Professor of Clinical Anesthesiology, state University of New York, Health Science Center at Brooklyn, 450 Clarkson Avenue, Box 6, Brooklyn, NY

Similar documents
Temperature Influence on the Flammability Limits of Heat Treating Atmospheres

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Ignition Sensitivity of Nonmetallic Materials in Oxygen-Enriched Air NITROX : A Never Ending Story in SCUBA Diving?

End of Chapter Exercises

End of Chapter Exercises

You should be able to: Describe Equipment Barometer Manometer. 5.1 Pressure Read and outline 5.1 Define Barometer

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

CHEM 3351 Physical Chemistry I, Fall 2017

Opposed-Flow Flame Spread in a Narrow Channel Apparatus over Thin PMMA Sheets

THREE DIMENSIONAL FLAME PROPAGATION ABOVE LIQUID FUEL POOLS

I.CHEM.E. SYMPOSIUM SERIES NO. 97 THE FLASH-BACK HAZARD IN STACKS DISCHARGING FLAMMABLE GASES

CHAPTER 3 RESULTS AND DISCUSSION

CFD SIMULATIONS OF GAS DISPERSION IN VENTILATED ROOMS

SOLAR 93 THE 1993 AMERICAN SOLAR ENERGY SOCIETY ANNUAL CONFERENCE. Washington, DC April 22028,1993. Editors: S. M. Burley M. E.

MEDICAL GASES Manufacture, Storage, Transport & Delivery B.KIRUTHIGA LECTURER DEPT OF PHARMACEUTICAL CHEMISTRY

EXPERIMENTAL STUDY OF HOT INERT GAS JET IGNITION OF HYDROGEN-OXYGEN MIXTURE

Focus on VOC Emissions Reduction Using an Oxygen Based Inerting Control System For Inert Gas Blanketing of Chemical Process Vessels

Available online at ScienceDirect

Name Hour. The Behavior of Gases. Practice B

FLAME SPREAD BEHAVIOR OVER COMBINED FABRIC OF COTTON/POLYESTER

SUMMARY OF THE EXPERIMENTAL STUDIES OF COLD HELIUM PROPAGATION ALONG A SCALE MODEL OF THE LHC TUNNEL

Determination of flammability limits of diluted H 2 /CO/CH 4 /air mixtures in spherical bomb

substitution Rearrangement solving for n/v Convert n to MASS (m) by multiplying BOTH sides by molar mass (M) d = m/v

DEMONSTRATION 2.1 PROPERTIES OF CO 2. Chapter 2: Gases

Interchangeability Criteria.

THE GAS STATE. Unit 4. CHAPTER KEY TERMS HOME WORK 9.1 Kinetic Molecular Theory States of Matter Solid, Liquid, gas.

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

Generating Calibration Gas Standards

Helium Mass Spectrometric Leak Detection In Large Size Process Plants

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Flow and Mixing in the Liquid between Bubbles

Heat-Trapping Gases Lab

MEMORANDUM. Investigation of Variability of Bourdon Gauge Sets in the Chemical Engineering Transport Laboratory

EXPERIMENTAL RESULTS OF GUIDED WAVE TRAVEL TIME TOMOGRAPHY

Problem Solving. Gas Laws

Kinetic-Molecular Theory

Chapter 13 Temperature, Kinetic Theory, and the Gas Laws 497

Gas Pressure. Pressure is the force exerted per unit area by gas molecules as they strike the surfaces around them.

Comparative Study of Oxygen Permeation Through Polymers and Gas Barrier Films

Atmospheric Waves James Cayer, Wesley Rondinelli, Kayla Schuster. Abstract

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

Procedure 1: Volume vs. Pressure 1.) Using the lap tops, go to the Physics Education Technology from the University of Colorado at:

Dalton s Law How is the total pressure of a mixture of gases related to the partial pressures of the component gases?

Experimental study on the gas tightness of a mined cavern with groundwater

Investigation of Suction Process of Scroll Compressors

Boyle s Law Practice

An experimental study of internal wave generation through evanescent regions

Study on Intensity of Blast Wave Generated from Vessel Bursting by Gas Explosion

SPONTANEOUS IGNITION OF PRESSURIZED HYDROGEN RELEASE

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India)

4.) There are no forces of attraction or repulsion between gas particles. This means that

WP2 Fire test for toxicity of fire effluents


UNIT 10 - GASES. Notes & Worksheets - Honors

School of Chemistry SOP For Operation Of Glove Boxes

CHEMISTRY - CLUTCH CH.5 - GASES.

Problems of Chapter 3

Experiment 13: Make-Up Lab for 1408/1420

Model Description

Gases. Edward Wen, PhD

A PILOT STUDY ON HYPOXIC AIR PERFORMANCE AT THE INTERFACE OF FIRE PREVENTION AND FIRE SUPPRESSION

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS

4. Using the kinetic molecular theory, explain why a gas can be easily compressed, while a liquid and a solid cannot?

Guide to Gases and Vapours

I. Subject: Compressed gas cylinders, regulators, and portable liquid systems.

Gas volume and pressure are indirectly proportional.

Sign up to receive ATOTW weekly -

PURE SUBSTANCE. Nitrogen and gaseous air are pure substances.

ISO INTERNATIONAL STANDARD

THE DECOMPOSITION OF POTASSIUM CHLORATE This lab is derived almost entirely from a lab used at the United States Naval Academy

Extinguishment of a Laminar Jet Diffusion Flame Using a Soap Bubble Filled with Nitrogen Gas

GASES. Unit #8. AP Chemistry

Dust explosion severity characteristics of Indonesian Sebuku coal in oxy-fuel atmospheres

Our Air- Why We Should Care!

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

A Reliable and Tracer Gas Independent Leak Detector for Food Packages

Preliminary design of a high-altitude kite. A flexible membrane kite section at various wind speeds

HYDROGEN FAST FILLING TO A TYPE IV TANK DEVELOPED FOR MOTORCYCLES

Cooling Gases Phase Changes and Phase Diagrams

CHEM 355 EXPERIMENT 7. Viscosity of gases: Estimation of molecular diameter

Barrier Development and Evaluation Methodology. D.S. Musgrave 1 1 Thermal Visions, Inc., Granville, USA

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Inquiry Investigation: Factors Affecting Photosynthesis

The Effect of Von Karman Vortex Street on Building Ventilation

Chapter 13 Fluids. Copyright 2009 Pearson Education, Inc.

Influence of rounding corners on unsteady flow and heat transfer around a square cylinder

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

INFLUENCE OF INITIAL PRESSURE ON THE IGNITION AND COMBUSTION OF A PROPELLING CHARGE. Patrice Franco

THE WAY THE VENTURI AND ORIFICES WORK

Chemistry Chapter 11 Test Review

Experiment 1 Basic Laboratory Operations

Page 1

Ch. 14 The Behavior of Gases

PREPARATION AND PROPERTIES OF ATMOSPHERIC GASES I: Carbon Dioxide and Oxygen

Development of High-speed Gas Dissolution Device

Accelerated Chemistry Study Guide Chapter 13: Gases

Properties of Gases Observing Atom Pressure of a Gas Measuring Gas Products of Chemical Inferring Molecule Reactions

Worksheet 1.7: Gas Laws. Charles Law. Guy-Lassac's Law. Standard Conditions. Abbreviations. Conversions. Gas Law s Equation Symbols

Transcription:

George W. Sidebotham 1, James A. Cross 2, Gerald L. Wolf 3 A TEST METHOD FOR MEASURING THE MINIMUM OXYGEN CONCENTRATION TO SUPPORT AN INTRALUMINAL FLAME REFERENCE: Sidebotham, G.W., Cross, J.A., and Wolf, G.L., "A Test Method for Measuring the Minimum Oxygen Concentration to Support an Intraluminal Flame," Flammabilitv and Sensitivity of Materials in Oxygen-Enriched Atmospheres. ASTM STP 1197. Dwight D. Janoff, and Joel M. Stoltzfus, Eds., American Society for Testing and Materials, Philadelphia, 1993. ABSTRACT: A test method for measuring the minimum concentration.to support an intraluminal flame is described. An oxidizer is flowed through a plastic tube, and an ignition source is applied to the free end of the tube. If the oxygen concentration is sufficient, a flame propagates along the inner surface of the tube, termed an intraluminal flame. The minimum concentration of oxygen, or limiting oxygen index (LOI), that will support such a flame is determined. Results are reported for polyvinyl chloride tubing and compared to those using the standard ASTM D 2863, the candle-type flammability test. In the intraluminal test, the LOI with helium as the diluent gas is lower than that with nitrogen as the diluent, in contrast to results using ASTM D 2863. The effects of buoyancy are reduced in the intraluminal test, and the results may therefore be more applicable to low gravity environments. KEYWORDS: Flame spread, oxygen index, polyvinyl chloride, combustion, endotracheal tube fires, microgravity Assistant Professor of Chemical Engineering, The Cooper Union for the Advancement of Science and Art, 51 Astor Place, New York, NY 10003. 2 Cooper Union Masters degree recipient. the Brooklyn Union Gas Company, Brooklyn, NY. 3 Currently with Professor of Clinical Anesthesiology, state University of New York, Health Science Center at Brooklyn, 450 Clarkson Avenue, Box 6, Brooklyn, NY 11203.

INTRODUCTION The minimum oxygen concentration that will support combustion is a useful measure of the relative flammability of solid materials in oxygen enriched atmospheres. The well known candle-type flammability test [1] was originally published in 1970 as the ASTM Standard Test Method for Measuring the Minimum Oxygen Concentration to Support Candle-like Combustion of Plastics (Oxygen Index) D 2863. The minimum oxygen concentration is also referred to as the limiting oxygen index (LOI) [2] or the critical oxygen index (COI) [3]. An alternative experimental methodology to obtain an LOI is presented in this paper. It is emphasized that a universal LOI does not exist for a given material [3, 4]. Rather, an LOI exists for a material for a given test method. Therefore, application of standardized test results to a particular system must be made with caution. It is left to the discretion of the designer or user of a system to determine whether or not the results from the standard test accurately reflect what can be expected in the system under consideration. Even if quantitative agreement between the standard test and an application is uncertain, it is tempting to speculate that qualitative trends are preserved: if material A is less flammable than material B in the LOI test, then A is less flammable than B in any system. The results reported here suggest that even qualitivative agreement can be suspect. The present work is an outgrowth of research into operating room fire safety problems [5]. The accidental ignition of endotracheal tubes during surgery by surgical lasers, electrosurgical units and electrocautery continues to pose a fire risk in the oxygen-enriched environment of the mouth or airway. In an effort to understand this endotracheal tube fire problem, a simple experiment was developed. Results of this experiment and a discussion of the flame mechanisms are reported in reference [6]. Briefly, an oxidizer is flowed through a plastic tube and an ignition source is applied to the open end of the tube. A flame, termed an intraluminal flame, is observed to propagate along the inside surface of the tube at a measurable speed. It was concluded that this intraluminal flame spread process characterizes endotracheal tube fires. For a given oxygen concentration, there exist flow limits: if the flow rate of oxidizer is too great or too small, an intraluminal flame cannot be established. As the oxygen concentration is reduced, the rate of flame spread decreases and the flow limits narrow until a limiting oxygen concentration is reached below which an intraluminal flame cannot be established. The results of such tests then represent an alternative measure of the limiting oxygen index. Results from this test are reported and compared to

those obtained by the standard ASTM D 2863 method. EXPERIMENTAL A brief description of the experimental approach used to determine the limits of intraluminal flame spread in polyvinyl chloride tubing is reported here. Further details can be found in reference [7]. Gaseous flows were obtained from compressed gas cylinders. Flow rates were regulated by mass flow controllers, calibrated with a soap bubble meter. In the present study, various sizes of Clear-flo polyvinyl chloride tubing, obtained from New Age Industries, were used. Data has not yet been obtained for other materials. The ignition source was a pilot flame obtained by flowing natural gas through a small copper tube to yield a diffusion flame approximately 1 cm in height. To perform the test, a section of tubing, sufficiently long to guarantee fully developed flow, was connected to the oxidizer source. The downstream end was horizontal, open to the atmosphere, and loosely supported by a clamp, allowing the tube to hang cantilevered approximately 15 cm from the clamp. The tube was marked on the outside with a greaseless pen at known intervals, typically 5 cm. A fixed flow rate of oxidizer (oxygen plus diluent) was delivered to the test specimen. The ignition source was applied to the free end after sufficient time was allowed to flush the system. The flame event was successful if an intraluminal flame propagated for at least 5 cm, or survived at least 3 minutes. This criterion is the same as that in ASTM D 2863. If an event occurred, the oxygen concentration was decreased by either lowering the oxygen flow rate (with fixed diluent flow), or by increasing the diluent flow (with fixed oxygen flow). The test was repeated until a flame did not satisfy the criterion for a successful event. There was concern that the oxygen concentration in the vicinity of the free end was lowered due to mixing with ambient air. To investigate this effect, tests were performed in which the ignition source was inserted approximately 3 cm into the tube instead of being applied to the free end. The results were not affected by how the ignition source was applied. A complication of the test was encountered in determining the upper flow limit in some cases. At high oxygen concentrations, it was observed that a flame could be anchored outside of the free end, and slowly consume the entire tube, yielding an apparent flame spread rate. This "free end flame" was considered to be stabilized outside of

the flame by a complex recirculation pattern that existed outside the tube. However, the leading edge of this flame never entered into the tube, and is not considered an intraluminal flame. This complication did not occur near the limiting oxygen concentration. The conventional candle-type ASTM (D 2863) was performed on the same material to allow comparison with the present intraluminal flame test. Following Simpson, et al. [4], the test was adapted to a tube material and other diluents. The flame spread in this test was observed to occur on the outside surface of the tube. RESULTS Figure 1 shows the intraluminal flame spread rate as a function of oxidizer velocity for 50% O2 mixtures (by volume) in nitrogen and helium. The techniques used to generate these data are described in reference [6]. In both cases, there is a lower flow limit, and upper flow limit, and a peak in the flame spread rate. It is apparent that helium yields a much higher peak flame spread rate than nitrogen. However, beyond the flame spread rate peak, the 0.45-0.4-0.35-0.3-8 0.25H o> o 0.2^ CO O) 0.15- <D I 0.1-0.05-0 0 50 100 150 200 250 Oxidizer Flow Velocity (cc/sec) 300 350 Figure 1 Intraluminal flame spread rate versus oxidizer flow velocity for 50 vol% oxygen in two diluent gases. 3.2 mm inner diameter, 6.4 mm outer diameter polyvinyl chloride tubing was used.

rate of decay of flame spread rate with increasing oxidizer flow is also much larger for helium. Therefore, the upper flow limit occurs at a lower total oxidizer flow for helium. For other oxygen concentrations, the shapes of the curves are similar, but the limits are wider for higher oxygen concentrations, and shallower for lower oxygen concentrations. Flammability maps, which indicate flammable and non-flammable regions, can be constructed using data of this type. Figure 2 shows a conceptual diagram of a flammability map, in which flammable regions are separated from nonflammable regions. The oxygen concentration is plotted against the total oxidizer flow rate (or flow velocity) in the tube. For a given oxygen concentration, low flow and high flow limits exist. These limits approach each other as the oxygen concentration is reduced until they meet. The oxygen concentration below which intraluminal flames cannot be established is the limiting oxygen index for intraluminal flame propagation. The flammable region is separated into two parts. Region A represents intraluminal flame propagation, while region B represents the so-called "free end flames" that were stabilized outside the free end of the tube. For all cases investigated here, the onset of these flames occurred at higher oxygen concentrations than the LOI, and therefore did not interfere with the attainment of the LOI. The non-flammable region is separated into three parts. Regions C and D represents regions with sufficient oxygen concentration, but are below the lower flow limit, or above the upper flow limit respectively. Region E represents regions in which the oxygen concentration is sufficiently low that intraluminal flames cannot be established for any flow rate. Figure 3 shows a typical flammability map in which the oxygen concentration is plotted against the oxidizer velocity (total flow rate divided by the area). Conditions that yielded intraluminal flames are reported with one symbol, and conditions which did not yield flames are reported as another symbol. The limiting oxygen index is the lowest oxygen concentration for which a flame existed, and occurs at a particular flow velocity. For every tube material, tube geometry and diluent type, a flammability map similar to Figure 3 must be developed to yield the LOI. Experience dictated that the lower flow limit was easily and reproducibly obtained. To isolate the lower flow limit, it was most convenient to fix the diluent flow rate, and to vary the oxygen flow rate. In this manner, successive tests yielded points along a line roughly perpendicular to the lower flow limit line. In principle,

100% x 0 I0) O) Intraluminal Flames free-end flames B D Limiting Oxygen Index 0% Figure 2 Oxidizer Flow Rate Schematic representation of a flammability map. 1 UU C? 0~^ X cu T3 = C 0) o> X O 90-80- 70-60- 50-40- 30- c' Flammable G " m! D m "n H? G L -C- T ^ "p"^ a ^^ INTRALUMINAL S* FREE-END Q NO FLAME 20-10- Non-Flammable n- 10 100 1000 10000 Oxidizer Flow Velocity (cm/sec) Figure 3 Typical flammability map. 3.2 mm inner diameter, 6.4 outer diameter tubing. Nitrogen is the diluent gas. Data points indicate the type of flame observed for conditions tested.

the upper flow limit could similarly be most conveniently obtained by fixing the oxidizer flow and varying the diluent flow. However, since the magnitude of the slope of the lower flow limit was much steeper than that of the upper flow limit, it was found that this approach was not necessary to find the LOI. Figure 4 shows the effect of the inner diameter on the LOI for four different diluents. It is apparent that the LOI decreases with increasing tube inner diameter for the intraluminal flame test. The LOI obtained with helium is consistently lower than that obtained with nitrogen. This result suggests that nitrogen is a more effective flame suppressant than helium. Carbon dioxide (CO2) yielded the highest LOI, and argon yielded the lowest LOI. The conventional candle-type flammability test (ASTM D 2863) was performed on the same material using nitrogen and helium as diluents. The LOI was found to be weakly dependent on size for the candle type test. The average LOI was 24.2 for nitrogen mixtures, and 30.2 for helium mixtures. This trend of greater values of LOI when helium is used as compared to nitrogen is consistent with that reported by Werley [4] and Simpson et al. [5], and suggests that helium is a more effective diluent at suppressing flame spread, in contrast to the conclusion using the intraluminal test. The results with carbon dioxide and argon using the candle-type test [4] are consistent with those found in the present study. 50 x CD CD O) >- X O O> c CO2 45-40- 35-30- 25-20 0 1 2 3 4 5 6 7 3 Tube Inner Diameter (mm) 10 Figure 4 Limiting oxygen index as a function of tube inner diameter. Four different inerts were tested. Results from ASTM D 2863 are indicated for nitrogen and helium.

DISCUSSION In order to understand the trends observed in the intraluminal LOI test, it is helpful to reconsider the mechanisms of flame spread, discussed by Classman [2], as applied to intraluminal flame spread [6]. A schematic of the intraluminal flame spreading process is shown in Figure 5. The bulk of the flame is a gas phase diffusion flame in which the gaseous fuel is obtained by gasification of the solid fuel. The energy for gasification comes from heat conducted through the gaseous fuel vapor to the solid fuel. There is a quenching layer between the flame and the solid fuel because the solid fuel vaporizes at a much lower temperature than that at the diffusion flame surface. Inside the quenching layer and near the leading edge of the flame, fuel and oxidizer mix. Therefore, the leading edge is a pre-mixed flame which propagates toward the opposed flow at a distance from the solid fuel, termed the quenching distance. At low flows, the flame spread rate increases with increasing oxidizer flow because of the increase in fuel gasification rate associated with the improved heat transfer rate from the hot flame gases to the solid fuel. However, as the oxidizer flow rate is increased, the spreading flame must propagate against a stronger opposed flow. Eventually, Solid Fuel =H Oxidizer Solid Fuel = Quenching Layer Hot Products + Vaporized Fuel Spreading Diffusion Flame Pre-mixed Leading Edge Figure 5 Schematic of an intraluminal flame. The flame is spreading from right to left as indicated by the solid arrow. The fuel is thinner downstream of the flame because of fuel vaporization.

this latter effect dominates the former, and the flame spread rate in the laboratory reference frame is observed to peak, then decrease with increasing oxidizer flow. Ultimately, the opposed flow rate at the quenching distance is greater than the leading edge pre-mixed flame speed, and the flame cannot enter into the tube. This effect then yields the upper flow limit, or "blow-out" limit. Helium vs. Nitrogen Helium has a much higher thermal diffusivity, hence higher quenching distance, than nitrogen*. Therefore, since the velocity profile is parabolic, the velocity at the quenching distance is larger for helium than for nitrogen for the same oxidizer flow velocity. An intraluminal flame with helium as the inert is more sensitive to an increase in flow velocity. Helium has a lower specific heat than nitrogen, hence higher flame temperatures, than nitrogen. Therefore, since the leading edge pre-mixed speed increases strongly with temperature, the flame spread rate for helium is greater than that for nitrogen for low opposed flow rates (where the effects of the opposing flow are not dominant). Buoyancy Effects The effects of natural convection, or buoyancy, on flame spread help explain the difference between the standard candle-type test and the intraluminal flame test. For opposed flow flame spread with an oxidizer of infinite extent, the flame can induce a flow into the flame [2]. The hot gases produced by the flame have a low density, and therefore experience a buoyant upward acceleration. To conserve mass, these rising gases are replaced by fresh gas. As a result, the spreading flame experiences an induced opposed flow even in a quiescent atmosphere. When the forced flow is much less than that generated by natural convection, the flame spread rate is independent of the forced flow. This result is experimentally verified for flame spread over flat plates [2], Further, for these experiments, a low flow limit of flame spread has never been reported. In contrast, for intraluminal flames, the flame does not propagate into an oxidizer of infinite extent. Hot The depth of the quenching layer is related to heat conduction. The magnitude of the quenching distance is proportional to the thermal diffusivity of the gas (the thermal conductivity divided by the density and the specific heat), which varies approximately with the inverse square root of the molecular weight.

gases generated in the flame have no place to rise in the confines of the tube. Therefore, there is no induced flow due to buoyant effects, and the only flow rate the flame experiences is the forced flow supplied through the tube. Indeed, as the oxidizer flow rate decreases, the flame spread rate decreases until the lower flow limit is reached. The only previous reports of low flow limits of flame spread are those in microgravity experiments [8]. The candle-type flammability test yields results for LOI which are insensitive to forced flow within the oxidizer flow range dictated (provided there is no mixing of ambient air [3]). It is thus argued that the flow field in the vicinity of the burning sample is controlled by buoyant effects. A plausible explanation for higher LOIs in helium compared to nitrogen is that with the larger quenching distance, and induced buoyant flow rate, the leading edge of the helium flame experiences a higher opposed velocity. Application to Other Material Geometries While the intraluminal flammability test is well suited to tube geometries of transparent materials, it may be possible to extend the test to solid materials which are not in tubular form. For example, holes of a given size can be drilled into a plate of plexiglass to simulate a tube geometry, and an oxidizer flowed through the holes. Alternatively, the flame spread between two sheets of plexiglass through which an oxidizer flows can be attempted. If the test is to be extended to opaque materials, a method of flame detection must be identified. CONCLUSIONS 1) The minimum oxygen concentration which will support an intraluminal can be measured easily and reproducibly. 2) In comparing the effects of nitrogen versus helium, opposite trends are observed with the intraluminal test as compared to the standard ASTM test. The intraluminal test is considered to be more relevant to the endotracheal tube fire problem. 3) The results of the test depend on the inner diameter of the tube. This dependence must be further understood prior to proposing a standard test method. 4) In principle, adaptations of the intraluminal test can be applied to any solid material which can be tested using the standard candle-type test. 5) The effects of buoyancy are much less important in the intraluminal flammability test than they are in the candle-type test. Therefore, the intraluminal flame test may be useful for low gravity applications.

ACKNOWLEDGEMENTS The authors would like to thank Robert Aftel for assistance with many experiments, Ron Adner for obtaining the data with carbon dioxide and argon, and to four high school students, Jeannette Cooper, Steven Kovach, Xiao Yang Li and Wei Lian Su, who obtained nitrogen data as part of a summer research internship program at the Cooper Union. REFERENCES [1] Fenimore, C.P. and Martin, F.J., "Candle-Type Test for Flammability of Polymers," Modern Plastics. MOPLA, Vol. 43, November 1966, p. 141. [2] Classman, I., "Combustion Fundamentals of Low Volatility Materials in Oxygen-Enriched Atmospheres," Flammability and Sensitivity of Materials in Oxygen- Enriched Atmospheres. ASTM STP 1111. Joel M. Stoltzfus and Kenneth Mcllroy, Eds., American Society for Testing and Materials, Philadelphia, 1991. [3] Wharton, R.K., "An Assessment of the Critical Oxygen Index Test as a Measure of Material Flammability," Flammability and Sensitivity of Materials in Oxygen- Enriched Atmospheres. ASTM STP 986. D.W. Schroll, Ed., American Society for Testing and Materials, Philadelphia, 1987. [4] Werley, B.L. "An Oxygen Index Update," Flammability and Sensitivity of Materials in Oxygen-Enriched Atmospheres. ASTM STP 986, D.W. Schroll, Ed., American Society for Testing and Materials, Philadelphia, 1988. [5] Simpson, J.I., Wolf, G.L., and Schiff, G.A., "The Oxidant 02 (Helium) Index of Flammability of Endotracheal Tubes," Flammability and Sensitivity of Materials in Oxygen-Enriched Atmospheres. ASTM STP 1040. Joel M. Stoltzfus, Frank J. Benz, and Jack S. Stradling, Eds., American Society for Testing and Materials, Philadelphia, 1989. [6] Sidebotham, G.W., Wolf, G.L., Stern, J. and Aftel, R. "Endotracheal Tube Fires: A Flame Spread Phenomenon," Flammability and Sensitivity of Materials in Oxygen- Enriched Atmospheres, ASTM STP 1111. Joel M. Stoltzfus and Kenneth Mcllroy, Eds., American Society for Testing and Materials, Philadelphia, 1991. [7] Cross, J.A., "Effects of Intraluminal Helium and Nitrogen on Flammability Characteristics of Polyvinyl Chloride Tubes with Application to the Tracheal Tube Fire Problem," Masters of Engineering thesis, The Cooper Union, New York, NY, May 1991. [8] Olson, S.L., "Mechanisms of Microgravity Flame Spread Over a Thin Solid Fuel: Oxygen and Opposed Flow Effects," Combustion Science and Technology. Vol. 76, pp. 233-249, 1991.