Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Similar documents
Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Rocker valve. Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 2080 FALTENBALGVENTIL BELLOWS VALVE VANNE A SOUFFLET. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type BBS-03, BBS-05, BBS-06, BBS-25

Type C-CUT. Quickstart. English Deutsch Français

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

Declaration of Conformity as per Directive 97/23/EC

Instruction Manual Contact Pressure Vacuum Gauge

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

4/2 way Pneumatic Solenoid Valve

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Type 2030, 2031, 2031 K, 2032, 2033, 2037

Declaration of Conformity as per Directive 97/23/EC and Manufacturer s Declaration as per Directive 98/37/EC

Dual Solenoid Gas Valve Installation

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22

Safety. Operating instructions Magnetic relief valve VAN DANGER. Contents WARNING CAUTION. Changes to edition 11.11

Solenoid valves VZWF, force pilot operated

OPERATION MANUAL PNEUMATIC VALVES

BGA158 Series CE Approved Class A Shutoff Gas Valve

Instruction Manual Differential Pressure Transmitter

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 03.

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Safety. Operating instructions Bypass/pilot gas valve VBY 8 DANGER. Contents WARNING CAUTION Elster GmbH Edition 01.15

Declaration of Conformity as per Directive 97/23/EC

Instruction Manual Differential Pressure Transmitter

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 06.

BGA158 Series CE Approved Class B Shutoff Gas Valve

Declaration of Conformity as per Directive 97/23/EC

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Pressure relief valve

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Pressure relief valve

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Straight-Way Valve with Packing Gland

SPCH/ Blowing block

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

Instruction Manual Contact Pressure Gauge

GM-7000 Series CE Approved Gas Control Valve

Operating Instructions

Flowmeter. Original operating manual DFM

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. AWA Change-over Valve

Type C-CUT. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Pressure maintenance valve SDV-P / SDV-P-E

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Installation and Operating Instructions Bypass Flow Meter DST

Operating Manual VSA100A. tina29e1 ( )

VR46.5V(A)/VR86.5V(A) SERIES

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

)RU FHUWLILHG FRPSDQLHV ROTEX 509 +HDWLQJ FLUFXLW GLVWULEXWRU 2SHUDWLQJ LQVWUXFWLRQV

Operating Manual * * Pressure Transmitter. Table of Content. 1 Safety Guidelines. 1.3 Risks due to Non-Observance of Safety Instructions

Inverted Bucket Steam Trap IB 16A-7

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Siphon vessel / Priming aid

Type T-CUT. Operating Instructions. Bedienungsanleitung Manuel d utilisation

DK46 - DK800 Supplementary instructions

Mass Flow Controller (MFC) for Gases

Proportional pressure regulators VPPE

Operation Manual Air Saver Unit ASV5000 Series

Operating instructions - Translation of the original -

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

2/2-Way Proportional Valve (motor-driven)

Safety. Operating instructions Filter module VMF Measuring orifice VMO Fine-adjusting valve VMV DANGER. Contents WARNING CAUTION

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Inverse Proportional Pressure-Relief Cart., Size 2 4

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

Operating Instructions

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

2/2-Way Solenoid Control Valve

Proportional Pressure-Relief Cartridge Valve, Size 2...4

3-Way Safety Block DSV

Operating Instructions. ATMOS Chair Comfort. English GA1GB Index 01

Mass Flow Controller (MFC) for Gases

Diaphragm Vacuum Pumps and Compressors

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Operating instructions - Translation of the original -

Proportional Throttle Cartridges, Size 16

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Pull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS

Hafner-Pneumatik presents: General information on ATEX 95 & Products for explosion hazardous environment from the Hafner range

Non-Return Valve SRK 22A

Transcription:

2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques. www.burkert.com 2010-2011 Bürkert Werke GmbH Operating Instructions 1107/04_EU-ml_00805786 / Original DE Operating Instructions Bedienungsanleitung Manuel d utilisation 1. Operating Instructions The operating instructions describe the entire life cycle of the device. Keep these instructions in a location which is easily accessible to every user and make these instructions available to every new owner of the device. The operating instructions contain important safety information! Failure to observe these instructions may result in hazardous situations. The operating instructions must be read and understood. 2. Symbols The following symbols are used in these instructions. Warns of an immediate danger! Failure to observe the warning may result in a fatal or serious injury. Warns of a potentially dangerous situation! Failure to observe the warning may result in a serious or fatal injury. Warns of a possible danger! Failure to observe this warning may result in a medium or minor injury. Note! Warns of damage to property! Important tips and recommendations. designates a procedure which you must carry out. 2 english english 3

3. Authorized Use Incorrect use of the solenoid valve Type 0293 can be dangerous to people, nearby equipment and the environment. The device is designed for dosing, blocking, filling and aerating media. The device is classified in accordance with DIN EN 161 Group 2, Class A for gas. Use according to the permitted data, operating conditions and conditions of use specified in the contract documents and operating instructions. These are described in the chapter entitled Technical Data. The device may be used only in conjunction with thirdparty devices and components recommended and authorised by Bürkert. Correct transportation, correct storage and installation and careful use and maintenance are essential for reliable and problem-free operation. Use the device only as intended. 3.1. Predictable misuse Do not physically stress the device (e.g. by placing objects on it, using it as a screwing aid, standing on it or using it as a lever arm). Do not make any external modifications to the device housings. Do not paint the housing parts or screws. 4 english english 5 4. Basic Safety Instructions These safety instructions do not make allowance for any: Contingencies and events which may arise during the installation, operation and maintenance of the devices. Local safety regulations the operator is responsible for observing these regulations, also with reference to the installation personnel. Risk of injury due to malfunction of valves with alternating current (AC). Sticking core causes coil to overheat, resulting in a malfunction. Monitor process to ensure function is in perfect working order! Danger high pressure! Before loosening the lines and valves, turn off the pressure and vent the lines. Risk of electric shock! Before reaching into the device, switch off the power Risk of burns/risk of fire if used continuously through hot device surface! Keep the device away from highly flammable substances and media and do not touch with bare hands. General hazardous situations. To prevent injury, ensure that: The system cannot be activated unintentionally. Installation and repair work may be carried out by authorized technicians only and with the appropriate tools. After an interruption in the power supply or pneumatic supply, ensure that the process is restarted in a defined or controlled manner. The device may be operated only when in perfect condition and in consideration of the operating instructions. The general rules of technology apply to application planning and operation of the device. 6 english english 7

5. General Information 5.1. Contact address Germany Bürkert Fluid Control Systems Sales Center Christian-Bürkert-Str. 13-17 D-74653 Ingelfingen Tel. + 49 (0) 7940-10 91 111 Fax + 49 (0) 7940-10 91 448 E-mail: info@de.buerkert.com International Contact addresses can be found on the final pages of these operating instructions. And also on the internet at: www.burkert.com 5.2. Warranty The warranty is only valid if the device is used as authorized in accordance with the specified application conditions. 5.3. Information on the Internet The operating instructions and data sheets for Type 0293 can be found on the Internet at: www.burkert.com 6. Technical Data 6.1. Operating conditions Permitted medium and ambient temperature: -15... +60 C Max. operating pressure: 0.15 bar Permitted media depending on seal material: Seal material Permitted media NBR Valve group 2, Class A: Fuel gases of the 1st, 2nd and 3rd gas family. Protection class: IP65 in accordance with device socket 6.2. Conformity The device conforms to the EC directives according to the EC Declaration of Conformity. 6.3. Standards The conformity with EC guidelines is guaranteed in accordance with standards: EN 61010-1, EN 50178, EN 60664-1, EN 60204-1, EN 161 8 english english 9 6.4. Dirt trap The necessary dirt trap is integrated into the valve. 6.7. Rating plate 6.5. Mechanical Data Dimensions Body material Sealing material 6.6. Fluidic Data Circuit functions A (NC) Pressure range A P see data sheet Brass NBR 2/2-way valve, directacting, normal output A unloaded according to the design (see rating plate) Note the voltage and current type as specified on the rating plate. Orifice Operating principle Type Made in Germany Id.- Number 0293 A 25,0 NBR MS Rp1 P N 0-0.15 bar ~230 V 50 Hz 32 VA CE - 0085AS0390 IP65 KL: A GR: 2-15 C +60 C 00189398 W15 ML EC Examination Certificate, Protection class, Classification, Temperature range Voltage, Frequency, Power consumption Port connection, Nominal pressure Seal material Housing material 10 english english 11

6.8. Electrical Data Connections DIN EN 175301-803 Form A for device socket Type 2508 Power supply 220-230 V / 50 Hz 220 V UC / 0-60 Hz Voltage tolerance ± 10 % Nominal operating mode long-term operation, ED 100 % Note the voltage and current type as specified on the rating plate. 7. Installation 7.1. Safety instructions Risk of injury from high pressure in the equipment! Before loosening the lines and valves, turn off the pressure and vent the lines. Risk of injury due to electrical shock! Before reaching into the system, switch off the power Risk of injury from improper installation! Installation may be carried out by authorized technicians only and with the appropriate tools! Risk of injury from unintentional activation of the system and an uncontrolled restart! Secure system from unintentional activation. Following installation, ensure a controlled restart. 12 english english 13 7.2. Fluid installation Risk of injury from high pressure in the equipment! Before loosening the lines and valves, turn off the pressure and vent the lines. Installation position: Installation can be in any position. Preferably: Actuator upright. Procedure: Before installation, clean any possible dirt off the pipelines. Risk of short-circuit or escape of media through leaking screw joints! Ensure seals are seated correctly! Carefully screw together coil and device socket or valve and pipelines! Fig. 1: Identification for flow direction Housing with identification of flow direction Seal the pipe connection with PTFE tape. Note! The PTFE tape must not get into the device. Caution risk of breakage! Do not use the coil as a lever arm. Hold the device with a suitable tool (Open-end wrench) on the housing and screw into the pipeline. Observe direction of flow of the valve (Fig. 1): 1 2 (P A). 14 english english 15

7.3. Electrical installation Risk of injury due to electrical shock! Before reaching into the system, switch off the power Danger of electrical shock if the protective conductor contact between the coil and housing is missing! Always connect protective conductor. Check electrical continuity between coil and housing. Risk of short-circuit or escape of media through leaking screw joints. Ensure seals are seated correctly! Carefully screw together coil and device socket or valve and pipelines! max. 1 Nm Coil Seal (make certain the position is correct!) Device socket Risk of injury due to malfunction of valves with alternating current (AC). Sticking core causes coil to overheat, resulting in a malfunction. Monitor process to ensure function is in perfect working order! Fig. 2: Electrical installation Note the voltage and current type as specified on the rating plate. 16 english english 17 8. Maintenance, Troubleshooting 8.1. Safety Instructions DANGER! Risk of injury from high pressure in the equipment! Before loosening the lines and valves, turn off the pressure and vent the lines. Risk of injury due to electrical shock! Before reaching into the system, switch off the power Risk of injury from improper maintenance! Maintenance may be carried out by authorized technicians only and with the appropriate tools! Risk of injury from unintentional activation of the system and an uncontrolled restart! Secure system from unintentional activation. Following maintenance, ensure a controlled restart. 8.2. Malfunctions Malfunctions If malfunctions occur, check whether: the device has been installed according to the instructions, the connections are correct, the device is not damaged, all screws have been tightened, the voltage and pressure have been switched on, the pipelines are clean. If the magnet does not pick up, ensure that: there is no short-circuit or coil interruption, the core / core area is not dirty. If the valve still does not switch, please contact your Bürkert Service. 18 english english 19

9. Spare parts Risk of injury and/or damage by the use of incorrect parts! Incorrect accessories and unsuitable spare parts may cause injuries and damage the device and the surrounding area. Use only original accessories and original spare parts from Bürkert. 9.1. Spare part sets When ordering replacement parts and replacement part sets, please specify: Order the coil by quoting the identification number of the device, Wearing parts sets SET 3, seal sets SET 2 and housing. Seal set SET 2 Coil Wear parts set SET 3 Housing Fig. 3: Overview of replacement spare parts 20 english english 21 10. Transport, Storage, Disposal Note! Transport damages! Inadequately protected equipment may be damaged during transport. During transportation protect the device against wet and dirt in shock-resistant packaging. Avoid exceeding or dropping below the allowable storage temperature. Incorrect storage may damage the device. Store the device in a dry and dust-free location! Storage temperature: -40... +55 C. Damage to the environment caused by device components contaminated with media. Observe applicable regulations on disposal and the environment. Dispose of the device and packaging in an environmentally friendly manner. 22 english