

GILMONT ACCUCAL FLOWMETERS

Linkam Scientific Instruments USER GUIDE. LTS420 and LTS120. Temperature Controlled Stage

Bull s-eye Levels and Screw-On Levels

Schroeder Check Test Point System

Instruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.

Microscopy Cryogenic WORKSTATION. Performance by Design

tel: fax: web:

High Precision Gauge Pressure Indicators

Model 6812C Dual Lane Scoreboard Owner s Manual

Preferred Instruments Danbury, CT USA

5/16 MAXFLOW SPOUTS 17/64 MAXFLOW SPOUTS. 5/16 black spout with barbs $0.25 $ /64 white spout without barbs. 5/16 white spout without barbs

Extension Platform. Base Platform. Crossover. Exit railing. Exit Railing

PAPR Flow Tester. instructions. part no WARNING

Microprojectile Bombardment Protocol

Linkam Scientific Instruments USER GUIDE DSC600. Temperature Controlled Stage

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Installation, Operating, Inspection and Maintenance Instructions Ladder Climber s Safety System. Warning

OWNER'S MANUAL. Copyright 2003 GAMMA - All Rights Reserved

Harvard Trip Balance BA710. Impact Test Equipment Ltd & User Guide. User Guide

User s Guide. CO2 & O2 Controller for miniature incubators

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats

Linkam Scientific Instruments USER GUIDE

ATEX ATEX

TRAVSMART permanent single-cable horizontal lifeline system

Series 8500 Expansion Compensators. Catalog 674H

ACCU-MIX 1200 / / 26270

Digital readouts for injection pressure, time, and count. Reliable optically encoded circuit for injection time set

Vibration isolation system 1VIS10W. User manual

Techcon Systems TS1254 Pressure Pot

200 STRINGING MACHINE

User Manual MFCS TM -EZ

Model PSI Compressor with 3-Gallon Air Tank 12VDC

RADROVER REAR RACK INSTALLATION MANUAL

602 STRINGING MACHINE OWNER'S MANUAL

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

SIMPLAIR PIPING TOOL. JXT Company

Halsey Taylor Owners Manual STOP!

Model: 5100 OmniSteel Volleyball System

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

INSTRUCTIONS FOR FM4460N SERIES HIGH PRESSURE, METAL TUBE FLOWMETERS

Instructions Manual. Variable area flowmeter 60 M-1. Series. instrumentation for fluids. Technical Data. C-MI-60M1 Rev.: 0 English Version

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

AutoDrill s OUTSTANDING FEATURES

600 / 600FC OWNER'S MANUAL

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

OWNER'S MANUAL. Copyright 1999 ATS - All Rights Reserved

Modular Gas System. Modular Gas Delivery Stick Components for Microelectronics Equipment Gas Boxes

AR STYLE FIREARMS OWNER'S MANUAL: OPERATION, HANDLING, DISASSEMBLY / REASSEMBLY & SAFETY INSTRUCTIONS

SVS MINI 4 LIFT INSTALLATION INSTRUCTIONS (220V)

On-Off Connector Skirt

Cyclops + Cyclops + Written By: John Bamford e3d-online.dozuki.com/ Page 1 of 18

INFUSION SYSTEM (110V) (220V) USER S MANUAL

Flexible Metal Hose Products

PRECISION DISSOLVED OXYGEN MEASUREMENT SYSTEMS

This document to be used with Hurley traditional Davits

807 E. Parkridge Ave. Corona, CA ACCU Fax:

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Model VR6 System. Installation, Operation & Maintenance

Instruction and Practice Manual

Linkam Scientific Instruments USER GUIDE TST350. Temperature Controlled Tensile Stress Testing Stage

User Manual November 2014

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

User Manual. ECC-Opto-Gas. Release Electrochemical test cell EL-CELL GmbH

RK-IR Sample Draw Aspirator Adapter Operator s Manual

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Vibration isolated tables. Individually tailored to your requirements.

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Floor Mount Socket. T: +44 (0) F: +44 (0)

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

X-6 STRINGING MACHINE OWNER'S MANUAL. Issue 1 - May Copyright 2004 GAMMA Sports - All Rights Reserved

Advantage Lockers & Bike

Stainless Steel 142 mm Filter Holder YY

Transcription:

QE-1, Rev. 03.27.03 35 mm Quick Exchange Platform Model QE-1 1125 Dixwell Avenue, Hamden, CT 06514 (800) 599-4203 / (203) 776-0664 (203) 776-1278 - fax

QE-1, Rev. 03.27.03 Table of Contents DESCRIPTION...3 INTRODUCTION...4 SETUP...5 General Comments...5 Assembly...5 With Series 40 Chambers...5 With Glass Bottomed Culture Dishes...6 OPERATION...7 APPENDIX...8 Cleaning/Maintenance...8 Warranty and service...8 Service...8 Warranty...8

QE-1, Rev. 03.27.03 3 The QE-1 35 mm Quick Exchange Platform from Warner Instruments is designed to conveniently provide the rapid replacement of Series 40 chambers and 35 mm culture dishes in the platform base. This versatile system readily accommodates culture dishes from several manufacturers and will adapt to any microscope stage supported by Warner Instruments. Features of the QE-1 include: Open design allows easy access Designed for 35 mm dishes and 40 Series chambers Quick exchange of chamber or 35 mm culture dish Removable perfusion and suction tube holders Adapters for Willco Wells, Corning, and Falcon dishes available Magnetic stainless steel plates allow attachment of magnetic holders THIS EQUIPMENT IS NOT DESIGNED NOR INTENDED FOR USE ON HUMAN SUBJECTS

QE-1, Rev. 03.27.03 4 INTRODUCTION The QE-1 Quick Exchange Platform is a versatile base for Warner s Series 40 chambers as well as many popular 35 mm glass bottom cell culture dishes. The platform is at home on both upright and inverted microscopes and includes adjustable perfusion tubes, quick release clamps and resistive heating elements. The QE-1 base has a 25 mm diameter aperture for inverted microscope objectives and magnetic stainless steel plates along the perimeter of the platform permits the use of Warner s MC-1 Magnetic Clamp Kit (which includes a variety of holding tools). Stage adapters are available for all major microscopes. Removable perfusion and suction tubes allow precise perfusion control in any of the Series 40 imaging chambers or in 35 mm dishes. The tubes feature set-screw locks for horizontal positioning, and adjustable presets on the vertical for setting the bath height. These adjustments facilitate simple and exact repositioning of both the suction and perfusion tubes following chamber exchange. A newly redesigned suction tube eliminates tidal action and fluid flutter in the bath resulting in quite aspiration. Resistive heating of the QE-1 base is provided by Warner s TC-324B or TC-344B Temperature Controller and a CC-28 cable. In-line heating of perfusate can be directly achieved using our SH- 27B or SF-28 In-Line Solution Heaters.

QE-1, Rev. 03.27.03 5 SETUP General Comments The QE-1 platform is designed to accept any of the Series 40 chambers from Warner Instruments, as well as glass bottomed 35 mm culture dishes manufactured by Willco Wells, Corning or Falcon. Series 40 chambers are secured into place by the included retaining clips. Glass bottomed culture dishes can be secured by the use of the supplied QE-1 Clip Hold-downs (4). Optional AR-4 adapter rings may be needed to ensure a close fit between the culture dish and platform base (see page 6). In all cases, solution flow is provided by the adjustable perfusion and suction tubes. The QE-1 comes supplied with removable perfusion tubes and retaining clips. A short length of C-Flex tubing is also included to facilitate the attachment of flow lines. Additional required components not supplied are a Series 40 chamber or 35 mm culture dish, and a temperature controller. In general, a blank chamber or dish is placed into the platform and the position of the perfusion lines adjusted. Then a chamber or dish containing the sample under study is placed into the platform and secured into place. Next, the perfusion tubes are mounted into their respective holders and the heater control lines are attached. Finally, the platform is placed onto the microscope stage and the perfusion solution delivery lines are attached. The assembly is now ready for use. Assembly With Series 40 Chambers Series 40 chambers are ideal inserts for use with the QE-1 and the platform has been optimized for this application. Warner Series 40 chambers come in several designs to accommodate different applications (a representative sampling is shown to the right). 1. Begin by removing any installed chambers from the QE-1 base. Also remove any retaining clips and perfusion tubes. 2. Place a blank Series 40 chamber into the base. 3. Mount the perfusion tubes and make adjustments for positioning and solution height. The perfusion tubes can now be manipulated without affecting their adjustment. 4. Remove the perfusion tubes from the QE-1 base and replace the blank Series 40 chamber with an assembled chamber containing your sample.

QE-1, Rev. 03.27.03 6 5. Secure the chamber into place using the retaining clips. 6. Place the previously adjusted perfusion tubes into position. Attach a small length (approx 1/2 in) of C-Flex tubing to the ends of the perfusion tubes to facilitate coupling of your perfusion flow lines to the perfusion tubes. 7. Attach the CC-28 cable assembly to the QE-1. The blue connectors QE-1 attach to the heating elements and the white thermistor goes into the large hole in the side of the QE-1 (see photo on page 4). 8. Place the QE-1 into an appropriate stage adapter and place the QE-1 onto your microscope stage 9. Insert your perfusion flow lines into the C-Flex tubes attached to the perfusion tubes. 10. The completed assembly is ready for use. With Glass Bottomed Culture Dishes The QE-1 provides an ideal environment for the rapid screening of cell cultures grown in 35 mm culture dishes. Culture dishes from several manufacturers are supported by the QE-1. In general, a culture dish adapter ring must be used to provide a secure, tight fit between the culture dish and the QE-1 platform. Adapter ring sets are not included with the QE-1. Adapter ring color codes Blue Willco Wells: Models D3512 and D3522 Red Falcon: 37 mm Gold Falcon: 38 mm Green Corning: 25000 series 1. Begin by removing any installed chambers from the QE-1 base. Also remove any retaining clips and perfusion tubes. 2. Place a blank 35 mm culture dish with adapter ring into the base. 3. Mount the perfusion tubes and make adjustments for positioning and solution height. The perfusion tubes can now be manipulated without affecting their adjustment. 4. Remove the perfusion tubes from the QE-1 base and replace the blank culture dish with an assembled culture dish (with ring) containing your sample. 5. Place the previously adjusted perfusion tubes into position. Attach a small length (approx 1/2 in) of C-Flex tubing to the ends of the perfusion tubes to facilitate coupling of your perfusion flow lines to the perfusion tubes.

QE-1, Rev. 03.27.03 7 6. Attach the heater control lines to the thermistors on the QE-1 base. 7. Place the QE-1 into an appropriate stage adapter and place the QE-1 onto your microscope stage 8. Insert your perfusion flow lines into the C-Flex tubes attached to the perfusion tubes. 9. The completed assembly is ready for use. OPERATION The open format design of the QE-1 enables easy access for microelectrodes, pipets and perfusion lines. Cell culture dishes and Series 40 chambers can be quickly and easily exchanged without affecting the adjustments of the flow lines. The open design of the QE-1 also permits imaging using either upright or inverted microscopes. Warner Series 20 stage adapters are used to mount the QE-1 onto most commonly used microscope stages. Contact our Tech Support Department for custom stage adapters. Resistive heating of the QE-1 is achieved using Warner s TC-324B or TC-344B Temperature Controller and a CC-28 cable. The two blue CC-28 connectors attach directly to each resistive heating element. Feedback control for the temperature controller is provided via a thermistor (T1) which is inserted into the large hole in the platform base (look under the edge of the stainless steel brackets). We recommend using a drop of mineral oil to insure good thermal contact between the white T1 thermistor and the metal chassis. The CC-28 cable s bath thermistor (i.e. T2) can be placed directly in the bath to determine the solution temperature in the region of interest. Heating of perfusate can be achieved using Warner s SH-27B or SF-28 in-line solution heaters which are also controlled via our temperature controllers.

QE-1, Rev. 03.27.03 8 APPENDIX Cleaning/Maintenance The QE-1 is constructed of anodized aluminum and stainless steel. It can be easily cleaned with common laboratory detergents. We do not recommend the use of solvents such as ethyl alcohol (EtOH) as this will likely dissolve the glue holding the stainless steel plates onto the base. For similar reasons, do not autoclave. Warranty and service Service We recommend that all questions regarding service be referred to our Technical Support Department. Normal business hours are 8:30 AM to 5:00 PM (EST), Monday through Friday. Our offices are located at 1125 Dixwell Avenue, Hamden, CT 06514. We can be reached by phone at (800) 599-4203 or (203) 776-0664. Our fax number is (203) 776-1278. E-mail us at support@warneronline.com or through the web at http://www.warneronline.com/contact.html. Warranty The QE-1 is covered by our Warranty to be free from defects in materials and workmanship for a period of one year from the date of shipment. If a failure occurs within this period, we will either repair or replace the faulty component(s). This warranty does not cover failure or damage caused by physical abuse. In the event that repairs are necessary, shipping charges to the factory are the customer's responsibility. Return charges will be paid by Warner Instruments.