OPERATIONS MANUAL. Ultra Pure Systems HydroTube. Reverse Osmosis/Deionizing water production machines designed for water fed pole window cleaning.

Similar documents
Pure Water Power Purification System 4-Stage RODI Operations Manual

NXT 5 Pure Water System

NXT 4 Pure Water System

Installation and Operating Manual

Vessel Installation and Operating Manual

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

Accu-Tab Systems 1000 Series by Axiall Corporation

Accu-Tab Systems 2000 P Series by Axiall Corporation

Light Commercial Reverse Osmosis System. EE-1000 Manual

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT

accidents which arise due to non-observance of these instructions and the safety information herein.

Accu-Tab PowerBase 3070AT by Axiall Corporation

Owner s Manual AMERICAN. LiquaGen 5 Stage (RO/DI) Aquarium Reef System. YEAR Y 1

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

KJ4000 Operating Instructions & Parts Manual NSN

Installation & Instruction Manual For Portable Series R.O. units:

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

INSTALLATION INSTRUCTION

Installation, Operation and Maintenance Manual

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

1020 Industrial Drive, Orlinda, TN fax

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

Accu-Tab PowerBase 3012AT by Axiall Corporation

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

VERTICAL AIR COMPRESSORS

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

KJ1000 Operating Instructions & Parts Manual NSN

Installation, Operation, and Maintenance Manual

200 PSI COMPRESSORS - MODEL NUMBERS

100C Air Compressor Kit

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

444C DUAL PERFORMANCE VALUE PACK

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

400C & 450C DUAL PERFORMANCE VALUE PACKS

FLUSHMATE FLUSHOMETER - TANK SYSTEM. 501-A Series. Owner s Service Manual. 501-A Series

1020 Industrial Drive, Orlinda, TN fax

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

DRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

2 Gallon Air Compressor

IMPORTANT SAFETY INSTRUCTIONS

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

Budget Range Operators Handbook

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

VERTICAL AIR COMPRESSORS

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Model PSI Compressor with 3-Gallon Air Tank 12VDC

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

MODEL NUMBER: P PORTABLE COMPRESSOR

G7S Hand Pump Owner s Manual

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

PERSONAL AIR BREATHING UNIT

SOTR Special Operations Tactical Respirator

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

PC1131 Electric Air Compressor

Freedom8 ShoeBox Compressor Manual

REVERSE OSMOSIS INSTALLATION Watermark 4 Stage

IonGen. Installation Instructions & Maintenance Owner s Manual. Electronic Clarifier for Ponds and Pondless Waterfall Systems

UltRo Dual Flow Reverse Osmosis Water System

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 3K Puller (M3K-M)

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

ULTRA QUIET & OIL FREE

Cocoa Patio Pond with Lit Spillway

HAS2400 Hepa Air Scrubber

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 6K Puller (M6K-M)

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

PURITY INSTALLATION INSTRUCTIONS MODEL P40

Installation Instructions Air Compressor Part # 2780, 2781

Accu-Tab PowerBase 3140AT by Axiall Corporation

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO:

Interface Devices, Inc. Hydraulic Mini Mule

200L BELT DRIVEN AIR COMPRESSOR

Reverse Osmosis System Installation Guide and Operation Manual.

Transcription:

Ultra Pure Systems HydroTube Reverse Osmosis/Deionizing water production machines designed for water fed pole window cleaning. OPERATIONS MANUAL 3650 Dodd Rd Eagan, MN 55123 651.686.5399 Fax 651.686.5695 800.486.2775 www.ipceagle.com 1. p. 1

System Overview The IPC Eagle HydroTube system was designed to produce pure water for window cleaning by professionals in commercial and residential applications. All system components are industrial grade quality and were selected for their ability to meet the demands for the professional commercial applications. This unique, patent pending system incorporates all of the water treatment components into a single pressure vessel resulting in a light weight, high performance, easy use, compact machine. Water supplied to the unit enters the pressure vessel at the bottom end by the transport wheels. It flows first through a combination sediment/carbon block filter. The sediment filter removes solid particulates down to 5 micron in size. The carbon block absorbs and removes chlorine from the water. It is very important to change this filter as prescribed in this manual. The carbon block will become saturated and the chlorine will pass through it and cause damage to the RO membrane. Next this pretreated water flows directly into the Reverse Osmosis (RO) membrane. RO is more like a separation process than filtration, which traps and collects the targeted material. The water molecules are separated from the water flow and move to the center core tube where they collect. This is called product water. The product water flows directly into a deionizing resin (DI) cartridge and then out the pure water discharge port on the end of the HydroTube by the handle. The RO membrane removes 99% of the Total Dissolved Solids (TDS) from the supply water. The deionizing resin removes the remaining 1% of the TDS. The leftover water now has higher TDS level than when it entered the system and is called concentrate. It exits the membrane, flows around the outside of the DI cartridge and out through the side port marked waste water. There is an automatic flow regulator installed in the waste water outlet fitting which controls the waste water flow rate to maintain the proper balance of the entire system. Concentrate water discharge flow can be directed safely to any landscape vegetation, to a sanitary or storm sewer drain. If the HydroTube system is being used in an area with supply water pressure below 40 psi, a boost pump module is available and can be easily attached to the HydroTube in just a few minutes. The EcoBoost module is electric driven and will provide a 50 psi boost to the supply water pressure. Contact your local distributor for details. 1. p. 2

Unpacking and Initial Setup 1. Unpack the unit from its shipping box and inspect all parts for any damage that may have occurred during shipping. Notify your distributor immediately if there are any damaged or missing components. 2. The pre-filter, RO membrane and DI resin cartridge are already installed inside the HydroTube. 3. Attach the wastewater discharge hose to the wastewater outlet port on the side of the tube near the handle. 4. The HydroTube is now ready for use. 1 Optional TDS Monitor Installation 1. Insert the probe into the side of the discharge fitting on the end of the unit by the handle. 2. Wrap cord around main tube twice. 3. Plug cord into the display monitor. 4 4. Attach display monitor to the metal handle bracket 4 with Velcro. 1. p. 3

Setup 1. Locate supply water connection at job site. 2. Find suitable setup location for HydroTube at the job site. 3. Lay HydroTube down in a horizontal position for maximum stability. 4. Connect a 5/8 inch ID or larger garden hose to the supply water connection fitting. Use of more than 100 ft of garden hose may affect system performance. 5. Connect the male end of the garden hose to the INLET port on the HydroTube. 6. Position the WASTEWATER hose outlet to landscape or other area to accept the concentrate water flow. Additional garden hoses may be added if required to reach designated area. 7. Connect the PURE WATER hose to the fitting on the end, in the center of the cap. 8. Connect the other end of the PURE WATER hose to the water-fed pole hose. A control valve is typically installed between these two hoses for operator control. Supply water inlet Pure water out to pole Operation Waste water outlet 1. Turn water supply valve to its full open position. 2. Verify water flow at the WASTEWATER outlet. 3. Allow PURE WATER to flow from brush for 1 2 minutes. 4. Take a sample of the PURE WATER at the brush and test it with the TDS meter. If water test is higher than 10 ppm, service of HydroTube is required. 5. Wash windows as directed. Adhere to safety precautions for use as recommended by pole manufacturer. 1. p. 4

Shutdown 1. Open PURE WATER valve at pole if installed. 2. Turn water supply valve to its fully closed position. 3. Disconnect water supply hose from HydroTube. 4. Disconnect PURE WATER hose from HydroTube. 5. Disconnect additional hose that may have been attached to the WASTEWATER hose. Do not disconnect the WASTEWATER hose. 6. Stand HydroTube up vertically on a flat, hard surface. 7. Allow water to drain from HydroTube for 3-5 minutes. This will allow the high TDS concentrate water to drain out of the unit, extending the overall life of the RO membrane. 8. Connect the male end of the waste water hose to the INLET port on the HydroTube. This will keep the unit sealed up so residual water will not drain out during transportation. Shutdown & Storage - See Page 6 1. p. 5

RO Protect RO Membrane Protection & Storage Solution A B Open drain/flush valve located at the bottom of the RO pressure vessel. Pour entire package of RO Protect into 1gallon of pure water or distilled water, mix thoroughly ensuring all powder has been dissolved. Note: RV antifreeze (propylene glycol) may be used if freeze protection for system is required. C Hydro Cart & RODI Cart System HydroTube Ultra Pure series Hydro Cart & RODI cart system long term storage instructions System Preparation: 1. Remove sediment filter and carbon filter, empty water. Reinstall empty housings. 2. Open drain/flush valve located at the bottom of the RO pressure vessel. (see fig. A) 3. Remove safety cap on top of RO pressure vessel. 4. Remove DI resin cartridge or DI sock. Reassemble empty DI pressure vessel. 5. Allow DI resin cartridge or sock to drain for an hour. Then wrap it securely in plastic to prevent it from drying out. Store indoors to protect from freezing. 6. Disconnect pure water discharge hose or hose reel. Drain majority of water from hose. RO Protect Solution preparation and application: 1. Pour entire package of RO Protect into 1 gallon of pure water or distilled water, mix thoroughly ensuring all powder has been dissolved. Note: RV antifreeze (propylene glycol) may be used if freeze protection for system is required. (see fig. B) 2. Use waste water hose to connect the inlet and waste outlet creating a closed loop. (see fig. C) 3. Slowly pour solution into the top of the open RO pressure vessel(s). Close drain/flush valve when solution starts coming out, filling pressure vessel(s) to the top. (see fig. D) 4. Allow time for solution to settle into the membrane, top off as needed, reinstall all covers and store. System Restart procedure: 1. Install new carbon and sediment filters. 2. Connect water supply hose to inlet, open drain/flush valve, turn on water (turn on pump motor if applicable). 3. Allow solution to flush for 10 minutes then close flush valve. 4. Allow system to run for 5-10 minutes. Check pure water flow rate and TDS level to ensure system is operating properly. 5. Shut down system. 6. Install DI resin cartridge or sock. 7. System is now ready for use. D Use waste water hose to connect the inlet and waste outlet creating a closed loop. Slowly pour solution into the top of the open RO pressure vessel(s). Close drain/flush valve when solution starts coming out, filling pressure vessel(s) to the top. MSDS - www.ipceagle.com/msds 1. p. 6

Service Carbon/Sediment pre-filter replacement: 1. Replace Carbon/Sediment pre-filter as directed in the Maintenance section of this manual on page 13. 2. Lay HydroTube down horizontally on a hard surface. 3. Remove Snap Ring on the inlet end by the wheels. If snap ring is tight, push plug down (in) to release pressure on snap ring. It should come out easily. 4. Remove Plug. Rock plug back and forth if needed to unseat from o-ring. 5. Remove used filter and discard into the trash. 6. Open new filter package. 7. Remove the 2 rubber gaskets from the ends of the new filter and discard. 8. Apply a thin film of Magic Lube to the inside diameter of both ends of the new filter. Carbon/Sediment Filter Tube Adaptor Snap Ring Plug Plug Adaptor Apply Magic Lube Plug O-Ring 9. Install filter onto Tube Adaptor inside HydroTube. 10. Make sure Plug Adaptor is inserted into Plug. 11. Apply a thin film of Magic Lube on to the large Plug o-ring. 12. Insert Plug o-ring into place in HydroTube housing. 13. Install Plug. Make sure it is fully seated down over the o-ring. 14. Install snap Ring tail end first. It is very important to ensure the snap ring is seated all the way into its groove. 1. p. 7

DI Resin Cartridge Replacement 1. Replace DI Resin Cartridge at the same time along with the Carbon/Sediment filter or if TDS levels on the Pure Water exceeds 1% of the feed water TDS level 2. Stand HydroTube up vertically or lay down on a hard surface. 3. Remove Snap Ring on the Pure Water outlet end by the handle. If snap ring is tight, push Plug down to release pressure on snap ring. It should come out easily. 4. Remove Plug. Rock plug back and forth if needed to unseat from o-ring. 5. Remove used cartridge and discard into the trash. 6. Remove foil tape from the ends of the new cartridge. DI Resin Cartridge Plug O-Ring Plug Snap Ring Apply Magic Lube 7. Apply a thin film of Magic Lube to the outside diameter of the male end of the new cartridge. 8. Install cartridge, female end down onto the membrane permeate tube inside HydroTube. 9. Apply a thin film of Magic Lube on to the large Plug o-ring. 10. Insert Plug o-ring into place in HydroTube housing. 11. Install Plug. Make sure it is fully seated down over the o-ring. 12. Install snap Ring tail end first. It is very important to ensure the snap ring is seated all the way into its groove 1. p. 8

Eco-Boost Module The Eco Boost module is an electrically driven centrifugal pump which will increase the feed water pressure to the HydroTube system by 50 psi. This will increase the Pure Water volume by 60-100%, depending on supply water pressure and temperature. Example: Your tap water supply pressure is 40 psi, when the pump is turned on, the pressure to the RO membrane will be 90 psi. It will also increase the Pure Water pressure to the brush allowing cleaning with the longest poles available. Operational note: With the Eco-Boost module installed and the pump motor turned OFF, the Hydrotube will perform as a non-powered unit. The pump will not interfere with the water flow or pressure from the supply tap. Installation 1. Lay HydroTube down horizontally on a hard surface. 2. Place Eco-Boost module onto HydroTube with the connections facing the wheel end. The end of the curved frame should contact the black end cap on the HydroTube. 3. Remove nut from band clamp. 4. Spread clamp open and place around tube and module frame on the motor end. 5. Squeeze clamp ends together while guiding the bolt into the clamp end. 6. Attach nut finger tight. 7. Repeat steps 3-6 for the pump end. 8. Center module on top and tighten clamp nuts 1. p. 9

Setup Setup Connections 1. Locate supply water connection at job site. 2. Find suitable setup location for Hydrotube at the job site. 3. Lay HydroTube down in a horizontal position for maximum stability. Supply Water Inlet Pure Water out to Pole Wastewater Outlet 4. Connect a 5/8 inch ID or larger garden hose to the supply water connection fitting. Use of more than 100 ft of garden hose may affect system performance. 5. Connect the male end of the garden hose to the INLET port on the Eco-Boost pump. 6. Position the WASTEWATER hose outlet to landscape or other area to accept the concentrate water flow. Additional garden hoses may be added if required to reach designated area. 7. Connect the PURE WATER hose to the fitting on the end by the handle, in the center of the cap. 8. Connect the other end of the PURE WATER hose to the water-fed pole hose. A control valve is typically installed between these two hoses for operator control. Open the control valve fully. WARNING! Hazardous Voltage. Risk of dangerous or fatal electric shock. Plug the pump into a 115 Volt, 60 cycle, ground fault circuit interrupter (GFCI) protected grounded outlet only. This pump is equipped with a 3-wire, grounded, cord and GFCI plug. Make sure the pump circuit meets the National Electrical Code in the USA or the Canadian Electrical Code in Canada. To Avoid dangerous electrical shock hazard, keep the cord dry at all times. 9. Plug GFCI plug into a properly grounded circuit. If an extension cord is required, use this table to size the extension cord. 10. Press the TEST button on the GFCI. The light should go out and you will hear a click. This indicates the GFCI is operational. 11. Press the RESET button on the GFCI. The green light will illuminate and you will hear a click. The unit is ready for operation. Cord Length 0-150 Ft 151-200 Ft 201-350 Ft Cord Wire Size 14 AWG 12 AWG 10 AWG Test Reset Indicator Light 1. p. 10

Operation 1. Turn water supply valve to its full open position. 2. Turn pump power switch to the ON position. 3. Verify water flow at the WASTEWATER outlet. 4. Open PURE WATER at pole. 5. Allow PURE WATER to flow from brush for 1 2 minutes. 6. Take a sample of the PURE WATER at the brush and test it with the TDS meter. If water test is higher than 10 ppm, service of HydroTube is required. 7. Wash windows as directed. Adhere to safety precautions for use as recommended by pole manufacturer. Power Switch Warning! Pump has an autoreset thermal overload protector. If the motor overheats, the overload will cut off the power to prevent damage and will reset after the motor cools. If the overload trips repeatedly, check the pump for the cause. Shutdown 1. Open PURE WATER valve at pole if installed. 2. Turn pump power switch to the OFF position. 3. Turn water supply valve to its fully closed position. 4. Unplug GFCI power cord. 5. Disconnect water supply hose from HydroTube. 6. Disconnect PURE WATER hose from HydroTube. 7. Disconnect additional hose that may have been attached to the WASTEWATER hose. Do not disconnect the WASTEWATER hose. 8. Stand HydroTube up vertically on a flat, hard surface. 9. Allow water to drain from HydroTube for 3-5 minutes. This will allow the high TDS concentrate water to drain out of the unit, extending the overall life of the RO membrane. 10. Connect the male end of the waste water hose to the INLET port on the boost pump. This will keep the unit sealed up so residual water will not drain out during transportation. 1. p. 11

Eco-Boost Pump 5 Exploded View 1 6 3 2 7 4 4 8 Parts List Item Part Number Description Qty 1 BD545165 Pump Motor Asm 1 2 BD545166 GFCI W/35FT Cord 1 3 BD545164 Frame Assembly 1 4 BD545219 BD545167 Band Clamp 2 5 BD545182 Adaptor Fitting 2 6 (Not Shown) BD545187 Gasket for Adaptor Ftg. 2 7 BD545169 Coupler, 3/4 GH 1 8 BD545168 Discharge Hose 1 Electrical Specifications 115 volts AC, 6 amp, 60 Hz, Single phase 1. p. 12

Maintenance Tracking the usage of the HydroTube is critical as it provides the information for replacement of the Carbon Block/Sediment filter. The DI cartridge should be replaced at the same time. Supply water pressure and temperature will affect the production rate (output flow) of Pure Water. Periodically measure this flow rate and use the table below as a guide to indicate when you need to replace the cartridges. Pure Water Flow Rate Change Filters @ Flow Test Procedure Gallons/Minute Ounces/Minute Total Hours 0.4 51 43.9 0.5 64 39.7 0.6 77 36.2 0.7 90 33.3 0.8 102 30.9 0.9 115 28.7 1.0 128 26.9 1.1 141 25.3 1.2 154 23.8 1.3 166 22.5 1.4 179 21.4 1.5 192 20.3 1. Locate a container that will hold 1/2 to 1 gallon. One with volume graduations is preferred or use a measuring cup to measure water collected. 2. Using a stop watch of timer, direct water flow into the container for up to 1 minute. 3. Calculate volume of water by the collection time. Example: Mike collected 36 oz of pure water in 15 seconds. 36 oz X 4 = 144 oz/minute. 144 oz 128 oz/gal = 1.13 gal/min Troubleshooting Low supply water flow or pressure: 1. Eliminate all extension hoses and connect directly to spigot with a single hose. 2. Check for blockage or kinks in hose. 3. Connect to different water source. 4. Replace carbon/sediment filter. High wastewater flow with low Pure Water flow and Good supply pressure: 1. Check waste water flow rate. If more than 0,6 gpm, replace flow regulator 2. Extremely cold water supply. Measure temperature. 3. Plugged membrane Replace membrane High pure water TDS and/or high pure water flow rate: 1. Damaged membrane replace membrane 2. Membrane installed upside down Pump motor does not start: 1. Test and reset GFCI. Green light should be illuminated. 2. Ensure receptacle is energized. 3. Check motor temperature, if hot, allow to cool and restart. 4. Check extension cords. 1. p. 13

1. p. 14

1. p. 15

IPC Eagle Warranty Policy Limited Warranty IPC Eagle warrants new cleaning equipment against defects in material and workmanship under normal use and service to the original purchaser as detailed below. 1 year Subject to the conditions stated below, IPC Eagle warrants all other cleaning equipment components to be free from defects in materials and workmanship for a 1-year period. Parts replaced or repaired are warranted for the remainder of the original warranty period. Batteries are pro-rated for one year. IPC Eagle will furnish and charge for replacement parts, including transportation, to the original owner through an IPC Eagle authorized service center. If the part is returned within 30 days and is found defective, the owner will be credited for the cost of the replacement part including shipping and handling. Wear items exempt from warranty include hoses, fittings, valves, filters and membranes. This warranty shall not apply to failures caused by misuse or abuse, improper maintenance as stated in the operation manuals, use of unauthorized repair parts, repairs by other than an IPC Eagle authorized service center, and damage in transit. IPC Eagle disclaims and denies any liability for any direct, indirect, special incidental or consequential damage which may be suffered as a result of sale, delivery, servicing, use, loss of any product, downtime, labor, freight, or other charges not expressly included herein. Serial Number Purchase Date Purchased From: IPC Eagle Corporation 3650 Dodd Rd, Eagan, MN 55123 651.686.5399 Fax 651.686.5695 800.486.2775 www.ipceagle.com Copyright IPC Eagle 2012 Rev D 5/12 1. p. 16