DULUX L LUMILUX IMPROVED LIFETIME & SYSTEM GUARANTEE. DULUX L LUMILUX & QUICKTRONIC TECHNICAL INFORMATION 1.

Similar documents
DULUX L LUMILUX DE LUXE

QTi DALI/DIM / QTi GII / QTP5

QT-FIT8 2X58-70/ VS20

QT-FIT8 2X58-70/ VS20

QTi DALI/DIM / QTi GII / QTP5

LUMILUX T5 HO CONSTANT

QTi DALI/DIM / QTi GII / QTP5

POWERBALL HCI -T. Technical Information. POWERBALL HCI -T for enclosed fixtures.

HCI-TT 250 W/942 NDL PB

POWERBALL HCI -TC. Technical Information. POWERBALL HCI -TC for enclosed luminaires.

POWERBALL HCI -T. Technical Information. POWERBALL HCI -T for enclosed luminaires.

HCI-T 70 W/942 NDL PB

HCI-T 70 W/942 NDL PB

POWERBALL HCI-T. Product family datasheet. Metal halide lamps with ceramic technology for enclosed luminaires

POWERBALL HCI-T. Product family datasheet. Metal halide lamps with ceramic technology for enclosed luminaires

PrevaLED Linear Slim 2

POWERSTAR HQI -TM 600 and 1000W POWERBALL HCI -TM 250 and 400W

Residential Road_Lighting Class S5

LED Modules. Fortimo LED Line High Flux PR. 2ft 4000lm 1R NA

HALODIUM II. Product family datasheet. Outdoor flood- and spotlights. Areas of application _ Facades and monuments _ Parks

EX-RECESSED CEILING LIGHT FITTINGS

Aluminum Capacitors +85 C, Miniature, Axial Lead

CURION 185 FIXED Colour White = MW Matte White RAL 9016 Colour Black = BL Matte Black RAL 9005 Beam Angle 80 EN60598 / EN62031 / EN62471 >25 >25.

SPORTS: Single Tennis court 24x11m for class III

SPORTS: Single Tennis court 24x11m for class III

TUV Low Pressure Mercury

DRIVER VOLTAGE DRIVER TYPE. DM v Low Voltage Dimming (10% - 100%) (Standard) LV - Line Voltage Dimming *Specify Voltage (120v or 277v)

The AR111 LED is ideal solution for spot lighting in shops

Photometric Test Report

Less power great performances

T5 Retail Sales. 2011, September 8 data subject to change

TEST REPORT. ACCORDING TO IES LM For. Samsung Electronics Co., LTD. 1,Samsung-Ro,Giheung-Gu,Yongin-City,Gyeonggi-Do 17113, Korea

LED Lightsource-R High Bay - EU

LED Lightsource-R High Bay - EU

DRIVER VOLTAGE DRIVER TYPE. DM v Low Voltage Dimming (10% - 100%) (Standard) LV - Line Voltage Dimming *Specify Voltage (120v or 277v)

Technical data: SCHUCH quality - Your advantage:

LED Tips & Tricks. PO Box 1949, Nelson 7040, New Zealand. Head Office, 53C Bolt Road, Nelson 7011, New Zealand

LED lighting systems

User manual. PCA EXCEL one4all with corridorfunction PCA T5 ECO lp with corridorfunction TE one4all with corridorfunction

Mirror with Socket

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES. For. EiKO Global, LLC W 84th Street, Shawnee, KS 66227

MULTILAYER CERAMIC CHIP CAPACITORS

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

FENCER Under Cabinet LED Light Fixture

Series AM3T-VZ 3 Watt DC-DC Converter

LED Down Light (8 ) Dimension:

Technical data: SCHUCH quality - Your advantage:

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

Medium Power Film Capacitors

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

LM LUMEN MAINTENANCE TEST REPORT

JSP. MKT Series J S P -

POWERED BY IP66 IK08 LM-80 LED URBAN LIGHT. LED Urban Light

LED Tube Lights. Product Features. Applications

Experience bright and vivid colors

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

Surface Mount Specialty Polymer Solid Aluminum Electrolytic Capacitors

ASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom

ENGLISH. Datasheet L60 Thermocouple & Fine Wire Welder

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

RobLight FL 1500 B-2. User manual. Applies to: RobLight A/S Nordhavnsvej 1A DK Frederikshavn. Phone:

TURQUOISE SWITCHES ABJ (BJ) SWITCHES

COMFORT LED. The new TECO range

Datasheet ANSI Type K & T Exposed Welded Tip Thermocouples (ANSI Colour Code)

Airfield Lighting. For your runway and taxiway safety

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

FL200 Monochromatic Architectural Spot and Floodlight

Type 160 Metallized Polyester Radial Lead Capacitors

ENGLISH Datasheet IEC PTFE Exposed Welded Tip Thermocouples with Miniature Thermocouple Plug

User Manual PTW-DensiX. D / Di/Zi

R / WOUND technology from pitch 10 to 27.5mm (Rated Voltage from 63 to 1000Vdc) PRODUCT CODE SYSTEM

A smooth design solution for a seamless look

MULTILAYER CERAMIC CHIP CAPACITORS

Light Engines. Data Sheets. Nix II Series. Oberon II Series. Pluto II Series. Titan II Series. Mercury II Series. Aries II Series.

IEC Thermocouple Extension Leads with Miniature or Standard Thermocouple Connectors - Available in types K, J, T & N

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

MWR - MWF Metallized polyester film capacitor MKT - High performance

Product Specification Spring Finger

A smooth design solution for a seamless look

Datasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code

Technical Data Sheet 339-9SUGSURSUBC/S1182. Features. Descriptions. Applications. Device Selection Guide

LED T8 U-BEND DIRECTFIT PLASTIC SERIES UL TYPE-A

Type 715P/717P, Orange Drop, High Voltage, Polypropylene Film/Foil

Stance LED Pendant Indirect/Direct

LAMP 339-9SUGSURSUBC/S1174

Type 715P/717P, Orange Drop, High Voltage, Polypropylene Film/Foil

204-10SDRD/S530-A3 LAMP. Features. Description. Applications. Revision 1. LifecyclePhase: Expired Period: Forever. Choice of various viewing angles

Datasheet ANSI Standard Duplex Thermocouple Connector Sockets Types K, J, T, E, N, R/S & B (ANSI Colour Code)

ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code)

333-2SURC/H3/S530-A4 LAMP. Features. Description. Applications. 1 Ver.:2 Release Date:12/13/2016 狀態 :Approved( 正式發行 )

AMS 2710 PCB pressure sensor module with V output

Pneumatic pressure switch 20DD

LED FLOOD LIGHTING SPORTS LIGHTING CASE STUDY. Yankee Stadium. New York USA

HBLT-A1 LIQUID LEVEL SENSOR

SIROCCO. Robust high-pressure diecast aluminium housing. Computer aided design reflector. Graduated scale for accurate aiming.

EALP05RDBRA0 LAMP. Features. Description. Applications. Choice of various viewing angles. Available on tape and reel. Reliable and robust

CGA Series Automotive Grade Capacitors

Medium Power Film Capacitors

Part 1 General Information Part 2 Outdoor Units... 8

Transcription:

www.osram.com IMPROVED LIFETIME & SYSTEM GUARANTEE QTP-M 1x26-42 TECHNICAL INFORMATION 1

Benefits Extremly economical Good quality of light Excellent luminous flux Improved lumen maintenance Long service life time OSRAM + Guarantee LUMILUX with QUICKTRONIC Environmental friendly Product Features Improved average lamp life: up to 20.000 h (with QUICKTRONIC ) Good color rendering (R a 80 89) Dimming (from 100 1% with QTI DALI/DIM) Also as blue available 18 36W: Operation with electronic and conventional control gear + starter 40 80W: Operation with electronic control gear Dimensions Description Base Max Length L1 Max Length L1 IEC Max Length L2 18 W 2G11 217 225 222 17.5 24 W 2G11 317 320 322 17.5 36 W 2G11 411 415 416 17.5 40 W 2G11 533 535 538 17.5 55 W 2G11 533 535 538 17.5 80 W 2G11 565 565 570 17.5 Tube Diameter d TECHNICAL INFORMATION 2

Electrical Data 1 Lamps opa with 50Hz reference ballast at 25 C (100 h aged) ambient temperature Lamp Voltage [V] Lamp Current [ma] Lamp Power [W] Compensation parallel Capacitor CCG 2 mode 3 [µf] 18 W 58 375 16 4.2 2.7 24 W 87 345 22 3.6 2.7 36 W 106 435 32 4.4 3.4 Compensation series Capacitor CCG mode 4 [µf] Lamps opa with HF 5 reference control gear at 25 C (100 h aged) ambient temperature Lamp Voltage [V] Lamp Current [ma] 18 W 50 320 16 24 W 75 300 22 36 W 90 360 32 40 W 126 320 40 55 W 101 550 55 80 W 145 555 80 Lamp Power [W] Photometrical Data at 25 C (100 h aged) ambient temperature 6 Light Rendering Index (CRI), Ra Luminance (LC 7 840) [cd/cm²] Target Coordinate X Target Coordinate Y Nominal Flux [lm] Efficacy 25 C 18 W 827 INTERNA 80 89 2.1 0.463 0.420 1200 67 B 18 W 830 Warm White 80 89 2.1 0.440 0.403 1200 67 B 18 W 835 White 80 89 2.1 0.409 0.394 1200 67 B 18 W 840 Cool White 80 89 2.1 0.380 0.380 1200 67 B 24 W 827 INTERNA 80 89 2.1 0.463 0.420 1800 75 B 24 W 830 Warm White 80 89 2.1 0.440 0.403 1800 75 B 24 W 835 White 80 89 2.1 0.409 0.394 1800 75 B 24 W 840 Cool White 80 89 2.1 0.380 0.380 1800 75 B 36 W 827 INTERNA 80 89 2.8 0.463 0.420 2900 81 A 36 W 830 Warm White 80 89 2.8 0.440 0.403 2900 81 A 36 W 835 White 80 89 2.8 0.409 0.394 2900 81 A 36 W 840 Cool White 80 89 2.8 0.380 0.380 2900 81 A 36 W 865 Cool Daylight 80 89 2.8 0.313 0.337 2750 76 B 36 W 880 SKYWHITE 80 89 2.8 0,294 0,309 2610 73 B Energy Efficiency Class 1 According to IEC 60901 2 Conventional Control Gear 3 For cos phi = 0.95; Dielectric strength of the capacitor 250V AC; capacitive tolerance +/- 10% 4 Dielectric strength of the capacitor 450V AC 5 High Frequency 6 Measurement in accordance with IEC 60901, annex C and the relevant annex on colour characteristics in IEC 60081. 7 Light TECHNICAL INFORMATION 3

Light Rendering Index (CRI), Ra Luminance (LC 840) [cd/cm²] Target Coordinate X Target Coordinate Y Nominal Flux [lm] Efficacy 25 C 40 W 827 INTERNA 80 89 2.3 0.463 0.420 3500 88 A 40 W 830 Warm White 80 89 2.3 0.440 0.403 3500 88 A 40 W 835 White 80 89 2.3 0.440 0.403 3500 88 A 40 W 840 Cool White 80 89 2.3 0.380 0.380 3500 88 A 40 W 865 Cool Daylight 80 89 2.3 0.313 0.337 3325 83 A 40 W 880 SKYWHITE 80 89 2.3 0,294 0,309 3150 79 B 55 W 827 INTERNA 80 89 3.2 0.463 0.420 4800 87 A 55 W 830 Warm White 80 89 3.2 0.440 0.403 4800 87 A 55 W 835 White 80 89 3.2 0.409 0.394 4800 87 A 55 W 840 Cool White 80 89 3.2 0.380 0.380 4800 87 A 55 W 865 Cool Daylight 80 89 3.2 0.313 0.337 4550 83 B 55 W 880 SKYWHITE 80 89 3.2 0,294 0,309 4320 79 B 80 W 830 Warm White 80 89 3.7 0.440 0.403 6000 75 B 80 W 840 Cool White 80 89 3.7 0.380 0.380 6000 75 B 80 W 880 SKYWHITE 80 89 3.7 0,294 0,309 5400 68 B Energy Efficiency Class Relative Flux / Ambient Temperature For more detailed information please refer to our technical guide Compact Fluorescent Lamps. Free download at www.osram.com TECHNICAL INFORMATION 4

Lifetime 8 ECG 9 preheated IEC switching cycle 10 CCG IEC switching cycle B50 11 20000 h 10000 Service life time 12 13000 h 7500 LLMF 13 2000 h 0.90 0.85 LLMF 4000 h 0.84 0.78 LLMF 6000 h 0.82 0.76 LLMF 8000 h 0.81 0.75 LLMF 12000 h 0.78 - LLMF 16000 h 0.78 - LLMF 20000 h 0.76 - LSF 14 2000 h 0.99 0.99 LSF 4000 h 0.99 0.99 LSF 6000 h 0.99 0.97 LSF 8000 h 0.99 0.85 LSF 12000 h 0.95 - LSF 16000 h 0.80 - LSF 20000 h 0.50-8 Measurement in accordance with IEC 60901, annex C. 9 Electronic Control Gear 10 Switching cycle 165 min. on, 15 min. off (according to IEC) 11 Average lamp life (B50) is the average value of the life values of individual lamps ope under standardized conditions (50% failure). In other words, this is the operation time at which, for a standardized 3-hour switching cycle (165 minutes on / 15 minutes off, see annex C, IEC 60901), 50% of a sample population of lamps have failed. 12 Service life time is the mathematical life time (maintenance multiplied with the % of failed lamps e.g. B10) for lamps in an installation after which the installation luminous flux (100 h value) decreased with 30 % (decrease in luminous flux and failed lamps) for indoor lighting. 13 Lamp Lumen Maintenance Factor (Lamp luminous flux in %): Ratio of the luminous flux of a specific quantity of lamps at a defined number of hours of operation to their luminous flux at 100 h 14 Lamp Survival Factor (Lamp Survival in %): Ratio of the number of electrically intact lamps to the total number of lamps TECHNICAL INFORMATION 5

Logistic Data Description EAN 10 EAN 40 LUMILUX 18W/827 4050300010748 4050300242163 10 LUMILUX 18W/830 4050300010731 4050300242149 10 LUMILUX 18W/835 4050300295893 4050300295909 10 LUMILUX 18W/840 4050300010724 4050300242125 10 LUMILUX 24W/827 4050300010779 4050300242200 10 LUMILUX 24W/830 4050300010762 4050300242187 10 LUMILUX 24W/835 4050300295916 4050300295923 10 LUMILUX 24W/840 4050300010755 4050300242330 10 LUMILUX 24W/67 4050300354033 4050300354040 10 LUMILUX 36W/827 4050300010809 4050300242279 10 LUMILUX 36W/830 4050300010793 4050300242248 10 LUMILUX 36W/835 4050300295930 4050300295947 10 LUMILUX 36W/840 4050300010786 4050300242224 10 LUMILUX 36W/865 4050300328263 4050300139364 10 LUMILUX 36W/880 4008321185891 4008321185907 10 LUMILUX 40W/827 4050300322285 4050300315867 10 LUMILUX 40W/830 4050300298894 4050300298900 10 LUMILUX 40W/835 4050300295954 4050300295961 10 LUMILUX 40W/840 4050300279909 4050300279916 10 LUMILUX 40W/865 4050300592008 4050300592015 10 LUMILUX 40W/880 4008321185914 4008321185921 10 LUMILUX 55W/827 4050300315881 4050300315898 10 LUMILUX 55W/830 4050300298917 4050300298924 10 LUMILUX 55W/835 4050300295978 4050300295985 10 LUMILUX 55W/840 4050300295879 4050300295886 10 LUMILUX 55W/865 4050300553900 4050300553917 10 LUMILUX 55W/880 4008321185938 4008321185945 10 LUMILUX 80W/830 4050300665467 4050300665474 10 LUMILUX 80W/840 4050300665481 4050300665498 10 LUMILUX 80W/880 4008321185952 4008321185969 10 Packaging Unit TECHNICAL INFORMATION 6

Lamp/ECG Combination Lamp ECG EAN 10 ECG 18 W 24 W flux @25 C power I N Power Factor ECG [λ] luminous efficacy Length Width Height Distance between holes [lm] [W] [A] [ C] QTi DALI 1x18/220-240 DIM 4050300870403 1200 18 0.08 0.97 67 360.00 30.00 21.00 350 +10 +50 C QTi DALI 2x18/220-240 DIM 4050300870526 2400 37 0.16 0.97 65 425.00 30.00 21.00 415 +10 +50 C QTi DALI 3x18/220-240 DIM 4008321069979 3600 53.6 0.24 0.98 67 360.00 40.00 21.00 350 +10 +50 C QTi DALI 4x18/220-240 DIM 4008321070050 4800 69.3 0.31 0.98 69 360.00 40.00 21.00 350 +10 +50 C QTi 1x18/220-240 DIM 4050300870601 1200 19 0.08 0.97 63 360.00 30.00 21.00 350 +10 +50 C QTi 2x18/220-240 DIM 4050300870960 2400 37 0.16 0.97 65 425.00 30.00 21.00 415 +10 +50 C QTi 3x18/220-240 DIM 4008321069931 3600 53.6 0.24 0.98 67 360.00 40.00 21.00 350 +10 +50 C QTi 4x18/220-240 DIM 4008321070012 4800 69.3 0.31 0.98 69 360.00 40.00 21.00 350 +10 +50 C QTP-DL 1x18-24 4008321117861 1200 18 0.085 0.95 67 239.00 30.00 28.00 229-20 +50 C QTP-DL 2x18-24 4008321117885 2400 36 0.16 0.98 67 239.00 40.00 28.00 229-20 +50 C QTP-M 1x26-42 4008321329134 1150 18 0.09 0.88 c 64 103.00 67.00 31.00 110-20 +50 C QTP-M 2x26-32 4008321329158 2300 36 0.16 0.95 64 123.00 79.00 33.00 129.5-20 +50 C QT-ECO 1x18-24/220-240 L 4050300660417 1200 18 0.13 0.92 67 150.00 22.00 22.00 140.00-15 +50 C QT-ECO 1x18-24/220-240 S 4050300638560 1200 18 0.13 0.92 67 80.00 40.00 22.00 72 75-15 +50 C QTi DALI 1x14/24/220-240 DIM 4050300870380 1600 25 0.11 0.98 64 360.00 30.00 21.00 350 +10 +50 C QTi DALI 2x14/24/220-240 DIM 4050300870861 3600 49 0.22 0.98 73 423.00 30.00 21.00 415 +10 +50 C QTi DALI 3x14/24/220-240 DIM 4008321069955 5400 73 0.32 0.99 74 360.00 40.00 21.00 350 +10 +50 C QTi DALI 4x14/24/220-240 DIM 4008321070036 7200 98 0.43 0.99 73 360.00 40.00 21.00 350 +10 +50 C QTi DALI-T/E 1x18-57 DIM 4008321060808 1200 26 0.12 0.96 46 123.00 79.00 33.00 129.5 +10 +50 C QTi DALI-T/E 2x18-42 DIM 4008321060822 2400 51 0.22 0.97 47 123.00 79.00 33.00 129.5 +10 +50 C QTi 1x14/24/220-240 DIM 4050300870922 1800 25 0.11 0.98 72 360.00 30.00 21.00 350 +10 +50 C QTi 2x14/24/220-240 DIM 4050300870946 3600 49 0.22 0.98 73 423.00 30.00 21.00 415 +10 +50 C QTi 3x14/24/220-240 DIM 4008321069719 5400 73 0.32 0.99 74 360.00 40.00 21.00 350 +10 +50 C QTi 4x14/24/220-240 DIM 4008321069993 7200 98 0.43 0.99 73 360.00 40.00 21.00 350 +10 +50 C QTP-DL 1x18-24 4008321117861 1800 26 0.115 0.95 69 239.00 30.00 28.00 229-20 +50 C QTP-DL 2x18-24 4008321117885 3600 49 0.22 0.98 73 239.00 40.00 28.00 229-20 +50 C QTP-M 1x26-42 4008321329134 1750 25 0.12 0.94 c 70 103.00 67.00 31.00 110-20 +50 C QTP-M 2x26-32 4008321329158 3500 48 0.22 0.97 73 123.00 79.00 33.00 129.5-20 +50 C QT-M 2x26-42/220-240 S 4008321110022 3500 54 0.23 0.97 65 123.00 79.00 33.00 129.5-20 +50 C QT-ECO 1x18-24/220-240 L 4050300660417 1600 22.5 0.16 0.60 71 150.00 22.00 22.00 140-15 +50 C QT-ECO 1x18-24/220-240 S 4050300638560 1600 22.5 0.16 0.60 71 80.00 40.00 22.00 72 75-15 +50 C Ta TECHNICAL INFORMATION 7

Lamp ECG EAN 10 ECG DULUX L 36 W DULUX L 40 W DULUX L 55 W flux @25 C power I N Power Factor ECG [λ] luminous efficacy Length Width Height Distance between holes [lm] [W] [A] [ C] QTi DALI 1x36/220-240 DIM 4050300870427 2900 36 0.16 0.97 81 360.00 30.00 21.00 350 +10 +50 C QTi DALI 2x36/220-240 DIM 4050300870885 5800 69 0.31 0.98 84 423.00 30.00 21.00 415 +10 +50 C QTi 1x14/24/21/39 GII 4008321383334 2750 34 0.15 0.96 81 360.00 30.00 21.00 350-20 +50 C QTi 1x36/220-240 DIM 4050300870625 2900 36 0.16 0.97 81 360.00 30.00 21.00 350 +10 +50 C QTi 2x14/24/21/39 GII 4008321383396 5600 68 0.29 0.98 82 360.00 30.00 21.00 350-20 +50 C QTi 2x36/220-240 DIM 4050300870755 5800 69 0.31 0.98 84 425.00 30.00 21.00 415 +10 +50 C QTP-DL 1x36-40 4008321117908 2900 35 0.17 0.99 83 239.00 30.00 28.00 229-20 +50 C QTP-DL 2x36-40 4008321117922 5800 68 0.33 0.99 85 280.00 40.00 28.00 270-20 +50 C QTP-M 1x26-42 4008321329134 2800 35 0.16 0.97 80 103.00 67.00 31.00 110-20 +50 C QTP-M 2x26-32 4008321329158 5600 68 0.30 0.97 53 123.00 79.00 33.00 129.5-20 +50 C QT-M 2x26-42/220-240 S 4008321110022 5600 70 0.30 0.97 80 123.00 79.00 33.00 129.5-20 +50 C QT-M 2x26-42/220-240 S 4008321110022 5600 70 0.30 0.97 80 123.00 79.00 33.00 129.5-20 +50 C QTi DALI 1x21/39/220-240 DIM 4050300870366 3500 41.8 0.18 0.98 84 360.00 30.00 21.00 350 +10 +50 C QTi DALI 2x21/39/220-240 DIM 4050300870489 7000 82 0.36 0.97 85 425.00 30.00 21.00 415 +10 +50 C QTi DALI-T/E 1x18-57 DIM 4008321060808 3500 45 0.2 0.98 78 123.00 79.00 33.00 129.5 +10 +50 C QTi DALI-T/E 2x18-42 DIM 4008321060822 7000 87 0.38 0.99 80 123.00 79.00 33.00 129.5 +10 +50 C QTi 1x14/24/21/39 GII 4008321383334 3500 44 0.19 0.98 80 360.00 30.00 21.00 350-20 +50 C QTi 1x21/39/220-240 DIM 4050300870564 3500 41.8 0.18 0.98 84 360.00 30.00 21.00 350 +10 +50 C QTi 2x14/24/21/39 GII 4008321383396 7000 86 0.37 0.98 81 360.00 30.00 21.00 350-20 +50 C QTi 2x21/39/220-240 DIM 4050300870694 7000 82 0.36 0.97 85 423.00 30.00 21.00 415 +10 +50 C QTP-DL 1x36-40 4008321117908 3600 45 0.21 0.99 80 239.00 30.00 28.00 229-20 +50 C QTP-DL 2x36-40 4008321117922 7300 90 0.21 0.99 81 280.00 40.00 28.00 270-20 +50 C QTP-M 1x26-42 4008321329134 3500 43 0.19 0.98 81 103.00 67.00 31.00 110-20 +50 C QTi DALI 1x28/54/220-240 DIM 4050300870809 4800 59 0.26 0.99 81 360.00 30.00 21.00 350 +10 +50 C QTi DALI 2x28/54/220-240 DIM 4050300870502 9600 115 0.51 0.99 83 423.00 30.00 21.00 415 +10 +50 C QTi 1x28/54/220-240 DIM 4050300870588 4800 59 0.26 0.99 81 360.00 30.00 21.00 350 +10 +50 C QTi 1x35/49/80 GII 4008321383372 4800 59 0.26 0.99 81 360.00 30.00 21.00 350-20 +50 C QTi 2x28/54/220-240 DIM 4050300870717 9600 115 0.51 0.99 83 423.00 30.00 21.00 415 +10 +50 C QTP5 1x54 4008321329394 4450 54 0.24 0.98 82 280.00 30.00 21.00 270-20 +50 C QTP5 2x54 4008321329097 8900 110 0.48 0.99 81 360.00 30.00 21.00 350-20 +50 C QTP-DL 1x55 GII 4008321390158 4800 59 0.26 0.99 81 280.00 30.00 21.00 270-20 +50 C QTP-DL 2x55 GII 4008321390172 9600 116 0.51 0.99 83 360.00 30.00 21.00 350-20 +50 C QTP-FC 1x55 4008321537041 4700 60 0.26 0.99 78 103.00 67.00 31.00 350-20 +50 C QT-FQ 2x80 4050300825564 9600 122 0.59 0.99 79 423.00 30.00 21.00 415-20 +50 C Ta TECHNICAL INFORMATION 8

Lamp ECG EAN 10 ECG DULUX L 80 W flux @25 C [lm] power [W] I N [A] Power Factor ECG luminous efficacy Length Width Height Distance between holes QTi DALI 1x35/49/80/220-240 DIM 4050300870342 6000 88 0.4 0.99 68 360.00 30.00 21.00 350 +10 +50 C QTi DALI 2x35/49/80/220-240 DIM 4050300870441 12000 165 0.74 0.99 73 423.00 30.00 21.00 415 +10 +50 C QTi 1x35/49/80 GII 4008321383372 6000 85 0.38 0.98 71 360.00 30.00 21.00 350-20 +50 C QTi 1x35/49/80/220-240 DIM 4050300870540 6000 88 0.4 0.99 68 360.00 30.00 21.00 350 +10 +50 C QTi 2x35/49/80/220-240 DIM 4050300870540 12000 165 0.74 0.99 73 360.00 30.00 21.00 350 +10 +50 C QTP5 1x80 4008321329059 6000 86 0.38 0.98 70 360.00 30.00 21.00 350-20 +50 C QT-FQ 2x80 4050300825564 12300 175 0.76 0.99 70 423.00 30.00 21.00 415-20 +50 C Ta [ C] For more information on ECG refer to http://www.osram.com/ecg For more information on Guarantee refer to http://www.osram.com/guarantee In case of lamp breakage: www.osram.com/brokenlamp For more information technical Information see Technical guide. Free download at www.osram.com TECHNICAL INFORMATION 9