Technote. Frese PVS - Dynamic Pressure and Flow Regulation Valve. Application. Features. Benefits.

Similar documents
Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits.

Technote. Frese ALPHA cartridges. Application. Features. Benefits.

Ballorex Dynamic Description. Versions. Benefits. Balancing

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

STAP. Differential pressure controller DN 15-50

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

STA. Double regulating valves DN 15-50

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

STA. Double regulating valves DN 15-50

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)

PVM 15-50, differential pressure valves

STAP. Differential pressure controller DN

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

TRV-2, TRV-2S. Thermostatic radiator valves With presetting

Presetting Valve Type RA-N with Flange Connection

STAP. Differential pressure controllers DN , ANSI fl anges

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

STAP. Differential pressure controllers DN , ANSI flanges

AVP-F. p setting range (bar) Code No. 003H6200

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

STAD. Balancing valves DN (MD60, MD61, MD62)

AVPQ/AVPQ-F, PN 16. Application

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

STAD-C. Balancing valves DN 15-50

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

Automatic balancing valves ASV

Differential Pressure Control Valve. Passim

Upgradable balancing valves USV

STAD. Balancing valves DN 15-50

Differential pressure controller with flow limitation (PN 16, 25, 40) AFPB / VFQ 2(1) AFPB-F / VFQ 2(1)

TA-H.U.B. Centralised balancing and control ENGINEERING ADVANTAGE

Automatic balancing valves

Seated valve for steam (PN 25) VFS 2 2-way valve, flange

Automatic balancing valves ASV

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

Balancing Valves. Applications/ Features: Ordering Information: Accessories:

STAG. Balancing valves Balancing valve with grooved ends DN

TA-FUSION-P. NPT threads / ANSI flanges

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Overview of types. Technical data. Safety notes

STAD-C. Balancing valve ENGINEERING ADVANTAGE

Seated valve for steam (PN 25)

Chrome plated radiator valves type RA-NCX and lockshield valves type RLV-CX

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

Two-port valves, male threaded, PN25

Pressure Independent Control Series

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet

Seated valves VRB 3, VRG 3

HERZ-Motorised flow controler

V311. Venta. Three-way Plug Valve, Flanged PN 16

Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass

Pressure balanced valves (PN 25)

STAD Series. Balancing and control valves. Technical Data Sheet. WattsIndustries.com

Overview of types. Technical data

Automatic balancing valves ASV

2-port seat valves PN25 with externally threaded connections

STV / STVL. Danfoss STV series of balancing valves provide testing and balancing of circuit flow for hydronic heating or cooling systems.

Pressure reduction controller (PN 16, 25, 40)

Rotary valves HRB 3, HRB 4

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

differential pressure regulating valve - threaded

HERZ - Compact Flow Controller with

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

Type overview. R B2 en-gb subject to changes 1

RA-N radiator valves with integrated presetting and self-sealing tailpiece

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

CALEFFI. Ball zone valves. series /03 GB

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

HERZ - Compact Flow Controller with

Radiator valves VDN2.. VEN2.. VUN2..

Pressure Reducing Valve DMV 755

Differential Pressure Control Valve (DPCV)

Products no longer available

Floor heating. Floor heating manifolds Distributors

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

By-pass valves Series 466 Thermatic - Series USVR

BALANCING VALVES. Total control inside buildings. Flowmaster TM Flowmaster FC TM Deltamatic TM Deltaflow TM ICV - A MEMBER OF THE AVK GROUP

VZL valve - 2/3/4-way

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Cim 787 Variable orifice balancing valve

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

DIFFERENTIAL PRESSURE REGULATING VALVE

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

DIFFERENTIAL PRESSURE REGULATING VALVE zcon

STAD BALANCING VALVES

3-way control valves VK 3

2-Port Seat Valves with Flange, PN 16

Installation, commissioning and servicing instructions

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

GUMMIKOMPENSATOR GKF8000 / GKF8130

Tempering valve for solar and instantaneous applications Installation, commissioning and servicing instructions 2522HP series

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS

Radiator valves VDN1.. VEN1..

Transcription:

Page 1 of 15 - Dynamic Pressure and Regulation Valve Application system can be installed in domestic and commercial heating and cooling systems. system is a dynamic valve arrangement designed to regulate flow and differential pressure using the Frese S dynamic balancing valve positioned in the flow, and the Frese PV differential pressure control valve positioned in the return. The PVS is supplied with capillary tube, isolation valves, drain valves, P/T plugs and unions as standard. system ensures 1% flow and differential pressure regulation under all conditions, irrespective of any changes within the system, providing simple and trouble free commissioning. The system operates by limiting the flow in the system and eliminating any noise caused by excess differential pressure. Benefits Features and differential pressure can be adjusted independently of each other. Setting the differential pressure can be easily adjusted after installation. Size range: DN15 to DN5 Maximum flow: 1.3m 3 /h Maximum differential pressure 25kPa/4kPa Tamperproof presetting device fitted on the top of the valve. Simple presetting of flow and pressure. Setting range: 5kPa to kpa Differential pressure regulation, flow regulation, isolation, drain and PT plugs as standard No additional commissioning required if the system design is changed. High levels of comfort and energy savings for the end user. UK DEC. 9

Page 2 of 15 - Dynamic Pressure and Regulation Valve Design Simplified outline Frese S Adjustable Dynamic Balancing Valve System Frese PV Adjustable Differential Pressure Control Valve Return system measurement of differential pressure and flow across the valve Frese S Design flow: Q is adjusted directly on Frese S (see graphs on the diagram) Differential pressure : ΔP S is adjusted directly on Frese PV (see graphs on the diagram) Return Frese PV P F- The flow in the system is verified by measuring minimum differential pressure (min. Δp) is avaliable across the Frese S valve. Measured from P F+ to P F- (see graphs on the Preset diagram) P F+ Δp of the system is measured from P F- to P +. P + UK DEC. 9 P -

Page 3 of 15 - Dynamic Pressure and Regulation Valve Technical data Housing: DP controller: setting: Spring: Diaghragm: O-rings: Pressure class: Max. differential pressure: Temperature range: Capillary tube: DZR, Brass CW62N PPS 4% glass PPO Stainless steel HNBR EPDM PN16 LP = 25 kpa HP = 4 kpa -1 C to + 12 C Ø3, L = 1mm L1 H2 Return H1 H3 H L Type Application Two-pipe system UK DEC. 9 Dimension DN15 DN2 DN25 DN32 DN4 DN5 Version LP HP LP HP LP HP HP HP HP Control range [kpa] 5-3 2-6 5-3 2-6 5-3 2-6 2-2- 2- Pressure range [kpa] 9-25 22-4 9-25 22-4 12-25 22-4 3-4 45-4 54-4 PV,14-,167,2-,333,2-,27,42-,556,167-,694,194-1,167,27-1,39,33-2,222 1,39-4,167 rate [l/s] S,7-,223,11-,36,11-,351,1-,512,17-,462,25-,653,6-1,32,49-2,67,122-2,6 PVS,14-,167,2-,36,2-,27,42-,512,167-,462,194-,653,27-1,32,33-2,67 1,39-2,6 Dimension mm L 167 173 232 235 257 26 H 127 13 166 166 14 196 H1 7 73 91 91 97 16 L1 167 173 22 235 257 26 H2 96 9 12 115 119 126 H3 14 151 155 1 26 219

Page 4 of 15 - Dynamic Pressure and Regulation Valve Product programme PVS with 2 isolation valves, 2 drain valves, P/T plugs, capillary tube and union connections. Dimension DN15 DN2 DN25 DN32 DN4 DN5 - LP 53-34 Frese PV, 5-3 kpa & Frese S, LP - HP 53-326 Frese PV, 2-6 kpa & Frese S, HP - LP 53-341 Frese PV, 5-3 kpa & Frese S, LP - HP 53-327 Frese PV, 2-6 kpa & Frese S, HP - LP 53-342 Frese PV, 5-3 kpa & Frese S, LP - HP 53-32 Frese PV, 2-6 kpa & Frese S,HP HP 53-323 Frese PV, 2- kpa & Frese S, HP HP 53-324 Frese PV, 2- kpa & Frese S, HP HP 53-325 Frese PV, 2- kpa & Frese S, HP Accessories Frese no. Dim./DN Insulation jackets PV+S PV+S 3-45 15/2/25 3-54 32/4/5 Spindle extension 46-172 46-173 46-174 46-175 Example 15/2 25 32/4 5 Please note: As the flow is reduced in the circuit in question the pressure increases in reverse ratio to the flow, which is due to the P-band of the adjustment spring. The valve still compensates for this. Frese S Frese PV However, the pressure will nowhere in the circuit be as high as the pump pressure that would have been available if Frese PV had not been installed. In this example the pressure increases to approx. 14 kpa as the graph is offset parallel to the course of flow. Furthermore, you can always read from the graph what the pressure in the circuit will be like at any flow rate below the rated 5 l/h. L/s L/h,167 6,139 5,111 4,3 3 5 kpa 1 kpa rate graph - Frese PV DN15 15 kpa ΔPs 2 kpa Pp = Pump pressure Ps = Differential pressure Pv = Pressure loss across valve 25 kpa Frese PV kpa 3 kpa 2, 1,9 1,2,7,56 2,3 UK DEC. 9,2 1,1, 2 3 4 5 6 7 9 1 11 12 13 14 15 16 17 Setting [ Numbers of turns]

Page 5 of 15 - Dynamic Pressure and Regulation Valve Example DN15 Low Pressure Design differential pressure 12 kpa Design flow,139 l/s Differential pressure setting Frese PV 1. The design flow is used as the point of reference for the setting. (See the graph) 2. In order to make reading easier the graphs indicating the pressure in the circuit are arranged at intervals of 5 kpa. Still, the graphs can be offset according to the specified pressure of 12 kpa in our circuit. From the intersection of the 12 kpa graph and the horizontal line indicating,139 l/s a line perpendicular to the x-axis is made to read the pre-set value. app. 7 turns on the scale. 3. The minimum pressure drop required will be 1.9 kpa across the valve. (ΔP V2 ) L/s L/h,167 6,139,111,3,56,2 1 5 4 3 2 1 5 kpa 1 kpa Frese PV DN15 5-3 kpa 12 kpa 2 15 kpa 2,, 2 3 4 5 6 7 9 1 11 12 13 14 15 16 17 2 kpa 25 kpa 3 kpa 1,9 1,2,7,3,1 3 setting Frese S 1. The design flow is used as the point of reference for the setting. (See the graph) 2. The pre-setting for the valve is found by means of the flow rate graph. Setting = 6.7 3. The minimum pressure drop required will be 11 kpa across the valve. (ΔP V1 ) Frese S DN15 Low Pressure (l/s) (l/h) kv (m 3 /h) min. Δp kpa,1,222,3,6, 1,1 1,3 1,6 1, 2,1 2,2 12,,194,167 7 6 12,2 11,6,139 5 11 1 3,111 4 1,4,3 3 9,,56 2 9,2 Total pump pressure Calculation of the total pump pressure: Pp = Ps + ( P V1+V2 ) Pp = 12 kpa + (11 kpa + 1,9 kpa) = 24,9 kpa,2 1 1 2 3 4 5 6 7 9 1 2,6 UK DEC. 9

Page 6 of 15 DN15 LP - Dynamic Pressure and Regulation Valve L/s L/h,167 6 Frese PV DN15 5-3 kpa ΔPs 2,,139 5 1,9,111 4 5 kpa 1 kpa 15 kpa 2 kpa 25 kpa 3 kpa 1,2,3 3,7,56 2,3,2 1,1, 2 3 4 5 6 7 9 1 11 12 13 14 15 16 17 (l/s) (l/h),222 Frese S DN15 Low Pressure Kvs (m 3 /h) min. Δp kpa,1,3,6, 1,1 1,3 1,6 1, 2,1 2,2 12,,194 7 12,2,167 6 11,6,139 5 11,111 4 1,4,3 3 9,,56 2 9,2,2 1,6 UK DEC. 9 1 2 3 4 5 6 7 9 1

Page 7 of 15 DN15 HP - Dynamic Pressure and Regulation Valve Frese PV DN15 2-6 kpa L/s,333 L/h 12 11,1,27 1 7,7,222 2 kpa 3 kpa 4 kpa 5 kpa 6 kpa 4,9,167 6 2,,111 4 1,2,56 2,3, 2 3 4 5 6 7 9 1 11 12 13 14 15 16 Frese S DN15 High Pressure kv (m 3 /h),1,3,6, 1,1 1,3 1,6 1,9 2,2 2,4 Δp kpa UK DEC. 9

Page of 15 DN2 LP - Dynamic Pressure and Regulation Valve L/s L/h,27 1 Frese PV DN2 5-3 kpa ΔPs 6,3,25 9 5,1,222 4,,194,167 7 6 5 kpa 1 kpa 15 kpa 2 kpa 25 kpa 3 kpa 3,1 2,3,139 5 1,6,111 4 1,,3 3,6,56 2,3,2 1,1 2 3 4 5 6 7 9 1 11 12 13 14 15 16 17, 1 (l/s) (l/h),361 13 Frese S DN2 Low Pressure Kvs (m 3 /h) min. Δp kpa,2,5,9 1,4 1, 2,2 2,5 2,9 3,2 3,3 15,333,36,27,25,222,194,167,139,111,3,56,2 12 11 1 9 7 6 5 4 3 2 1 14,5 14 13,5 13 12,5 12 11,5 11 1,5 1 9,5 9 UK DEC. 9,5 1 2 3 4 5 6 7 9 1

Page 9 of 15 DN2 HP - Dynamic Pressure and Regulation Valve Frese PV DN2 2-6 kpa L/s,556 L/h 2 25,,5 1 2,3,444 16 16,,39,333 14 12 2 kpa 3 kpa 4 kpa 5 kpa 6 kpa 12,3 9,,27 1 6,3,222 4,,167 6 2,3,111 4 1,,56 2,3 2 3 4 5 6 7 9 1 11 12 13 14 15 16, 17 1 Frese S DN2 High Pressure kv (m 3 /h),2,6 1, 1,5 1,9 2,3 2,7 3,1 3,5 3,6 Δp kpa UK DEC. 9

Page 1 of 15 DN25 LP - Dynamic Pressure and Regulation Valve L/s L/h,694 25 Frese PV DN25 5-3 kpa ΔPs 6,9,556 2 4,4,417 15 5 kpa 1 kpa 15 kpa 2 kpa 25 kpa 3 kpa 2,5,27 1 1,1,139 5,3 2 3 4 5 6 7 9 1 11 12 13 14 15 16 17 1, 19 2 21 22 23 24 25 26 27 2 29 3 31 32 33 34 35 36 (l/s) (l/h),472 17,444 16,417 15,39 14,361 13 Frese S DN25 Low Pressure Kvs (m 3 /h) min. Δp kpa,2,7 1,3 1,9 2,5 3, 3,4 3,7 4, 4,1 17 16,5 16 15,5 15,333,36,27,25,222,194,167,139,111,3 12 11 1 9 7 6 5 4 3 14,5 14 13,5 13 12,5 12 11,5 11 1,5 1 UK DEC. 9,56,2 2 9,5 1 9,5 1 2 3 4 5 6 7 9 1

Page 11 of 15 DN25 HP - Dynamic Pressure and Regulation Valve Frese PV DN25 2-6 kpa L/s 1,111 L/h 4 17,7,972 35 13,6,33 3 2 kpa 3 kpa 4 kpa 5 kpa 6 kpa 1,,694 25 6,9,556 2 4,4,417 15 2,5,27 1 1,1,139 5,3 2 3 4 5 6 7 9 1 11 12 13 14 15 16, 17 1 19 2 21 22 23 24 25 26 27 2 29 3 31 32 33 Frese S DN25 High Pressure kv (m 3 /h) Δp kpa,3, 1,5 2,2 2, 3,3 3, 4,1 4,3 4,4 UK DEC. 9

Page 12 of 15 DN32 HP - Dynamic Pressure and Regulation Valve L/s L/h 1,39 5 Frese PV DN32 2- kpa ΔPs 19,2 1,25 45 15,6 1,111 4 12,3,972,33 35 3 2 kpa 3 kpa 4 kpa 5 kpa 6 kpa 7 kpa kpa 9,4 6,9,694 25 4,,556 2 3,1,417 15 1,7,27 1,,139 5,2 2 3 4 5 6 7 9 1 11 12 13 14 15 16 17 1, 19 2 21 22 23 24 25 26 27 2 29 3 31 32 33 34 Frese S DN32 High Pressure (I/S) (I/H) Kvs (m 3 /h) Δp kpa,6 1, 3, 4,1 5,2 6,3 7,3,1,7, UK DEC. 9

Page 13 of 15 L/s L/h 2,222 DN4 HP - Dynamic Pressure and Regulation Valve Frese PV DN4 2- kpa ΔPs 23, 1,944 7 1,2 1,667 1,39 6 5 2 kpa 3 kpa 4 kpa 5 kpa 6 kpa 7 kpa kpa 13,4 9,3 1,111 4 5,9,33 3 3,3,556 2 1,5,27 1,4 2 3 4 5 6 7 9 1 11 12 13 14 15 16, 17 1 19 2 21 22 23 24 25 26 27 2 29 (I/S) (I/H) Frese S DN4 High Pressure Kvs (m 3 /h) Δp kpa,5 2, 4, 5,9 7,6 9, 1,5 11, 12,9 13,2 UK DEC. 9

Page 14 of 15 DN5 HP - Dynamic Pressure and Regulation Valve L/s L/h Frese PV DN5 2- kpa ΔPs 3,9 14 61,2 3,333 12 44,9 2,77 1 2 kpa 3 kpa 4 kpa 5 kpa 6 kpa 7 kpa kpa 31,2 2,222 2, 1,667 6 11,2 1,111 4 5,,556 2 1,2 2 3 4 5 6 7 9 1 11 12 13 14 15 16 17 1, 19 2 21 22 23 24 25 26 27 2 (I/S) (I/H) Frese S DN5 High Pressure Kvs (m 3 /h) Δp kpa 1,1 3,6 6,2,6 1,6 12,4 14, 15,4 16,2 16,7 UK DEC. 9

Page 15 of 15 - Dynamic Pressure and Regulation Valve Text for technical specifications The valve should be a dynamic differential pressure and flow control valve with the option of setting the differential pressure and flow on site without suspension of operation. The valve should limit the differential pressure in a circuit. The valve should include optional P/T plugs for the verification of differential pressure in circuit and across the valve. The differential pressure control valve scale should only be adjustable by means of a key. The flow control valve should only be adjustable by means of a lockable handle. The valve should be permanently marked with an indicator for flow direction. Pressure rating PN16. UK DEC. 9 Frese A/S assumes no responsibility for errors, if any, in catalogues, brochures, and other printed matter. Frese A/S reserves the right to modify its products without prior notice, including already ordered products, if this does not alter existing specifications. All registered trademarks in this material are the property of Frese A/S. All rights reserved. Frese A/S Sorøvej DK- 42 Slagelse Tel: +45 5 56 Fax: +45 5 56 91 frese@frese.dk