Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves

Similar documents
Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

Fisher DVI Desuperheater Venturi Inline

Fisher and Whisper Disk Diffusers

Design DSA Steam-Atomized Desuperheater

Fisher 2625 and 2625NS Volume Boosters

Fisher DSA Steam-Atomized Desuperheater

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Fisher 8532 High-Performance Butterfly Valve

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

1305 Series Pressure Reducing Regulators

Types S100K and S102K Pressure Regulators

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

DelVal Flow Controls Private limited

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

64 Series Pressure Reducing Regulators

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

1805 Series Relief Valves

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Fisher L2sj Low Emission Liquid Level Controller

Fisher 4660 High-Low Pressure Pilot

T208VR Series Tank Blanketing Vacuum Regulator

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

MEGR-1627 Instruction Manual

Type 4660 High-Low Pressure Pilot

English. Safety Instructions Form /2007 WARNING. All Products. How to Get Safe-Use Guides. Inspection and Maintenance Schedules

4194 Series Differential Pressure Indicating Controllers

Type FEQ Slam-Shut Valve

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

SIL Safety Manual for Fisherr ED, ES, ET, EZ, HP, or HPA Valves with 657 / 667 Actuator

Safety manual for Fisher GX Control Valve and Actuator

Types 749B and R130 Changeover Manifolds

RB Series Regulating System

Fisher FIELDVUE DVC6200f Digital Valve Controller PST Calibration and Testing using ValveLink Software

Type R622 Pressure Reducing Regulator

Type CT88 Backpressure Regulator

Fisher 4194 Differential Pressure Indicating Controllers

OPERATING AND MAINTENANCE MANUAL

Type EZH Relief or Backpressure Regulator

Pressure Dump Valve Service Kit for Series 2300 Units

SLAM-SHUT VALVE. Type OSE CONTENTS INTRODUCTION CHARACTERISTICS. Scope of Manual. Material. Product Description. Connections

1301 Series High-Pressure Regulators

Type ACE95jr Tank Blanketing Valve

SECTION BUTTERFLY VALVES

Types 95L and 95H Pressure Regulators

Float Operated Level Controllers

1805 Series Relief Valves

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

Installation, Operation & Maintenance Manual

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

BUTTERFLY VALVES Series 800

WHEATLEY Series 500 Swing Check Valve

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

Booster Pump PB4-60 Replacement Kits

WKM Model 320F Floating Ball Valve

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Yoke Block Instruction Manual

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

FLANGED TWO-PIECE BALL VALVES

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

RS(H)20, 25 USER MANUAL

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

Fisher 4194H Differential Pressure Indicating Controllers

S300 Series. Valve Link. Features. Fisher Controls

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

U.S. Patent No. 7,922,246. Patents Pending

Operating instruction

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Installation, operation & maintenance manual - original version

Installation, Operation, and Maintenance Manual

627 Series Pressure Reducing Regulators

Engineering Data Sheet

Quick Start Guide LIQ-QSG-499ACL-03, Rev I July Rosemount 499ACL-03. Monochloramine Sensor

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Mate ULTRA IMT Multi Tool Assembly Tooling Installation Instructions

Only. Gives You the TechLock. System Advantage ASSEMBLY, DISASSEMBLY AND TROUBLESHOOTING INSTRUCTIONS FOR 3000 SERIES FONTAINE

Type ACE97 Pad-Depad Valve

FLANGED MULTI-PORT BALL VALVES

BETTIS RPE Series Rack and Pinion Pneumatic Actuators. Safety Guide DOC.SG.BRPE.EN Rev. 1 November 2015

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Sempell High Pressure Forged Check Valves Forged steel, swing check and tilting disc configuration

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

Installation Instructions, Pressure Regulator Series

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below.

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Transcription:

Instruction Manual D103319X012 Lever-Lock Handlever Actuator Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves Contents Introduction................................. 1 Scope of Manual......................... 1 Description.............................. 1 Specifications............................ 2 Installation.................................. 3 Ordering Replacements...................... 5 Introduction Scope of Manual This instruction manual includes installation, maintenance, and parts information for the Fisher Lever-Lock handlever actuator (figure 1). Refer to separate instruction manuals for information covering the control valves. Do not install, operate, or maintain a Lever-Lock actuator without being fully trained and qualified in valve, actuator, and accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is important to carefully read, understand, and follow all the contents of this manual, including all safety cautions and warnings. If you have any questions about these instructions, contact your Emerson Process Management sales office before proceeding. Description The Lever-Lock handlever is used for reliable manual operation of DN 50 through 150 (NPS 2 through 6) Fisher A81 high-performance butterfly valves. Spring-loading secures the handlever in the notched quadrant plate (figure 2), allowing the valve disk to be locked in intermediate positions. Additionally, the handlever can be locked with a user-supplied padlock with 4.8 to 5.2 mm (3/16 to 13/64 inch) shackle to prevent accidental or unauthorized adjustment (see figures 3 and 4). W9585 Figure 1. Fisher Lever-Lock Handlever Actuator Mounted on Valve www.fisher.com

Lever-Lock Handlever Actuator Instruction Manual Table 1. Specifications Lever-Lock Handlever Actuator Sizes See table 2 Valve Compatibility Mounts on A81 valves per table 2 Maximum torque Output See table 3 Handlever Length Maximum of 432 mm (17 inches). See figure 2 and table 4 Construction Materials Handle, quadrant plate, lever, and mounting bracket are all steel materials. Spring, set screws, and fasteners are stainless steel Dimension and Approximate Weights See figure 2 and table 4 1. The pressure/temperature limits in this manual, and any applicable code or standard limitation, should not be exceeded. HANDLEVER ACTUATOR SIZE I II Table 2. Fisher A81 Valve / Lever-Lock Handlever Compatibility VALVE SIZE SHAFT SIZE SQUARE SIZE DN NPS mm Inches mm 50 2 12.7 1/2 9 80 3 15.9 5/8 11 100 4 19.1 3/4 14 150 6 25.4 1 17 VALVE DISK POSITION 0 Degrees (Breakout Torque) All Other Angles (Dynamic Torque) Table 3. Maximum Allowable Torques and Handlever Force Requirements MAXIMUM TORQUE Size I Size II HANDLEVER FORCE REQUIRED N m In Lb N m In Lb N Lbf 119 1050 164 1450 423 95 47 420 70 620 178 40 2

Instruction Manual Installation The Lever-Lock handlever actuator is normally shipped mounted on the valve at the factory. If the handlever was ordered separately, install the handlever on the valve by following the instructions in this section. WARNING Sudden or unexpected movement of the handle can result from unbalanced flow forces. Firmly grip the handlever and ensure stable footing when operating the handlever to avoid personal injury or property damage. Installing the Handlever Orientation Mount the Lever-Lock bracket assembly, less the handle, to the valve body. The handle is perpendicular to the pipeline when the valve is in the shut position. Rotation of the lever/valve shaft in the counter-clockwise direction will open the valve. Attach the Lever-Lock Handlever actuator to the valve in this orientation but do not fully tighten Lever-Lock Handlever Actuator (torque) the bracket to valve bolting until after the zeroing process below. Handle assembly Place the handle and lever assembly on the valve shaft with the valve closed. Squeeze the lever to compress the spring, position the lever over the notch indicating the closed position, and slide the square cutout portion of the handle over the valve shaft as far as it will go. Maintain at least a 0.8 mm (1/32 inch) gap between the handle and the plate, so the handle doesn t rub on the plate during operation. Torque the two hex socket set screws against the shaft to 2.7 N m (24 in lbf). Zeroing After tightening the set screws, check the orientation of the disk relative to the body seal retainer. Place a straight edge on the seal retainer which spans the valve opening. Visually check to ensure there is equal space (within 0.8 mm [1/32 inch]) between this straight edge and the top and bottom of the disk to ensure the valve is fully engaged in the seal. To adjust this position, rotate the bracket within the clearance of the mounting bolt holes between the valve body and bracket. Once there is equal distance between the disk and the straight edge, tighten the mounting bolts to 115 N m (88 ft lbf). After tightening, recheck disk position at shutoff to ensure nothing shifted during the tightening process. OPEN" MARK ON HANDLE CLOSED" MARK W9583 OPEN" MARK Figure 2. Fisher Lever-Lock Handlever Actuator for A81 Valve (Open/Closed Marks) 3

Lever-Lock Handlever Actuator Maintenance Handlever parts are subject to normal wear/corrosion and must be inspected and replaced when necessary. The frequency of inspection and replacement depends on the severity of service conditions. WARNING Avoid personal injury or damage to property from sudden release of pressure or uncontrolled process fluid. Before starting disassembly: НDo not remove the actuator from the valve while the valve is still pressurized. НAlways wear protective gloves, clothing, and eyewear when performing any maintenance operations to avoid personal injury. Instruction Manual НUse bypass valves or completely shut off the process to isolate the valve from process pressure. Relieve process pressure on both sides of the valve. Drain the process media from either side of the valve. НUse lock-out procedures to be sure that the above measures stay in effect while you work on the equipment. НThe valve packing box may contain process fluids that are pressurized, even when the valve has been removed from the pipeline. Process fluids may spray out under pressure when removing the packing hardware or packing rings, or when loosening the packing box pipe plug. НCheck with your process or safety engineer for any additional measures that must be taken to protect against process media. GG00568_DIS_1 LOCATION FOR USER-SUPPLIED PADLOCK WITH 4.8 to 5.2mm (3/16 to 13/64 INCH) SHACKLE Figure 3. Fisher Lever-Lock Handlever Actuator for A81 Valve (Showing Padlock Location) 4

Instruction Manual Ordering Replacements When corresponding with your Emerson Process Management sales office about this equipment, always mention the valve serial number. It is recommended that complete assemblies are considered for replacements to ensure the latest version of the product is supplied. WARNING Use only genuine Fisher replacement parts. Components that are not supplied by Emerson Process Management should not, under any Lever-Lock Handlever Actuator circumstances, be used in any Fisher valve, because they may void your warranty, might adversely affect the performance of the valve, and could cause personal injury and property damage. Note Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use, or maintenance of any product. Responsibility for the selection, use, and maintenance of any product remains with the purchaser and end-user. 5

Lever-Lock Handlever Actuator Instruction Manual HANDLE SET SCREWS PLATE SPRING LEVER BRACKET VALVE GG03237_1 Figure 4. Fisher Lever-Lock Handlever Actuator for A81 Valve (fully closed valve position shown) Table 4. Dimensions and Weights VALVE SIZE M L WEIGHT DN NPS mm Inch mm Inch kg lbs 50 2 315 12.4 85 3.35 2.72 3 80 3 315 12.4 85 3.35 2.72 3 100 4 432 17.0 103 4.06 3.63 4 150 6 432 17.0 103 4.06 3.63 4 6

Instruction Manual Lever-Lock Handlever Actuator 7

Lever-Lock Handlever Actuator Instruction Manual Fisher and POSI-SEAL are marks owned by one of the companies in the Emerson Process Management business division of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. This product may be covered by pending patents. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end-user. Emerson Process Management Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Chatham, Kent ME4 4QZ UK Dubai, United Arab Emirates Singapore 128461 Singapore www.fisher.com Fisher 8 Controls International LLC 2009; All Rights Reserved